| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR Name of Work :- DNIT FOR CONSTRUCTION OF ADDITIONAL TWO ROOMS FOR INMATE OF NARI NIKETAN TRUST, NAKODAR ROAD JALANDHAR. (MPLAD SCHEME) Contract No: Civil Works Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | A1) BUILDING WORK GROUND FLOOR |
| 3 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 4 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 5 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 6 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 7 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels |
| 8 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 9 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 10 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres aboveplinth level. |
| 11 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 12 | 12.5 mm thick cement plaster 1:5 |
| 13 | 20mm thick cement plaster 1:5 in two coat work |
| 14 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sandmortar 1:4 and top surface to be left clean after wire brushing |
| 15 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 16 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 17 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 18 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.a UPVC 110 mm bend |
| 19 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.a UPVC 110 mm Coupling/ Sockets |
| 20 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 21 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside thepremises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres |
| 22 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outsidethe building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 23 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material |
| 24 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.a Size 600x600 mm |
| 25 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 26 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 27 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 28 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :(a) For fixed portion and chawkhats |
| 29 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :(b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 30 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side. |
| 31 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)i) Float glass panes of 5 mm thickness |
| 32 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 33 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :a) 300mm x 16mm |
| 34 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 35 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone,including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 36 | A2) BUILDING WORK FIRST FLOOR |
| 37 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 38 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lowerstorey for Brick Work/ Concrete Block/ ClayBlock. |
| 39 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 40 | Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. |
| 41 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 42 | Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. |
| 43 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 44 | Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19 |
| 45 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels |
| 46 | Extra rate for shuttering in each subsequent storey abovethe first. Storey work done in subsequent storey above thefirst storey up to height of 4 metres or part thereof up to theroof top level of that storey. |
| 47 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 48 | Extra rate for shuttering in each subsequent storey abovethe first. Storey work done in subsequent storey above thefirst storey up to height of 4 metres or part thereof up to theroof top level of that storey. |
| 49 | 12.5 mm thick cement plaster 1:5 |
| 50 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level. |
| 51 | 20mm thick cement plaster 1:5 in two coat work |
| 52 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level. |
| 53 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sandmortar 1:4 and top surface to be left clean after wire brushing |
| 54 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 55 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 56 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 57 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.a UPVC 110 mm bend |
| 58 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.a UPVC 110 mm bend |
| 59 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 60 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material |
| 61 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.a Size 600x600 mm |
| 62 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.a Size 600x600 mm. |
| 63 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 64 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 65 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 66 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :(a) For fixed portion and chawkhats |
| 67 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :(b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 68 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side. |
| 69 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)i) Float glass panes of 5 mm thickness |
| 70 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :A) 300mm x 16mm |
| 71 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron covermoulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 72 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 73 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone,including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 74 | Stripping and stacking slate or tiles of a roof. |
| 75 | A3) ELECTRICAL WORK:- |
| 76 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 Buniversal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material,cutting and filling up of chases (with finishing the surface):- |
| 77 | I) Wiring fan point (With fan box) |
| 78 | II) Wiring light point |
| 79 | (iv) Wiring 6Amp. wall socket point |
| 80 | (v) Wiring 6Amp. Plug control comprising wall socket point |
| 81 | (vi) Wiring 16/20Amp. power plug control point |
| 82 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 83 | (ii) Overall size 1.5sq.mm (Un-sheathed) |
| 84 | (iii) Overall size 2.5sq.mm (Un-sheathed) |
| 85 | (iv) Overall size 4sq.mm (Un-sheathed) |
| 86 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steelhooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-(x) Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 87 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-(a) SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 88 | Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee/warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in charge at site. |
| 89 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory Total in Figures 1348981.0 1348981.0 INR Thirteen Lakh Forty Eight Thousand Nine Hundred & Eighty One Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |