| 1 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. liad in any type of motar all as specified and directed. |
| 2 | M & L Cement concrete type B0 1:2:4 (12.5 mm graded agg) 25mm thick as in sub floors |
| 3 | M & L for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 all as specified and directed. |
| 4 | M&L for Vitrified Ceramic tiles 10 mm thick Colour dark shade (square/rectangular) polished, area of each tiles exc .18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 5 | M&L Vitrified Ceramic tiles Light Shade 10mm thick (square/rectangular) polished as in Vertical Surface/Dado/Skirting etc set and jointed in neat cement slury and pointed in coloured cement to match over 10mm thick backing Coat in CM 1:4 complete all specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | M & L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all specified and directed. |
| 8 | M&L Glazed Ceramic Coloured Tiles, 450x300/300x600x7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. |
| 9 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incluidng rubbing and polishing complete including screed bed 20mm thick in cement motar 1:4 complete all as specified and directed. |
| 10 | M & L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with over a 10mm thick plaster in CM 1:3 all as specified and directed. |
| 11 | M&L granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade |
| 12 | Demolition of cement concrete (un-reinforced) in ground floors and paving's not exc 15 cm thickness (below or above ground level) |
| 13 | M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate as in sub base of floor and path, plinth protection etc.complete all as specified and directed. |
| 14 | M&L Forming Contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection |
| 15 | Dismantling roof treatment of any description in suspended slabs in roofs,suspended floors, chajjas, landings etc,including cement mortar bedding,padding concrete and rubbish of premises complete all as directed. |
| 16 | Cleaning the surface by roughening, sweeping clean and washing down and applying cement slurry @ 3 kgs/sqm |
| 17 | M&L cement concrete type B-1 1:2:4 (using 20mm graded stone aggregate) as in RCC roof surface with mixing of water proofing compound to horizontal or vertical surfaces finished cement concrete surface even and smooth including necessary form work (Water proofing compound will be measured separately) |
| 18 | M & L for 10mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. including water proofing compund all as specified and directed.(Water proofing compound will be measured separately) |
| 19 | Supply only Liquid WPC |
| 20 | Applying Bitumen Primer conforming to IS-3384 applied @ 3 kg/Sqm and Providing 3mm thick Atactic Polypropyle Polymer(APP) modified water proofing membrane weighting not less than 3 kg/sqm reinforced with non woven polyester matt weighing not less than 150 gm/sqm and applying a coat of blown grade hot bitumen 85/25 over the mebrance @ 1.2 kg/sqm top of membrane surface shall then be finished complete all as per manufacturer instructions and as directed by Engineer-in-Charge. |
| 21 | Applying aluminium bitumen based paint complete all as directed by Engineer-in-Charge. |
| 22 | Taking down Shutters of description exc 1sq.m and n exc 2 sq. m each complete all as specified and as directed. |
| 23 | Taking down chowkat with shutter without taking out shutter from the frame n.exc 1.5 Sqm. |
| 24 | Taking down chowkat with shutter without taking out shutter from the frame exc 1.5 and n.exc 4 Sqm each |
| 25 | Taking down shutters of any description n exc 1 sq. m each. |
| 26 | Supply and fix for solid PVC door frame of size 50mm x 47mm, made out of 5 mm thick plain colour PVC sheet, reinforced with mild steel square tube complete all as specified and as directed. |
| 27 | Supply and fix for factory made solid Panel PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded Prelaminated PVC sheet on the front face and 2mm prelaminated colour PVC sheet on back face, fixed in frame at site as per specification and drawing including fittings complete all as specified and as directed. |
| 28 | S & F aluminium anodied powder coated frame ( miniumum thickness of powder coating 50 micron) for doors widnow, windows, ventilator with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 29 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (For Sliding Windwo shutters) |
| 30 | S & F 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and directed by Engr -in-Charge. |
| 31 | S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. |
| 32 | S&F 35 mm thick second class hardwood glazed and skeleton shutters divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers and prepared to receive glass, gauze, etc., edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauze, etc.complete all as specified and as directed. |
| 33 | S & F 30 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 34 | S & F 100 mm size butt hinges, medium weight, cold rolled brass complete all as specified and as directed. |
| 35 | S &F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed. |
| 36 | S &F 150mm long extruded aluminium alloy handlesfabricated type anodised all as specified and directed. |
