| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessedmedium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group A |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required |
| 5 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | 2X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) onsurface or in recess with suitable size of phenolic laminated sheet cover in FRLSontincluding providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano typeswitch, connection, painting etc. as required. (For light plugs to be used in nonresidential buildings) |
| 8 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) onsurface or in recess with suitable size of phenolic laminated sheet cover in FRLSontincluding providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 ampspiano type switch, connection, painting etc. as required. |
| 9 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. |
| 10 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 11 | Installation,Testing comissioning of wall bracket /ceiling fitting of all sizes and shapes containing upto two GLS/CFL/LED lamp per fitting complete with all accessories including coneection etc as required |
| 12 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 13 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compactfluorescent fitting of all types, complete with all accessories and tube etc. directlyon ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required |
| 14 | Installation, testing and commissioning of ceiling fan, including wiring the downrods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable etc. as required |
| 15 | Installation of exhaust fan in the existing opening, including making good thedamage, connection, testing, commissioning etc. as required |
| 16 | Upto 450 mm sweep |
| 17 | Extra for fixing the louvers/shutter complete with frame for a exhaust fan of all sizes |
| 18 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required |
| 19 | Providing and laying earth connection from earth electrode with 4.00 mm dia copperwire in 15 mm dia G.I. pipe from earth electrode including connection with copperthimble excavation and re-filling as required |
| 20 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingalong with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 21 | Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator |
| 22 | 2+12way Double door |
| 23 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required |
| 24 | Single pole |
| 25 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required |
| 26 | Supplying of LED Adore 10 W 5 star rating B22 CDL lamp similar to Make: Havells C or its equalent to ISI standard. |
| 27 | Supply of exhaust fan 200mm sweep of make: Standard Refresh Air DX Ventilation or its equivalent to ISI standard. |
| 28 | Supplying of 10 Watt bulk head fitting of make Hevells RUGBY GENX 10 WATT BULKHEAD LIGHT 6500K or its equivalent to ISI standard etc as required. |
| 29 | Supplying of batten for LED tubes eqvt. To Havells Pride Plus Inverter Batten 20 W 6500 K V1 complete set or its equivalent to ISI standard |
| 30 | Supplying of Energy efficiency BLDC ceiling fan of white in colour without remote control of 1200mm sweep, suitable for operation on 230 volts, single phase, 50Hz, AC supply including 30cm long down rod etc. as required equivalent to Havells Efficiencia Neo (BLDC 26 W) without remote or its equivalent to ISI specifications |
| 31 | Providing and eraction of single phase metering box made out of SMC of size 250 x 250 x 155 with hinged cover and locking arrangements, viewing glass etc. as required similar to Sintex Model No. GSMB 2525. Please Enable Macros to View BoQ information |