Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down of existing Water Proofing treatment of any type (APP Membrane, Cement or earthen tile, Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirtsetc over original RCC roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water prooling treatment complete.Note : Rate includes for removing debris outside defence land |
| 2 | M & L for demolition & removal of cement concrete / padding concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directedNote : Rate includes for removing debris outside defence land |
| 3 | M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 4 | M & L for providing screed bed/rendering 10mm thick in CM (1:3) mixed with and including supply of approved water proofing compound as per manufacturers instructions by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litre/Sq m and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m complete all as specified and directed. |
| 5 | Disconnecting existing tanks, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc Capacity in litres Exc 250 & n exc 500 |
| 6 | M & L for 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 25 mm dia ball valve and (2 No.25 & 1 No.20) mm dia nipple including dismantling existing water storage tank, complete all as specified. |
| 7 | S & F in repairs 25mm bore dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) all as specified and as directed. |
| 8 | S & F PVC sintex tank cover suitable for 500/1000 litre capacity water tank complete as in repairs |
| 9 | S & F in repairs 25mm dia Nipple suitable for HDPE water tank. (Minimum weight 25mm- 65gms) |
| 10 | S & F in repairs 20mm Nipple suitable for HDPE water tank. (Minimum weight 20mm- 45gms) |
| 11 | Supply & laying 20 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified. |
| 12 | Supply & laying 25 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified. |
| 13 | S&F in repairs 20mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed |
| 14 | S&F in repairs 25mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed |
| 15 | M&L providing cement concrete type E2 1:5:10 (40mm graded stone aggregate) in foundations, filling and mass concrete for sunken floor including Demolition of cement concrete exc 15 cm thickness but above ground floors including removal of debris from MD Land complete all as specified and as directed. |
| 16 | Material and labour for water proofing to sunken portions of WCs, bathroom and kitchen etc by applying water based, cold applied, single component, elastomericin-situ seamless monolithic coating ready to use acrylic modified bituminous liquid membrance with the procedure in sequence all as specified and as directed.SURFACE PREPARATION(i) Removing all loose gravel, dirt, oil, grease and foreign matter by jet of dry air and cleaning the surface mechanically or by grinding to make it smooth before application.(ii) Repairing all cracks by cutting “V” groove and fill with PMC mortar prepared in the ratio of Shalicrete : cement : sand (1:2:5) or equivalent. (iii) Providing 50 mm x 50 mm coving made out of PMC mortar as above.MATERIAL PREPARATION(i) Stir TarFelt® LM or equivalent by a slow speed mixture (approx. 400 rpm) fitted with a suitable mixing paddle to ensure a homogenous mix.(ii) After stirring, wait for the product to settle in order to let entrapped air escape. Condt/--17 |
| 17 | Condt/--16WATERPROOFING APPLICATION(i) Slightly damp the surface. Avoid standing water / ponding.(ii) Prime the surface with a mixture of TarFelt® LM or equivalent and potable water in the ratio of 50:50 and apply @400 grm / m2 of the mixture and allow it to touch dry.(iii) Apply first coat of TarFwlt® LM @ 0.70 kg / m2 by brush / roller / airless spray while the primed surface is tracky, For faster and smoother application, airless spray is preferred.(iv) Spread fiber glass net of 45 gsm with overlap of 50 mm in both directions when the surface is till tackty.(v) Allow 1st coat to dry for 10-12 hrs.(vi) Apply second coat of TarFelt® LM @ 0.70 kg m2 by brush / roller / airless spray for final DFT of 1000 micron in two coats inclusive of fibre glass of 45 gsm (theoretical coverage depending on surface conditions).(vii) Sprinkle sand @ 200 grm / m2 over the final vertical coating when the surface is still tackty to facilitate plastering.(viii) Ensure final curing time of 36 hrs before allowing / carrying out any further work.(ix) Conduct ponding test after 7 days of curing at ambient temperature. |
| 18 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm and Re-fixing in same opening including cutting and adjusting for floor height complete all as specified and directed |
| 19 | Taking down chowkhat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and directed |
| 20 | All as per Item No 19 above, but exc 1.50 sqm and not exc 4.00 sqm each |
| 21 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each all as specified and as directed |
| 22 | Supply and fixed PVC door frame of size 50mm X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube. Fixing in opening as per specification . |
| 23 | M & L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS . |
| 24 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, clean sawn, frame rebeated on the solid , rounded or chamfered, put tegether with glue pinned at joints etc complete all as specified and as directed |
| 25 | S&F for mild steel work as in hold fast made in flat iron all as specified. |
| 26 | S&F 2nd class hard wood 35 mm thick made glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately. |
| 27 | S & F Plain framed, panelled shutter (two panel) of 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm venereed particle board with commercial veneering on both faces. rail and style are of 2nd class hardwood & The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treateds fixed to chowkhat all as specified and as directed. |
| 28 | M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified ) |
| 29 | M & L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately. |
| 30 | S&F Anodised aluminum powder coated (of any shade/colour as approved by GE ) ventilators with adjustable 4mm thick figured glass louvers, fixed in half portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm including complete etc all as specified and directed by the Engineer-in-charge (Size of Ventilators = 500x850 mm) |
| 31 | M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 32 | Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden /steel /aluminium /rubber beading in square not exceeding 0.5 Sqm in each pane and all as specified. |
| 33 | Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil or in wooden /steel /aluminium /rubber beadingputty in square exceeding 0.5 Sqm in each pane and all as specified. |
| 34 | Supply & fix stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed fixed. |
| 35 | M&L preparing new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed |
| 36 | M & L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces |
| 37 | S & F Butt hinges stainless steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed |
| 38 | S & F Butt hinges medium weight, cold rolled mild steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed |
| 39 | S&F Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed |
| 40 | S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed |
| 41 | S&F 125 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed |
| 42 | S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed |
| 43 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed |
| 44 | S & F 140 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed. |
| 45 | S&F mild steel 300mm, ordinary rat tail rod pattern springs,including roller and roller plate complete |
| 46 | S & F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm fixed with MS screw or nut bolts with or without wooden or steel beading in repairs all as specified and as directed. |
| 47 | S & F in repairsAluminium anodised barrel towel bolts of extruded section of length 200 mm all as specified and as directed. |
| 48 | S & F in repairs Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections including taking down old sliding door bolt 300 mm all as specified and as directed. |
| 49 | S & F in repairs Extruded alloy handles fabricated type anodised of size 150 mm all as specified and as directed. |
| 50 | S&F in repairs Butt hinges medium weight cold rolled mild steel of size of hinges 100mm |
| 51 | S & F in repairs 140 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed. |
| 52 | S&F in repair mild steel 300mm, ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and as directed. |
| 53 | S & F in repairs 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work,alround 6mm th teak fillets fixed in kitchen Cabinet or cupboards all as specified. |
| 54 | M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood fixed to cupboard shutter including taking down old fillets exc 13 & n exc 25 sqcm cross section area all as specified and directed. |
| 55 | S&F Continuous (piano) hinges 30mm width of flaps (when open) , mild steel, bright finish or electro galvanised |
| 56 | S&F 100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws. |
| 57 | S&F Magntet door catcher made of main body magnet of stainless steel including iron striking plate of size 60x30x10 mm in size complete all as specified and directed |
| 58 | S & F 40 mm dia cupboard knobs fixed with nut, screw and washer of Brass,polished complete all as specified and as directed. |
| 59 | S&F in repairs stainless steel decorative curtain rod of 20 mm bore with wood finishes (weight not less 300 gms per running meter) incl fancy finale caps cap etc complete all as specified and as directed |
| 60 | S&F in repair Bracket for curtain rod of dia 20 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long incl wooden base etc complete all as specified and as directed |
| 61 | M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,including cutting and polishing laid on 15 mm thick screed bed in CM 1:4 set and jointed including dismantling of old stone slabs laid bedded and pointed in any mortar complete all as specified |
| 62 | M & L for Providing edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete |
| 63 | S & F in repair kitchen sink with drainage board made of stainless steel 1mm thick kitchen or laborotry with plugs, washers and wastes including bedding in mortar on to dwarf wall or including fixing cantilever brackets and connecting union pipes overall size 915x460mm bowl size 410x330x160mm complete. |
