| 1 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.10 zone |
| 2 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 3 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 4 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 5 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 6 | Supply and fixing 4\\" x4\\" M.S. junction box for fixing of detectors painted in red with knock-out holes in all four sides for cable entry etc. as complete required. |
| 7 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 8 | Supplying, installation, testing & commissioning of Bosch make 480 watt booster amplifier having Multiple outputs - 70 V / 100 V and 8/4 ohm, Mains, battery back-up, and pilot tone supervision Temperature controlled forced front to back ventilation, directly stackable, Dual inputs with priority switching, Frequency response - 60 Hz to 18 kHz (+1 / -3 dB at -10 dB ref. rated output), Distortion - <5% at rated output power, 1 kHz, S/N (flat at max volume) etc. compete in all respect to the entire satisfaction of Fire Officer.Model No. LBD1938/00 |
| 9 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 10 | P/F/T/C of following size, 1.1 KV grade, copper conductor, PVC insulated, PVC sheathed cable, ISI marked, conforming to IS:1554 (Part-I) 1988, of Kalinga/National/Polycab or equivalent make, including proper termination with suitable glands, lugs and accessories, complete in all respects to the satisfaction and direction of Fire Officer/Engineer-in-Charge |
| 11 | 4 Core x 1.5 sqm |
| 12 | 37 Core x 1.5 sqm |
| 13 | Condition-Credit of unserviceable materials including dismantling the following existing irrepairable parts including removal from site complete all as specified and as directed by Fire Officer/Engineer-in-Charge.1. Fire Alarm Panel @ Rs. 1000/- Each2. Old unserviceble detector @ Rs. 100/- Each3. Manual Call Boxes @ Rs. 50/- Each4. Sounder @ Rs. 100/- Please Enable Macros to View BoQ information |