| 1 | Section- I Civil Works |
| 2 | 5.10.15 Taking down C.A. Of G.C.I. Sheet in roofs with ridges including stacking the serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads as per direction of E/I. |
| 3 | 5.5.12Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 4 | 5.8.41Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 5 | 5.8.45Providing one coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 6 | 5.8.9Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 7 | 5.10.7Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 8 | 5.7.3Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | 5.10.33Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 10 | 5.3.8Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including .necessary excavation, levelling & dressing & finishing the top smooth. |
| 11 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 12 | DSR 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 13 | DSR/12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 14 | DSR 15.18Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 15 | DSR 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes |
| 16 | 5.3.11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 17 | 5.3.17.21Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 18 | 5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.1 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 19 | 5.1.1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 20 | 5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 21 | 5.1.10 Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 22 | 5.6.1Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 23 | 5.3.1.2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 24 | 5.3.1.2 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 25 | 5.3.9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 26 | 5.3.17.1Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 27 | 5.3.10Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 28 | 5.3.17.6Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 29 | 5.3.11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 30 | 5.3.17.21Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 31 | 5.3.11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 32 | 5.3.17.20Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick |
| 33 | 5.4.57 .2Supplying fitting and fixing glass panes including supplying putty. Beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. |
| 34 | 18.48 D.S.R. Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 35 | DSR 18.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 36 | 18.7.3 25 mm nominal dia Pipes |
| 37 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 38 | 18.17.1 32 mm nominal bore |
| 39 | DSR 18.8Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 40 | 18.18.3 25 mm nominal bore |
| 41 | 5.5.4Providing reinforcement (Round bars confirming to IS. 432 dia.in mm (I.S. 2062 Gr.A) of 6 & 8mm dia rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 42 | 5.5.5 providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 43 | (b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})80% |
| 44 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 45 | (A) Bricks (1K+ 7P = 8 KM.) |
| 46 | (B) Coarse Sand (25KM) |
| 47 | (C) Stone Chips(12 KM) |
| 48 | (D) Cement (3 KM.) |
| 49 | (E) Steel (3 KM.) |
| 50 | (f) Local Sand (3KM) |
| 51 | INTERNAL & EXTERNAL ELCTRIFICATION WORK |
| 52 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Finolex (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/ Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)/Legrand/Schneider (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/L&T/Legrand/Schneider (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard (7) LED ITTING FIXTURE -: Havells/Bajaj/ Crompton (Model/as per E/I ) (8) CEALING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Crompton (Model/as per E/I ) (9)OCTAGONAL POLE-: Bajaj/Philips/Surya (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ TOSHIBA/DAIKIN (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED |
| 53 | 1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 54 | 1.3.3Group C |
| 55 | 1.5 Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 56 | 1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 57 | 1.7.12x1.5 sq mm+ 1x1.5 sq mm earth wire |
| 58 | 1.7.22x2.5sq mm + 1x2.5 sq mm earth wire |
| 59 | 1.7.42x6 sq mm + 1x6 sq mm earth wire |
| 60 | 1.7.52x10sq mm + 1x10 sq mm earth wire |
| 61 | 1.7.104x6 sq mm 2x6 sq mm earth wire |
| 62 | 1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 63 | 1.24.15/6 amps, one way switch |
| 64 | 1.24.45/6amps,3pin socket outlet |
| 65 | 1.25S/F Modular type electronic fan regulator:- supplying and fixing stepped type fan regulator on the existing modular plate switch box including connection but excluding modular plate etc, as required. |
| 66 | 1.27S/F Modular boxes bases & cover plate:- following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc,as required. |
| 67 | 1.27.11 or 2 module (78mm x78mmx45mm) |
| 68 | 1.31S/F light plug point with modular type accessories:- supplying and fixing suitable size G.I box with modular plate and cover in front on recess including providing and fixinng 3 pin 5/6 amps modular socket outlet and 5/6 amps modular type swtich painting etc as required. |
| 69 | 1.32S/F power plug point with modular type accessories:- supplying and fixing suitable size G.I box with modular plate and cover in front on recess including providing and fixing 6 pin 15/16 amops modular socket outlet and 15/16 amps modular switch |
| 70 | 1.33 S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 71 | 1.41 ITC fluorescent/led fitting directly on surface:-Instaliation, testing and commissioning of prewired, fluorescent fitting of all types, complete with all accessosries and tube etc. directly on ceiling /wall including connection with 1.5 sq mm.FR PVC insulated, copper conductor. |
| 72 | 1.44 ITC ceiling/wall fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 73 | 2.7 S/F, panel mounting changeoverProviding and fixing following capiacity 4 pole panel mounting chengeover switches in existing cubical panel board,making connection, earthing the body etc as required. |
| 74 | 2.7.3100amps, 4 pole |
| 75 | 2.8S/F S.P MCB DB:-Supplying and fixing following way single pole nutral, sheet MCB distribution board, 240 volt, in recess, complete with tinned copper busbar, earth bar din bar detachabe gland plate, interconnections, phosphatized and power painted including erthing etx. as required. but without (MCB/RCCB/ISOLATOR) |
| 76 | 2.8.912 Way, Double door |
| 77 | 2.11 S/F 'B' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 78 | 2.11.16/32 amps, single pole, \\"B\\" series |
| 79 | 2.12 S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 80 | 2.12.1 6/32 amps,single pole, \\"C\\" SERIES |
| 81 | 2.12.6 40 amps , DP |
| 82 | 2.12.7 50/63 amps, DP |
| 83 | 2.12.9 40 amps, TPN |
| 84 | 2.14 S/F DP MCB isoletor:-Supplying and fixing following rating double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commisioning etc as required. |
| 85 | 2.14.140 amps |
| 86 | 2.19 P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 87 | 3.2G.I Earth pipe electrode with salt charcoal:- Earthing with G.I earth pipe 4.5 mtr long 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arracgement and watering pipe etc. as required. With salt charcoal or coke. |
| 88 | 3.9 S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 89 | 4.2 P/F G.I lighting conductor final, Providing and fixing of lighting cunductor finial, made of 25mm dia 300 mm long, copper tue having single prong at top, with 85mm dia 3mm thick G.I base of the finial or any other metalic object as required. |
| 90 | 4.4 Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required. |
| 91 | 4.7P/F G.I Lightning Conductor tape in vertical run:- providing and fixing GI tape 20mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required (for horizontal run) |
| 92 | 4.8P/F G.I Lightning Conductor tape in vertical run:- providing and fixing GI tape 20mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required (for vertical run) |
| 93 | 4.12P/F Testing joint for G.I lighting conductor:- Providing and fixing testing joint, mad of 20mm x 3mm thick G.I strip, 125 mm long, with 4 nos. Of G.I bolts, nuts, chek nuts and spring washer etc complete as required. |
| 94 | 5.1 MV cable laying upto 25 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 25 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 95 | Code no.S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1) |
| 96 | M-740 16 sq.mm. 4 core |
| 97 | DSR 12.37 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 98 | 9.1.334x16 sq. mm (28mm) |
| 99 | Anaylised & Approved ITC LED 25/90W WTREET LIGHT ON WALL WITH 25 MM DIA.,75metre long GI pipe bend, J/U Hook 4 nos , along with two coat painting of GI pipe bend etc as required |
| 100 | Anaylised & Approved Supply of 1200 mm sweep ceiling fans complete without regulator, double, ball bearing, motor, blades, down rod, canopies, capacitor suitable for opertion on 230 volts, 50HZ, 1 phase , AC supply connection with 1.5sq mm PVC Copper wire complete as required years warranty. Fan shall be approved by engineer incharge/consultant) (COLOR OF CEILING FANS-WHITE-ISI.) Make-Havells Velociy 1200mm /bajaj 48\\" Grace Gold Dx/USHA-TECHNIX-PRL |
| 101 | Anaylised & Approved Supply, fitting, fixing & testing of Wall Fan 400mm 230V with blade, guard (net) , revolving type with regulator system and proper stand and fixing clamps.. Make:- Bajaj 60014 / Crompton WMSDX 120 / Havells Swing. |
| 102 | Anaylised & Approved Providing of box type batten with 18 watt LED lamp along with all accessosries. OFMAKE-Havells/Philips/Bajaj |
| 103 | Anaylised & Approved Providing & fixing of holder type CFL -23 watt lamp. |
| 104 | Add 18% GST |
| 105 | Add 1% Lebour Cess Please Enable Macros to View BoQ information |