| 64 | S&F in repairs stainless steel plate rack of 0.63mm thick sheet, size 800mm x 600mm complete all as specified and as directed |
| 65 | S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including 32 mm dia brass waste coupling ,15 mm dia chromium plated fancy type pillar taps, waste pipe, 600 mm long PVC connection & brackets including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing & supply and waste pipe.complete all as specified and as directed |
| 66 | S&F in repair Vitreous china wash down water closet pan ( pedestral Pattern) white, (Including flushing cistern and flush pipe) , including connection to drain & or out going pipe) and to flushing pipe, anti syphonage pipe, seat and cover for pedestral pan including PVC flushing cistern and 450 mm long PVC connection etc. complete all as specified and as directed |
| 67 | S&F 15mm stop valves cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions and fixed in repairs.complete all as specified and as directed |
| 68 | S&F 15mm stop valves/ angle valves cast copper alloy, screwed down, high pressure, fancy type,chromium plated screwed both ends for iron pipe or for unions and fixed in repairs. |
| 69 | S & F chromium plated long body bib tap 15mm dia with CP flange as fixed in repair all as specified and as directed. |
| 70 | S & F chromium plated swan neck adjustable & rotational type kitchen sink tap 15mm dia with CP flange as fixed in repair all as specified and as directed. |
| 71 | S&F in repair chromium plated 15mm dia with CP flange two way bib cock with angle valve combination all as specified and as directed. |
| 72 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position in all respect as specified. |
| 73 | S&F125mm dia brass chromium plated shower rose with swivel joints fixed in repairs . |
| 74 | S & F in repairs Towel rail stainless steel glossy finish, D type 20 mm dia and 600 mm long complete all as specified and as directed. |
| 75 | S & F in repairs Towel ring stainless steel glossy finish, circular type minimum 5mm thick and 15 cm dia complete all as specified and as directed. |
| 76 | S&F in repairs Soap dish chromium plated brass all as fixed in wall as per manufacturers instruction. |
| 77 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on PVC sheet and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified |
| 78 | S & F in repair 75mm dia PVC(SWR) floor trap,plain with grating including jointing with slvent cement all as specified and as directed. |
| 79 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 80 | M&L for Pre-cast cement concrete block masonry, Type C1 1:3:6 (20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:4 , complete etc complete all as specified and as directed |
| 81 | Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 82 | M & L cement concrete type B0 1:2:4 (12.5 mm graded stone aggregate) 25mm thick finished even as in levelling concrete for floor. |
| 83 | Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises. |
| 84 | M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 20mm thick screed bed of CM 1:4 etc. complete as specified and directed. |
| 85 | M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes all as specified and as directed. |
| 86 | M & L Glazed ceramic tiles in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & incl 10mm thick in screed CM 1:4 on brick work or concrete surfaces to receive wall tiles all as specified and as directed. |
| 87 | Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed. |
| 88 | M&L for Rendering 15mm thick in CM 1:6 on brick or concrete surfaces , finished even and smooth with out using extra cement. (Internal Surfaces) |
| 89 | M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement (External Surfaces)Note :- WPC will be measured and paid separately |
| 90 | Supply only liquid water proofing compound |
| 91 | M&L for Rendering 5 mm thick in CM 1:3 on ceiling surfaces , finished even and smooth with out using extra cement. |
| 92 | Preparation of new plastered surfaces and applying three coats of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed. |
| 93 | M & L for Preparation of newly plastered surfaces of wall/chajjas etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed. |
| 94 | M & L for Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper over one coat of primer over one coat of 1 mm thick wall care putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed. |
| 95 | Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wood and wood based surfaces over 10cm width or girth all as specified and as directed. |
| 96 | M & L for Complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed. |
| 97 | M & L for Complete removal of existing treatment on walls of any description over 10cm girth or width and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over one coat of 1 mm thick wall care putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed. |
| 98 | Preparation of old decorated of surfaces and applying one coat of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed. |
| 99 | M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and as directed by Engineer -in-Charge. |
| 100 | M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1Ltr SBR+1Ltr) water+3kg cement), complete all as specified and as directed by Engineer -in-Charge. |
