| 1 | MAKING FALSE CEILING AND RENOVATION OF THE COMPUTER LABORATORY WITH VITRIFIED TILE PUTTY,PAINTING IN THE DEPARTMENT OF EDUCATION, K.U. |
| 2 | (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) |
| 3 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge.(A) In 10-12 Micron thickness Annodizing filmI) Natural whitea) 3 track sliding windowi) Bottom frame |
| 4 | (ii) Top & side frame. |
| 5 | (d) Shutter for alltrack sliding window. (i) Bottom & top member. |
| 6 | (ii) Style & side member. |
| 7 | Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in builtlocking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene /EPDM gasket, locking arrangement and rollersi ) 3 track sliding window. |
| 8 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.i) For sliding windowsa) ' T' shaped EPDM gasket for frames |
| 9 | b) 'U' shaped EPDM gasket for frames. |
| 10 | Cutting of existing window . |
| 11 | Welder |
| 12 | Welder helper |
| 13 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal timber or plastered surface :With other than hi-gloss of approved quality-(iv) Two coats (with any shade except white |
| 14 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.ii) 4mm thick coloured / tinted / smoke glass |
| 15 | Proiriding and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. Sheet and galvanized with zinc coating of 150 grhs/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre ,one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intemediate G.I. channéls 45xI5x0.9 mm running at the spacing of 1200 mm centre to centre, to which ttie ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intemediate channel with connecting clips made out of 2.64 min dia x 230 mm long G.L wire at every junction, including fixing perimeter channels 0.5 mm thick 27 ned high having flanges of 20 mm and 30 mizi long, the perimeter of ceiling fixed to wall f partitién with the help of rawl plugs at 450 can.centre, with 25 mm long dry wall screws @230 mm interval, including fixing of gypsum board to exiling Section and perimeter channel with the help of dry wall.screws of.size 3Jx25 can atd30 nun c/c, including jnming and fidishing to a fiush finish of tapered and square edges of the board with recommended upto 150 mm on both sides ofjoint and two coats of primer suitable for board, all as per manufacture's specification and also includingW cost ofmaking openings&r-light fittings, grills , diffusers , cutouts made with frame of perimeter channels suitably fixed, allcomplete as per dmwings, specificañon and direction of the Engineer-in-Charge but excluding the cost of painting with: (ISI Mark on Board) |
| 16 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above |
| 17 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar ncluding rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).i) With 1:6 cement mortar(b) 20 mm thick plaster(I) In gr. Floor level |
| 18 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer. |
| 19 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats)i) Standard Quality. |
| 20 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer'sspecification and direction of Engineer-in-Charge.Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge.(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling withpigment.(B) Light Colour |
| 21 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint |
| 22 | Dismantling carefully wooden walling, flooring of ceiling and stacking dismantled materials as directed. |
| 23 | Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and inany floor including removing rubbish within alead of 75m as directed. |
| 24 | 18% GST |
| 25 | 1% CESS Please Enable Macros to View BoQ information |