| 1 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 2 | [13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 3 | [13.32]Providing and fixing bolts including nuts and washers complete. |
| 4 | 24.1.3]EARTHING AND LIGHTENING ARRESTOR . Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. |
| 5 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR . Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. |
| 6 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR . Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. |
| 7 | [24.3.7.3]HT CABLE . Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : 240 to 400 sqmm |
| 8 | [7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | [27.3]Plastering (12 mm thick) with cement mortar (1:3 ) on brick work in sub-structure as per MoRTandH Specifications 1300 & 2200 |
| 10 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 11 | NS) Supply and erection of PCC pole as per IS: 1678-1960 specification, 9mtr long PCC pole 105mmx115mm at top and 105mm x315mm at bottom with working load of 200 kg buried 1.5 in ground as per DHBVNL specification. |
| 12 | NS) Supply and erection of PCC pole as per IS: 1678-1960 specification, 11 mtr long 152mm x203mm at top and 152mm x368mm at bottom with working load of 360kg buried 1.8 in ground as per DHBVNL specification. |
| 13 | NS) Supply and erection of 11 KV 400 amp. GO switch vertical mounted type and suitable for 11 KV system confirming to ISS 1818/1972 or accordance with IS:9921 complete in all respect including GI pipe, handle,M-5 steel frame and other accessories upto the entire satisfaction of engineer in-charge of the work. |
| 14 | NS) Supply and erection of LT fuse unit suitable for 200 KVA transformer including cost of MS clamps Nut and Bolts etc. complete in all respect upto entire satisfaction of engineer-in charge of work. |
| 15 | NS) Supply and erection of 11 KV brown glazed 10 KN pin insulator with GI pin / silicon type as per specification and approved make by DHBVNL complete in all respect |
| 16 | NS) Supply and erection of GI chain link (Mesh Jali) fencing consisting of MS angle duly embedded in ground with cement concrete 1:3:6 complete in all respect as per the entire satisfaction of engineer in charge of the work. |
| 17 | NS) Horizontal Trenchless boring for laying of HDPE pipe 160 mm dia. (PE-63) NP-4 to avoid cutting of road and other metaled portion. |
| 18 | NS) Supply and Erection of HDPE loose 160mm dia (PE-63) NP-4 for laying of underground cable of 95 to 400 Sqmm X 3 core XLPE armoured cable complete in all respect. |
| 19 | NS) S/I/T/C of ATS make – 400 KVA, 33-11/0.415 copper wound, ONAN, off load -5% to plus 5 4.5% insteps of 2.5%, 7 position with operating handle, transformer as per IS 2026 with complete accessories, like, oil level indicator, explosion vent, conservator, Radiator, drain valve, filter vale, breather, jacking pad, LV cable box, extra neutral for grounding, full of oil as per IS 355 as per DHBVN specification/approved manufactured by DHBVN (72 Months Defect liability period of T/F s, free of cost). |
| 20 | NS) Supplying and making cable route marker with cement concrete 1:2:4 (1 cement 2 coats sand: 4 graded stone aggregate 20mm nominal size) of size 60cm x 60cm at the bottom and 50cm x 50 cm at the top with a thickness of 10cm including inscription duly energized as required complete in all respect upto the entire satisfaction of engineer in charges as per IS specification. |
| 21 | NS) Providing and fixing of chemical earthing with 3.0 mtr. Long 75mm dia with GI pipe complete in all respect upto entire satisfaction of Engineer-in-charge of work. |
| 22 | NS) S/E of TR-XLPE 33KV HT alum. Size 300sqmm x 3 core, as per DHBVN approved GTP/drawings and approved vendors ISI mark laid in existing pipe/trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of engineer in charge of the work. Make:- Havell’s/CCI/Polycab/KEI. |
| 23 | NS) S/E of LT cables of 630 sqmm x 1 core armoured cable complete in all respect upto the entire satisfaction of engineer in charges as per IS specification. (Make:- Havells/Polycab/Paramount) Please Enable Macros to View BoQ information |