| 101 | M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 50 to 100 mm from columns, beams and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and as directed by Engineer -in-Charge. |
| 102 | M&L for applying one coat of anti corrossive primer @ 0.25 Lit/Sqm for the steel area to exposed old and new reinforcement to the full circumfrance and length of bars to form unbroken 40 Micron thick film all as specified and directed by Engr-in-Charge. |
| 103 | M&L for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces all as specified and directed by Engr-in-Charge to surfaces of columns, beams and similar structural members all as specified |
| 104 | M&L fair finished flat Form work to RCC columns, posts and similar items including edges |
| 105 | M&L for non shrink, cementitous micro concrete mixed with 12.5 graded stone aggregate using Renderoc RG or equivalent by weight (18 Kg aggregate :25 Kg Renderoc RG) respectively (as per manufatures instruction) laid in average thickness 80 to 100 mm in situ all as specified |
| 106 | M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified. Make : Concure WB white of Fosroc. |
| 107 | S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floors including necessary fittings all as specified and as directed. |
| 108 | All as per item No. 107 above but for 110 mm dia . |
| 109 | S&F in repair 75mm dia PVC (SWR) Bends with access door of any radious |
| 110 | All as per item No. 109 above but for 110mm dia |
| 111 | S&F in repair 75mm dia PVC (SWR)branch piece, double (double Y) equal or unequa with access door |
| 112 | All as per item No. 111 above but for 110mm dia |
| 113 | M&L for PCC 1:3:6, type C2, (Using 40 mm graded stone aggregate), 75mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed. |
| 114 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 115 | Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade concealed ISI marked incl accessories incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium/heylam plat, iron screws , housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :-One light point controlled by one switch |
| 116 | All as per item No. 116 above but forOne fan/exhaust point controlled by one switch/regulator |
| 117 | All as per item No. 116 above but forOne 3 pin socket out let 5 Amps on independent board |
| 118 | All as per item No. 116 above but forOne bell/buzzer point controlled by bell push |
| 119 | All as per item No. 116 above but forOne 3 pin socket out let 5 A on same board |
| 120 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade concealed ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium/heylam plat, iron screws , housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 115 to 120 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items. |
| 121 | S&F in repair LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed. |
| 122 | S&F in repair LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as specified and directed. |
| 123 | Supply and fix in repair Slim surface mounted round LED down lighter of 12 watt aluminium die cast body with premium diffuser to ensure glare free & even distribution of light. |
| 124 | Supply and Fix Modular switch 1 way 6A,1 module |
| 125 | Supply and fix Modular switch 1 way 16A, 1 module |
| 126 | Supply and fix Modular switch 2 way 6A,1 module |
| 127 | Supply and Fix Modular Bell push 6A 1 module |
| 128 | Supply and fix modular Socket, 6A - 2/3 pin combined 2 module |
| 129 | Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 130 | Supply and fix modular type Fan step regulator, 120W - 2 module |
| 131 | S&F in repair of Angle holder PVC / polycarbonate type all as specified and as directed |
| 132 | S&F in repair MCB SPN 240 volts 32 Amps complete all as specified and as directed |
| 133 | S&F in repair MCB single pole 240 volts 6 to 32 Amps complete all as specified and as directed |
| 134 | S&F in repair MCCB 4 pole 415 volts 100 Amps 16 KA, fixed type complete all as specified and as directed |
| 135 | S&F in repair MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 136 | S&F in repair Vertical DB (Optium F1 + 18) suitable for MCCB upto 125 Amps and 18 no of outgoing MCB as I/C, double door type 415 volts, IP :54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly |
| 137 | S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 138 | S&F Ding Dong bell AC 230 volts single pole. |
| 139 | M&L in repair for provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit conceled type all as specified and as directed. |
| 140 | M&L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.incl dismantling and taking down of old earthing. |
| 141 | Supply in repair and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. |
| 142 | S&F in of exhaust fans motor upto 300 mm sweep, heavy duty, 1400 RPM, AC single phase 90 W, 230/240 V with blades complete all as specified and directed.Make : Bajaj cat no SUPREME PLUS 300 mm or CG/Havells/Khatian equivalent make. Please Enable Macros to View BoQ information |
| 143 | S&F in of exhaust fans motor upto 300 mm sweep, heavy duty, 1400 RPM, AC single phase 90 W, 230/240 V with blades complete all as specified and directed.Make : Bajaj cat no SUPREME PLUS 300 mm or CG/Havells/Khatian equivalent make. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy