| 1 | Auditorium |
| 2 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 7 | 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 8 | OD369154/2025-2026:Providing and fixing precoated galvanised iron profile PUF sheets (size,shape and pitch ofcorrugation as approved by Engineer-in-charge)30mm over all thickness and external faceconsists of 0.4mm and internal face consists of 0.30mm thick sheets having total coatedthickness with zinc coating 120 grams per sqm as per IS :277, in 240mpa steel grade,5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns . Sheetshould have protective guard film of 25 microns minimum to avoid scratches duringtransportation and should be supplied in single length upto 12 metre oras desired by Engineerin-charge.The sheets are sandwiched with a core which is an insulated panel and is made ofpolyurethane PIR mineral wool. The sheet shall be fixed using self drilling/self tapping screwsof size(5.5x110mm) with EPDM seal ,complete upto any pitch in horizontal/vertical or curvedsurfaces ,excluding the cost of purlins rafters and trusses and including cutting to size and shape where ever required |
| 9 | OD369153/2025-2026:Supplying and fixing GI ridge capping using 0.40mm thick PUF sheets or nearest including SSscrews, plain and bitumen washers etc all complete |
| 10 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 11 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 12 | OD369155/2025-2026:200 mm uPVC square rain water gutter ,uPVC gutter clamp,uPVC end cap,joints |
| 13 | 50.18.9.19.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall |
| 14 | OD369156/2025-2026:od1288959/2021_2022 :Designing, fabricating,testing and installing Curtain Wall with Aluminium CompositePanel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heightsand all levels etc. including:Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding INCLUDINGaluminium base frame work in pan shape in metalic colour of approved shades made out of 3mm thickaluminium composite panel material. The aluminium composite panel cladding sheet shall be coil coated,with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade onface # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc.with aluminium composite panel cladding till thehanding over of the building for occupation. The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete, as per the Architecturaldrawings, as per item description, as specified, as per theapproved shop drawings and as directed by theEngineer-in-Charge.However, for the purpose of payment, only the actual area on the external face of thecurtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm.up to two decimal places.OD86/21-22 - Modified data 25.7 |
| 15 | OD369157/2025-2026:Supplying and fitting stainless steel (grade 304) 3D lettering MALAYALAM of size 10-15 cm,20-30 mm projection etc.complete as per direction of engineer in charge at site Please Enable Macros to View BoQ information |