| 1 | Renovation of Pond |
| 2 | 2.7.D:Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. (D) Dry Rubble Masonry |
| 3 | OD111100/2025-2026:DR with Departmental Stone-Dry Rubble Masonry-Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels,labour charges etc.complete as per direction of Departmental officers at site. |
| 4 | 11.1.1.1:Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil (i) Upto 3 m depth |
| 5 | 75.7.1:DRY RUBBLE MASONRY with hard stone, including Through/Bond stone in foundation and superstructure including packing to compactness to lines and levels, cost and conveyance of all materials labour charges etc. complete as per approved drawing and relevant technical specifications. |
| 6 | 11.6.3.2:Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.III. Random Rubble Masonry (ii) In cement mortar 1:4 |
| 7 | 11.4.3.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III. P.C.C. grade M 20 (i) Nominal mix (1:2:4) |
| 8 | 11.8:Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 9 | OD111096/2025-2026:Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site,spreading,grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000m as per technical specification Clause 303.1 |
| 10 | 4.1.A.3:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.<br> (iii) For Grading III Material |
| 11 | 75.8.1.1.A:Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate:4 course aggregate) laid to required slope as required including compaction, finishingand tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixedin concrete mixer etc complete as per specification(i) Nominal mix (1:2:4) |
| 12 | OD447506/2025-2026:Providing and laying of Interlocking Concrete Block Pavements having thickness 60mm over 50mm thick crushed stone of 6.70mm size, as per drawing and Technical Spaecification Clause 1504 |
| 13 | OD440449/2025-2026: Granite for name board of size 75 cmx 60 cm with letters Please Enable Macros to View BoQ information |