| Sl. No. | Item Description |
| 1 | Building Work |
| 2 | 5.8.9Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 3 | 5.10.7Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 4 | 5.7.3Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 5 | 5.7.6Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 6 | DSR 14.91Providing and laying APP(Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane T orch and sealing all jointsetc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. T ear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane :14.91.1 3 mm thick |
| 7 | DSR/22.14Grading roof for water proofing treatment with22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 8 | Material + 10% C.P.Supplying M.S. Angle Post 50 x 50 x 6mm Size as per building specification and direction of E/I. |
| 9 | 5.10.15Taking down C.A. Of G.C.I. Sheet in roofs with ridges including stacking the serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads as per direction of E/I. |
| 10 | DSR/12.1Providing corrugated G .S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G .I. limpet washers or with G .I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever requiredDSR 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m* |
| 11 | DSR 15.18Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 12 | DSR 10.16Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes |
| 13 | 5.3.11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 14 | 5.3.17.21Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 15 | DSR 15.41 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 16 | DSR /26.26Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick26.26.2With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 17 | 5.5.4Providing reinforcement (Round bars confirming to IS. 432 dia.in mm (I.S. 2062 Gr.A) of 6 & 8mm dia rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 18 | 5.5.5 providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 19 | (b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})80% |
| 20 | 5.8.41Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 21 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 22 | 5.10.10Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 23 | 5.10.11Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 24 | DSR 10.14Providing and fixing pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel of 1.60 mm thickness including hings , jamb , lock jamb, bead and if required angle threshold of mild steel angle od section 50x25mm or base ties of 1.60 mm pressed mild steel welded or rigidly togather by mechnical means including M.S pressed butt hiongs 2.5 mm thick with mortar guards , lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer - in-charge. Profile B |
| 25 | 10.14.1.1Fixing with adjustable lugs with split end tail to each jamb |
| 26 | 5.4.34Supplying, fitting & fixing 30mm thick solid core type decorative single leaf flush door shutters in doors with both side decorative venier with black board core bended with high quality in all formaldehyde synthetic resin of standered with aluminium fittings such as hinges, tower bolts, handle, cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I. |
| 27 | DSR 26.86.7Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed |
| 28 | 26.86.7 Frame size 65 x 150 mm |
| 29 | DSR 26.87.1 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 |
| 30 | 5.4.57 .2Supplying fitting and fixing glass panes including supplying putty. Beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. |
| 31 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | DSR/13.45 Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @2.20kg/10 sqm |
| 33 | 5.8.18Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I. |
| 34 | DSR/11.26 Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) :1 1.26.1 25 mm thick |
| 35 | 5.10.4Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 36 | DSR 11.39Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 37 | DSR/8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | 11.41/ D.S.RProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.11.41.2 Size of Tile 600x600 mm |
| 39 | 5.10.5/DSRDismantling lime terracing upto av. 115mm depth with chisel and hammer including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 40 | 5.7.11Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 41 | 5.2.11Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 42 | 5.10.33Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I |
| 43 | 5.3.8 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 44 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 45 | Bricks (7 p + 1 k = 8 km) |
| 46 | Coarse sand ( 25 km) |
| 47 | Stone Chips (12 km) |
| 48 | Cement (3 km) |
| 49 | Steel (3 KM.) |
| 50 | Sanitary Installation Work |
| 51 | 3.2.1Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50 grms, 15mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificatin and direction of E/I. (A) 580 mm long (C) with 10 ltrs. low level P.V.C. Cistern |
| 52 | DSR/3.2,2. Supplying, fitting and fixlng 450mm hlgh vltreous white gtazed earthen E.W.C. with 'p' trap of parry, hlndustan or any other approved l.S.S. make lndudlng supplying and flxlng 15 lltros C.l. mosquito proof low down flushing clstem of approved make wlth comploto flttlngs with C.l.handle and R.S. or bracket with telescoplc f,ush plpc wlh brass coupllng and plumbers Jolnts splndle stop cock of spprovd quallty wslght not less than 450grams 15mm P.V.C. connec-tlon plpc 46crn. long wlth brass coupllng at both ends and whlta/black plastlc solld stato lcal and lead of commander/cuckoo or other l.S.S. make wlth hlngce or scna rs etc. palntlng pipe and cistem otc. wlth 2 coats of approvod palnt ovor a coat of rcd oxlde prlmlng, all oomplate aB par spedflo.ton ind dlruo0on of E/t. |
| 53 | (i) With 'P'trap(b) 10 lit. low level PVC clstem |
| 54 | 17.4 Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 55 | 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushingcistern |
| 56 | 18.48 D.S.R. Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 57 | 1000 LTR CAPACITY |
| 58 | 18.18 D.S.R.Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 59 | 18.18.2 20 mm nominal bore |
| 60 | 18.74 D.S.R.Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 61 | 18.74.2 15 mm nominal bore with 45 cm length |
| 62 | 12.41 D.S.R.Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 63 | 12.41.2 110 mm diameter |
| 64 | 12.41.1 75 mm diameter |
| 65 | 12.42 D.S. R. Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 66 | 12.42.5.2 110 mm bend |
| 67 | 12.42.6.2 110 mm Shoe |
| 68 | 12.42.1.2 110 MM COUPLER |
| 69 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete |
| 70 | 110 mm |
| 71 | 12.43.1 75 mm |
| 72 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 73 | 17.7.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked |
| 74 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 75 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms |
| 76 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore |
| 77 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms |
| 78 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore |
| 79 | 18.50 D.S.R. Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 18.50.1 15 mm nominal bore |
| 80 | 18.65 D.S.R. 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. |
| 81 | D.S.R.18.75 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 18.75.1 15 mm nominal bore, weighing not less than 32 gms |
| 82 | D.S.R. 17.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 83 | 17.32.1 Circular shape 450 mm dia each 1248.60 17.32.2 Rectangular shape 453x357 mm |
| 84 | DSR 18.74 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 18.74.2 15 mm nominal bore with 45 cm length |
| 85 | DSR 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 86 | 17.28.2 Flexible pipe 17.28.2.1 32 mm dia |
| 87 | D.S.R. 18.37 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.37.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 88 | dsr 18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms |
| 89 | 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 90 | DSR 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 91 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 92 | Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 93 | 18.8/D.S.RProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 94 | 18.8.115 mm nominal outer dia Pipes |
| 95 | D.S.R 18.8.220 mm nominal outer dia Pipes |
| 96 | 17.4 Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizesrespectively with automatic flushing cistern with standard flush pipe andC.P. brass spreaders with brass unions and G.I clamps complete, includingpainting of fittings and brackets, cutting and making good the walls andfloors wherever required :17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing |
| 97 | D.S.R 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 98 | DSR 12.42.1.2Coupler 110 mm |
| 99 | DSR 12.42.2 Single pushfit Coupler |
| 100 | DSR 12.42.2.2110 mm |
| 101 | DSR 12.42.3 Single tee with door |
| 102 | DSR 12.42.3.2110 X 110 X 110 mm |
| 103 | DSR 12.42.4Single tee without door |
| 104 | DSR 12.42.4.2110 X 110 X 110 mm |
| 105 | DSR 12.42.5Bend 87.5° |
| 106 | DSR 12.42.5.2110 MM Bend |
| 107 | D.S.R. 12.42.6 SHOE - 110MM |
| 108 | DSR 12.42.6.2 110 MM Shoe |
| 109 | Electrical Installation Work |
| 110 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Finolex/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / C&S/ Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:Havell's/L&T/Legrand/Schneider/C&S (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard/Finolex (7) LED FTTING FIXTURE -: Havells/Bajaj/Crompton/C&S (Model/as per E/I ) (8) CEILING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha (Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Surya/Valmont/RR Ispat/Transrail (10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Mahindra |
| 111 | 1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 112 | 1.3.3Group C |
| 113 | 1.5Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 114 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 115 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 116 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 117 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 118 | 1.7.114x10.0 sq mm+2x6.0 sq mm earth wire |
| 119 | 1.13Point rewiring wiring in existing conduit,:-Rewiring for light point/fan point/exhaust fan point/caii bell point with.,5. sq.mm FR PVC Insuleted copper conductor single core cable in exiting PVC conduit, including dismentling as required. |
| 120 | 1.13.1Group A |
| 121 | 1.17TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required. |
| 122 | 1.21S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 123 | 1.21.120mm |
| 124 | 1.22S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required . |
| 125 | 1.22.175mm x 75mm x 50mm deep/ (4\\" x 4\\") |
| 126 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 127 | 1.24.15/6 amps, one way switch |
| 128 | 1.24.315/16 amps, one way switch |
| 129 | 1.24.45/6 amps, 3 pin socket outlet |
| 130 | 1.24.515/16 amp 6 pin socket outlet |
| 131 | 1.24.7TV socket socket outlet |
| 132 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 133 | M-1493Supply of Modular type AC starter switch for single phase 230 V /50 Hz of capacity 20/25 amp |
| 134 | 1.26S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc, as required. |
| 135 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 136 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 137 | 1.27.36 module(78mm x 205mm x 50mm) |
| 138 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required. |
| 139 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 140 | 1.34S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required. |
| 141 | 1.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 142 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 143 | 2.9.44 way (4+12),Double door, Horizontal type |
| 144 | 2.11S/F 'B' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 145 | 2.11.16/32 amps,single pole, \\"B\\" SERIES |
| 146 | 2.12S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 147 | 2.12.16/32 amps,single pole, \\"C\\" SERIES |
| 148 | 2.12.940 amps,TPN |
| 149 | 2.12.1050/63 amps, TPN |
| 150 | 2.18S/F 20 amps SPN MCB industrial socket outlet:-Supplying and fixing 20 amps, 240 volts,SPN industrial type, socket outlet, with 2 pole and and earth, metal enclosed plug top along with 20 amps 'c' series, SP MCCB, insheet steel enclosure,in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 151 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 152 | 3.6Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke) |
| 153 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 154 | 4.2P/F G.I. lightning conductor finial:-Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 155 | 4.4Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required. |
| 156 | 4.7P/F G.I. lightning conductor tape in horizontal run:-Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run) |
| 157 | 4.8P/F G.I lightning conductor tape in vertical run:-Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run) |
| 158 | 4.12P/F Testing joint for G.I. lighting conductor:-Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos.of G.I. bolts, nuts, chek nuts and spring washers etc complete as required. |
| 159 | 5.2Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 160 | Code no.Supply of PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 161 | M-33095 sq.mm. 3.5 core |
| 162 | 12.37 DSR Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 163 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 164 | 9.1.24 DSR 3½ X 95 sq. mm (45mm) |
| 165 | M - 775Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton |
| 166 | M - 777Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 167 | M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 168 | M 856Supplying and fixing of LED bulb 15/16 W of make bajaj/havells/crompton |
| 169 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 170 | 9.1.790 /100 W LED Street light of make bajaj/havells/crompton/C&S /Jaquar |
| 171 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 172 | 9.3.315/16 W LED Round Down Light of make bajaj/havells/crompton/C&S /Jaquar |
| 173 | 9.3.112'x2' LED Panel Light of make bajaj/havells/crompton/C&S /Jaquar |
| 174 | 9.3.1512 W COB based round LED light with multiple beam angle (36 Degree) of make bajaj/havells/crompton/C&S/Jaquar |
| 175 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 176 | 9.4.1 1200 mm (48\\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 177 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 178 | 9.5.110/12 W LED Batten of make bajaj/havells/crompton/C&S/ Jaquar |
| 179 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S/ Jaquar |
| 180 | M -918Supply of Category \\"A\\" 2.0 Tr capacity Hi-Wall Split AC Unit of BEE Star Rating 5 Star, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising along with original company make stand to fix outdoor unit by suitable size of fasteners, copper pipes up to any length, insulating materials, heavy duty PVC drain pipe. Each drain pipe should be connected with building rain water drain pipe (Make:- Hilty/Fischer) etc as required.Make: Hitachi / Mitsubishi / Daikin / Carrier/Voltas. |
| 181 | M - 1622Supply, fitting, fixing of wall mount 5 KVA capacity of Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connecting 3 Mtr 3 core 2.5 Sq. mm Flexible Copper cable ( indoor unit to Stabilizer) Make- V-Guard/Totaline/Sen & Pandit. |
| 182 | M -1625Out door stand for 2.0 Tr Split AC |
| 183 | M -1617Copper Tube of size 1/4\\" for Split AC unit 1/1.5/2/3 Tr Capacity including nitride rubber insulation |
| 184 | MAIN PANEL |
| 185 | Design manufacture, supply installation, testing and commissioning of WEATHER PROOF DOUBLE DOOR with rubber gasket 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel. |
| 186 | LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following: |
| 187 | (A)INCOMING |
| 188 | M - 3184 pole MCCB,25/100amp,10 KA with fixed thermal magnetic setting |
| 189 | M - 304100 amp. fout pole, onload change over switch in sheet enclosure with side handle oDeration |
| 190 | M-617 100 amp,415V, Heavy duty three phase with neutral Busbar Chamber |
| 191 | (B)OUTGOING |
| 192 | 2.12.640 amps ,DP |
| 193 | 2.12.940 amps,TPN |
| 194 | 2.12.1050/63 amps, TPN |
| 195 | (C)OTHER ACCESSOSRIES |
| 196 | M- 873 ADIGITAL VOLT METER 500V(3phase class 0.5) |
| 197 | M- 873 BDIGITAL A METER 500V(3phase class 0.5) |
| 198 | M- 445COPPER WIRE 1.5MM |
| 199 | M- 448COPPER WIRE 6MM |
| 200 | M- 449COPPER WIRE 10MM |
| 201 | M- 1455LED INDICATOR LAMP R/Y/B/G |
| 202 | M- 1452C.T COIL OF CT ratio 500/5 IS2705 part -3 |
| 203 | Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel.(50% of part -A +B+C ) |
| 204 | Add 18% GST |
| 205 | Add 1% Lebour Cess Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail