Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-03-2026 | Pre- Bid Meeting Corrigendum | Date | 01-04-2026 |
| Sl. No. | Item Description |
| 1 | Earthwork |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in- charge. |
| 6 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock |
| 7 | Supplying and filling in plinth with sand under floors, including watering, ramming consolidating and dressing complete. |
| 8 | Concrete Work |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted withfine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 13 | Providing and laying damp-proof course of 150 mm thick with Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size )including the cost of centering, shuttering, finishing , reinforcement and mixing water proofing material in cement concrete work etc complete. |
| 14 | Supply, spreading and proper fixing of low density polyethylene (LDPE) sheet having minimum 500 micron thickness and greater tear strength over compacted and leveled base course by lapping 200mm on all joints including all required as per the instruction of Engineer In Charge. |
| 15 | Pile work |
| 16 | Boring,providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 with minimum cement content 350kg/cum of specified diameter and length below pile cap as per structural drawing to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.by using hydraulic rotary drilling all complete,including chipping of pile,socketing,removal of excavated earth with all its lifts and leads(length of pile for payment shall be measured up to bottom of pile cap). 750 mm dia piles |
| 17 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile 135 tonne capacity Initial test (Test Load 2.5 times the Safe capacity) |
| 18 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile 135 tonne capacity Routine test (Test Load 1.5 times the Safe capacity) |
| 19 | Reinforced Cement Concrete |
| 20 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fineaggregate derived from natural sources, Ordinary Portland cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 21 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 22 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cementcontent of 350 kg /cum |
| 23 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/ Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work above plinth level upto floor V levelConcrete of M30 grade with minimum cement content of 350 kg /cum |
| 24 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 25 | 1:2:4 (1 cement : 2 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 4 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20%). |
| 26 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 27 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 28 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 29 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 30 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 31 | Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 32 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 33 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 34 | Anti termite treatment over finished earthen floor before 3-15 hrs of concreting by applying ATT solution using quality sprayers in prescribed ratio as recommended by the manufacturer including supply of AT solution, Application, Covering of applied surface for 2 hrs with polythene sheet etc all required as per the instruction of engineer in charge. |
| 35 | Brick work |
| 36 | Laterate masonry with neatly dressed laterate stone of size 35x20x20 cm or nearest size in cement mortar 1:6 of minimum compressive strength 7 N/mm2 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. |
| 37 | Laterate masonry with neatly dressed laterate stone of size 35x20x20 cm or nearest size in cement mortar 1:6 for superstructure above floor two level upto floor five level including all cost of materials, labour charges etc. |
| 38 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete |
| 39 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 40 | finishing |
| 41 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 42 | 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand) |
| 43 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 44 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 45 | 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 47 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 48 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 49 | Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 51 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 52 | Wood work and PVC work |
| 53 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 54 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. |
| 55 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 56 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). |
| 57 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 58 | Providing and fixing steel door with frame made of min 1mm thick GS Sheets with overall shutter thickness of minimum 35mm finished with thermosetting polyurethane pain of aliphatic grade of approved shade and colour as per the instructions of the engineer in charge with all necessary fitting arrangements including SS Tower Bolt, SS Hinges, Bump Ons, Shims, Hole Caps, Anchor Bolt, Knob Lock/Lever Lock etc. Door Frame to be of same shade of the door shutter and to be fixed with all necessary fixing arrangements. The colour and design of the door to be as per the instructions of the engineer in charge. |
| 59 | Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall opening size 1200mm x 2100 mm |
| 60 | Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm.8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. |
| 61 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) |
| 62 | Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. |
| 63 | Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete |
| 64 | Providing and fixing of Stylam Cuboid make toilet cubicles of the following dimensions. Depth 1500mm, Width 1200mm, Height 1980- 2000mm which includes door size of 600mm width x 1830mm height, made up of thermosetting resin treated high pressure, self supporting decorative compact laminate with permanently incorporated anti-bacterial agent during manufacturing. Compact board shall be resistance to water immersion through permissible increase on weight 0.60-0.80% and board density 1.40kg/cm3 and manufactured as per EN 438 IS 2046 standard. 12mm thick compact board should be Moisture resistance, Impact resistance, Termite resistance, Scratch resistance, Weather and climatic shock resistance. Finish of the compact laminate should be of suede finish , which includes door, pilasters intermediate panels, finished with approved texture/shades as per IS 2046 and fulfil the criteria of fire retardant under BS1D0 standard. Pilaster to be supported with SS (grade 316) adjustable foot and the immediate panel will be attached to the wall with the help of SS (grade 304) U channels made up of Stainless Steel as per manufacturers specification. This also includes providing fixing in position necessary hardware made-up of Stainless steel(grade 304) as per manufacturers specification architects instruction like (1) Door Knob .( 2) Gravity Hinges (3)Thumb turn lockset with occupancy indicators (4)Coat Hook with Door stopper (5) U Channels of size 21mmx16.4mmx0.8mm , (6) Adjustable Legs/Pedestals ( SS grade- 316) (7) Rectangle type SS top rail 55mmx42mm which will get fixed with Mid and end pilaster. All the screws shall be SS (grade 304). All the pilasters are supported by SS (Grade -316) adjustable foot. The base of the stainless adjustable foot will be anchored to the floor with a clearance height up to 100-150mm. The colour, Shade, finish of the Toilet cubicles should be approved by the architect/ Engineer in-charge. |
| 65 | Cabinet/Wardrobe: Providing and errection of Cabinet/Wardrobe unit made with 18 mm thick prelaminated MDF board of one side decorative lamination and other side balancing lamination having total unit dimension of 900mm,L x 450mm,Dx 2400mm,H and all edges to be sealed with PVC edge beeding of 2.00 mm thick including all fittings such as autoclose hinges,chromium plated brass individual locks handles ,tower bolts etc all required. All shelves to be fix with proper support and bracket holders at a spacing of 400 mm centre to centre and all as per the drawings and instruction of Engineer in charge. board make : Greenlam/ Merino / Century/ equivalent . Only front elevation will be measured. |
| 66 | Sanitary installation |
| 67 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern |
| 68 | Providing and fixing ceramic urinal partitions of standard size (700mm*600mm) as per direction of Engineer-in Charge and of approved shade |
| 69 | Providing and fixing counter top wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous counter top wash basin of minimum size 485x310x130mm. |
| 70 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 71 | Providing and fixing uplasticised PVC connection pipe with brass unions: 30 cm length15 mm nominal bore |
| 72 | Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 73 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter |
| 74 | Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore |
| 75 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 76 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm |
| 77 | Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. |
| 78 | Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 79 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia |
| 80 | Providing and fixing white vitreous china wall mounting rimless water closet of min dimension 490 x 350 x 360 mm, including concealed tank with frame, Pneumatic system, Flush Plate and all necessasry fittings etc complete. as per the Engineer in charge. |
| 81 | Providing and fixing 1800 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. |
| 82 | Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. |
| 83 | Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . |
| 84 | Water supply |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal dia pipes |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal dia pipes |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal dia pipes |
| 90 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 91 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 92 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 93 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall |
| 94 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall |
| 95 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 96 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow |
| 97 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 98 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer |
| 99 | Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. |
| 100 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 |
| 101 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 102 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend |
| 103 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 104 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 105 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap |
| 106 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 107 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 108 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 109 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 110 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 111 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 112 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 113 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer |
| 114 | Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 115 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 116 | Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 117 | Providing & Fixing GI pipes complete with GI fittings and clamps including making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall:20 mm dia nominal bore |
| 118 | Providing and fixing a 100 mm dia .GI puddle flange for outlet in all types of water tanks is complete |
| 119 | Providing and fixing a 50 mm dia. GI puddle flange for outlet in all types of water tanks is complete. |
| 120 | Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg |
| 121 | Supplying, filling, spreading leveling gravels of size 40 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads lifts, all complete as per direction of Engineer -in-Charge |
| 122 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 123 | Yard Plumbing |
| 124 | Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 125 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 |
| 126 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 127 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm |
| 128 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm bend |
| 129 | Flooring |
| 130 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. |
| 131 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement matching pigments etc. complete.Size of Tile 1200x600 mm |
| 132 | Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. |
| 133 | Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement matching pigments etc. complete. Size of Tile 600x600 mm |
| 134 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 135 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 136 | marble and granite work |
| 137 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 138 | Extra for providing opening or required size shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 139 | Granite work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm |
| 140 | Providing and fixing 18 mm thick gang saw cut, mat /rough finished granite machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. br Area of slab over 0.50 sqm |
| 141 | Steel work |
| 142 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes |
| 143 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 144 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 145 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 146 | Roofing |
| 147 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 148 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 149 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. |
| 150 | Providing fixing Poly carbonate multi wall plain sheet 6 mm thick both side UV coated as approved by the Engineer in charge and should be supplied in a single length of 12m or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size (5.5x55mm) with accessories such as aluminium skylighting profiles, top and bottom sealant, screws complete upto any pitch in horizontal/vertical curved surfaces, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. |
| 151 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 152 | Water proofing |
| 153 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 154 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 155 | Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 156 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm |
| 157 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. |
| 158 | Signage |
