| 1 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 2 | Group B. |
| 3 | DSR Item No. 1.16Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 4 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 5 | 3 x 1.5 sq. mm |
| 6 | 3 x 2.5 sq. mm |
| 7 | 3 x 4 sq. mm |
| 8 | 6 x 6 sq. mm |
| 9 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | DSR item No.1.23Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 11 | 5/6 amps switch |
| 12 | 2 way 5/6 A switch |
| 13 | 3 Pin 5/6 A. socket outlet |
| 14 | Bell push |
| 15 | DSR Item No. 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. |
| 16 | DSR Item No. 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 17 | DSR Item No. 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 18 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 19 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 20 | 4 way (4 + 12) Double door |
| 21 | DSR Item No. 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 22 | 8 way (4 + 24), Double door |
| 23 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Triple pole and neutral |
| 26 | Triple pole |
| 27 | Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc as required. |
| 28 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 15 of the DNIT). |
| 29 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 30 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, (As per Complete Item No. 15 of the DNIT). |
| 31 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 32 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. (As per Complete Item No. 15 of the DNIT). |
| 33 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The make should be Super Hylam / Formica / GreenLam only. |
| 34 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 15 of the DNIT). |
| 35 | DSR Item No. 2.2.13Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 36 | 100 A,30KA,FPMCCB |
| 37 | DSR Item No. 1.57Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required |
| 38 | DSR Item No. 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Please Enable Macros to View BoQ information 35.0 Each 687.0 24045.0 2.0 Each 1064.0 2128.0 0.0 150.0 PM 104.0 15600.0 120.0 PM 148.0 17760.0 30.0 PM 222.0 6660.0 0.0 20.0 PM 151.0 3020.0 20.0 PM 168.0 3360.0 0.0 43.0 Each 63.0 2709.0 10.0 Each 81.0 810.0 2.0 Each 112.0 224.0 0.0 2.0 Each 2871.0 5742.0 0.0 16.0 Each 285.0 4560.0 2.0 Each 696.0 1392.0 2.0 Each 296.0 592.0 28.0 Each 55.0 1540.0 1500.0 Per Sq. Inch 1.5 2250.0 0.0 4.0 Each 2695.0 10780.0 0.0 2.0 Each 4930.0 9860.0 2.0 Each 1140.0 2280.0 2.0 Each 1806.0 3612.0 118924.0 |