|
| 1 | Construction of Adolescent awareness hall at Uthiyoor Anganawadi |
| 2 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | OD511298/2025-2026:Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size( Dry Masonry) for foundation and basement including all cost of materials, labour charges Complete for lining work |
| 4 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 7 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 8 | 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 9 | 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges |
| 10 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 11 | OD511306/2025-2026:Laterate masonry with neatly dressed laterate stone of size 35x20x20 cm or nearest size incement mortar 1:6 for superstructure above plinth level upto floor two level including all cost ofmaterials, labour charges etc. |
| 12 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 13 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 14 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 15 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 16 | 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 17 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 18 | OD458814/2025-2026:Supplying and installation of 12mm thick toughened glass with Stainless steel Patch Fitting/wall to glass connector of SS-316 Grade Steel of approved manufacturer The joints betweenglass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to befilled with non staining weather sealant, so as to make the entire system fully water proof& dust proof (Modified 25.8)Details of cost for 8.64 Sqm (opening Area 3.60x2.40) with Patch Fitting/wall to glassconnectorNote: The data for original item is providing toughened glass over very large area like frontportion of multi- storey buildings and the like. This may include several glass to glassjoints and need proper design and testing. This modified data is proposed to be used whenproviding toughened glass over small openings in buildings. The fittings required are modifiedaccordingly. |
| 19 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 20 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 21 | OD511322/2025-2026: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required. |
| 22 | 9.147C.2:Providing and fixing factory made uPVC white colour casement/ Casement cumfixed glazed door comprising of uPVC multi-chambered frame, sash and mullion(where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hingesand one handle on each side of panels along with zinc plated mild steel multipoint locking having transmission gear, cylinder with keeps and one side key,G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessarystainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded includingdrilling of holes for fixing hardware's and drainage of water etc. After fixingframe the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealent over backer rod of required size and of approvedquality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealent shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm) |
| 23 | 9.147A.5:Providing and fixing factory made uPVC white colour casement/casement cumfixed glazed windows comprising of uPVC multi-chambered frame, sash andmullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2mm thick galvanized mild steel section made from roll forming process of requiredlength (shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps andnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, mullion (if required) shall be also fusion weldedincluding drilling of holes for fixing hardware's and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealant over backer rod of required size and of approvedquality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). |
| 24 | 21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 25 | 9.153:Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. |
| 26 | OD458812/2025-2026:Providing and fixing 150mm wide ,semi circular PVC 4kg/cm2 rain water gutter pipe with ironbrackets with 25x5 mm size flat , screws and washersetc., including making necessaryconnections with rain water pipes etc. complete. Please Enable Macros to View BoQ information |