Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL PORTION WORK:-Earth work in excavation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge |
| 2 | Sand filling in foundation and plinth including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights). |
| 3 | i)Ground |
| 4 | ii)Compound Wall |
| 5 | Filling area with excavated earth materials including labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 6 | i)Ground |
| 7 | ii)Compound Wall |
| 8 | Conveyance of excavated earth materials by mechanical means including 5km lead complete including all labour, materials & royality etc. complete as per direction of EIC. |
| 9 | i)Ground |
| 10 | Providing & laying plain cement concrete (1:3:6) using 4cm size metal etc. complete including all labour, materials & royality etc. complete as per direction of EIC. |
| 11 | i)Ground |
| 12 | ii)Compound Wall |
| 13 | Providing single under reamed pile foundation with RCC M25 using 12mm size black c.b.h.g stone chips including cost of boreholes, M.S. rod / tor steel and labour charges for cutting, bending & binding of steel. AS per nbc including cost & conveyance of all material, labours, T&P , hire charges of all mechinaries, bentonite powder, all taxes, royaliity, labour cess etc all complete as per the direction of EIC. |
| 14 | i)Ground |
| 15 | Providing lifting, hoisting and laying R.C.C. of M-20 Grade to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge. |
| 16 | a)Base Footing |
| 17 | i)Ground |
| 18 | ii)Compound Wall |
| 19 | (b) Column in s/s |
| 20 | i)Ground |
| 21 | ii)First floor |
| 22 | iii)Head room |
| 23 | iv)Compound wall |
| 24 | (c) Plinth beam |
| 25 | i)Ground |
| 26 | ii)Compound Wall |
| 27 | (d) Lintel band |
| 28 | i)Ground |
| 29 | ii)First floor |
| 30 | iii)Head room |
| 31 | iv)Compound wall |
| 32 | (e) Chajja( at lintel level & window sill level ) |
| 33 | i)Ground |
| 34 | ii)First floor |
| 35 | iii)Head room |
| 36 | (g) Stair case |
| 37 | i)Ground |
| 38 | ii)First floor |
| 39 | (h) Roof Beam |
| 40 | i)Ground |
| 41 | ii)First floor |
| 42 | iii)Head room |
| 43 | (i) Roof slab |
| 44 | i)Ground |
| 45 | ii)First floor |
| 46 | iii)Head room |
| 47 | Supplying,Cutting,straightening of steel HYSD (Fe- 500) conforming to (IS- 1786) with bending, binding, cranking, hooking, welding or jointing if necessary & tying the grills and placing in position as required for the Rod work in all floors and & for providing fan hooks hosting lowering ,& laying steels including cost conveyance ,taxes & royalties of all materials and binding wires of 18 to 20 gauge & cost of all labour T&P required for the work etc. Complete in all respect as per the direction of Engineer in charges ( payment will be made on weight of MS rod or tor steel only basing on the co- efficient of MS rod or tor steel bars approved by SAIL/ TATA/ competent authority and (No separate payment will be made towards the cost of binding wires over lapping, wastage, coupling, welded, joints , spacer bars, ,chairs stays, hangers and annealed steel wires or other methods for binding and placing etc.) |
| 48 | i)Ground |
| 49 | ii)First floor |
| 50 | iii)Head room |
| 51 | iv)Compound wall |
| 52 | Fly ash brick masonary of size 25cmx12cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:6) in F&P including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge. |
| 53 | i)Ground |
| 54 | ii)Compound Wall |
| 55 | Brick work with fly ash bricks of size( 25cmx12cmx8cm) and crushing strength not less than 75 kg/cm2 in c,m(1:6) in Super structure including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge. |
| 56 | i)Ground |
| 57 | ii)First floor |
| 58 | iii)Head room |
| 59 | iv)Compound wall |
| 60 | Supplying of M.S. Grill made out of structural steel, flats, plates, bars confirming to IS for windows, ventilators etc. as per drawing and design, fixed to walls with clamps including priming 1 coat with all kdamages in walls and floors etc. including cost of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc.as per the direction of the Engineer in Charge. |
| 61 | i)Ground |
| 62 | ii)First floor |
| 63 | iii)Head room |
