| 1 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 2 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With(1:6) cement plaster. i) 20 mm thick |
| 3 | iii) 10 mm thick plaster |
| 4 | (i) With 1:6 cement mortar(c) 15 mm thick plaster for out side of wall |
| 5 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (1st floor). [Excludingcost of chipping over concrete surface] (i) With 1:6 cement mortar(b) 20 mm thick plaster for Inside of wall |
| 6 | (i) With 1:6 cement mortar(c) 15 mm thick plaster for out side of wall (1st floor) |
| 7 | (ii) With 1:4 cement mortar(c) 10 mm thick plaster (1st floor) |
| 8 | Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only). |
| 9 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor. |
| 10 | Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5mm (± 0.2 mm) made out of single piece extruded PVC profile, with mitred cut joint sand joint with 2 nos. of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 mm x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The doorframe to be fixed to the wall using 8 x100mm long anchor fasteners complete, all as per manufacturer‟s specification and direction of Engineer -in- charge. |
| 11 | Supplying best Indian sheet glass pans set in putty and fitted and fixed with nails and putty complete in all floors. 4.0 mm thick. |
| 12 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in groundfloor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor). (ii) Grill weighing above 16 Kg./sq.mtr and above |
| 13 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative |
| 14 | Dismantling wash basin with brackets with or without waste fittings. |
| 15 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (i) 450 mm X 300 mm size |
| 16 | (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 17 | (i) (2) Chromium plated overhead Rain shower (Round), size-200mm dia.with revolving joint (Model Code No. F7010601 of CERA or equivalent) |
| 18 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm. |
| 19 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (vii) 150 mm grip x 12 mm dia rod. |
| 20 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (v) 150mm long x 12mm dia. bolt. |
| 21 | Dismantling flush pipe of water closet. |
| 22 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. ii) C. P. Flush Pipe |
| 23 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete, C.I. brackets including two coats of painting to bracket etc. |
| 24 | Dismantling Orissa pattern W.C. including taking out of base concrete, if necessary, complete. |
| 25 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (b) With 'S' trap |
| 26 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (iv) Bestolite (solid type) white |
| 27 | White washing including cleaning and smoothening surface thoroughly. All floors : (b) Two coats (to be done on specific instruction). |
| 28 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats, Ground floor |
| 29 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In 1st floor (Two Coat) a) Normal Acrylic Emulsion. Ground floor |
| 30 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats, 1st. fl. External surface, (i) Upto 4th floor |
| 31 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In 1st floor (Two Coat) a) Normal Acrylic Emulsion |
| 32 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 33 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary(b) On steel or other metal surface :With super gloss (hi-gloss) -iv) Two coats (with any shade except white) |
| 34 | (b)Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 35 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) |
| 36 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. For trusses spanning up to 12.00 m |
| 37 | Supplying , fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make as per IS:15965:2012 and IS:14246:2013 (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof:- With 0.5 mm thick sheet |
| 38 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes,making threads, fitting, fixing etc. complete inall respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (ii) 15 mm dia. medium quality |
| 39 | (d) (ii) 32 mm dia. medium quality |
| 40 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI Pipes as per IS : 1239 (Part-I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes 32 mm dia |
| 41 | 15 mm dia. |
| 42 | a) (i) CP Pillar Cock- 15 mm. (Equivalent to Code No. 507 & ModelTropical / Sumthing Special of ESSCO or similar brand).. |
| 43 | (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 44 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A)(ii) Double Socketed 3 Meter Length (b) 110 mm |
| 45 | xi) Door Bend (T.S.) (b) 110 mm |
| 46 | x) Bend 87.5º (b) 110 mm |
| 47 | (ii) Plain Tee (b) 110 mm |
| 48 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (v) 75mm. X 60mm. X 3.15mm. |
| 49 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with16mm dia rod with centre bolt and round fitting. (a) 200mm long |
| 50 | Supplying , fitting and fixing 10 litre P.V.C. low down Cistern conforming to I.S. specification with P.V.C. fittings complete, C.I. Brackets including two coats of painting to bracket etc. |
| 51 | Supplying , fitting & fixing Flat back urinal (Half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm x 75 mm x75 mm wooden blocks complete. 465mm.x355mmx265mm |
| 52 | A) Supplying fitting and fixing door frame with M.S. angle as per drawing & direction of required section.The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded . The nuts are to be welded after careful checking with screw.All welding spots should be properly filed or rounded smooth including cost of welding hinges for 5mm x 6mm flat 225mm long as per direction welded to the frame fitted andfixed in position excluding cost of concrete. |
| 53 | Supplying 1.5 mm thick M.S. sheet fitted and fixed on one or both faces of M.S./W.I. gate etc. with point welding at not more than 150 mm apart completein all respect as per design in cluding cost of all labour and materials. |
| 54 | Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm. Dia. 600 mm. long. |
| 55 | Supplying, fitting and fixing approved brand 32 mm. dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 900 mm. long. |
| 56 | Constructing Inspection pit to a depth of 1.5 metre (inside) , 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips,plastering inside and outside (outside upto 300 mm below G.L.) with 20mm thick cement plastering (1:4) and neat cement punning, including supplying, fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). ii) With Pakur variety. (JSW/JSPL/SHYAM,SRMB,BMASL/ELECTROSTEEL/SSL) (ii)900mmX750mm(inside)chamber includingfittingandfixingS.W.master trap of 100 mm dia. of approved makeA) With Pakur variety. (Other than SAIL/TATA/RINL) |
| 57 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm. dia. R.C.C. manhole cover ( heavy type ) of approved make supplied, fitted and fixed in the 100mm. thick R.C.C.(1:1.5:3) top slab with necessary fittings, 20mm. thick cement plaster (4:1) with neat cement finish to the internal surfaces and 15mm, thick cement plaster (4:1) to outside wall upto 200mm. below G.L. floor finish with 25mm. thick grey artificial stone over 100mm. thick R.C.C. (1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and filling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level ofSeptic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (iv) For 50 users i) With Pakur variety. A) With Pakur variety. (SAIL/TATA/RINL) |
| 58 | Construction of circular sock well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.60 metre from the bottom having 150mm. intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm. thick cement plastering (1:4) to inside face the depth of cement brick work, 15.. thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6mm. thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm. to 63 mm. size) including R.C.C. cover slab of 100 mm. thick with cement concrete (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm. dia. R.C.C. manhole cover (heavy type) approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipeconnectors, excavation of well including shoring, dewatering and removing the excess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm. thick dry brick work and 250 mm. thick cement brick work (6:1) and 1.00 metre inside dia. (SAIL/TATA/RINL) |
| 59 | Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling including concreting at bottom and sides etc. 150 mm. Dia. |
| 60 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor. |
| 61 | Earthwork in excavation of foundation trenches or drains or septic tanks, soak wells etc. in all sorts of soil (including mixed soil but excluding laterite and sand stone ) including removing spreading or stacking the spoils within a lead of 75 metre as per direction. Depth of excavation not exceeding 1.5meter. |
| 62 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 15 cm. Including watering and ramming etc. layer by layer, complete. With earth obtained from excavation of foundation. |
| 63 | Filling in foundation or plinth by sand in layers not exceeding 15 cm as directed and consolidating same by through saturation with water and ramming complete including cost of sand. By Fine sand. |
| 64 | Supplying and laying Polythene sheet over damp proof course or below flooring or roof terracing or in foundation trenches |
| 65 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety |
| 66 | Construction of Plaque with Brickwork Structure providing letters embossed over Granite Board (900 mm x 1200 mm) & fixing it, Plastering , painting etc complete at site as per drawing , specification and direction of the Executive Engineer |
| 67 | Add, G S T 18.00% from Item no. - 1 to 69 |
| 68 | Add, C E S S 1.00% from Item no. - 1 to 70 Please Enable Macros to View BoQ information |