| 37 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed. |
| 38 | S&F in repair galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 39 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm dia |
| 40 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 20mm dia |
| 41 | M&L for GI tubing 15mm dia medium grade with all fittings & fixed complete to walls & ceiling or laid in floors |
| 42 | Fixing only 15mm dia tubes, any grade, to walls and ceilings or laying in floors |
| 43 | M&L for GI tubing 20mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs |
| 44 | Fixing only 20mm dia tubes, any grade, to walls and ceilings or laying in floors |
| 45 | M&L for cutting chases, pinning in making good to face for concealed water tubing in stone concrete blocks or slab walls all as specified and directed. |
| 46 | Dismantling water tank exc 250 and n exc 500 ltrs and remvoing to all as specified and directed. |
| 47 | S&F Universal type three layers, white colour rotational moulded polyethylene water storage tank of 500 ltr capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge. |
| 48 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) , Pedestal pan and trap including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc complete, Plastic water closet seat, black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 49 | S & F Vitreous China wash basin (oval type), white, flat back, size 550x450 including waste, chain and plug and porcelain stopper but including brackets,450mm PVC connection with barass screws, waste coupling, 32 mm dia all as specified and as directed. |
| 50 | S & F in repair 10 Ltr PVC low level flushing system plastic valve with inlet ball valve float including brackets , flush pipes to pedestal pan , including all joints fixied in repair all as specified and directed. |
| 51 | S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers ® all as specified and directed. |
| 52 | S&F in repair 15 mm dia CP brass PVC connection 45 cm long including check nuts etc complete all as specified and directed |
| 53 | S&F in repair for 15 mm dia CP pillar cock, cast copper alloy complete all as specified and directed . |
| 54 | M&L in repair for 15 mm bore bib tap chromium plated cast copper alloy with wall flange complete all as specified and directed. |
| 55 | S & F in repair Angular stop cock with flange , cast copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed |
| 56 | S &F Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed |
| 57 | S &F Two way bib cock with wall flange 15mm dia all as specified and directed. |
| 58 | S & F wall mixter 3-in-1 system with provision for both hand shower and over head shower complete with 115mm long bend pipe connecting legs and wall flange (wihtout hand and over head shower) all as specified and directed. |
| 59 | S & F Corner glass shelf with brackets all as specified and directed. |
| 60 | S & F round 150mm dia shower all as specified and directed. |
| 61 | S &F Soap dish holder all as specified and dirrected. |
| 62 | S &F in repair brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and directed. |
| 63 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified . |
| 64 | S &F in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 65 | S & F stainless steel fancy type curtain rod 20 mm bore including fixing and two sides brackets all as specified & as directed. |
| 66 | Demolition and breaking up drain pipes (Salt glazed ware /PVC/ AC or Reinforced concrete) set in cement mortar (100mm dia) |
| 67 | S & F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or in trenches or in floor all as specified and directed. |
| 68 | S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or in trenches or in floor all as specified and directed. |
| 69 | S &F PVC (SWR) bends with oval acess door 75mm dia |
| 70 | S &F PVC (SWR) bends with oval acess door 100mm dia |
| 71 | S &F PVC (SWR) cowls of 75mm dia |
| 72 | S & F PVC (SWR) reducers 75mm dia |
| 73 | S &F 110mm PVC (SWR) junction single (Single T) equal or unequal with acess door |
| 74 | S &F 75mm PVC (SWR) junction single (Single T) equal or unequal with acess door |
| 75 | S &F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.(Window Grills) |
| 76 | Taking down cement plaster on brick/stone wall etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 77 | M & L rendering 15mm thick on surface of brick work/concrete surface in CM 1:6 and is to be finished even and smooth with out using extra cement complete all as specified directed |
| 78 | M & L for 10mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. |
| 79 | M & L for 5mm thick ceiling cement plaster in CM 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. |
| 80 | Demolition of Brickwork or stone/boulder masonry/PCC bloack masanory, built in cement motar all as specified and directed. |
| 81 | M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) with 20mm aggregate and set in CM (1:6). |
| 82 | M & L for Preparation of new wooden surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paint over pink primer for material and labour complete. |
| 83 | Complete removal of existing treatment on walls all as specified and directed. |
| 84 | M&L for 1mm thick wall care putty on wall all as specified and directed by Engr in Charge. |
| 85 | M & L for distmepring with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved munufacutre of required shade and colour complete as per munufacuters specification two or more coat on new work all as specified and directed. |
| 86 | M & L for Preparation of old plastered surfaces/un plastered surfaces including brooming down with steel wire brushing scrapping down smoke spout moulds, moss and efflorescence, salt treating oil and greasy spots etc and applying two coat of white washing on old plastered surfaces of walls all as specified. |
| 87 | All as per ser item No 1 above but on surface of on ceiling /soffits of slabs, chajjas all as specified and as directed at site. |
| 88 | M & L for Preparation of old painted steel/iron surfaces of any description having width/girth exceeding 10cm and applying one coat of synthetic enamel paint for material and labour complete. |
| 89 | M & L for Preparation of new steel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paint over red oxide primer for material and labour complete. |
| 90 | S &F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof (75mm dia) |
| 91 | S &F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof (100mm dia) |
| 92 | Demolition of concrete of any description and in any position not othewise specifically provided for sunken treatment all as specified and directed by Engineer in Charge. |
| 93 | M&L for 75mm thick PCC in (1:2:4) type B2 using 40mm graded stone agg as in sunken floor complete all as specified and as directed |
| 94 | M&L for PCC 1:5:10 type E2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as directed |
| 95 | M&L for PCC 1:1½ : 3 or Bitumastic Gola with 80/25 bitumen and coarse sand mixer 1:3 by weight 8cm x8cm at the junction of roofing to vertical surface as in sunken or similar work complete all as directed |
| 96 | M&L for Bitumen blown any grade applied hot, two coats to concrete bedding surface @ 1.5Kg/Sam(VG-10 grade) per coat as in sunken floor complete all as directed |
| 97 | M&L for polythene flim black 50 micron laid in sunken floor complete all as directed |
| 98 | M&L for spout of 50mm bore PVC pipe and projection 450mm clear from outer wall in any length or description with rubber ring joints and fixed in sunken floor etc for drain out logging as in sunken floor etc or similar work complete all as specified and as directed |
| 99 | M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone agg as in sunken floor mixed with water proofing comound finished fair and even complete all as specified and as directed (Note:- WPC shall be measured and paid separately) |
| 100 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 5km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed |
| 101 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frame work, stone, concrete or brick surrounds, glazed with putty or fixed with beadings. |
| 102 | S&F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sq mtr in each pane complete all as specified and as directed. |
| 103 | Dismantling wooden boarding, any description, fixed in any position with screws complete all as specified and directed . |
| 104 | S&F in repair 18/19 mm pre- laminated particles board exterior Gde, pre-laminated one side with decorative choice lamination & other side balancing white laminateion fixed with screws to timber frame work. (for Kitchen cabinets/cupboards / shelves and similar works) |
| 105 | M/L for 2nd class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in 2nd class H.W. sectional area n. exc. 6 Sqcm. |
| 106 | S/F butt hinges 75mm extruded brass with MS hinges pin, bright polished and fixed type D-11 |
| 107 | S/F brass cup board lock 75mm size 4 level with duplicate keys |
| 108 | S/F brass handles extruded fabricated type 100mm size. |
| 109 | M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed. |
| 110 | Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. |
| 111 | Taking down Ceiling fan any size or any type and deposited to MES store yard complete all as specified and directed. |
| 112 | Taking down Exhaust fan any size or any type and deposited to MES store yard complete all as specified and directed. |
| 113 | Taking down old Electric Meter of any type and deposited to MES Store Yard complete all as specified and directed. |
| 114 | Taking down old and unserviceable submain wiring any size /type including earth wire complete with batten/conduit etc complete all as specified and directed |
| 115 | Taking down old Water Heater (Geyser) any type/Size/Capacity with all accessories after removing of all incoming/outgoing pipe line connection and deposited to MES Store Yard for repair complete all as specified and directed. |
| 116 | Taking down old unserviceable VPTN MCCB DB/MCB TPN DB/MCB SPN 12 way any of size/capacity complete all as specified and directed. |
| 117 | Taking down old unserviceable MCB SPN/MCB SP of any size/capacity complete all as specified and directed. Please Enable Macros to View BoQ information |
| 118 | Taking down old unserviceable MCB SPN/MCB SP of any size/capacity complete all as specified and directed. Please Enable Macros to View BoQ information |