| 64 | Providing and fixing UPVC door frames factory made UPVC shutters made of styles and rails of a UPVC hollow section of size (60x50)mm and wall thickness 2.25mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corner by means of M.S. galvanized/plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The style of the shutter reinforced by inserting galvanised M.S. tube of size 20x20mm and 1mm wall thickness .The lock rail made up H section, a UPVC thickness fixed to the shutter stylesby means of plastics/galvanized M.S. U cleats. The shutter frame filled with a UPVC multi- chambered single pannel of size not less than 620mm, having over all thickness of 20mm and 1mm wall thickness.The panel filled vertically and tie bar at two places by inserting horizontally 6mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacture's specification and direction of Engineer -In -Charge. |
| 65 | i)Ground |
| 66 | ii)First floor |
| 67 | Supplying fitting and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA /NCL VEKA LTD.) Casement window with top fixed - 60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mm x2.5mm for outer frames , 75 mm x 60mm x 2.25 mm for casement window sash profile and 74 mm x 60 mm x 2.5 mm mullion profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like ciipping locking system made of aluminium 1 NO. per sashes and the system is to be installed at the site using anchor fasteners rubber sealant , easy glazing / deglazing at site etc. including cost and conveyance all materials , accessories , labour charges, materials and product conforming to D 638-14 , EN -477-95 and other applicable codes and standards. |
| 68 | i)Ground |
| 69 | ii)First floor |
| 70 | Supplying fitting and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA /NCL VEKA LTD.) Ventilator / Top Hung - 60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mm x2.5mm for outer frames , 75 mm x 60mm x 2.25 mm for casement window sash profile and 74 mm x 60 mm x 2.5 mm mullion profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like ciipping locking system made of aluminium 1 NO. per sashes and the system is to be installed at the site using anchor fasteners rubber sealant , easy glazing / deglazing at site etc. including cost and conveyance all materials , accessories , labour charges, materials and product conforming to D 638-14 , EN -477-95 and other applicable codes and standards. |
| 71 | i)Ground |
| 72 | ii)First floor |
| 73 | Providing 12mm thick cement plaster in cm (1:6) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 74 | i)Ground |
| 75 | ii)First floor |
| 76 | iii)Head room |
| 77 | iv)Compound wall |
| 78 | Providing 16mm thick cement plaster in cm (1:6) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 79 | i)Ground |
| 80 | ii)First floor |
| 81 | iii)Head room |
| 82 | iv)Compound wall |
| 83 | Providing 12mm thick cement plaster in cm (1:4) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 84 | i)Ground |
| 85 | ii)First floor |
| 86 | Supplying & fixing of industrial vitrified tiles on 20 mm thick bed of cement mortar 1:4 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing etc complete. |
| 87 | i)Ground |
| 88 | Supplying & fixing of vitrified tiles on 20 mm thick bed of cement mortar (1:4) jointed with neat cement slury mixed with pigment to match the shades of the tiles including all taxes etc complete. |
| 89 | i)Ground |
| 90 | ii)First floor |
| 91 | Supplying & fixing of vitrified tiles Dado on 12 mm thick bed of cement mortar (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles including all taxes etc complete. |
| 92 | i)Ground |
| 93 | ii)First floor |
| 94 | Supplying, fitting and fixing GraniteSlab (0.4 to 1.00 Sqm ) in floors of approved make laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.) |
| 95 | i)Ground |
| 96 | Supplying, fitting and fixing of Roller Blinds to windows as per approved design including cost, conveyance, taxes of all materials, labour, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 97 | i)Ground |
| 98 | ii)First floor |
| 99 | Supplying fitting fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balstrade of size 32mmx32mmx2mm @0.90mtr C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, pollishing etc with cost, conveyance taxex of all materials, labour, T&P etc. required for the complete in all respect. |
| 100 | i)Ground |
| 101 | ii)First floor |
| 102 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. |
| 103 | i)Ground |
| 104 | ii)First floor |
| 105 | iii)Head room |
| 106 | Providing plastic emulsion paint over a coat of including all cost of labour, materials, T&P and all taxes etc. complete as per direction of E.I.C. |
| 107 | i)Ground |