| 159 | Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. |
| 160 | Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. |
| 161 | Structural glazing and aluminium composite panel |
| 162 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work.Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment |
| 163 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. |
| 164 | Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr? 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml? 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test? Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml |
| 165 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement |
| 166 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 - point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. |
| 167 | Backlit Acrilic Board with projected letters: Supply, installation, testing and commissioning of weatherproof backlit acrilic board with projected letters made upof 20mm thick acrilic board and having box depth of min 100mm in approved size and design with reqired LED strips for high glow light. The board shall be fabricated and fixed over suitable welded and painted 25X25X3mm MS angle frame in suitable location and in proper line and level with all necessary fastners, supports etc.Electrical works likes electrical wirings, connections, fittings, externaly fixed weather proof 2/3 pin plug points and sockets including boxes etc. to be complete properly.All fabrication and fixing should be done as per approved design and instructions of Engineer in Charge. (Note: Only front elevation will be measured.) |
| 168 | Drainage |
| 169 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.With 20x20 mm square bar |
| 170 | Road work |
| 171 | Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 172 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 173 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 174 | Wiring |
| 175 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 176 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 177 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 178 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 179 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 180 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 181 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 182 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire |
| 183 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 184 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 185 | Sockets |
| 186 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 187 | Supplying and fixing following modular switch/ socket on the existing modular plate switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 188 | Supplying and fixing following modular switch/ socket on the existing modular plate switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 189 | Supplying and fixing following modular switch/ socket on the existing modular plate switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 190 | Supplying and fixing following size/ modules, GI box alongwith modular base cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 191 | Supplying and fixing following size/ modules, GI box alongwith modular base cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 192 | Supplying and fixing following size/ modules, GI box alongwith modular base cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 193 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 194 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 195 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. lCD |
| 196 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 197 | DB and Switchgear |
| 198 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 199 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) |
| 200 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) |
| 201 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 202 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 203 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 204 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 205 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 206 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 207 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 208 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 209 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 210 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 211 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 212 | Providing and fixing 40 Amps, 4 Pole MCB type Change Over Switch (COS), 415V, 50Hz, suitable for three phase AC supply, conforming to IS/IEC 60947-3, with center OFF position, positive manual operation, quick make and break mechanism, high short circuit withstand capacity, complete with copper terminals, shrouds, suitable for mounting in enclosure, including all necessary internal connections with suitable size copper conductors, testing, earthing and commissioning complete as required at site. |
| 213 | Providing and fixing identification numbering/labels for DBs, panels and electrical equipment using durable vinyl stickers or painted lettering of size 10/20 mm as required, indicating the name/number of the panel or distribution board, neatly fixed on the surface with proper alignment and finishing, complete as required and as directed by the Engineer-in-Charge. |
| 214 | Supply, installation, testing and commissioning , Preparation and submission of scheme drawings and necessary documents, liaisoning with the Electrical Inspectorate, arranging and conducting inspection, and obtaining energisation certificate from the Electrical Inspectorate. of Machine Room Less (MRL) Passenger Lift conforming to CPWD General Specifications for Electrical Works Part-III (Lifts Escalators) of minimum 20 passenger capacity (1360 kg), speed 1.0 m/s, electric traction type with gearless PMSM traction motor with flat belt drive and regenerative drive technology, suitable for operation on 415 V &+/- 10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency (VVVF) microprocessor-based traction control, electromagnetic brake system, simplex collective operation, automatic centre/side opening stainless steel doors, matte finish stainless steel car enclosure with stainless steel handrails on three sides, 2 mm fluted stainless steel flooring, operating panel with luminous buttons, braille buttons, LCD/LED car position and direction indicator in car and at all landings with UP/DOWN direction indication, overload warning indicator, battery operated alarm bell, LED type emergency light, infrared ray sensing full-height door protection, reverse phase relay on controller, fireman’s switch at initial landing floor, audio announcement system with recorded message as approved by the Engineer-in- Charge, complete with Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance-free sealed SMF batteries and Manual Emergency Rescue Device, shaft wiring, lift lighting and all electrical components with wiring from the single point power supply provided at the top landing near the elevator door, complete as required. The drive system shall comply with IEEE 519:2014 for harmonic control, and the PMSM motor shall have efficiency equivalent to IE3 or better as per IS 12615. Lift suitable for 4 stops and 4 openings with entry and exit on the same side, for travel height approximately 18 m, suitable for shaft size 2400 mm (W) x 3200 mm (D) with door opening 1100 mm (W) x 2100 mm (H). The equipment shall be BMS compatible, and all components, fabrication and procedures shall conform to relevant IS codes, BIS standards and CPWD specifications, complete in all respects including submission of test reports from NABL accredited testing laboratories, as required and as directed by the Engineer-in- Charge. |
