| 1 | Electrical work : |
| 2 | Wiring for light & fan point with 2 X 1.5 sq. mm. PVC insulated copper conductor cable (FR) in PVC casing and capping complete with PVC surface modular switch board with cover plate and 10A. modular switch including connection etc. as required a) Short Point :- |
| 3 | b) Medium point:- |
| 4 | c) Long point:- |
| 5 | Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required. |
| 6 | Providing and fixing of 3 pin 5/6 amps plug point with Piano type 5/6 amps switch and socket with cover plate including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on PVC switch board, earthling the 3rd pin etc. as required. |
| 7 | Providing and fixing of 3/6 pin15/16 amps plug point with piano type 15/16 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required |
| 8 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 9 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required |
| 10 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- a) 2 X 1.5 sqmm |
| 11 | 3 X 1.5 sq mm |
| 12 | 2 X 2.5 sq mm |
| 13 | c) 2 x 4.0sqmm |
| 14 | 2 X 6 sq mm |
| 15 | 4 X 6 sq mm |
| 16 | 4 X 10 sq mm |
| 17 | 4 X 16 sq mm |
| 18 | Wiring for Circuit /Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping / conduit in recess /surface including connection etc. as required:- 1 X 1.5 sq mm |
| 19 | 1 x 2.5 sq mm |
| 20 | 2 X 1.5 sq mm |
| 21 | 2 X 2.5 sq mm |
| 22 | 2 X 4 sq mm |
| 23 | 2 X 6 sq mm |
| 24 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall etc. as required:- 2 X 1.5 + 1 X 1.5 sq mm |
| 25 | 2 X 2.5 + 1 X 1.5 sq mm |
| 26 | 2 X 4 + 1 X 1.5 sq mm |
| 27 | 2 X 6 + 1 X 2.5 sq mm |
| 28 | 4 X 6 + 2 X 2.5 sq mm |
| 29 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required 3 core 4 sqm |
| 30 | Supplying and fixing of the following sizes plastic modular switch boards(on surface) with cover Plate etc. as required. 1-2 module Plastic switch board |
| 31 | 3 module Plastic switch board |
| 32 | Supplying and fixing of the following sizes switch boards with cover etc. as required. 102mm x 178mm (4\\" X 7\\")PVC switch boards |
| 33 | 152mm x 203mm (6\\" X 8\\")PVC switch boards |
| 34 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - 4 sq mm |
| 35 | 6 sq mm |
| 36 | 10 sq mm |
| 37 | 16 sq mm |
| 38 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. 5 step Modular fan regulator (2M) |
| 39 | 32 amps 1-way DP switch (2M) |
| 40 | 16/20 amps 1-way SP switch (1M) |
| 41 | 32 amps DP Kitkat switch |
| 42 | 3/6 pin 20 amps socket outlet (2M):- |
| 43 | Angle/batten holder |
| 44 | Musical call bell |
| 45 | Ding Dong Call bell |
| 46 | Bell Push SP (1M) |
| 47 | 3mm thick bakelite sheet |
| 48 | 1/2 way PVC Enclosure |
| 49 | Blank Plate |
| 50 | 19 mm X 19 mm size PVC \\"L\\" flat Bit (LMR) |
| 51 | 25 mm dia. Heavy PVC gland .(LMR) |
| 52 | 20 mm dia. Heavy PVC gland .(LMR) |
| 53 | 25 mm dia. Heavy PVC flexible Pipe .(LMR) |
| 54 | 20 mm dia. Heavy PVC flexible Pipe .(LMR) |
| 55 | 5 Amp Power Top |
| 56 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm) |
| 57 | 63 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm) |
| 58 | 32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm) |
| 59 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories in existing panel board including necessary connection etc. as required:- 100 amps 415 volts TPN main switch (rewireable):- |
| 60 | 63 amps 415 volts TPN main switch (rewireable):- |
| 61 | 32 amps 415 volts TPN main switch (rewireable) |
| 62 | Supplying and installation of rewireable fuse unit (kitkat) of the following ratings in existing panel board including necessary connection etc as required:- 100 amps kitkat porcelain fuse unit with base(rewireable) |
| 63 | 63 amps kitkat porcelain fuse unit with base |
| 64 | 32 amps kitkat porcelain fuse unit with base(rewireable) |
| 65 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator /RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. (2+10) / 12 way SPN MCB DB (double door):- |
| 66 | (2+6) / 8 way SPN MCB DB (double door):- |
| 67 | 4 way horizontal TPN MCB DB (Double door):- |
| 68 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- 6 to 32 amps DP MCB:- |
| 69 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- 100 amps FP isolator |
| 70 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- 40 amps DP isolator:- |
| 71 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 72 | Supplying and fixing of following surface mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- Surface mounted round shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 73 | Surface mounted round shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 74 | Recessed round shaped 6 watt LED downlight with integral driver and high quality polycarbonate diffuser |
| 75 | Surface mounted box type batten suitable for single 20 watt integrated LED tube lamp including 20 watt LED tube with integral driver and polycarbonate diffuser |
| 76 | 14/15 watt retrofit CFL |
| 77 | Supplying and fixing of following LED retrofit bulbs / lamps B.C.Type including necessary connection etc. as required:- 0.5 watt LED retrofit colored lamp with polycarbonate body and aluminium heatsink: (Approved Rate) |
| 78 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66). |
| 79 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3 nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 80 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 81 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 82 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required. |
| 83 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall / RCC base with necessary MS clamp, nut, bolts & painting etc as required:- |
| 84 | Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:- |
| 85 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. |
| 86 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for earthing as required. |
| 87 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 88 | Supplying & Fixing of 40 mm dia G.I Pipe (medium gauge) ( above 4.5m long normal size) for drawing of 25mm x 3mm Copper strip for earth connection from earth electrodes as required i/c necessary hole etc as required. |
| 89 | Supply and fixing of 25mm x 3mm Copper strip on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 90 | Supply and fixing of the following sizes Copper prong with necessary nuts & bolts etc as required grouted on roof for Lightning protection. |
| 91 | Supplying of ‘U’ clamp made with 40mm x 6 mm MS flat and fixing with necessary fasten nuts including painting etc as required. |
| 92 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for 4 sqmm Cable Please Enable Macros to View BoQ information |