| 108 | ii)First floor |
| 109 | iii)Head room |
| 110 | Finishing wall surface with two coats of weather coat over a coat of cement priming including cost and conveyance of all materials, labour T&P, hire charges of machine, all taxes etc all completes in all respects as per the direction of Engineer charges. |
| 111 | i)Ground |
| 112 | ii)First floor |
| 113 | iii)Head room |
| 114 | iv)Compound wall |
| 115 | Painting two coats of synthetic enamel paint over including cost and conveyance of all materials, labour T&P, hire charges of machine, all taxes etc all completes in all respects as per the direction of Engineer charges. |
| 116 | i)Ground |
| 117 | ii)First floor |
| 118 | iii)Head room |
| 119 | Providing Antitermite treatments as per ISI specification including making holes 3'0\\" C/C both ways injecting chemical with water in propertion(1:20) or any approved propertion by the EIC & treatment to choukath sides & wall junction. Cost & conveyance of all materials, labours, T&P etc complete. as per direction of EIC. |
| 120 | i)Ground |
| 121 | 20 mm thick grading Concrete in (1:4) including cost of all charges etc complete. |
| 122 | i)Ground floor |
| 123 | ii)First floor |
| 124 | Providing 100 mm dia rain water down pipe including cost and conveyance of all materials, labour T&P, hire charges of machine, all taxes etc all completes in all respects as per the direction of Engineer charges. |
| 125 | i)Ground floor |
| 126 | ii)First floor |
| 127 | EI PORTION OF THE WORK:- Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI or equievalant reputed make A catagory ISI marked as approved with 20 mm dia PVC flexible non metallic conduit FRLS type ISI marked Make-AKG/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells of modular type G.I box with metallic cover plate (both side) (Flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. C |
| 128 | GROUP-A |
| 129 | GROUP-B |
| 130 | GROUP-C |
| 131 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 132 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 133 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 134 | Supplying,fixing of 2x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+2 no 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 135 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZH insulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, in recessed PVC conduit Heavy duty FRLS of mentioned size (AKG/Anchor/Kinjal or equievalant ISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 136 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 137 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 138 | 4 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non metallic heavy duty flexible conduit(LDB to LSB/5A SOCKET) (4X2.5+2X2.5) |
| 139 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOOR POINT/DG PANEL ESSENTIAL LOAD) (2X4+1X1.5) |
| 140 | 4 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty flexible conduit.(PDB to PSB/GAYSER. POINT/AC POINT/DG PANEL ACCL TO EACH QTR ESSENTIAL LOAD) (4X4+2X2.5) |
| 141 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5) |
| 142 | 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty flexible conduit .(LFDB TO FLOOR PANEL TO TPN BDB light ) (4X10+2X4) |
| 143 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens or equievalant reputed make & model A catagory ISI marked as approved,All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 144 | Supplying and fixing following size/ modules, GI box along with modular base & metallic cover plate (both side)plate for modular switches in recess etc as required as per direction of Engg.-in-Charge. MAKE-Legrand/Siemens/ Schneider or equievalant reputed make & model A catagory ISI marked as approved .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 145 | 4 moudle(125mmx75mm) |
| 146 | 1 moudle(75mmx75mm) |
| 147 | 12 moudle(200mmx150mm) |
| 148 | Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .MAKE KINJAL/ AKG/Anchor or equievalant reputed make A catagory ISI marked as approved |
| 149 | 20 MM |
| 150 | 25 MM |
