| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil all lead and lifts as directed by the Engineer-in- charge. All kinds of soil |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete including carriage of material in all leads and lifts. |
| 3 | Stone soling properly handpacked filling interstices with spalls and consolidating with hand ramming to the required level including spreading watering and ramming complete as per HP.PWD specification. 100 mm spread thickness (finished work including materials and labour) including carriage of material in all leads and lifts. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 Cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size) including carriage of material in all leads and lifts. |
| 5 | Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/water retaining structures by using 125gms of synthetic Polyester triangular fibre for 50 Kg cement used as per directions of Engineer-in-Charge. including carriage of material in all leads and lifts. |
| 6 | Reinforced cement concrete work in columns, beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for : including carriage of material in all leads and lifts. |
| 8 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 9 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 10 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more including carriage of material in all leads and lifts. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material in all leads and lifts |
| 13 | Half brick masonry with comman burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level in cement mortar 1:4 (1 cement: 4 sand) including carriage of material in all leads and lifts |
| 14 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material in all leads and lifts. |
| 15 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in any colours, shades of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete including carriage of material in all leads & lifts. |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws including carriage of material in all leads and lifts. |
| 17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. including carriage of material in all leads and lifts. (a) Fixed to steel windows by welding. |
| 18 | Providing and fixing aluminium powder coated sliding door bolt, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of material in all leads and lifts(a) 300x16mm |
| 19 | Providing and fixing aluminium powder coated tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.complete including carriage of material in all leads and lifts. (a) 200x10mm |
| 20 | Providing and fixing aluminium powder coated handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of material in all leads and lifts. (a) 125mm |
| 21 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. including carriage of material in all leads and lifts. (a) Single rubber stopper. |
| 22 | board as per direction of Engineer-in-charge. Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 23 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. including carriage of material in all leads and lifts. (a) Using M.S. angels 40x40x6 mm for diagonal braces |
| 24 | Providing & fixing 4.0 mm thick glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete including carriage of material in all leads and lifts. |
| 25 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including putty and fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge including carriage of material in all leads and lifts. |
| 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete including carriage of material in all leads and lifts.(a) 40 mm thick with 20 mm nominal size stone aggregate. |
| 27 | Providing and laying vitrified floor tiles as per sample approved by the Engineer-in- charge (thickness not less than 10mm) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete including carriage of material in all leads and lifts. |
| 28 | Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles any size/colour manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete including carriage of material in all leads & lifts. |
| 29 | Providing and laying Vitrified tiles as per sample approved by the Engineer-in- charge (thickness not less than 8 mm)with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. including carriage of material in all leads and lifts. |
| 30 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion, sliding sash super sash profile 160, glazing 5 mm thick toughened glass stain less steel mesh grade-304, white handles including fasteners, weather proof silicon sealant stainless steel screws etc. complete in all respect as directed by Engineer-in-Charge including carriage of material in all leads and lifts. |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of material in all leads and lifts. |
| 32 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) including carriage of material in all leads and lifts. |
| 33 | CEMENT PLASTER (IN FINE SAND) 20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) including carriage of material in all leads and lifts |
| 34 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) including carriage of material in all leads and lifts |
| 35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work (two or more coats) over and including water thinnable priming coat with cement primer including carriage of material in all leads and lifts. |
| 36 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including carriage of material in all leads and lifts. |
| 37 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel and wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture including carriage of material in all leads and lifts. |
| 38 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required including carriage of material in all leads and lifts. (a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 39 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require including carriage of material in all leads and lifts.(ESS-ESS/CZAR/NOVA) (a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 40 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. internal work - exposed on wall including carriage of material in all leads and lifts. (a) 15 mm dia nominal bore. |
| 41 | Providing and fixing 15 mm nominal bore C.P. brass bib cock long body of approved quality conforming to IS:8931 including carriage of material in all leads and lifts. |
| 42 | Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 including carriage of material in all leads and lifts. |
| 43 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete including carriage of material in all leads and lifts. |
| 44 | 110 mm dia. |
| 45 | 75 mm dia. |
| 46 | Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. complete including carriage of material in all leads and lifts. |
| 47 | 110 mm dia |
| 48 | 75 mm dia |
| 49 | Providing and fixing P.V.C connection pipe with bras unions. (a) 30cm length / 45 cm length (I) 15mm Nominal size bore (confirming to BIS Specifications) including carriage of material in all leads & lifts. (ESS-ESS/CZAR/NOVA) |
| 50 | Providing and fixing G.I./M.I. Union of 15mm size (where not included in the item) (confirming to BIS Specifications) including carriage of material in all leads & lifts. (ESS-ESS/CZAR/NOVA) |
| 51 | Providing and fixing PVC water storage tank of ISI : 12701 marked, G.I. inlet and outlet connection, 15mm nominal bore ball valve and mosquito proof PVC cover with locking arrangement including hoisting up to all heights above ground level including carriage of material in all leads and lifts:-1000 litres net capacity tank. |
| 52 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling and dash fasteners to be paid for separately). |
| 53 | For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 54 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) |
| 55 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 56 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 57 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre,including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. (Only weight of grill to be measured for payment). Please Enable Macros to View BoQ information |