| 1 | Removing old scales , blister etc. of interior surface, cilling, by scrapig etc & preparing smooth & even surface with rendering or cement morter (1:2) to make the surface suitable for reciving distemper. |
| 2 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothening of surface. Two coats |
| 3 | (A) Painting with best quality synthetic enamel paintof approved make and brand including smoothening of surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: (a) On timber or plastered surface.With super gloss (high-gloss)iii) One coat (with any shade except white) |
| 4 | (b) On steel or other metal surface.With super gloss (high-gloss)iii) One coat (with any shade except white) |
| 5 | Supplying profiels of require section made of alluminium alloy extrusions conferming to IS : 732-1983 & IS : 1285-1975, Anodised matfinised confrming to IS : 1868-1983 for febrication of composite door , sliding & casement window, partition formed basic sections of any ISI embossed / certified make & brand as per direction of EIC A) IN 10-12 micron anodysing film, in Nutural white 3-track sliding windowi)Bottom frame |
| 6 | ii)Top & side frame |
| 7 | 2-track sliding windowi)Bottom frame |
| 8 | ii)Top & side frame |
| 9 | B) shutter for all track sliding windowi)Bottom & Top member |
| 10 | ii) Style side member |
| 11 | iii) Interlock member |
| 12 | Moveble Door shutterDoor Frame (Top & sides)Door Frame (Top & sides) |
| 13 | Shutter(a) Top Rail |
| 14 | (b)Bottom Rail |
| 15 | ( c ) Lock Rail |
| 16 | (d) Door Vertical |
| 17 | (e) Glazing Clip |
| 18 | Labour charges for febrication & installation of composite door, window, partition made from annodized extruded alloy aluminium section for glazed aluminium sliding windows made of extruded alloy aluminium section , febrication , including cutting to proper sape & size , drilling & aligning of window shutter frame fitted with built locking arrangement , sliding roller & other necessary fitting , fixture , adhesives & joiner ies along with extraded neoprine or EPDM gasketing in between window frame & mesonery work as well as between glass & shutter frame for fixing glass & polysuklphide sealant & in between shutter & window frame where necessary including cutting to reqsize and fixing glass asper drawing specification and direction of EIC.3/4 track sliding window |
| 19 | 2 track sliding window |
| 20 | Labour charges for febrication & installation of Partly glazed partly panelled or fully glazed single leaf aluminium swing door made of extruded alloy aluminium section , febrication , including cutting to proper sape & size , drilling & aligning of window shutter frame fitted with built locking arrangement , sliding roller & other necessary fitting , fixture , adhesives & joiner ies along with extraded neoprine or EPDM gasketing in between window frame & mesonery work as well as between glass & shutter frame for fixing glass & polysuklphide sealant & in between shutter & window frame where necessary including cutting to reqsize and fixing glass asper drawing specification and direction of EIC. |
| 21 | Supplying PVC roller for slaiding window asper direction of EIC. |
| 22 | Supplying Maruti lock 100mm |
| 23 | Supplying EPDM gusket of approved make and brand as per approved of EIC.(a) U sape EPDM gusket for frame |
| 24 | (b)weather gasket / wool pile for door vertical. |
| 25 | Supplying bouble free float glass of approved make and brand conforming to IS : 2835-1987(i) 4 mm thick coloured /tinted / smoke glass(i) 4 mm thick coloured /tinted / smoke glass |
| 26 | (ii) 6mm thick coloured / tinted / smoke glass. |
| 27 | (A) Supplying Aluminium casted body hydraulic door closer as per I.S.I. |
| 28 | Supplying 4 lever mortice lock or any approved make and brand as per |
| 29 | Providingandfixing exteriorqualityAluminiumCompositePanel(ACP)wallcladdingonexistingAl./MSframeworkwithGIbrackets,ACPfixedontheexistingframeworkbyfoldingtheedgesofACPpanel(EngravingtherearsurfaceofACPsheet)withCPangles,cleatsandstrainlessSteelscrewsforminggrovesattheperipheryofACPpanel.Suchgroovesfilledwith foamand silicon sealant etc. complete with all materials (butincluding thecost of siliconsealant), labour, scaffoldingandall otherincidental charges complete in all respect as per specification anddirectionofEngineer-in-charge. (Modeofpayment isonfinishedsurfacearea of ACP) |
| 30 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed withcadmium plated screws: 125 x 63 x 4.0mm. |
| 31 | Anodised aluminium grip handle with base plate of approved quality fitted and(a) With base plate.300mm grip x 20mm dia rod x 50mm plate x 3.2mm thick. |
| 32 | French Polish to wood work including preparing surface (ordinary gloss)(a) on Old French polished surface including complete removal of the old polish(a) on Old French polished surface including complete removal of the old polish |
| 33 | Dismantlingartificial stoneflooringupto50mm.thickbycarefullychisellingwithoutdamagingthebaseand removingrubbishasdirectedwithinalead of 75 m. |
| 34 | Supplying, fitting&fixing1st qualityCeramic tiles inwallsand floors tomatchwith theexistingwork&4nos. of keystones (10mm) fixedwitharalditeat thebackof each tile&finishing the jointswithwhite cementmixedwithcolouringoxide if required to match the colour of tiles includingrougheningof concrete surface, if necessaryorby syntheticadhesive & grout materials etc.(A) In First FloorithSandCementMortar (1:4) 20mmthick&2mmthickcement slurry at back side of tiles using [email protected]/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.b) Area of each tile above 0.09 Sq.m(ii) Other than Coloured decorative including white |
| 35 | MS or WI Ornamental grill gate of approved design joints continuously welded with MS, WI Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs . (i) grill weighing above 10 kg/sq m and upto 16 kg/sq m and hanging with locking arrangement including all labour & material cost. |
| 36 | Supplying, fitting , fixing decorative lamination conforming ton IS: 2046: 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on particle MDF/ Ply Boards wth recommended /approved adhessivewith paper clipping the sides for better attachment as per direction of Engineer-in Charge. The rates includes the cost of labour, adhessive and all incidental charges thereof. (i) Thickness of laminate 1.5 m |
| 37 | providing and fixing of factory made uPVC sliding Door (white colour) complete.a)2truck 2sash door frame of size 67x54mm and such of size 85x47mm both having wall thickness of 2.3+-0.2mma)2truck 2sash door frame of size 67x54mm and such of size 85x47mm both having wall thickness of 2.3+-0.2mm |
| 38 | Out side Colour wash,Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m including stacking of steel bars. (a) In ground floor. |
| 39 | Stripping off worn out plaster and raking out joints of walls, ceiling etc. up to any height and in any floor including removing rubbish within a lead of 75 m as directed. |
| 40 | Scraping of moss blister etc throughly from exterior surface of wall necessiating the use of scraper wire brass etc. |
| 41 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners, as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor (Excluding cost of chipping over concrete surface) (i) With 1:6 cement mortar ( C ) 15 mm thick plaster |
| 42 | (iI) With 1:4 cement mortar ( c) 10 mm thick plaster |
| 43 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly complete as per manufacturer's specification and as per direction of the EIC. (In ground floor). (a) One coat |
| 44 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of the Engineer-in-Charge to be applied over acrylic primer as required. The rates includes cost of materials, labour, scaffolding and all incidental charges but excluding the cost of primer. (In ground floor, Two coats)(a) Premium 100% Acrylic Emulsion |
| 45 | Priming one coat on timber or plaster surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 46 | (A) Painting with best quality synthetic enamel paintof approved make and brand including smoothening of surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: (a) On timber or plastered surface.With super gloss (high-gloss)iii) One coat (with any shade except white) |
| 47 | Priming one coat on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 48 | (b) Painting with best quality synthetic enamel paintof approved make and brand including smoothening of surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface.With super gloss (high-gloss)iii) One coat (with any shade except white) |
| 49 | Ordinary Cement Concrete (1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, as per relevent IS codes. With Pakur variety chips. |
| 50 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 metre using approved stout props and thick hard wood planks .. |
| 51 | Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) ---- complete as per drawing and direction including cost of wire upto 1st floor level. Other than SAIL/TATA/RINL) |
| 52 | Supplying, fitting & fixing 4 mm thick Indian sheet glass set in putty and fitted and fixed with nails and putty complete |
| 53 | Supply and Installation Split type room air conditioning machine of following tonnage capacity 3 star rating fitted with rotary crompresser and cooling capacity min. 6000kcal/Hr, minimum discharge air flow 800cum mtr, 800EER (W/W) 2.7-2.89(Rate are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfection of the EIC.i)1.5 ton (Make: Voltas) 3star non -inverter type |
| 54 | Add GST @ 18% on Sl No. 1 to 52 |
| 55 | Add CESS @ 1% Please Enable Macros to View BoQ information |