| 151 | Supply and fixing modular type indicator on the existing switch box/cover . Equievalant higher model of Legrand/Schneider/Siemens make or equievalant reputed make & model A catagory ISI marked as approved as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 152 | Supplying and installation of AC starter Modular type, Equievalant higher model of Legrand/Schneider/Siemens make or equievalant reputed make & model A catagory ISI marked as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 153 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Equievalant higher model of Legrand/Schneider/Siemens/Panasonic make or equievalant reputed make & model A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 154 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 155 | Supplying,fixing of Blanking plate(modular type)( ( flame retradant type)) in existing switch box(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)complete suitable for IPH standard hospital.It should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 156 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make -Finolex/polycab or equievalant |
| 157 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep (Make-Equievalant higher model with 5 star rated of Havells/almonard/Anchor/Panasonic/Usha or equievalant reputed make & model A catagory ISI marked as approved ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 158 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan Make-Equievalant higher model with 5 star rated of Havells/almonard/Anchor/Panasonic/Usha or equievalant reputed make & model A catagory ISI marked as approved ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 2 years.. .(With fan Regulator) BLDC TYPE |
| 159 | Supplying and fixing of Energy efficient surface/recess mounted square shape 18 W LED luminaire of dimension of 225x 225 x 35 mm consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1500 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs warranty) and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. ( Make :Panasonic/Trilux/Osram/PHILIPS/Wipro/LT or equievalant reputed make & model A catagory ISI marked as approved).The luminaire should be Replacement Warranty will be 5 years |
| 160 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Similar to Panasonic / similar model of of LT /Wipro/PHILIPS/Havells or equievalant reputed make & model A catagory ISI marked as approved.). The luminaire should be Replacement Warranty will be 5 years . |
| 161 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.( Make :Panasonic/Trilux/Osram/PHILIPS/Wipro/LT or similar model of or equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years |
| 162 | Supply ,Installation testing commissioning of 45W, High efficient LED with aluminium housing in Pure Polyster UV resistant powder coated black finish and Top maintainable product with top opening die cast cover with acrylic clear glass reflector.CRI>70, IP66, Ambient temp-0 to 45DegC, Driver efficiency>85%, CCT-4000/5700K,THD<10%,Powerfactor>0.95, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 4275 lumens (110 lm/W). Similar to Panasonic / similar model of of LT /Wipro/PHILIPS/Havells. & model A catogory, ISI marked as approved, with proper model make having warrantied for a period of 2 years . The luminaire to be installed through moveable G.I braket as per the direction of Engg-in -charge. |
| 163 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 164 | SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K with 12 w/mtr @ 5Mtr pool with Driver extra as required as per direction of Engg.-in-Charge ( Make : Panasonic Model No:PSLM06604 with Driver Panasonic / similar model of of LT /Wipro/PHILIPS/Havells or equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years |
| 165 | Supplying and fixing of small focus light for small monuments as 30W , 5700 K required as per direction of Engg.-in-Charge Make : Panasonic / similar model of of LT /Wipro/PHILIPS/Havells or equievalant reputed make & model A catagory ISI marked as approved.)The luminaire should be Replacement Warranty will be 5 years |
| 166 | Supplying, Erection, Fixing, connection & testing of LED street light with braket Light of WIPRO /Havells/philips/Bajaj/Cromptron/Halonix or equvalant reputed make ISI marked as approved make with specification LED Luminarie 45 Watt with BRAKET MOVEABLE TYPE maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 167 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 168 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti -9/ Eaton or equievalant reputed make & model A catagory ISI marked as approved. as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 5 years |
| 169 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 2 years. |
| 170 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD ) |
| 171 | 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD) |
| 172 | Supplying and fixing 20 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /Eaton) or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years .MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5 years. |
| 173 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND/ Siemens-Betaguard/ Schneider- Acti 9/ or equievalant reputed make & model A catagory ISI marked as approved. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years.MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5 years. |
| 174 | Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA .Make-Equievalant higher model of Legrand/Siemens-Betaguard/ Schneider- Acti 9 or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC)AC ODU CONTROLLER). The RCCB should be Replacement Warranty will be 5 years |
| 175 | Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Make-Equievalant higher model of Legrand/Siemens-Betaguard/ Schneider- Acti 9 or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty will be 5 years |
| 176 | Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Make-Equievalant higher model of Legrand/Siemens-Betaguard/ Schneider- Acti 9s or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty will be 5 years |
| 177 | Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Make-Equievalant higher model of Legrand/Siemens-Betaguard/ Schneider- Acti 9 or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCB should be Replacement Warranty will be 5 years |
| 178 | Supplying and fixing 63Amps TPN 415 volts, MCB Make-Equievalant higher model of Legrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCB should be Replacement Warranty will be 5 years |
| 179 | Supplying and fixing 32/25Amps TPN 415 volts, MCB Make-Equievalant higher model of Legrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCB should be Replacement Warranty will be 5 years |
| 180 | (Earthing) INSTALLATION |
| 181 | S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 5 years |
| 182 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 183 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 184 | Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge. |
| 185 | CABLING AND END TERMINATION MAIN AREA |
| 186 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade POLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 187 | 4core x 16 sq mm (DG ) |
| 188 | 4 core x 4 sq mm (for small power) |
| 189 | 3.5core x 35 sq mm (To Panel) |
| 190 | LAYING OF CABLE |
| 191 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 192 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 193 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 194 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 195 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 196 | 4 core x16sq mm |
| 197 | 3.5 core x35 sq mm |
| 198 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 199 | 50 mm dia |
| 200 | FDB POWER AT EACH FLOOR),LIFT,PLUMBING |
| 201 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 5 years & compelete test certificate must be submitted along with panel board including component list. |
| 202 | In commer- 1 number of 125(100-125)A 4P Icu=50%Ics, LSIG MCCB based release with inbuilt display and adjustable overload along with 63A 4P O/L changeover switch (make- LEGRAND/Siemens (3VL) /SCHNEIDER (NSX), ISI marked)/EQ. make & model, |
| 203 | Busbar- 04 numbers of 150Amps,50kA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 204 | Out going- 2 numbers of 63A 4P MCB (make- Legrand or equivalent reputed make ISI marked)BDB P/AC |
| 205 | Out going- 2 numbers of 32A 4P MCB (make- Legrand or equivalent reputed make ISI marked)BDB L |
| 206 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 207 | (ii) 01 set of 0-60Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) |
| 208 | (iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model) |
| 209 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 210 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions of size 54mm(H) x 200mm(W), of Legrand/C&S/OBO or equievalant reputed make & model A catogory, ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. Warrentee period oftray must be 2 years & compelete test certificate must be submitted . |