| 215 | LT Cabling and Terminations |
| 216 | Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation125/109 mm or nearest size |
| 217 | Supply laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm |
| 218 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm |
| 219 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm |
| 220 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 221 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 222 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 223 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 224 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 225 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 226 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp |
| 227 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) |
| 228 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 229 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 50 sq. mm |
| 230 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 231 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 232 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 233 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 234 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 235 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 236 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) |
| 237 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 238 | Locating the existing underground electrical cable within the premises of TRC using an electronic Cable Route Sensor/Cable Locator system for accurate detection and marking of the cable route, and shifting of the cable alignment, followed by careful excavation of trench up to 80 cm depth along the identified route, lifting and rerouting of the existing underground power cable up to 400 sq.mm size, relaying the cable in the new alignment with proper dressing, providing sand cushioning below and above the cable, covering with protective bricks/brick tiles and warning tape, and thereafter backfilling the trench with excavated soil in layers including proper compaction, dressing of the surface, and making good the disturbed area, complete as required and as directed at site. |
| 239 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185 sq. mm |
| 240 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 240 sq. mm |
| 241 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 300 sq. mm |
| 242 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 400 sq. mm |
| 243 | Supply installation, testing and commissioning of following three phase to three phase UPS with battery backup, indoor (IP20) with surge protectionsystem in stand alone configuration, true online doubleconversion DSP based UPS system, with min 30 min backup battery with, input pf>0.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and. The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 20kVA Double conversion online UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc. |
| 244 | Cable trays |
| 245 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness |
| 246 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness |
| 247 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness |
| 248 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness |
| 249 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 250 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 251 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 252 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 253 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 254 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 255 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 256 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 257 | Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray \\"bends\\" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150mm width X 50mm depth X 1.6mm thickness |
| 258 | Earthing |
| 259 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 260 | Providing and fixing 25 mm X 3 mm copper strip on surface/Cable tray or in recess for connections etc. as required. Rate to include cost of suitable GI clamps SS hardware, making welded joints etc all complete with. No holes shall be drilled to the conductor for clamping purpose |
| 261 | Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt spring washer spaced at 50mm) including excavation and refilling |
| 262 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) |
| 263 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 264 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 265 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 266 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 267 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 268 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 269 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 270 | Lightning Arrestor |
| 271 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminum rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load.All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination; Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminal for mounting: tripod stand or 3 no's and 4 no's respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate requireda) 3 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories |
| 272 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (EAlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate requireda) Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters |
| 273 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (EAlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate requiredb) Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters |
| 274 | Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece with Connector: to route vertical down conductor /mesh formation made of Aluminum Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalizing temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanized Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required |
| 275 | Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements according to (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required |
| 276 | Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required |
| 277 | Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm. Govt approved Indian labs test certificate required. |
| 278 | Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 2500mm length (8.20 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous arrangement with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding.Stainless steel Clamp for Bonding. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 15 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 209mm. Govt approved Indian labs test certificate required. |
| 279 | Street Lights |
| 280 | Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 281 | Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 282 | Solar Photovoltaic system |
| 283 | Supply, Installation, Testing and Commissioning of 10 kWp On-Grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Half-Cut / Bifacial Polycrystalline Silicon Solar Modules of 330 Wp or above (or suitable wattage to achieve 10 kWp capacity), manufactured in India and listed in MNRE ALMM, conforming to IS 14286/IEC 61215 and IS/IEC 61730 (Part 1 2), having minimum module efficiency of 16.5% with bifacial power generation capability, warranted for minimum 90% of rated output at the end of 10 years and 80% at the end of 25 years, complete with grid interactive String Inverter/PCU of suitable capacity having DC input range 350 1100 V and 400 V AC, 3 phase, 4 wire, 50 Hz (±2.5 Hz) output with efficiency not less than 97%, THD less than 3% and inbuilt protections including anti-islanding, over/under voltage and frequency protection, complete with web-based data monitoring system, IP-65 protected Array Junction Box (AJB) and Main Junction Box (MJB) with DC fuses, isolators and surge protection devices, lightning and surge protection system with dedicated earthing arrangement, and supplying laying of 1.1 kV grade XLPE insulated copper conductor armoured AC cables and UV resistant TUV certified DC solar cables with necessary cable trays/conduits, glands, lugs and all accessories, mounted on Aluminium/GI module mounting structure of adequate strength, including net metering arrangement, complete as required. |
| 284 | LT Panels |
| 285 | SITC Of LT Distribution Panel shall be a CPRI-approved, floor-mounted, indoor, compartmentalized, dust and vermin-proof panel fabricated from CRCA sheet steel with IP54 protection and epoxy powder coating, rated for 433V, 50Hz, 3-phase, 4- wire system. The panel shall have an incomer comprising 1 No. 320A 4P MCCB (25kA, thermal magnetic), RYB LED indication lamps with 2A fuses, 1 No. 0-400A digital ammeter with selector switch and CTs, 1 No. 0-500V digital voltmeter with selector switch, and 1 No. multifunction digital meter measuring V, A, kW, kVA, PF, and frequency. The outgoing section shall consist of 1 No. 200A 4P MCCB (25kA), 6 Nos. 63A 4P MCCBs (25kA), one of which shall be dedicated to solar applications and equipped with a reverse power relay to protect the system from any backfeed power, 1 No. 63A 4P isolator, and a separate multifunction digital meter with LED ON/OFF/TRIP indicators and 2A fuses for feeder status. The panel shall be provided with a 320A rated 4P extensible aluminum busbar system with 25kA fault withstand capacity, supported on SMC supports and insulated with heat-shrinkable sleeves, internal wiring using FRLS copper conductors, appropriate interlocking between feeders, double earthing using 25x3 mm Cu strips, and mounting on MS channel base. All components shall be IS/IEC certified, and the panel shall be tested at CPRI for short circuit, temperature rise, and IP protection as per IS 8623/IEC 61439 standards. |
| 286 | Common Panel:- SITC of Common Panel shall be a factory-fabricated, floor- mounted, indoor type, compartmentalized, dust and vermin proof, CPRI approved panel with IP54 protection, fabricated from CRCA sheet steel with epoxy powder coating. The panel shall have an incomer consisting of 1 No. 63A 4P MCCB (25kA, thermal magnetic) and 1 Set of RYB LED indication lamps with 2A fuses. The outgoing section shall comprise 3 Nos. 40A 4P MCBs, 3 Nos. 25A SP MCBs, each with ON/OFF/TRIP LED indicators with protective 2A fuses. The panel shall include a 63A rated, 4P extensible aluminum busbar system with 25kA fault withstand capacity, using high conductivity aluminum, supported on SMC supports, and insulated with color-coded heat shrinkable sleeves. Proper internal wiring using FRLS copper cables shall be provided along with necessary mechanical/electrical interlocking arrangements. The panel shall include double earthing with 25x3 mm GI earth strips and shall be mounted on an MS channel base frame . All devices shall conform to IS/IEC standards, and the panel shall be built and tested in compliance with IS 8623/IEC 61439. Final construction shall follow the approved Single Line Diagram (SLD). |
| 287 | Lift Panel:- Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory Incomer:- a) 63 A 4P Isolator b)1 Set RYB Indication Lamp Outgoings:- a) 40 A 4P MCB - 2 Nos b) 25 A SP MCB - 4 No . ON-OFFTRIP Lamps with 2A fuse . 63 A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.Details to be as shown in SLD. |
| 288 | Supply, Installation, Testing and Commissioning (SITC) of AC Panel shall be factory fabricated, floor mounted, indoor type, compartmentalized, dust and vermin proof, CPRI approved panel board having IP54 degree of protection, fabricated out of 2.0 mm thick CRCA sheet steel (1.6 mm for partitions/doors) with suitable stiffeners, duly pre-treated with 7 tank process and finished with epoxy polyester powder coating of approved shade.The panel shall comprise 160A, 16kA, 4 Pole MCCB (Thermal Magnetic Release) as incomer with adjustable overload and short circuit protection, complete with rotary operating handle and door interlock arrangement. The incomer section shall be provided with:1 Set of RYB LED phase indicating lamps with individual 2A control fuses1 Set of digital/analog ammeters (96x96 mm) with selector switch to monitor current in all three phasesSuitable rating current transformers (CTs) of accuracy class 1.0 for metering purpose The outgoing section shall consist of the following MCCBs:1 No. 100A, 4P MCCB (16kA, thermal magnetic release) 4 Nos. 63A, 4P MCCBs (16kA, thermal magnetic release)All MCCBs shall be complete with ON/OFF/TRIP mechanical indication, necessary auxiliary contacts, shunt trip/undervoltage release (if required), and proper interconnections as per approved Single Line Diagram.The panel shall be provided with suitably rated 4P extensible aluminium busbar system, minimum 160A rated, with fault withstand capacity of 16kA for 1 second, made of high conductivity aluminium, supported on SMC/DMC insulated supports, and insulated with colour coded heat shrinkable sleeves. Neutral busbar shall be 100% rated and earth busbar of adequate size shall run throughout the length of the panel.Internal wiring shall be carried out using FRLS copper control cables with proper ferruling, identification sleeves, and neatly dressed with cable ties and PVC channels. Adequate space shall be provided for cable termination with removable gland plates at bottom, complete with brass cable glands and tinned copper lugs.The panel shall have double earthing provision with 25x3 mm GI earth strips on both sides, complete with earthing terminals. The panel shall be mounted on suitable MS channel base frame grouted to the floor.All components shall conform to relevant IS/IEC standards. The panel shall be designed, assembled and routine tested as per IS 8623 / IEC 61439. Final fabrication shall be strictly as per approved Single Line Diagram (SLD) and site requirements, complete in all respects. |
| 289 | Lights and Fans |
| 290 | 12W LED Surface Mounted Downlight . SITC of 12W surface mounted LED downlight, housing made of powder-coated die-cast aluminium/polycarbonate body in white finish, operating on 220?240V AC, 50Hz with integrated LED module, CCT 6000K (cool daylight), CRI ?80, power factor ?0.90, luminous efficacy ?90 lm/W (minimum 1080 lumens), beam angle 100°?120°, with inbuilt constant current electronic driver having surge and short-circuit protection, ingress protection minimum IP20, operating temperature ?10°C to +45°C, complete with all accessories as required, conforming to IS/IEC standards and with minimum 2 years warranty. (model wipro -LD06 -151XXX- 57SMG1 or equivalent in the approved list of makes) |
| 291 | 24W LED Surface Mounted Downlight - SITC of 24W surface mounted LED downlight, housing made of powder-coated die-cast aluminium/polycarbonate body in white finish, operating on 220 ?240V AC, 50Hz with integrated LED module, CCT 6000K (cool daylight), CRI ?80, power factor ?0.90, luminous efficacy ?90 lm/W (minimum 2160 lumens), beam angle 100°-120°, with inbuilt constant current electronic driver having surge and short-circuit protection, ingress protection minimum IP20, operating temperature -10°C to +45°C, complete with all accessories as required, conforming to IS/IEC standards and with minimum 2 years warranty.( model wipro LD06-301XXX-57SMG1 or equivalent in the approved list of makes) |
| 292 | 36W 2x2 LED Surface Mounted Panel Light - SITC of 36W surface mounted LED panel light of size 2x2, housing made of powder-coated die-cast aluminium/extruded aluminium with white finish, operating on 220-240V AC, 50Hz with integrated high- efficiency LED module, CCT 5700K (cool daylight), CRI ?80, power factor ?0.90, luminous efficacy ?100 lm/W (minimum 3600 lumens), wide beam distribution, with inbuilt constant current electronic driver having surge and short-circuit protection, ingress protection minimum IP20, operating temperature -10°C to +45°C, complete with all accessories as required, conforming to IS/IEC standards and with minimum 2 years warranty. (model wipro CRCO10S036HP57G4 or equivalent in the approved list of makes) |
| 293 | 20W 4FT LED Batten Light- SITC of 20W, 4 feet long LED batten light(Retrofit Tube Light Fitting) with housing made of extruded aluminium/polycarbonate in white finish, operating on 220-240V AC, 50Hz with integrated LED module, CCT 5700K (cool daylight), CRI ?80, power factor ?0.90, luminous efficacy ?100 lm/W (minimum 2000 lumens), wide beam angle, with inbuilt constant current electronic driver having surge and short-circuit protection, ingress protection minimum IP20, operating temperature -10°C to +45°C, complete with all accessories as required, conforming to IS/IEC standards and with minimum 2 years warranty. (model- wipro-LL31-251-XXX-57AL5 or equivalent in the approved list of makes) |
| 294 | Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 295 | Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light complete with electronic driver including all required mounting accessories, frames, complete |
| 296 | Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air |
| 297 | Projector System |
| 298 | Supply, Installation, Testing and Commissioning of Motorized Projector Screen of size 100 inch including mounting accessories and mounting the same on ceiling/wall as required by Site Engineer-in-charge. |
| 299 | Supply, Installation, Testing and Commissioning of Full HD DLP Multimedia Projector having Resolution Full HD (1920x1080 pixels), Brightness upto 3400 lumens, Contrast Ratio upto 16000:1, Lamp Life Minimum 10000 Hrs, Connectivity – HDMi, VGA, USB, Audio Ports, mounting kit and mounting the same on ceiling/wall as required by Site Engineer-in-charge, supply and providing HDMi cable of length 15m and integrating the same to the PC/Laptop provided at site.Make: BenQ TH575/ Epson EH-TW750 |
| 300 | Telephone/TV |
| 301 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 302 | Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.Telephone socket outlet |
| 303 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 304 | Supply, installation, testing, and commissioning of Telephone Krone Type Disconnection Box with 10-pair or 20-pair capacity (expandable), suitable for structured voice cabling distribution. The box shall include high-quality LSA-PLUS (Krone type) modules, a weather-resistant enclosure, and accessories. |
| 305 | Supply, laying and termination of 10 pair telephone cable, 0.5mm copper PVC insulated, unarmoured telephone cable drawn in the existing cable tray |
| 306 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 307 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 308 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 309 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 310 | Network and CCTV System |
| 311 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 312 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 313 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 314 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 315 | Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts nuts, etc. as required.300mm width X 50mm depth X 1.6mm thickness |
| 316 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 317 | Supplying and fixing RJ45 Outlet including cover plate, Keystone Jack and Gang box supporting, connection etc. as required |
| 318 | Supply, installation, testing, and commissioning of 24-Port, 1U, Cat6A fully loaded shielded patch panel, suitable for high-speed structured cabling systems in data and networks. Make - Molex / Legrand / D-Link/ equivalent |
| 319 | Supply, installation, testing, and commissioning of 8-Port, 1U, Cat6A fully loaded shielded patch panel, suitable for high-speed structured cabling systems in data and networks. Make - Molex / Legrand / D-Link/ equivalent |
| 320 | Supply, installation, testing commissioning of 24 port L2 Ethernet switch |
| 321 | Supply, installation, testing commissioning of 8 port L2 Ethernet switch |
| 322 | Supply, installation, testing and commissioning of 10 100/1000 SFP ports + 4 Combo 10/100/1000 Copper ports + 4 10G SFP+ ports, - Core Switch |
| 323 | Supply and installation of Cat 6 UTP patch cord, 1 mtr |
| 324 | Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete |
| 325 | Supply and fixing of 9U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete |
| 326 | Supply, installation, testing and commissioning of IP based IR Varifocal dome Camera, 1/3" CMOS, 4 MP, night vision compatible, IR range of 30 mtrs PoE, inbuilt micro SD card slot, Ethernet port, H.264, IP 66, ONVIF, UL, FCC CE certified. All mounting accessories shall be included |
| 327 | Supply,installation, testing and commissioning of IP Network Video Recorders 32 channel with 32 ports, 2 SATA, audio 1 input 1 output, video 1 HDMI 1 VGA, recording resolution 5MP/3MP/1080P, 720P/ D1 @ 30 fps, network throughput 200 Mbps from IPC and 128 Mbps to Client, Smart search supported, Remote access by DDNS P2P, 4 channel alarm input and 2 channel relay output, 2 USB ports, ONVIF, UL CE certified. |
| 328 | Supply, installation, testing and commissioning of 24 10/100/1000BASE-T ports + 2 10GBASE-T ports + 4 10G SFP+ ports, L3 Stackable Managed Switch - Core Switch |
| 329 | Supply, installation, testing and commissioning of 8-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbp Managed Switch, 60 Watts, 8 port- Edge PoE switch |
| 330 | Supply, installation, testing and commissioning of Server PC, Intel i7 processor, 24 inch LED monitor, Gigabit LAN port, USB port, 8GB DDR3 RAM,1TB HDD,1GB dual graphic card, 100/1000 LAN ports, optical mouse, Keyboard, DVD Writer.Genuine Win 8.1 Pro - Down grade to Win 7 professional, 24 inch LED monitor |
| 331 | Supply, installation, testing and commissioning of Surveillance / ESATA compatible Hard Disk of 10TB capacity to achieve the total storage for the NVR server. |
| 332 | Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. |
| 333 | Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent |
| 334 | HVAC System |
| 335 | VRF AIR CONDITIONING OUTDOOR UNITSupply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.Modular type Outdoor Units equipped with Multiple Standard efficiency Scroll Compressor with Inverter Compressor including ODU Connection kit for multiple ODUs 20 HP Capacity (TOP DISCHARGE TYPE VRF ODU) |
| 336 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.Modular type Outdoor Units equipped with Multiple Standard efficiency Scroll Compressor with Inverter Compressor including ODU Connection kit for multiple ODUs 30 HP Capacity (TOP DISCHARGE TYPE VRF ODU) |
| 337 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.Modular type Outdoor Units equipped with Multiple Standard efficiency Scroll Compressor with Inverter Compressor including ODU Connection kit for multiple ODUs 42 HP Capacity (TOP DISCHARGE TYPE VRF ODU) |
| 338 | Master Controller capable of standalone operation to monitor control the operation of all the ODUs and IDUs listed above from within the office including control wiring complete as required for a fully functional system |
| 339 | Supply, installation, testing and commissioning of following minimum capacity and VRF/VRV Cassette type Indoor unit equipped with washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordedless remote control, suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.4 way Cacssette units 1.0 TR |
| 340 | Supply, installation, testing and commissioning of following minimum capacity and VRF/VRV Cassette type Indoor unit equipped with washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordedless remote control, suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.1.6 TR 4 way cacssette units |
| 341 | Supply, installation, testing and commissioning of following minimum capacity and VRF/VRV Cassette type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordedless remote control, suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.2 TR 4 way cacssette units |
| 342 | Supply, installation, testing and commissioning of following minimum capacity and VRF/VRV Cassette type Indoor unit equipped with washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordedless remote control, suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.2.6 TR 4 way cacssette units |
| 343 | Supply, installation, testing and commissioning of following minimum capacity and VRF/VRV Cassette type Indoor unit equipped with washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordedless remote control, suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.3.2 TR 4 way cacssette units |
| 344 | Supply, installation, testing and commissioning of following minimum capacity and VRF/VRV Cassette type Indoor unit equipped with washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordedless remote control, suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.4 TR 4 way cacssette units |
| 345 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required |
| 346 | Supply and Installation of REFNET JOINT Kits as per manufacturers recommended standards (For all sizes) |
| 347 | Supply and Installation of PVC Insulated flexible control cable with saddles / supportes and PVC conduits to connect outdoor unit with Indoor unit (as per manaufacturar's standard) |
| 348 | Additional gas charging |
| 349 | Supply of all materials and Installation of drain pipe between Indoor unit and drain point including U Trap. (slope of pipe is 1:100)Drain pipe for condensate drain to the nearest drain point with 25mm uPVC pipe insulated using 9mm thick Nitrile Rubber tubing as per Client/Engineers instruction. |
| 350 | Supply & Installation of Circular Inline Exhaust FanSupplying, installing, testing and commissioning of Circular Inline Exhaust Fan of capacity 850 CFM (minimum), suitable for 230/415 V, 50 Hz AC supply, complete with dynamically balanced aluminium/steel impeller directly coupled to single phase/suitable motor with IP-44 or higher protection, class B insulation, mounted in heavy duty powder coated / galvanized steel housing, suitable for duct mounting, including necessary mounting brackets, anti-vibration pads, canvas connection where required, connection to existing duct with necessary clamps, nuts, bolts and rubber gasket, complete with internal wiring up to terminal box, earthing provision, and testing for satisfactory operation, complete as required and as directed by the Engineer-in-Charge. make ostberg or as per Approval of Engineer in charge |
| 351 | Supplying, installing, testing and commissioning of Circular Inline Exhaust Fan of capacity 290 CFM (minimum), suitable for 230/415 V, 50 Hz AC supply, complete with dynamically balanced aluminium/steel impeller directly coupled to single phase/suitable motor with IP-44 or higher protection, class B insulation, mounted in heavy duty powder coated / galvanized steel housing, suitable for duct mounting, including necessary mounting brackets, anti-vibration pads, canvas connection where required, connection to existing duct with necessary clamps, nuts, bolts and rubber gasket, complete with internal wiring up to terminal box, earthing provision, and testing for satisfactory operation, complete as required and as directed by the Engineer-in-Charge. |
| 352 | Supply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such a s tee, bends, special off shoots, inspection doors, transformation pieces etc. a s required a s per IS 655 including suspension and supporting arrangement for plenum, duct etc. as required.0.63 mm (24 Gauge) |
| 353 | Providing and fixing canvas connection at inlet and outlet of fan or between duct sections to isolate vibration and prevent transmission of noise, made of heavy duty fire-retardant, double layered canvas / flexible PVC coated fabric of suitable width (minimum 150 mm), air-tight and properly stitched, sandwiched between G.I. sheet flanges on both sides, duly bolted with nuts, bolts, washers and provided with rubber gasket for air-tight joint, complete with necessary supports, clamping arrangement and sealing, suitable for operating pressure and temperature of the system, complete as required and as directed by the Engineer-in-Charge. |
| 354 | Providing and fixing powder coated aluminium grilles / diffusers of approved make, of required size and type (supply air / return air), fabricated out of extruded aluminium sections with fixed/adjustable horizontal and/or vertical louvers, having powder coated finish of approved shade, complete with opposed blade damper (for supply air diffusers where specified), concealed fixing arrangement, gasket, screws, rawl plugs, frame and all necessary accessories, suitable for mounting on wall/ceiling/false ceiling or duct as required, complete with cutting and making good the openings in walls/ceilings, testing and commissioning for proper air distribution, complete as required and as directed by the Engineer-in-Charge. |
| 355 | Providing and fixing exhaust air louver of required size, fabricated out of extruded aluminium sections with fixed inclined blades designed to prevent entry of rainwater, powder coated in approved shade, complete with factory fitted bird/insect screen made of G.I. wire mesh of suitable gauge, rigid frame with concealed fixing arrangement, gasket, screws, rawl plugs and all necessary accessories, suitable for installation in wall opening/duct termination as required, including cutting and making good the wall/finishing, complete as required and as directed by the Engineer- in-Charge. |
| 356 | Documentation |
| 357 | Providing services for enhancement of connected load including preparation of detailed load statement, single line diagram and necessary drawings, submission of application to KSEB and Electrical Inspectorate, obtaining scheme approval, coordination for site inspection, compliance of observations if any, and obtaining final sanction/approval for load addition, complete as required; statutory fees such as KSEB documentation charges, supervision charges and Electrical Inspectorate fees shall be reimbursed separately on submission of original receipts. |
| 358 | Fire Extinguishers |
| 359 | Supply installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent(UL Listed) |
| 360 | Supply installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent |
| 361 | Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity - 5 kg Make : SAFEX/MINIMAX/CEASEFIRE or equivalent |
| 362 | First Aid Hose Reel System Down Comer System |
| 363 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 364 | Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 365 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure of the outlet to the level of 3.5kg/cm2 complete as required. |
| 366 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 367 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 368 | Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304) |
| 369 | Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304) |
| 370 | Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 9890, at required locations. 25 mm dia Make : Kartar/Atom |
| 371 | Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock key (UL Listed). |
| 372 | Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S.Pipe |
| 373 | supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required. |
| 374 | Terrace pump related |
| 375 | (a) Supplying, installation, testing and commissioning of electric driven900 lpm at 35m Head |
| 376 | Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including: - IP54-rated enclosure with powder-coated CRCA sheet steel. - 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation. - Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.). - Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches). - Copper wiring, termination, and provision for cable glands. - Installation, onsite calibration, and full functional testing for pressure-based automation. |
| 377 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 378 | Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 9890, at required locations. 20 mm dia Make : Kartar/Atom |
| 379 | Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. |
| 380 | Providing and fixing of pressure switch in MS pipeline including connection etc as required. |
| 381 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle ,bronze or gun Metal seat, ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required:100 mm dia |
| 382 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 383 | Piping system |
| 384 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 385 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia |
| 386 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia |
| 387 | MOEFA with PA Talk back system |
| 388 | INTELLIGENT FIRE ALARM SYSTEMTwo Loop Panel |
| 389 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 390 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 391 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sq mm |
| 392 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 393 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 394 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 395 | Supply, Installation, Testing and Commissioning of Addressable talk back speaker with call switch. Speaker shall have built-in microphone, full-duplex communication capability and and be compatible with fire alarm and emergency PA systems. Wall mounted type/flush type. |
| 396 | Supply, installation, testing, and commissioning of an addressable PA cum Talkback Control Panel with a minimum of 6 zones, compliant with NFPA standards. The system shall include an integrated paging unit, an inbuilt digital amplifier (250W RMS or higher, expandable), and talkback functionality for two-way communication. It shall support direct integration with Fire Alarm Control Panels (FACP) for emergency voice evacuation, provide automatic priority paging in emergency mode, and include pre-recorded message storage (minimum 8 hours, expandable). The panel shall feature AC mains (230V, 50Hz) operation with inbuilt 24V DC battery backup, ensuring 24-hour standby and 30-minute full-load operation. The system shall have built-in diagnostics, fault monitoring, and remote operation capabilities, housed in a rack-mounted/wall-mounted enclosure with forced ventilation.Make/Model: ASES / Ravel / Agni or equivalent. |
| 397 | CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 398 | Supplying, installation, testing commissioning of wall mounted speaker, 10Watt, 85-90dB SPL in 1m, built in ABC enclosure complete as required |
| 399 | Supplying, installation, testing commissioning of ceiling mounted speaker, 6 Watt, built in ABC enclosure complete as required |
| 400 | Supplying, Installation, testing commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. |
| 401 | Signages |
| 402 | Supply, Installation, Testing Commissioning of photo-luminescent signages made of rigid self-illuminating material as per IS 15327:2003 and NBC 2016 guidelines. The signage shall be of minimum size 300mm x 100mm (for directional signs) or 450mm x 150mm (for exit signs) with high-contrast text ensuring visibility for at least 90 minutes after power failure. The text shall include messages such as EXIT, EMERGENCY EXIT, FIRE EXIT, FIRE EXTINGUISHER, ASSEMBLY POINT, STAIRCASE, DO NOT USE LIFT IN CASE OF FIRE, FIRE STATION, FIRE PUMP ROOM, FIRE COMMAND CENTER etc., as per site requirements. The signage shall be fixed using screws nylon plugs (for walls), adhesive (for smooth surfaces), or MS chain suspension (for ceiling mounting). Testing shall be conducted as per IS standards to ensure compliance with fire safety norms. |
| 403 | Supply and Fixing of Assembly Point Signage made of retro-reflective, weatherproof, fire-retardant aluminum composite panel (ACP) conforming to releavant standards. The signage shall be of suitable size with a green background and white text, incorporating the standard assembly point symbol. The signage shall be mounted on a MS/GI pole of 50mm diameter, minimum 2.4m (8 feet) height, with a galvanized finish and epoxy paint for corrosion resistance. The pole shall be firmly fixed in a concrete foundation to withstand outdoor conditions. |
| 404 | Supply and Fixing of Floor Evacuation Plan printed on high-quality acrylic sheet with a minimum thickness of 3mm, complying with releavant standards. The evacuation plan shall be of suitable size, with clear, color-coded floor layout, escape routes, emergency exits, firefighting equipment locations (fire extinguishers, hydrants, alarms), and assembly points as per approved fire safety guidelines. The plan shall have photo-luminescent/glow-in-the-dark features for visibility in low-light conditions. Fixing shall be done at eye level (1.5m from the floor) using stainless steel screws with nylon plugs or industrial-grade adhesive for firm mounting on walls. |
| 405 | Supply and Fixing of Fire Order Signage printed on high-quality acrylic sheet with a minimum thickness of 3mm, complying with releavant standards. The signage shall be of suitable size, with a clear, legible format displaying step-by-step fire emergency procedures, evacuation instructions, fire safety dos and don?ts, and emergency contact numbers. The text and symbols shall be in bilingual format (English and local language) with high-contrast colors and photo-luminescent/glow-in-the-dark features for visibility in low-light conditions. Fixing shall be done at eye level (1.5m from the floor) using stainless steel screws with nylon plugs or industrial-grade adhesive for firm mounting on walls. |
| 406 | General Electrical works |
| 407 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 408 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 409 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm |
| 410 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail