| 1 | CIVIL WORK (DEMOLITION & RECONSTRUCTION) |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Demolishing cement concrete or bricks or Granolithic floor including base concrete and including stacking of dismantled material as directed by engineer in charge within a distance of 50 m |
| 4 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In lime mortar |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 7 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transportincluding loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 8 | Dismantling of existing pavement (bituminous course) by mechanical means and disposal of dismantled material upto a lead of 1km, as per direction of engineer in charge. |
| 9 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 10 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 12 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 15 | Providing and laying in position ready mixed or site batcheddesign mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. All work upto plinth level |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 17 | Providing and laying in position ready mixed or site batcheddesign mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. All work above plinth level upto floor V level |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 19 | Providing and laying in position ready mixed or site batcheddesign mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from naturalsources, Portland Pozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions as per IS: 9103to accelerate / retard setting of concrete, to improve durabilityand workability without impairing strength; including pumpingof concrete to site of laying, curing, carriage for all leads; butexcluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.Note: Extra cement up to 10% of the minimum specified cementcontent in design mix shall be payable separately. In case thecement content in design mix is more than 1.10 times of thespecified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extracement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. All work above plinth level upto floor V level |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 21 | Providing and laying in position ready mixed or site batcheddesign mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from naturalsources, Portland Pozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions as per IS: 9103to accelerate / retard setting of concrete, to improve durabilityand workability without impairing strength; including pumpingof concrete to site of laying, curing, carriage for all leads; butexcluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.Note: Extra cement up to 10% of the minimum specified cementcontent in design mix shall be payable separately. In case thecement content in design mix is more than 1.10 times of thespecified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extracement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. All work above plinth level upto floor V level |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 24 | Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) |
| 25 | Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apieceof cloth lightly soaked in kerosene oil. |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : |
| 27 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (TMT Bars) Fe-500 |
| 29 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 30 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 31 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 32 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately)Sal wood |
| 33 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)Second Class teak wood35mm thick shutters |
| 34 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
| 35 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm |
| 36 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 37 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 38 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 39 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 40 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm |
| 41 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase. |
| 42 | Stone work (machine cut edges) for wall lining etc. (veneer work)upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - Exposed face machine cut and table rubbed with rough backing.. 30 mm thick |
| 43 | Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete.50 mm long |
| 44 | Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone |
| 45 | Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : Triangular or Square or rectangular pillars |
| 46 | Extra for stone work ashlar sunk or moulded in cornices. |
| 47 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 48 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: |
| 49 | Providing and fixing BRICK CLADDING on façade with adhesive and filing joints with grouting complete |
| 50 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M40 grade with minimum cement content of 390 kg/cum |
| 51 | Supplying and fixing of 3-4 mm stained glass in window with 6mm Toughnend. Stained glass sandwich in 6 mm toughned glass. Fixing all complte as per direction of EIC |
| 52 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 53 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick flat |
| 54 | INTERNAL ELECTRIICATION WORK |
| 55 | Wiring points for light with 1.5 sqmm. FRLSH PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm. FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.Light - 5two ways light - 4Fan - 1Exhaust fan - 1Plug with 1.5 sqmm. - 2Power plug with 20A /250 - 5 |
| 56 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 57 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 58 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 59 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 60 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 61 | Erection and testing of ceiling fan and regulator for room height upto 3.5 m including supply of 3 mm thick G.I. pipe 19 mm dia. Duly painted, complete in all respect. |
| 62 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 63 | Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 64 | Supply and fixing of LED Tube light with batten suitable for up to 1 x 22 watt LED tubelight fitting including tube on surface complete in all respect. (CAT-AAA) |
| 65 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 66 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 67 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 68 | S&F of 63 Amp. 4 Pole Isolator (CAT A) |
| 69 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve |
| 70 | S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve |
| 71 | S&F single pole MCB blanking plate.(CAT B) |
| 72 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 73 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 74 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 75 | 200 Amp. MCCB-1 No |
| 76 | 200 Amp. MCCB-2 Nos (CAT. B Pannel Cubicle Type) |
| 77 | Supply and fixing 400 Amp TPN sandwich aluminium bus bar trunking complete suitable for IP 54 protection with top end cover plate of 1.6 mm thik G.I. sheet with suitable arrangement for fixing etc complete in all respect. |
| 78 | Supply and fixing of Tape off box 125 Amp to 200 Amp TPN for sandwitch aluminium bus bar trunking complete in all respect. |
| 79 | 100 Amp. MCCB-2 Nos |
| 80 | 63 Amp. MCCB- 3 No. Extra 100 A MCCB |
| 81 | S&F of 400 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting andother material required for proper completion of the work as perdirection and satisfaction of Engineer in charge. |
| 82 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 83 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
| 84 | Supply and laying of aluminium conductor, PVC insulated armoured, served, sheeted cable 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the Engineer- In charge, complete in all respect. the armouring of the cable shall be properly connected with the earth condutor by clamps etc.95 sq. mm 3-1/2 core |
| 85 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheated, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer in Charge95 sq. mm 3-1/2 core |
| 86 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer in Charge.95 sq. mm |
| 87 | Supply of ceiling fans BEE 5 Star rated-1200mm sweep with fan motor of A.C permanent insulation,capacitor rating confirming BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltge 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. |
| 88 | EXTERNAL ELECTRIFICATION WORK |
| 89 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm 4 core |
| 90 | Supply and installation of ground-buried light fixture wall Washer-Linear In-Ground Luminaire Input Power: 24-30W LED compact and minimalist linear recess-mounted design for floor mount. With options of beam angle 8°/12°/40°/60°/40° x 11°. Brand names should be embossed on the luminaire luminairetopSSfram. Luminaires should be made of extruded aluminum alloy of high corrosion resistance (grade 6063), stainless steel top ring (grade 316), and noncorrosive stainless steel fasteners. Powder-coated aluminum profile installation housing for preparing the recess opening in the ground. Clear toughened glass. Protection class IP67. Mechanical resistance IK05. Available color temperatures are 2700K/3000K/4000K/5700K, and the color rendering index (CRI) is >80. SDCM-3 MacAdam. LED module with an expected service life of at least 60,000 operating hours. Constant A voltage non-integral power supply at 24 Vdc assures safety. Driver efficiency > 80%, surge protection 3 KV. Luminaire Dimension: 1025 mm length x 68 mm width x 83 mm height. CE&BIS Certified. In-house NABLA-accredited lab. All complete, including consumables required for installation. Samples should be submitted for approval from the architect. Engineer-in-charge. Make: K-Lite/Unilamp/Ligman etc. 1000 mm length |
| 91 | Supply and installation of ground-buried light fixture wall Washer-Linear In-Ground Luminaire Input Power: 24-30W LED compact and minimalist linear recess-mounted design for floor mount. With options of beam angle 8°/12°/40°/60°/40° x 11°. Brand names should be embossed on the luminaire luminairetopSSfram. Luminaires should be made of extruded aluminum alloy of high corrosion resistance (grade 6063), stainless steel top ring (grade 316), and noncorrosive stainless steel fasteners. Powder-coated aluminum profile installation housing for preparing the recess opening in the ground. Clear toughened glass. Protection class IP67. Mechanical resistance IK05. Available color temperatures are 2700K/3000K/4000K/5700K, and the color rendering index (CRI) is >80. SDCM-3 MacAdam. LED module with an expected service life of at least 60,000 operating hours. Constant A voltage non-integral power supply at 24 Vdc assures safety. Driver efficiency > 80%, surge protection 3 KV. Luminaire Dimension: 1025 mm length x 68 mm width x 83 mm height. CE&BIS Certified. In-house NABLA-accredited lab. All complete, including consumables required for installation. Samples should be submitted for approval from the architect. Engineer-in-charge. Make: K-Lite/Unilamp/Ligman etc. 600 mm length |
| 92 | Supply and installation of IP rating IP67 linear wall washer. Input power: 20 W, 2700 K, 3000 K, 4000 K, 24 VDC, CRI > 80 Mac Adam's step 3 dimension is not more than 1005 x 25 x 32 mm. Beam angle: 30/60° Electronic driver ON/OFF (external driver), high-grade aluminum & endcaps, and polyurethane encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered according to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), with a lifespan of the luminaire of >60,000 hours at 40°C.Operating ambient temperature range is from -25°C to +55°C. Driver efficiency > 85%, surge protection of 3 KV, and before the supply of material, CE & BIS Certified. All complete, including consumables required for installation. Samples should be submitted for approval from Architect/Engineer-in-Charge. Make: K-Lite/Unilamp/Neri |
| 93 | Supply & installation of 1.2m dia size 4-set clocks of clock tower. It should include Microprocessor based Quartz pulse circuit(with in-built battery backup for 12 hours), motor drive unit, Coupling set, Centralized gear. External dial will be made in 20mm solid square MS material frame, containing numerals & minute marks, painted with approved black oil paint. Internal dial parts, minute wheel, Hours wheel ,center wheel, cannon wheel, bushings etc. are in gun metal. Back ground of dial will be covered with polycarbonate which is bright milky white in day light and will brightly glow at night through even internal lighting with strip. Hands of the clock are in aluminum appropriate size & shape painted with black approved oil paint. Both Hands will be dynamically balanced. It will also include GPS based STRIKING SYSTEM consisting of MASTER CIRCUIT UNIT WITH INBUILT SCHEDULE TIMER, AMPLIFIER UNIT, SPEAKERS ( PA HORN UNITS) of make approved as per EIC. Design of dial to be as per instructions of EICOne year warranty on complete work including all spares ,circuit ,PCB & battery. Please Enable Macros to View BoQ information |