Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Works (100 Capacity Hostel)2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil |
| 2 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 3 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | CEMENT CONCRETE (CAST IN SITU)(P.C.C)4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 7 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 8 | REINFORCED CEMENT CONCRETE5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.5.33.1 All works upto plinth level5.33.1.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | 5.3 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.5.33.2 All works above plinth level upto floor V level5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 10 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 12 | 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 13 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | 5.9.7 Stairs, (excluding landings) except spiral-staircases |
| 15 | 5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 16 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 19 | 6 MASONRY WORK6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 20 | HALF BRICK MASONRY6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) |
| 21 | 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water / moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).26.86.6 Frame size 65 x 125 mm |
| 22 | 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)26.87.2 35 mm thick |
| 23 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 24 | 9.15 Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. |
| 25 | 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 26 | VITRIFIED FLOOR TILES11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1 Size of Tile 600 x 600 mm |
| 27 | 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigmentsetc. complete.11.46.2 Size of Tile 600x600 mm |
| 28 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.1 Light shade pigment using white cement |
| 30 | 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble8.2.1.1 Area of slab upto 0.50 sqm |
| 31 | CEMENT PLASTER (IN COARSE SAND)13.1 12 mm cement plaster of mix :13.1.1 1:4 (1 cement: 4 fine sand)13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 32 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 33 | 13.10 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.13.2.1 1:4 (1 cement: 4 fine sand) |
| 34 | 13.28 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand):13.28.4 Moulded Band |
| 35 | 13.46 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 37 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 38 | 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.12.41.1 75 mm diameter |
| 39 | 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.12.43.1 75 mm |
| 40 | 9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete:9.92.1 125 mm |
| 41 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.4 150x10 mm |
| 42 | 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 43 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 44 | 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :21.1.1 For fixed portion21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 45 | 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 46 | 21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge.21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 47 | 25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 48 | 25.2 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 49 | 25.2 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) |
| 50 | 22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :22.4.1 Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) |
| 51 | 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :22.4.1 Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) |
| 52 | 22.14 Grading roof for water proofing treatment with22.14.2 Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 53 | 22.5 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:22.4.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 54 | 9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.9.20.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 55 | 9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 9.22.1 On one side only |
| 56 | 9.22 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.9.79.2 50 mm |
| 57 | 9.90 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.9.90.2 Size 50 mm |
| 58 | 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.8.9.1 8mm thick8.9.1.2 Granite of any colour and shade |
| 59 | SANITARY & PLUMBING WORKS (2 nos. 50 capacity hostel)17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:17.1.1 White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 60 | 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 61 | 17.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushingcistern |
| 62 | 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.5 White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap |
| 63 | 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :17.10.2 Kitchen sink without drain board17.10.2.1 610x510 mm bowl depth 200 mm |
| 64 | 17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 65 | 17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 66 | 17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :17.32.3 Oval shape 450x350 mm (outer dimensions) |
| 67 | 17.35 Providing and fixing soil, waste and vent pipes17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 68 | 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 69 | 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :18.22.2 150 mm diameter |
| 70 | 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.18.8.1 15 mm nominal dia Pipes |
| 71 | 18.8.2 20 mm nominal dia Pipes |
| 72 | 18.8.3 25 mm nominal dia Pipes |
| 73 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work18.9.1 15 mm nominal dia Pipes |
| 74 | 18.9.3 25 mm nominal dia Pipes |
| 75 | 18.9.6 50 mm nominal dia Pipes |
| 76 | 18.9.8 80 mm nominal dia Pipes |
| 77 | 18.9.9 100 mm nominal dia Pipes |
| 78 | 18.15 Providing and fixing brass bib cock of approved quality 18.15.1 15 mm nominal bore: |
| 79 | 18.16 Providing and fixing brass stop cock of approved quality :18.16.1 15 mm nominal bore |
| 80 | 18.20 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :'18.20.1 15 mm nominal bore |
| 81 | 18.20.2 20 mm nominal bore |
| 82 | 18.90A Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90°18.90A.1 For 15 mm outer dia pipe |
| 83 | 18.90A.2 For 22 mm outer dia pipe |
| 84 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 85 | 100 USERS SEPTIC TANK2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil |
| 86 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 87 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 88 | 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 89 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :4.3.1 Foundations, footings, bases for columns |
| 90 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.21:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 91 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 92 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 93 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 94 | 6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :6.12.1 Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 95 | 13.8 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :13.8.1 1:3 (1 cement: 3 fine sand) |
| 96 | 5.12 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 97 | 19.18 Supplying and fixing C.I. cover without frame for manholes :19.18.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 98 | 19.30 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 99 | 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 100 | 17.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 101 | 17.36 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes17.36.2 100 mm dia pipe |
| 102 | DEEP TUBE WELL23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.23.1.2 Rocky strata including Boulders23.1.2.1 300 mm dia |
| 103 | 23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.23.3.2 150 mm nominal size dia |
| 104 | 23.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 105 | 23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 106 | 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).23.15.2 150 mm dia |
| 107 | 18.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality. |
| 108 | 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work ) 18.46.5 40 mm nominal bore |
| 109 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.18.9.3 25 mm nominal dia Pipes |
| 110 | 18.9.5 40 mm nominal dia Pipes |
| 111 | 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) :18.19.3 40 mm nominal bore18.19.3.2 Vertical |
| 112 | Construction of Drain 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 113 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 114 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 115 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 116 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 117 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 118 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 119 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 120 | ICBP Approach16.78 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 121 | 16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.16.78.2 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 122 | 16.3 Supplying and stacking at site.16.3.3 53 mm to 22.4 mm size stone aggregate |
| 123 | 16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 124 | 16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 125 | 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.4.4.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 126 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 127 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 128 | Landscaping(DSR H& L 2020) 3.78 Providing and displaying of Raphis palm specimen having ht. 1.50 m to 1.65 m with 40 to 50 lush green suckers, well developed, fresh & healthy foliage leaves in 40 cm size of Earthen Pot/Chali/Tray & as per direction of the officer-in-charge. |
| 129 | (DSR H& L 2020) 3.83 Providing and displaying of Seaforthia Palm having ht. 1.50 m to 1.80 m with 12-15 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 130 | (DSR H& L 2020) 5.11 Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 131 | (DSR H& L 2020) 5.30 Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge. |
| 132 | (DSR H& L 2020)2.57 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)2.57.1 Trees Plant |
| 133 | (DSR H& L 2020) 2.4 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :2.4.1 Screened through sieve of I.S. designation 20 mm |
| 134 | (DSR H& L 2020) 2.8 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 135 | (DSR 2021)11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:11.1.1 1:4 (1 cement : 4 coarse sand) |
| 136 | (External Electrification)2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.2.2.2 125 A, 16 KA, TP MCCB |
| 137 | 2.2.17 250 A, 50KA,FPMCCB |
| 138 | /2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.15.3 63 A |
| 139 | 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 140 | 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 141 | 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with G.I. thimble etc.as required |
| 142 | 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 143 | 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.7.1.4 Above 185 sq. mm and upto 400 sq. mm |
| 144 | 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.1.13. 3 X 95 sq. mm (38mm) |
| 145 | 9.2 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.2.21 3½ X 95 sq. mm |
| 146 | 13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required |
| 147 | 13.4 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required |
| 148 | 13.10 Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required |
| 149 | 13.11 Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required |
| 150 | 13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required |
| 151 | MR-1 Supply, Installation andCommissioning of 30 W Solar Two-In-One(Semi Integrated) LED street light System with Poly Crystalline PV Panel, output 125lm/W, Battery 30Ah, Type of Battery :12.8V LiFePo4, Panel-125Wp and 7m Octagonal Pole. as required and as directed by the Department (Surya/Orient/Bajaj/Havells or equivalent). |
| 152 | APDCL SOR-752 Supplying including erection of 12.00 Mtr. G.I. Steel Tubular Pole (410-SP-60) (Stnd.Weight 208 K.g.) along with fitting fixing, excavation work, foundation of bolts and nuts in R.C.C. work in 1:3:6 proportion of 1.80 Mtr. Depth, Cement plastering and etc. complete with all necessary materials as required and specified by the Department.12 Mtr. G.I. Steel Tubular Pole (410-SP-60) |
| 153 | MR-3 Supplying including installation, commissioning of 500 Amp, Indoor Type, Floor Mounted, Distribution Control Panel Board, 1.6 mm CRCA Sheetmade, painted with SIEMENS GREY Powder Coat Paints after Pretreatment through 9 Tank (Cold Processing), 250 Amps Aluminium Busbar, Angle Stand Frame (40 mm x 40 mm x 6 mm), internal wiring and Labour charge etc. Size = 1500 mm (L) x 1200 mm (H) x 300 mm (D). |
| 154 | MR-4 Supplying,installation,testing and commissioning of the 63 KVA 11/0,433KV Aluminium wound outdoor type oil filled (4 Star/ Level-II) Transformer complete including all accessories like Earthing terminal, Lifting Lugs, Drain Valve, Oil filling Hole with plug, Silicigel Breather, First filling of Oil as per IS 355, Arcing Horn, Radiator, Air Release Plug, Conservator Tank etc. along with charging approval of the Sub-Station from the competent authority as directed and specified by the department. Transformer should be as per CEA guideline as ammended up to date.(All require materials for the Sub-Station will be measured & paid separately) (POWER MAKER UNIT -II).63 KVA 11/0,433KV |
| 155 | MR-5 Supplying Power / Control Copper Cables, Solid Copper conthuctor up to 6 sq. mm balance Stranded,XLPE Insulated, cores laid up,PVC tape inner sheathed for Multicore Cables, Unarmored / Armour ( Glavanised wire for cables up to 10 x1.5 sq.mm, 8 x 2.5 sq,mm, 2 x 10 sq.mm, 3 x 10 sq.mm, 4 x 6 sq.mm balance all galvanized steel strip), extruded PVC Type ST2 Sheathed,650/1100 V grade as per IS 7098 (Part 1) 1988 (Havells, RR, or equivalent make as approved by the Deptt.) 2.5 sq.mm 10 Core Copper cable. |
| 156 | MR-6 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV Gd. Solid Aluminum conductor up to 10 sq.mm, balance stranded conductor, XLPE Insulated, core laid up, PVC tape inner sheathed, Armor (Aluminum wire for single core up to 70 sq.mm, balance Aluminum strip, Galvanized wire for cable up to 2 x 10 sq.mm, 4 x 6 sq.mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100V grad as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR or equivalent make as approved by this Deptt.)A-6.00 sq.mm 2 Core U.G. Cable |
| 157 | B-10.00 sq.mm 2 Core U.G. Cable |
| 158 | C-150.00 sq.mm 3.5 Core U.G. Cable |
| 159 | MR-7 APDCL SOR-519 Supplying with fitting and fixing of 11 KV GOAB Switch 400 Amp. as required and specified by the Department. |
| 160 | MR8 APDCL SOR-514 Supplying with fitting and fixing of 11 KV D.O. Fuse set 200A Assembly as required and specified by the Department. |
| 161 | MR-9 APDCL SOR-562 Supplying with fitting and fixing of 3-Phase-4W Combined CT/PT Accuracy Class 0.5 400/5A, STC:18.1KA for 1 Sec. as required and specified by the Department. |
| 162 | MR-10 APDCL SOR-488 Supplying with fitting and fixing 3-Phase 4W ICS DLMS compliant LT Trivector energy meter (Category-A), 3 x 240V phase to neutral-5A Class 0.5s for DTR metering. |
| 163 | MR11 APDCL SOR-459 Supplying with fitting and fixing 11 KV 1C x 70sq.mm AAAC Covered Conductor. |
| 164 | MR-12 APDCL SOR-474 plying with errection of CI Earth pipe 1.8m inner dia 100mm, outer dia 110mm with perforated holes of 15mm dia at 30 cm interval along length of the pipe as required and specified by the Department. |
| 165 | MR-13 APDCL SOR- 420 DTR Fencing as per REC standard specification complete with material & labour. (As per APDCL -2021-22) |
| 166 | C.E. Approved rate Payment to be made to APDCL authority for Load security. |
| 167 | INTERNAL ELECTRICAL1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 Group A |
| 168 | 1.10.2 Group B |
| 169 | 1.10.3 Group C |
| 170 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 171 | 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 172 | 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 173 | 1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 174 | 1.24 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etcas required.1.24.1 5/6 amps switch |
| 175 | 1.24.3 15/16 A switch |
| 176 | 1.24.4 3 pin 5/6 A socket outlet |
| 177 | 1.24.5 6 pin 15/16 A socket outlet |
| 178 | 1.24.8 Bell Push |
| 179 | 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 180 | 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.2 3 Module (100mmX75mm) |
| 181 | 1.27.5 8 Module (125mmX125mm) |
| 182 | 1.27.6 12 Module (200mmX150mm) |
| 183 | 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required1.28.2 3 Module |
| 184 | 1.28.5 8 Module |
| 185 | 1.28.6 12 Module |
| 186 | 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 187 | 1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 188 | 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 189 | 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.2.2.15 200 A, 36 KA,FPMCCB |
| 190 | 2.5 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.4.2 6 way (4 + 18), Double door |
| 191 | 2.4.3 8way (4 + 24), Double door |
| 192 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1 Single pole |
| 193 | 2.10.3 Double pole |
| 194 | 2.10.5 Triple pole and neutral |
| 195 | 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.13.2 63 A |
| 196 | 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.15.3 63 A |
| 197 | 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 198 | 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 199 | 5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 200 | 6.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 201 | 6.4 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 202 | 6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 203 | 6.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 204 | 7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.7.3.1 upto 35 sq. mm |
| 205 | 7.3.3 Above 95 sq. mm and upto 185 sq. mm |
| 206 | 19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 207 | MR-1 Supplying with including fitting fixing of 20 Watt LED Tube Light etc. as directed by the Deptt . |
| 208 | MR-2 Supplying with including fitting fixing of LED Bulb 9Watt etc. as directed by Deptt. |
| 209 | MR-3 Supplying with fitting & fixing of All-in-one Solar Street Light 40W as directed by the Department. |
| 210 | MR-4 Supplying with including fitting fixing of Exhaust Fan etc. as directed by Deptt |
| 211 | MR-5 Supplying, fittings and fixings of 2 H.P. Submerssible pump set (Water filled motor) as required and directed by the department. ( Crompton/ Kirloskar/ Usha or equivalent) 2 H.P. Submersible pump set |
| 212 | MR-6 Supplying with fitting & fixing of A.C/ Motor Starter Switch 240V-50Hz complete with necessary electrical connection etc. as required and as directed by the Department. (Orient / Havell/ Bajaj Make). |
| 213 | MR-7 Supplying and fitting fixing of electric storage water heater (Geyser) of ( Bajaj or equivalent make) including necessary connection etc. as required complete and as directed by the Department. |
| 214 | MR-8 Supplying, installation, testing and commissioning of the Three Phase Energy Meter |
| 215 | MR-9 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV Gd. Solid Aluminum conductor up to 10 sq.mm, balance stranded conductor, XLPE Insulated, core laid up, PVC tape inner sheathed, Armor (Aluminum wire for single core up to 70 sq.mm, balance Aluminum strip, Galvanized wire for cable up to 2 x 10 sq.mm, 4 x 6 sq.mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100V grad as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR or equivalent make as approved by this Deptt.)120.00 sq.mm 3 ½ Core U.G. Cable |
| 216 | MR-10 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV Gd. Solid Aluminum conductor up to 10 sq.mm, balance stranded conductor, XLPE Insulated, core laid up, PVC tape inner sheathed, Armor (Aluminum wire for single core up to 70 sq.mm, balance Aluminum strip, Galvanized wire for cable up to 2 x 10 sq.mm, 4 x 6 sq.mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100V grad as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR or equivalent make as approved by this Deptt.)35.00 sq.mm 3 ½ Core U.G. Cable |
| 217 | 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required1.53.1 1 run of cable |
| 218 | MR-11 Supplying with fitting & fixing of RJ 45 Jack with Cat 6 etc. as required and as directed by the Department. |
| 219 | MR-12 Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 36kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in an enclosure and necessary connection.160Amp 4P MCCB |
| 220 | MR-13 160Amp 4P Manual Changeover Switch |
| 221 | MR-14 Supplying and fixing double door Vertical TPN Distribution board for MCCB incomer with IP-43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Up to 160A)12WAY VTPN DB |
| 222 | MR-15 Supplying and fixing of 7.5KVA Online UPS WITH 60 Minutes Battery Back UP all complete |
| 223 | MR-16 Supplying with fitting & fixing of Indoor WIFI System complete etc. as required and as directed by the Department. |
| 224 | PORTABLE EXTINGUISHERSSupply & fixing of 6 Kg ABC type dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle and hanging arrangement complete conforming to IS:15683 |
| 225 | Providing & fixing 4.5kg CO2 type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:940 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail