| 1 | Earthwork in excavation in foundation Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth a obtained to a distance Up to 50M including all lifts with leveling remming the foundation trenches removing roots of trees shurbsall complete as per approved design, building specification and direction of E/I |
| 2 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fullycompacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete asper building specification and direction of E/I (Mode of measurement compacted volume |
| 3 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 4 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 40 mm nominal size) |
| 6 | Providing designation 75A brick work in C.M (1:4 ) in foundation and plinth with approved quality of clean coarsesand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I(zone-iii): 3 graded stone aggregate 20 mm nominal size). |
| 7 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leadsand lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per buildingspecification and direction of E/I. |
| 9 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thickbase of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed withpigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality ofcarborandum stone including cost of curing, taxes and royalty all complete as per building specification anddirection of E/I. |
| 10 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m² |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:1.5:3 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 40 mm nominal size) |
| 12 | Supplying of fine aggregate/stone dust -do-do-all complete job. |
| 13 | Labour for compaction -do-do-all complete job. |
| 14 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 15 | Excavatin in road wayin soil by mechanical means including cutting and transporting the earth to site of embankment/dumping area widtha lead upto 1000m includding trimming bottom and side slops in accordance with requirements of lines grades and cross sections |
| 16 | Loosening, leveling and compacting original ground supporting embankment to facilitate placement of first layer of embankment , scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for emabakment construction. |
| 17 | Providing and laying of dry rubble flooring complete as per drawings and technical specifications clause 1303.3 |
| 18 | constructon of un rain forced , dowel jointed,plane cement concrete pavement over aprepared sub base with approved grade cement @400kg per Cum coarse and fine aggrtigate conforming to IS383 , maximaum size of coparse aggregate not exceeding 25mm , mix in batching and mixing plant as per approved mix design transported to site , layed with affixed form or slip form paver, spread , compacted and finished in acontinious operations including provision ofcontractin expaction,const. and longitudinal join , joint filler , sepratin membane, sealent primer, joint sealent, debonding strip , dowel bar , tie rod , admixtures approved curing compound, finishing to lines and grades as per drawing |
| 19 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fullycompacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M andlift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compactedvolume) |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:1.5:3 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 40 mm nominal size) |
| 21 | Sign board |
| 22 | S/F Busbar chamber: - Providing and Fixing 100 amps capacity busbar chamber with 4 strips of suitable size made of copper , heavy duty , complete with all accessories including connections , earthing the body etc. as required. |
| 23 | S/F rewireable double pole/ TP&N switch disconnector:- Providing and Fixing 63 amps capacity TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses , including drilling holes in metal board , making connections etc. as required. |
| 24 | Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 25 | 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire |
| 26 | 2 x 6 sq.mm + 1 x 6 sq.mm earth wire |
| 27 | S/F DB MCB isolator :- suppling and fixing 40 amps rating double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 28 | Supplying and fixing suitable sizes G.I/PVC box on surface or inrecess with phenolic laminated sheet cover in frong including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps paino type switch connection painting etc as required. |
| 29 | Supplying and fixing suitable size GI/PVC box of 121 mm x 173 mmx 48 mm /(6\\"x8\\") (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providng and fixing 6 pin 15/ amps paino type switch connection painting etc as required. |
| 30 | S/F 3 pin 5 amp celling rose on the existing junction box/wooden block including connection etc |
| 31 | S/F ceiling fan Regulator :-S upplying and fixing 3 pin 5 amp celling rose on the existing junction box/wooden block including connection etc |
| 32 | Supplying and fixing batten / angle holder including connection etc as req. |
| 33 | 15/16 Watt LED Bulb |
| 34 | Supply, installation, testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard for 230V 50 Hz, single phase supply etc. complete as required 1200mm(48'') Ceiling Fan |
| 35 | Carriage of materials :- Bricks |
| 36 | Stone chips |
| 37 | Cement |
| 38 | Stone boulder |
| 39 | ADD 18% GST |
| 40 | ADD 1% LABOUR CESS Please Enable Macros to View BoQ information |