| 1 | S/I/T/C of 100MT Fully Electronic Weighbridge Up to Digitizer specification as below:- A- Platform Size- 15 M X 3 M B- Accuracy- 10 KG C- Load Cell Specification 1. Capacity - 30MT 2. Type - Double Ended Shear Beam Type 3. No. of Load Cells - 8 Nos 4. Cable Six Core 5. Environmental Ceiling - IP 68 6. Overload Capacity 150% RL 7. Ultimate Load 300% RL8. Temp 10@C to +60C Fiber accessories will be provided to safeguard the Load Cells & to protect Load Cells against stray electric currents, lightning induced faults. Weigh bridge is to be structured with strut Assembly. It should offer the Weighbridge platform universal motion thus minimizing the impact load on the load cells caused by braking of the vehicles on the platform. D- Junction Box- Junction Box to be equipped with Surge Protection to protect it from lightning & stray currents. Environmental Ceiling IP 65 E- Digital Weight Terminal: Digital Indicator should be of microprocessor based with Six digit bright large having LED Display. It should have self-diagnostic weighing terminal. The system should be programmable on site. This should be enabled to optimize to meet all the fundamental requirements of modern-day Electronic weighbridge. The high precision tracking excitation source should have a capability to source more than 250ma, adequate for 8 No. 350 ohm load cells. The analog fronted should be built around a low noise differential amplifier with extremely low gain and offset drift. It should have the facility to be interfaced with PC. F- Platform Structure Platform Structure frame should be made robust in construction, made of adequate plate thickness, fitted with heavy duty joists, adequately reinforced with transverse beams and suitable non-slip top deck. The entire steel framework should be mounted on load cells. Easily movable and reloadable modern MS beams based heavy duty rugged design. Plate and girder make should be of reputed make like SAIL/Jindal or equivalent Weigh bridge structure material to be of IS:2062 material and plate should have anti-skid characteristics. Anti-corrosion painting should be done to prevent from corrosion.STRCUTURE WEIGHT: 10 MT PLATE THICKNESS: 12 MM(Minimum) G- Civil Foundation Civil Foundation work for weigh bridge will be constructed by agency as the civil foundation work costing is already included in the sanctioned rate. Requisite drawing, design should be provided to department by concerned agency. Agency to carry out all the necessary civil work required for weigh bridge foundation including excavation of foundation, earth work, ramps on both sides of weigh bridge, columns for load cell mounting and other CC, RCC and TMT related work as per direction of Engineer-in-charge complete in all respects.a. Weighbridge Foundation:i. Clearing work site.ii. Dismantling the existing RCC floor present at the site of installation if required.iii. Earth work excavation for erection of 08 Nos of columns.iv. Filling the excavated area for the columns with Medium Sand and laying PCC before erecting the columns.v. Supplying and providing all necessary TMT for weighbridge column foundation and ramp.vi. Doing the necessary shuttering works and laying M25 Grade RCC for all the columns and both the ramps.vii. Supplying and filling of WMM. viii. Plastering work for all foundation using high quality ISI Marked PPC Cement. ix Disposal of the excavated earth and rubbish and clearing the site thoroughly for complete removal of all the unwanted material x. Necessary barricading should be done at the location of the site throughout the period of works and all the labours should wear necessary safety equipmentH- Weigh bridge software Easy to use interface. Variety of reports considering all types of transactions carried out on the software available. Vehicle-wise / Driver-wise / Product-wise / Commodity-wise / Date-wise / Supplier-wise, etc. reports available. Summary Report containing complete details of all the transactions done during a particular period. Highly scalable with increase in weighing requirements. Role-based access control mechanism to ensure utmost level of security. Transaction Management with categorization like Active Transaction, Completed Transaction & Void Transaction. Versatility to manage products, measure units (Kgs, Tons, Lbs) Facility to integrate Highly adaptable state-of-the-art UI that can be easily adaptable to different platforms. I- Erection & Fitting: Agency has to arrange shall arrange for the fitting of the machine at site. The work includes S/I/T/C of weigh bridge. J- Stamping: Agency will carry out stamping work for the weigh bridge. Stamping Expenses is to be borne by agency itself. K- Warranty: This work include one year warranty against any manufacturing or inherent defect which will be replaced or repaired free of any charges. L- Other Items: i5 PC (with all accessories) & Dot matrix type Printer to withstand rough environment and U.P.S. including battery with upto 8 hours backup. MANDI PARISHAD |
| 2 | Operational cost of 100MT capacity pitless electronic weigh bridge for 24 hours operation As per Latest Labour rate |
| 3 | Comprehensive maintenance contract and operation of 100MT capacity pitless electronic weigh bridge for 24 hours operation including stationary Mandi Parishad |
| 4 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder with modular type switch etc complete in all respects as directed, including matching color wash. 138 C + 187 A |
| 5 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose with modular type switch etc complete in all respects as directed, including matching color wash. 140C + 187A |
| 6 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire with modular type switch & socket etc., complete in all respects as directed, including matching color wash. 141 C + 187 C |
| 7 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve6 - 32 amps.Cat. A 1002 A |
| 8 | Supply and fixing of 6 Amp to 32 Amp DPMCB(10KA)C Curve6 - 32 amps.Cat. A 1009 A |
| 9 | S/F of 8 way SPNDB without MCB 1024 A |
| 10 | Supply and burying safe earthing Electorde T-19 (Hot Dip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25, terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Gavanized up to 100 mircon filled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaning capacity along with 30 cm squre C.I. frame with hinged cover & masonry housing (from electode terminal to switch board , cost of 25 x 3 G.I. strip will be extra) Make: As approved in U.P.P.W.D. & C.P.R.I. Certified 725A |
| 11 | Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 721 |
| 12 | Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. 1149 |
| 13 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work. 1139A |
| 14 | Supply and fixing of water tight oblong 10watt LED bulkhead luminaire with driver set confirming to IP 65 as above protection complete in all respect. 23.11 |
| 15 | Supply & wiring of sub mains with two number 2 x 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable concieled in wall & laid in slab 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. 216 C |
| 16 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. on surface6 Sqmm X 2 core 20c.1.1 |
| 17 | S/F of Ceiling Fan 1200 mm 1501 I |
| 18 | S/F of Fan Regulator 1203 C |
| 19 | S/F of 1X22 Watt LED Tubelight fitting 23.08 Please Enable Macros to View BoQ information |