| 211 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions of size 34mm(H) x 225mm(W), ofLegrand/C&S/OBO or equievalant reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. |
| 212 | Subhead- 1 (Lan System) |
| 213 | Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit, Make: Legrand/Systimax/Panduit/Schnieder/eq. |
| 214 | Supply & fixing of RJ-45Jack of Category 6 with Dual-port British-style Face plate 86x86 mm with Curveture and wall mount box Make: Legrand/Systimax/Panduit/Schnieder/eq |
| 215 | Supply & fixing of Cat6 24 Port Loaded Patch Panel:make:Legrand/Systimax/Panduit/Schnieder/eq |
| 216 | Supply & Installation of Cat6 Factory crimpped moulded patch cord,1mtr, Make :Legrand/Systimax/Panduit/Schnieder/eq |
| 217 | Subhead- 1.a (IP-PBX System) |
| 218 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required. |
| 219 | 2 Pair |
| 220 | S/F DP box suitable for above as reqd |
| 221 | 50 Pair |
| 222 | Supply installation testing and commssioning Basic SIP Backlit IP Phone as reqd. (Model to be decided by Engineer in charge) |
| 223 | Supply & laying of Cat6A LSZH horizontal cable following proper EIA/TIA standards in the PVC conduit as reqd. Legrand/Systimax/Panduit/Schnieder/eq |
| 224 | Subhead- 3 (IP-CCTV System) |
| 225 | Supply & Installation of 5Megapixel H.265 Vendal Proof Mini Dome Camera with build in audio. Support microSD/SDHC/SDXC Card Local Storage, up to 256G. BLC, HLC, 2D DNR, 3D DNR, Defog, AWB, EIS, IP Address Filtering, AGC, Anti-flicker, Corridor Mode, Deblur, Watermark. SIP/VoIP Support Yes, Voice & Video-over-IPEvent Trigger Motion Detection, Network Disconnection, Audio Alarm, etc.Motion Detection, Network Disconnection, External Input, Audio Alarm, etc. (Multi-interface Version).Event ActionFTP Upload, SMTP Upload, SD Card Record, SIP Phone, HTTP Notification, etc.;FTP Upload, SMTP Upload, SD Card Record, External Output, SIP Phone, HTTP Notification, etc. (Multi-interface Version) Video Analysis Region Entrance, Region Exiting, Advanced Motion Detection, Tamper Detection, Line Crossing, Loitering, Human Detection, People Counting, Object Left, Object RemovedSystem Compatibility ONVIF Profile G & Q & S & T, API Model No. MS-C5373-PB. Make: Milesight/Grandstream/Honeywell/eq. |
| 226 | Supply & Installation of 5Megapixel H.265 Vendal Proof Mini Bullet Camera. Support microSD/SDHC/SDXC Card Local Storage, up to 256G. BLC, HLC, 2D DNR, 3D DNR, Defog, AWB, EIS, IP Address Filtering, AGC, Anti-flicker, Corridor Mode, Deblur, Watermark. SIP/VoIP Support Yes, Voice & Video-over-IPEvent Trigger Motion Detection, Network Disconnection, Audio Alarm, etc.Motion Detection, Network Disconnection, External Input, Audio Alarm, etc. (Multi-interface Version).Event ActionFTP Upload, SMTP Upload, SD Card Record, SIP Phone, HTTP Notification, etc.;FTP Upload, SMTP Upload, SD Card Record, External Output, SIP Phone, HTTP Notification, etc. (Multi-interface Version) Video Analysis Region Entrance, Region Exiting, Advanced Motion Detection, Tamper Detection, Line Crossing, Loitering, Human Detection, People Counting, Object Left, Object RemovedSystem Compatibility ONVIF Profile G & Q & S & T, API Model No. MS-C5373-PB. Make: Milesight/Grandstream/honeywell/eq |
| 227 | Supply & Installation of 55\\" IPS Ultra HD AI ThinQ TV Make: LG/Samsung/Panasonic/eq |
| 228 | Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit, Make: Legrand/Systimax/Panduit/Schnieder/eq. |
| 229 | Supply & fixing of Cat6 24 Port Loaded Patch Panel: make:Legrand/Systimax/Panduit/Schnieder/eq |
| 230 | Subhead- 4 (SINAGE SYSTEM) |
| 231 | Supplying, installation, testing & commissioning of digital signage ar per direction of Engg. In charge. |
| 232 | EXTINGUISHER SYSTEM |
| 233 | Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. (Make:CS-FIRE/SUNMAX/CANEXE or equievalant ) |
| 234 | Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket as per direction of Engineer-in-charge. |
| 235 | Supply of A,C with indoor and outdoor unit |
| 236 | 1.5 TR high wall split A.C 3Star inverter type with 4kva stabilizer(Make:Toshiba/Hitachi/Carrier/Diakin or eq. |
| 237 | REFRIGRANT PIPING |
| 238 | Supply,installation of hard/soft copper refregrant piping,complete with fitting of bends and other nesessary material to complete the job. |
| 239 | 1 TR to 3 TR high wall split A.C |
| 240 | FRAME WORK |
| 241 | Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. |
| 242 | 1 TR to 3 TR high wall split A.C |
| 243 | DRAIN PIPING |
| 244 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. |
| 245 | 25mm nom. Dia pipe,B1 |
| 246 | SHEET METAL WORKS |
| 247 | CONTROL CABLE |
| 248 | Supply,laying of control cable and other nesessary material to complete the job. |
| 249 | For 1 TR to3 TR high wall split A.C |
| 250 | GPH PORTION OF THE WORK:- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Supreme/Ashirvad/Oriplast) GF Floor 20mm dia C-PVC pipe |
| 251 | 25mm dia C-PVC pipe |
| 252 | 1st Floor 20mm dia C-PVC pipe |
| 253 | 25mm dia C-PVC pipe |
| 254 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm UPVC ASTM Pipe |
| 255 | 32mm UPVC ASTM Pipe |
| 256 | 1st Floor 25mm UPVC ASTM Pipe |
| 257 | 2nd Floor (Terrace) 25mm UPVC ASTM Pipe |
| 258 | 32mm UPVC ASTM Pipe |
| 259 | 40mm UPVC ASTM Pipe |
| 260 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.G. Floor |
| 261 | 1st Floor |
| 262 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge G.Floor |
| 263 | 1st Floor |
| 264 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge. G. Floor |
| 265 | 1st Floor |
| 266 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall. G. Floor |
| 267 | 1st Floor |
| 268 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge15mm dia CP Bib cock (FLR-CHR-5047N Jaquar make) |
| 269 | 15 mm dia CP Long body Bib cock(Jaquar)CON-CHR-049NKN |
| 270 | 15mm dia CP angle stop cock (FLR-CHR-5053N Jaquar make) |
| 271 | 15mm dia CP Pillar cock (FLR-chr-5011N Jaquar make) |
| 272 | 15mm dia CP Basin mixture (CON-CHR-309KNBM- Jaquar make) |
| 273 | 15mm dia CP Wall mixture three in one (CON-CHR-217KNGB Jaquar make) |
| 274 | 15mm dia CP two in one bib cock (FLR-CHR-5041N Jaquar make) |
| 275 | 15mm dia CP Health faucet (ALD-CHR-573 Jaquar make) |
| 276 | 15mm dia CP Sink Cock (FLR- CHR- 5347 NJaquar make) |
| 277 | 15mm dia CP concealed stop cock Cat no - CON.CHR 089 KN |
| 278 | Revolving Shower with arm Jaquar Cat NO--OHS-CHR-1985 + SHA-CHR-477 |
| 279 | 25mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 280 | 32mm dia brass or gun metal fullway valve(Leader / KritiMake) |
| 281 | 40mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 282 | 15mm dia CP flange |
| 283 | 15mm dia CP extension piece |
| 284 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 litre capacity water storage Sintex tank(3 layer) on 2nd floor. |
| 285 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge . 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hindware/Somany/Cera/Kerovit) |
| 286 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 287 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm dia U-PVC SWR pipes(Supreme/Ashirvad/Oriplast) |
| 288 | 100mm dia U-PVC 'P' trap |
| 289 | 110mm dia U-PVC Door Tee |
| 290 | 100mm dia U-PVC Plain Bend |
| 291 | 100mm dia U-PVC Door Bend |
| 292 | 75mm dia U-PVC SWR Pipe. |
| 293 | 75mm dia U-PVC Door Bend. |
| 294 | 75mm dia U-PVC Plain Bend. |
| 295 | 110 UPVC Offset |
| 296 | 110mm dia Vent cowl. |
| 297 | W/C connector |
| 298 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 299 | 125mm dia CP grating |
| 300 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge. 580mm size Orissa pan (Parryware / Hindware make ) |
| 301 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of (Parryware/Hindware/Cera/Somany/Kerovit) with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge.EWC with 'S' trap plain with seat cover(Parryware/ Hindware/ Cera/ Somany/ Kerovit) |
| 302 | One piece commod (Hind ware Element Cat No 92084 |
| 303 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware/Cera/Somany/Kerovit) |
| 304 | 550mmx440 mm size wash hand basin (With porcelain half pedestal) (Hindware-Cat No 91049+91115) |
| 305 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 306 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf 600mm long(ACN-CHR-1171N) |
| 307 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mm x 600mm long CP towel rail (Jaquar) ACN-CHR-1111SM |
| 308 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 309 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P(Jaquar make) |
| 310 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 311 | 15mm dia urinal spreader |
| 312 | 32mm dia C.P. dome waste |
| 313 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge |
| 314 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink With sink cock with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge600x450x250 mm SS sink(With drain board -NIRALI) |
| 315 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 316 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge .In ground floor |
| 317 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. G. Floor |
| 318 | 1st Floor |
| 319 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. G. Floor |
| 320 | 1st Floor |
| 321 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.1st Floor Wall - |
| 322 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 600 mm x 300 mm G. Floor Qntity same as plaster item above |
| 323 | 1st Floor Qntity same as plaster item above |
| 324 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 60 x 60 cm Kajaria / equvalent to be pree approved . G.Floor |
| 325 | 1st Floor |
| 326 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 327 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 328 | Louvers |
| 329 | EXTERNAL P.H. WORK. |
| 330 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm all round concrete |
| 331 | 160mm all round concrete |
| 332 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
| 333 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 334 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeMan hole chamber Inside size 910mmx910mmx910mm |
| 335 | Cost of R.C.P.C.Cover. |
| 336 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeBrick masonry soakway pit 1.40m dia x 2.00m deep |
| 337 | Sinking of (125X50)mm dia bore well through hand boring by Wter jet method.- 1 No |
| 338 | Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 339 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 340 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres |
| 341 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres |
| 342 | Reaming 150mm to 200mm dia from 0 to 360 metres |
| 343 | Reaming 200mm to 250mm dia from 0 to 360 metres |
| 344 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres |
| 345 | Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 346 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 125mm dia PVC casing pipe from 0 to 360 metres |
| 347 | Cost of 125mm dia PVC ASTM pipe (sch-80) |
| 348 | 50mm dia PVC casing pipe from 0 to 360 metres |
| 349 | Cost of 50mm dia PVC ASTM pipe (sch-80) |
| 350 | Cost of 50mm dia PVC well screen |
| 351 | Cost of 50 mm dia C.I. cutter plug |
| 352 | Cost of bentonite powder |
| 353 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 354 | Cost and Conveyance of Gravel |
| 355 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 356 | Cost and Conveyance of sand |
| 357 | Supplying all labour T&P and grouting with cement slurry for sanitary sealingin the bore around the upper most 3 metres of 150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 358 | Cost of Cement |
| 359 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor |
| 360 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.00 H.P single phase 3 stage head range 216to 25 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm |
| 361 | DOL controll pannel |
| 362 | 2.5 Sqmm flat cable |
| 363 | 32mm dia Steel short piece |
| 364 | Steel roop with cover |
| 365 | Well cap |
| 366 | 50mm size CI bracket |
| 367 | 20mm dia rigid UPVC pipe |
| 368 | 32mm Dia brass non return valve(Shakti make) |
| 369 | 32mm dia HDPE pipe |
| 370 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 371 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 372 | Construction 1 nos 30 users RCC Septic tank |
| 373 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 374 | - do - with addl. Depth of 1.5 m |
| 375 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 376 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 377 | In ground floor |
| 378 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 379 | In ground floor |
| 380 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 381 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 382 | Roof Slab- |
| 383 | For RCC wall |
| 384 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 385 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 386 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 387 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 388 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 389 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 390 | 110mm diameter U-PVC SWR pipe |
| 391 | 110mm dia U-PVC Plain shoe bend |
| 392 | 110mm dia U-PVC Cowl |
| 393 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy