| 1 | CIVIL WORK |
| 2 | Scraping of Cement Plaster complete in all respect as per PWD specifications |
| 3 | Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means) (8.39) |
| 4 | Dismantling concrete or precast concrete. (e) Reinforced Cement concrete |
| 5 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.CSR 6.6 |
| 6 | Cement concrete 1:8:16 with stone ballast 40mm gauge mixing by manual means CSR 10.6 b(i) |
| 7 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) CSR 9.1 |
| 8 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 9 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth CSR 11.5 |
| 10 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. CSR 11.6 |
| 11 | Extra for work done in additional storey upto 4 metre above the top of structural roof of ower storey for Brick Work/ Concrete Block/ Clay Block. |
| 12 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 13 | Earth Filling: Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 3003 of MORT&H specifications |
| 14 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.CSR 9.8 |
| 15 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) CSR 9.4 |
| 16 | Extra for smooth surface |
| 17 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.CSR 10.21 |
| 18 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete CSR 18.18 |
| 19 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm CSR 14.115(a) |
| 20 | Precast chequred tiles of 20mm minimum thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base for floors, treads of steps and landings |
| 21 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical Mixture for mixing of material CSR 14.3 |
| 22 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material. (as per AC slip No.1) |
| 23 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. (correction as per AC slip-2 ) (b) Size 800x800 mm |
| 24 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.(Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.) CSR 18.51 (a) |
| 25 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. (Door and window frame of size 113mmx60mmx with 35mm wide single rebate) CSR 18.51 (b) |
| 26 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2202-1) 1999 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 27 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area up to 0.50 sqm |
| 28 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect (b) Glazing area above 0.09 sqm (ii) 4mm thick or 10.78 Kg/ sqm |
| 29 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flashwelded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) |
| 30 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing CSR 13.13 (i) as per AC slip No.9 |
| 31 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 32 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 CSR 13.51 |
| 33 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.CSR 13.55 |
| 34 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf /cm2) conforming to IS: 4985, including fixing with MS clamps (i) U-PVC pipes (working pressure 4 kgf./sqcm pipe 110mm dia. CSR 13.74 (a) (i) |
| 35 | Providing and fixing 110 mm dia SWR U.P.V.C Bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-incharge. UPVC 110 mm bend |
| 36 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- chargeUPVC 110 mm Coupling /Sockets |
| 37 | 12.5mm thick cement plaster 1:5. |
| 38 | 20mm thick cement plaster 1:4 in two coat work. CSR 15.20 |
| 39 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish CSR 16.65 |
| 40 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade CSR 16.10 |
| 41 | Providing surface treatment to external / internal wall with water resistant grade, anti fungal, anti rusting, antifoaming, high percentage acrylic binder washable surface with two coats to be provided with spatula over one coat cement primer including preparation of surface with water resistant grade match colour complete as per specifications and to the entire satisfaction of engineer- in- charge. CSR 16.68 |
| 42 | Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required |
| 43 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete |
| 44 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. CSR 16.16 |
| 45 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. CSR 16.18 |
| 46 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc.complete : |
| 47 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. II (size of door 701mm to 850mm) |
| 48 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 49 | Providing and fixing fixed beeding 12mm x 12mm for fixed galss |
| 50 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 51 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 52 | Credit of bricks |
| 53 | Credit of Steel |
| 54 | PH SERVICES |
| 55 | Providing & Installing 1 No. 160 mm o/d PVC straight TUBEWELL by drilling 200mm dia wtih Hand Boring up to depth of 110 m BGL, in all kinds of soil including the cost of consumable stores, fuel oil and transportation of drilling machine to the site of the proposed bore, complete in all respect |
| 56 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tubewellis lowered & tested, equipment as required such as hand boring machine and its accessory,transportationto site and vice versa etc. complete in all respect. |
| 57 | (b) Boring with 200mm id Housing Pipe |
| 58 | 0 to 150 m |
| 59 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in charge |
| 60 | (b) 150 mm nominal size dia. |
| 61 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 62 | (b) 150 mm nominal size dia. |
| 63 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 64 | Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 65 | Supplying & fixing of end capcomplete in all respects. |
| 66 | Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect |
| 67 | (b) 150 mm internal diameter |
| 68 | Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 69 | (a) Capacity of Air compressor 300 cfm at 250 PSI |
| 70 | Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 71 | Supplying & fixing of M.S. Clamp of size 200mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 72 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 73 | Providing for santary clay seal (as per BIS code IS 2500-2019) including sterlization of T/W |
| 74 | Providing, fixing, testing & commissioning (2 BHP) Submersible machinery with pump, Cable, Column pipe & Starter .etc, reputed make complete in all respects. |
| 75 | providing laying , jointing fixing and testing ISI marked PVC pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. |
| 76 | 20mm i/d |
| 77 | 25mm i/d |
| 78 | 32mm i/d |
| 79 | 40mm i/d |
| 80 | Providing fixing and jointing ISI marked gun-metal peet valves (heavey pattren ) as pewr IS 778 with hand wheels, on G.I. pipe lines laid in the ground of inside building including all carriages complete. |
| 81 | 20mm i/d gun metal peet valve heavy pattren. |
| 82 | 25mm i/d gun metal peet valve heavy pattren. |
| 83 | 32mm i/d gun metal peet valve heavy pattren. |
| 84 | 40mm i/d gun metal peet valve heavy pattren. |
| 85 | Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. |
| 86 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) infoundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 87 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 88 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS-13592 including cutting, jointing, wastage, but excluding cost of lead jointing. |
| 89 | 110mm i/d SWR UPVC pipe lines laid complete |
| 90 | 70mm i/d SWR UPVC pipe lines laid complete |
| 91 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 92 | Providing and fixing jet spray with 2'-6\\" longPVC pipe. |
| 93 | With C.P. Brass nut |
| 94 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. |
| 95 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 96 | Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling |
| 97 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 98 | C.P. brass Bib cock without flange |
| 99 | Providing & fixing in position C.I gully trap cover weighing approximately 7.26 kg and frame for gully trap camber clear opening size 300mm x 300mm and outside size 330mmx330mm including painting the exposed surface with 3 coats of black bit mastic superior paint of approved make (to the approval of Engineer-in charge). |
| 100 | Providing & Fixing H.C.I. floor traps conforming to ISI specification (IS:1729) of approved make (to the approval of Engineer-In-Charge) of the self cleaning design with CP brass hinged grating with fram eith or without vent arm and including cement concrete 1:2:4 under and around the floor level complete in all respects including cutting and making good the walls and floors etc. minimum depth of water should be 150mm with a minimum seal 50mm. |
| 101 | (b) with 75mm i/d outlet deep seal. |
| 102 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 103 | Providing & fixing in position on terrace (at allfloor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer -in-charge) complete in all respect. |
| 104 | For 1000 ltr capacity tank and above |
| 105 | Electrical Works |
| 106 | RECESSED PVC CONDUIT PIPE WIRING SYSTEMWITH MODULAR SWITCHES: |
| 107 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:- |
| 108 | Wiring fan point (With fan box) |
| 109 | Wiring light point |
| 110 | Wiring 6Amp. wall socket point |
| 111 | Wiring 6Amp. Plug control comprising wall socket point |
| 112 | Wiring 16/20Amp. power plug control point |
| 113 | RECESSED AIR CONDITION SUPPLY TERMINAL POINTS: |
| 114 | Wiring air condition supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- |
| 115 | Wiring AC supply terminal points having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 116 | RECESSED COMPUTER SUPPLY TERMINAL POINTS: |
| 117 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- Accessories |
| 118 | Wiring Computer terminal points having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator and 2No. blanking plate (Modular accessories). |
| 119 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 120 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 121 | Overall size 1.5sq.mm (Un-sheathed) |
| 122 | Overall size 2.5sq.mm (Un-sheathed) |
| 123 | Overall size 4sq.mm (Un-sheathed) |
| 124 | Overall size 6sq.mm (Un-sheathed) |
| 125 | Overall size 10sq.mm (Un-sheathed) |
| 126 | COPPER EARTHING: |
| 127 | 8 SWG COPPER EARTHING : |
| 128 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A- Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length).G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:- |
| 129 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 130 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 131 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs. |
| 132 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 133 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 134 | SHEET METAL DOUBLE DOOR DISTRIBUTIONBOARD FOR MCB/ RCBO/ RCCB's: |
| 135 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: |
| 136 | SP&N Double Door Distribution Board 12 way each |
| 137 | XLPE INSULATED UN-ARMOURED CABLES (ONSURFACE): |
| 138 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 139 | Overall size 16sq.mm (2Core) Un-armoured (On- Surface) |
| 140 | SHEET METAL BUS BAR CHAMBERS (COPPERSTRIPS): |
| 141 | Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross- sectional area mounted on DMC/ SMC moulds at sufficient distance enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- |
| 142 | Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal |
| 143 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Beside this the lighting fixture manufactor should have hour NABL |
| 144 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Beside this lighting fixture manufactor should have hour NABL |
| 145 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in- charge at site. |
| 146 | SITC of Wall Fan Size 400MM complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 147 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in charges at site. |
| 148 | Providing Flood Lighting |
| 149 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 150 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 151 | Overall size 1sq.mm (Un-sheathed) |
| 152 | Overall size 1.5sq.mm (Un-sheathed) |
| 153 | XLPE INSULATED UN-ARMOURED CABLES (ONSURFACE): |
| 154 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 155 | Overall size 10sq.mm (3Core) Un-armoured (On- Surface) |
| 156 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 157 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs. |
| 158 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 159 | Supply and erection of SMC FRP (Glass Fibre reinforced polyester sheet moulding compound conforming to IS:13410) Junction Box (Recessed/ On surface) conform to IS:14772, robust constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site. |
| 160 | SMC FRP (Glass Fibre reinforced polyester sheet moulding compound confirming to IS:13410) Junction Box conform to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 161 | SHEET METAL IRON CLAD SWITCHES: |
| 162 | Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- |
| 163 | ICDP Switch 32amp., 415volts |
| 164 | Supply and erection of LED Flood Light 50 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty Including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. Please Enable Macros to View BoQ information |