Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Yard /Compound Lighting:- Supplying and erection of Cast Iron steel tubular pole of 3000mm length with Double bracket made out of cast Iron with Galvanised Steel Tube, pole finish with polyster with base plate 220mm x 220mm. The poles to be primer coated and painted with polyster/ black paint/gray. Brackets are made out of Milld steel & aluminium and suitable for Heavy duty ornamental poles.The pole provided with a service window at bottom profile comprising 4-way 25 Amp connector terminal and a MCB etc. The pole to be mounted on a 1:2:4 cement concrete base (pedestal) of 450mm X 450mm and 450mm L-Type foundation bolts 4mm X 16 mm dia with nuts, templates and all complete as per approved drawing Foundation RCC 1:2:4 shall be of size 450 X 450mm and depth 900mm c/c as per approved drawing. The foundation shall extend above sorrounding ground/driveway level for 200mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing, complete in all respects as required Make:-Twinkle, Bajaj, K-lite or any other make approved by Engineer-in-charge. |
| 2 | Cast Iron steel tubular pole( Double Bracket), Overall length 3 meter. |
| 3 | Supplying and erection of Cast Iron steel tubular pole of 3000mm length with Single bracket made out of cast Iron with Galvanised Steel Tube pole finish with polyster with base plate 220x220. The poles to be primer coated and painted with polyster/ black paint/gray. Brackets are made out of Milld steel & aluminium and suitable for Heavy duty ornamental poles.The pole provided with a service window at bottom profile comprising 4-way 25 Amp connector terminal and a MCB etc. The pole to be mounted on a 1:2:4 cement concrete base (pedestal) of 450X450 mm and 450 mm L-Type foundation bolts 4x16 mm dia. with nuts, templates and all complete as per approved drawing.Foundation RCC 1:2:4 shall be of size 450x450mm and depth 900 mm c/c as per approved drawing.The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing, complete in all respects as required Make:-Twinkle, Bajaj, K-lite or any other make approved by Engineer-in-charge. |
| 4 | Cast Iron steel tubular pole( Single Bracket), Overall length 3.00 meter. |
| 5 | Supplying and fixing of LED decorative fixture 40W,made of cast aluminium with, power LED's are directly mounted on inbuilt heat sinks. A UV stabalized PC/PMMA diffuser is provided for glare free lighting with high visual comfort and painted with harvest green complete with all accessories including making connections, testing etc. as required Make:-Make:-Twinkle, Bajaj, K-lite or any other make approved by Engineer-in-charge. |
| 6 | Providing and laying of one number additional PVC insulated and PVC sheathed armoured / XLPE power cable of 1.10 KV grade of following size direct in cable tray including accessories clamping. |
| 7 | Armoured cable 10.00 sq. mm (twin core). |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm. |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 11 | 6 way, Double door. |
| 12 | Supplying and fixing following rating, followings poles 10ka 240/ 415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | 40A DP. |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/ 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Single pole. |
| 16 | Providing Lifts:- Supply, Installation, Testing and Commissioning of simplex car, Passenger elevators with following specifications and features:- |
| 17 | Speed-MPS: 1.0 to 1.25 MPS. |
| 18 | Power Supply: 400/415 Volts 3 phase 50 Hertz. AC. |
| 19 | Control: AC variable voltage variable frequency (close loop) Microprocessor based VVVF. |
| 20 | Operation: Full /simplex, collective with/ without attendant. |
| 21 | Car Group: One car (Simplex). |
| 22 | Machine: Gearless machine to be placed in the hoistway (MRL). |
| 23 | Traction Media: Flat Coated Steel Belt. |
| 24 | Car Enclosure: Rear Mid Panels; Rear Side Panels; Side Panels; Front Panels- Hairline Finish/ honeycomb or at par as per standard of OEM. |
| 25 | Flooring: Vinyl Tiles/Granite/or at par as per standard of OEM. |
| 26 | False Ceiling: CD-41/Hairline Finish/or at par as per standard of OEM. |
| 27 | Car Panels: Stainless steel Hairline Finish/or at par as per standard of OEM. |
| 28 | Car Entrance: Central opening (CO) doors in Stainless steel Hairline Finish or at par as per standard of OEM. 800mm W X 2000mm H. |
| 29 | Door Operation: DC Door Operator. |
| 30 | COP: Gien Buttons in Stainless Steel #4(Hairline)/or at par as per standard of OEM. |
| 31 | HALL FIXTURES:O2000 Pan Type Fixture/or at par as per standard of OEM. |
| 32 | HALL BUTTON ARRANGEMENT: LCD Monochrome Type/Hall Button with HPI. |
| 33 | Handrails On Three Sides: Stainless Steel Mirror/hairline Finish. |
| 34 | Signals (Design): Dot matrix (LED) Scrolling Display/or at par as per standard of OEM. |
| 35 | Feature Details: Anti-nuisance Car call protection, Independent Service (simplex), Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Belt Inspection Drive, Auto Fan Cut Off, Audible Car Call Button, Door Open/Close Button, Manual Rescue Operation, Belt Call Protection, Seismic sensor, Automatic Rescue operation, Voice Synthesizer, Intercom. All signal fixtures in stainless steel faceplates. |
| 36 | The prices of complete job as per the specifications above shall be inclusive of steel Items, minor building work, Scaffolding etc. All sundry fittings, assemblies, accessories, hardware items, foundation bolts, terminal lugs for electrical connections as required, and items which are useful and necessary for proper assembly and efficient working of various components shall be deemed to have been included in this job, whether such items are specifically mentioned in the tender documents or not. |
| 37 | Load –Kgs: 544 Kgs (8 Passenger) Elevator: |
| 38 | Travel (Max.): 19.00 Mts approx. |
| 39 | Stops & Openings: 04 Stops; G,1,2,3,4 With reverse opening at (Ground Floor). |
| 40 | Car Size: 1250 mm W x 1150 mm D x 2300 mm High/or at par as per standard of OEM. |
| 41 | Hoistway Available/Required: 1895mm x 1500 mm (or at par as per standard of OEM). |
| 42 | Total price for 8-passenger lift with above specifications complete in all respects: Make: TK elevators, Otis elevator, Orbis Elevator or as approved by Engineer-in-charge. |
| 43 | Fire Fighting and fire alarm:- Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel should be compatable for CPU redundancy with following Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) Loop length up to 1.50km, LCD touch screen display with bright colors to indicate alarms and events, status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hours back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to prinhtout logand facility seamless integration with analog/ digital voice evacuation system ,Public Address System and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Make:- Siemens/ Honneywell (Notifire) / Bosch, Schrack, Johnson control or as approved by Engineer in charge. |
| 44 | 1 Loop Panel. |
| 45 | Supply, Installation, Testing and Commissioning of addressable smoke detector including mounting base with LED etc. complete as required with inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be EN54-VDS/UL-FM certification complete as required. Make:-Siemens/ Honneywell (Notifire) / Bosch, Schrack, Johnson control or as approved by Engineer in charge. |
| 46 | Supply, Installation, Testing and Commissioning of Loop Powered Sounder with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.10 dB(A), should be programmed from the panel complete as required. The equipment shall be EN54/Vds/UL certified Make: Bosch, Notifier, Schrack, Johnson control or as approved by Engineer-in-charge. |
| 47 | Supply of Addressable Monitor Module with Inbuilt isolators for flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts or Line monitoring resistors.The equipment shall be EN54/ Vds/ UL certified Make:- Siemens/ Honneywell (Notifire) / Bosch, Schrack, Johnson control or as approved by Engineer in charge. |
| 48 | Supply, Installation, Testing and Commissioning of Addessable Manual break glass unit as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. The equipment shall be EN54/ Vds/ UL certified complete as required. Make:- Siemens/ Honneywell (Notifire) / Bosch, Schrack, Johnson control or as approved by Engineer in charge. |
| 49 | Supply, Installation, Testing and Commissioning of Addressable relay module with inbuilt isolators as per NFPA 72 style 7 wiring requirements. Relay control module shall be used for emergency control functions including shutting down fire dampers in AHU's, tripping of AHU's, Frsh air fans, Ventilation fans, tripping of access control door etc. The equipment shall be EN54/ Vds/ UL certified Make:- Siemens/ Honneywell (Notifire) / Bosch, Schrack, Johnson control or as approved by Engineer in charge. |
| 50 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 51 | 25mm dia. |
| 52 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 53 | 2 x 1.5 sq. mm. |
| 54 | Providing,laying, testing and commissioning, \\"C\\" class heavy duty MS Pipe conforming to IS 3589/IS 1239 including welding, fittings, flangers, tapers, nuts & bolts, gaskets etc. and fixing the pipe on wall/ ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:- Make :- Jindal/ Tata/ Sail. |
| 55 | 100 mm dia. |
| 56 | 80/75 mm dia. |
| 57 | 50mm dia. |
| 58 | 40/38mm dia. |
| 59 | 25mm dia. |
| 60 | Supplying and fixing single headed internal hydrant valve with instantaneous gunmetal / Stainless steel coupling of 63mm dia with cast iron whell ISI marked conforming to IS5290(Type-A) with blank Gunmetal /Stainless Steel cap and chain as required Make:- Lifeguard, Minimax, Newage, Ceasefire, Atasee or as approved by Engineer-in-charge. |
| 61 | Single Headed stainless steel. |
| 62 | Providing installing and commissioning of first aid hose reel with MS construction spray painted in post office red conforming to IS: 884 with following specifications as required: 20mm dia internal dia thermoplastic (Textile reinforced ) type -2 as per IS: 12585. 20mm nominal internal dia gun metal globe valve, nozzle drum and brackets for fixing the equipment on wall.Connection from riser with 25mm dia stop gun metal valve & M.S Pipe and socket Make:- Lifeguard, Minimax, Newage, Ceasefire, Atasee or as approved by Engineer-in-charge. |
| 63 | Supplying and fixing 63mm dia, 15metre long reinforced rubber lined (RRL) hose pipe with 63mm dia Male type2 and female SS couplings duly binded with G I wire, rivets etc. conforming to IS 636 (type-A) as required Make:- Lifeguard, Minimax, Newage, Ceasefire, Atasee or as approved by Engineer-in-charge. |
| 64 | Supplying and fixing 63mm dia stainless steel (Grade 304) short branch pipe with 20mm (nominal internal diameter) size SS nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required Make:- Lifeguard, Minimax, Newage, Ceasefire, Atasee or as approved by Engineer-in-charge. |
| 65 | Providing & fixing weather proof standard hose cabinet (30\\"x 24'' x 10\\") outdoor type, made out of sheet having glazed door with 6mm thick clear glass including necessary locking arrangement with allen key, powder coating with Post Office Red paint and for housing 2No. RRL hose pipe, 1No. branch pipe including grounting and suitable inscripting the words \\"Hose Cabinet\\" on the Box complete as required Make:- Lifeguard, Minimax, Newage, Ceasefire, Atasee or as approved by Engineer-in-charge. |
| 66 | Providing and Fixing MS Air vessel/ cushion tank on top of fire fighting system riser fabricated from 6mm thick MS Plate, 250mm in diameter and 1.20 metre in height with dished ends with air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure guage with gun metal stop cock complete in all respects as required Make:- Lifeguard, Minimax, Newage, Ceasefire, Atasee or as approved by Engineer-in-charge. |
| 67 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN1.6 with non rising spindle, bronzr/ gunmetal seat ISI Marked complete with nuts,bolts, washers and gaskets and conforming to IS:780 of following sizes as required Make:- Kirloskar, Zoloto, Sant, Leader, Grundfos or as approved by Engineer-in-charge. |
| 68 | 100 mm dia. |
| 69 | 80mm dia. |
| 70 | Providing, fixing, testing and commissioning of pendant type 15mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessories Make:- Minimax, Newage, Ceasefire, Lifeguard, Atasee or as approved by Engineer-in-charge. |
| 71 | Supply and fixing of GI Chilly clamps for MS pipes of various sizes including stud fastner and rods to fix the clamps complete in all respects as required with best satisfaction of Engineer-in-charge. |
| 72 | 75mm. |
| 73 | 50mm. |
| 74 | 32mm. |
| 75 | Providing & fixing 4kg, ABC MAP-90% powder type fire extinguishers, manufactured and marked as per IS marked (IS:15683), hose shall made of EPDM rubber, CE Marked valve, Suitable first aid aplliance for fighting fires in class A,B & C fire that is wood, textile, flammable liquids & gases Make:- Minimax, Ceasefire, Safex, Atasee, Lifegaurd or its equivalent as approved by Engineer-in Charge. |
| 76 | Providing & Fixing portable fire extinguisher,carbon dioxide type manufactured as per IS:15683, having flat base, valve, discharge hose of not less than 10mm dia,1metre long, initial fill with CO2 gas confirming to IS: 15222, filled to a filling ratio not more than 667 with wall suspension bracket Make:- Minimax, Ceasefire, Safex, Atasee, Lifegaurd or its equivalent as approved by Engineer-in Charge. |
| 77 | Providing & Fixing water CO2 9ltrs type fire extinguisher consisting of 30cm long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 15683 finished externally with red enamel paint and fixed to wall brackets Make:- Minimax, Ceasefire, Safex, Atasee, Lifegaurd or its equivalent as approved by Engineer-in Charge. |
| 78 | Providing VRV System:- Supply, Installation, Testing and Commissioning of VRV/ VRF Modular Type outdoor units, equipped with Highly Efficient Scroll, all inverter compressor(s), special heat exchanger, Y- branch as required, outdoor unit support, auto check function for connection error, auto address setting, refrigerant temperature control and capacity as mentioned below. VRV/VRF System shall be suitable for working on 49°C ambient temperature, refrigerant R 410A complete in all respect. The manufacturer of ODU and compressor shall be same i.e the make of compressor shall be identicle of the ODU Make:- O General, Mitsubishi Electric, Daikin, Carrier or as approved by Engineer-in-charge. |
| 79 | VRV Outdoor Unit 36 HP. |
| 80 | Supply, Installation, testing and commissioning of Hi-wall Type Indoor units equipped with, pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections, variable evaporative temperature control etc. of various capacities as per specifications and drawings complete in all respects as required Make:- O General, Mitsubishi Electric, Daikin, Carrier or as approved by Engineer-in-charge. |
| 81 | Wall Mounted 0.83 TR Indoor Unit. |
| 82 | Wall Mounted 1.32 TR Indoor Unit. |
| 83 | Wall Mounted 1.65 TR Indoor Unit. |
| 84 | Wall Mounted 2.08 TR Indoor Unit. |
| 85 | Supply, Installation, testing and commissioning of cassette type indoor units equipped withl, pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain pump, insulation, pipe connections, variable evaporative temperature control etc. of various capacities as per specifications and drawings, All indoor Units should have force shut option to connect with fire alarm or key card adaptor, so that the unit automatically stops in case of fire or key card removal complete in all respects as required Make:- O General, Mitsubishi Electric, Daikin, Carrier or as approved by Engineer-in-charge. |
| 86 | Cassette type 1.65TR Indoor Unit. |
| 87 | Cassette type 2.08TR Indoor Unit. |
| 88 | Cassette type 2.65 TR Indoor Unit. |
| 89 | Cassette type 3.31 TR Indoor Unit. |
| 90 | Cassette type 4.13 TR Indoor Unit. |
| 91 | Supply, installation, testing and commissioning of wired control remote suitable for Variable refrigerant flow with Large liquid crystal screen display, Operation start/stop can be programmed using timer for periods up to 72 hours. Thermostat sensor provides room temperature control for optimum comfort. Microcomputer monitors room temperature and preset temperature, automatically selecting cool/ heat operation use any indoor remote controller to select cool, heat, or fan mode without using the main cool/heat selection switch. Continuous monitoring of 40 possible malfunctions with self-diagnosing capability, complete in all repects as required Make:- O General, Mitsubishi Electric, Daikin, Carrier or as approved by Engineer-in-charge. |
| 92 | Supply, installation, testing and commissioning of R410A Refrigerant for variable refrigerant flow system complete in all respects with vaccum and pressure testing of copper piping and filling of refrigerant in the copper pipes complete with all necessary connections Make:- O General, Mitsubishi Electric, Daikin, Carrier or as approved by Engineer-in-charge. |
| 93 | Providing refrigeration joints for indoor units of variable refrigerant flow system, including complete vaccum and pressure testing of copper piping and filling of refrigerant and complete joint of copper piping and the unit, complete in all respects as required Make:- O General, Mitsubishi Electric, Daikin, Carrier or as approved by Engineer-in-charge. |
| 94 | Supplying and fixing of copper piping for flow of refrigerant (R410) or its equivalent between indoor and outdoor unit of VRV system with closed cell elastometric nitrile rubber tubular insulation complete in all respects with laying and connection of piping as required Make:- Mexflow, Airflow, Mandev or as approved by Engineer-in-charge. |
| 95 | 41.30mm dia with 19mm insulation. |
| 96 | 34.90mm dia with 19 mm insulation. |
| 97 | 28.60mm dia with 19mm insulation. |
| 98 | 25.40mm dia with 19 mm insulation. |
| 99 | 22.20mm dia with 19mm insulation. |
| 100 | 19.10mm dia with 13mm insulation |
| 101 | 15.80mm dia with 13mm insulation. |
| 102 | 12.70mm dia with 13mm insulation. |
| 103 | 9.50mm dia with 13mm insulation. |
| 104 | 6.40mm dia with 13mm insulation. |
| 105 | Providing and fixing PVC conduit of following sizes with 9mm thick XLPE closed cell nitrile insulations complete in all respects as required with best satisfaction of Engineer-in-charge. |
| 106 | 25mm dia with 9mm insulation. |
| 107 | 32mm dia with 9mm insulation. |
| 108 | Supplying and fixing of control cum transmission copper wiring of 2 core with 1.5 sq.mm dia in PVC conduits for connection between indoor and outdoor units and corded remote units complete in all respects as required with best satisfaction of Engineer-in-charge. |
| 109 | Providing Modular UPS System:- Supply, Installation, Testing and Commissioning of min 60KVA/ 60KW or Higher rating (Expandable up to 100KVA/KW) True OnLine, Energy Efficient, configuration double conversion UPS with following description and specifications:- |
| 110 | General Specifications |
| 111 | Topology True Online Double Conversion VFI (Voltage and Frequency Independent accordingly with classification mentioned in the EN- IEC62040-3 Standard). |
| 112 | Architecture of the UPS The Design of the UPS shall be Modular Type with Decentralized parallel Architecture and the Power Module shall be in the range from 5KW to max up to 20KVA Range to achieve high redundancy. UPS should operate in N+1 mode for spare /redundancy purpose. |
| 113 | Rectifier Fully controlled, IGBT based. |
| 114 | Inverter Design Advanced Sine-weighted High Frequency PWM using IGBT with instantaneous Sine-wave Control and Active Power factor Correction. |
| 115 | Duty Continuous operation. |
| 116 | Output waveform on mains run & on battery runPure Sinusoidal. |
| 117 | Regulation Full time output Voltage and Frequency regulation. |
| 118 | Mode of operation 60KVA Modular UPS,expandable up to 100KVA, with each module of 20KVA. |
| 119 | Modular System. |
| 120 | Modules type Hot swappable power modules, module should be online hot swappable without transferring the loads to bypass arrangement (all modules shall be of same rating). |
| 121 | Power module rating 05KW-20KW. |
| 122 | Controller Hot swappable power modules controller shall be independent and shall contain full rated Rectifier & Full rated Inverter. |
| 123 | Input. |
| 124 | Input voltage range 320 V to 460V AC 3 Phase + N & PE. |
| 125 | Input Frequency 45 - 65 Hz (auto sensing). |
| 126 | Total Harmonic Distortion input < 3% for 100% of nominal load. |
| 127 | Input Power factor ≥ 0.99 at Full Load. |
| 128 | Input phase reversal UPS should be with input phase reversal protection so that UPS keep working normally without draining the batteries. |
| 129 | Output. |
| 130 | Output voltage 380, 400, 415V, 3Ph + N + PE. |
| 131 | Load Type unbalanced type. |
| 132 | Output Frequency 50 /60 Hz (automatically selectable). |
| 133 | Nominal Power 60 kVA/60KW. |
| 134 | Total Harmonic Distortion (voltage) <1% for linear load and <5 % for non-linear load. |
| 135 | Output Power factor Unity. |
| 136 | Static Voltage regulation ± 1%. |
| 137 | Overall efficiency of UPS Upto 96% on 100% loading. |
| 138 | Current crest factor 3:1 accordingly with IEC EN62040-3. |
| 139 | Permitted overload 115% for 10 Minutes and 130% for 60 Seconds, with no bypass intervention. |
| 140 | Bypass. |
| 141 | Inbuilt Automatic Static Bypass Static bypass should be inbuilt in each power module so that there should be no single point of bypass failure. ie Static bypass should not be centralized. |
| 142 | Bypass Synchronization Synchronization of each inverter in phase and frequency with the bypass source shall be automatic. During transfer, the load shall not suffer an outage or disturbance in the supply of power. |
| 143 | Maintenance/ Manual Bypass facility Required as built-in manual bypass. |
| 144 | Battery. |
| 145 | Battery type Sealed Lead Acid Maintenance Free, installed into the system or in a dedicated external battery cabinet for safety. |
| 146 | Battery Bank capacity in VAH Min 57600 VAH 40 batteries 12V,120Ah, for 30minutes of battery back-up. |
| 147 | Charger Design Low Ripple Constant voltage, constant current (CVCC) Battery Charging. |
| 148 | Charger Type PWM hi efficiency, one in each power module. |
| 149 | Cold Start UPS must be able to start up without the input mains, just using the batteries. |
| 150 | Battery accessories All accessories like Battery Leads, Copper FRLS cables, Copper thimble on both ends of suitable ratings, battery shorting links & battery Charging system etc. to be provided, All cabling from battery bank to UPS. |
| 151 | Protection. |
| 152 | Isolation Transformer UPS shall have internal/external 60 kVA Isolation Transformer of same OEM Make only. |
| 153 | ProtectionsDischarge at battery terminals, Output Overload & Short Circuit etc. as per latest UPS industry standard Input Over Current, Input Under/ Over Voltage, Output Under/ Over Voltage, Over Temperature, Battery Under/ Over Voltage Deep. |
| 154 | User Interface & Communication. |
| 155 | LCD Display Required to display load percentage, UPS internal fault, UPS status, metering, Battery status- Battery Voltage, Charging Current, Battery charging percentage, Discharging Current, Residual Capacity, Battery Operation time, Battery fault; Alarms- Mains On, Inverter On/Off/ Faulty indication, Battery level, Static Bypass ON, Load level, Over temperature, Mains failure, Low Battery, Over Load, Load On Bypass etc. as per latest UPS industry standard. |
| 156 | Communication interface Optional SNMP card for remote monitoring through LAN network. |
| 157 | Environmental Specs & Certification. |
| 158 | Operating temperature 0 to 40 deg C. |
| 159 | RH Up to 95% Non-condensin. |
| 160 | Max. Audible Noise at 1 mtr. from unit 65 dBA or less at 100% load. |
| 161 | UPS enclosure's degree of ingress protection IP20. |
| 162 | Certification EN 62040-1, EN 62040-2 & IEC 62040-3, CE/UE/BIS & ROHS /PEP certification. |
| 163 | Quality System ISO 9001, 14001 & 45001. |
| 164 | Test Report / Certificate Bidder to submit Type test performance report of offered product Model from any Govt. Testing LAB / NABL accredited LAB in India to justify the asked technical compliance. |
| 165 | Warranty. |
| 166 | Warranty 03 Years on UPS & Isolation Transformer. |
| 167 | Warranty on Batteries The batteries shall be guaranteed for a period of 03 Years. |
| 168 | Approved Makes:-Schenider (APC), Emerson (Vertiv), Legrand, Numeric and Eaton for UPS & Exide / Quanta/ Panasonic for Batteries or as approved by Engineer-in-charge. |
| 169 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required. |
| 170 | Armoured cable 150 sq. mm (3.5 core). |
| 171 | Supply, Installation, Testing and Commissioning of perforated cable tray of following sizes including fixing the cable tray on the wall/ ceiling as required with nuts and bolts complete in all respects with fixing the cable in side the tray with best satisfaction of Engineer-in-charge. |
| 172 | 300mm X 75mm cable tray (14SWG). |
| 173 | 450mm X 75mm cable tray (14SWG). |
| 174 | Providing D.G. Set:- Supply, installation, testing & commissioning of 125KVA 3 Phase 415V, 50HZ, Diesel Generator set with following description and specifications:- |
| 175 | Diesel Engine. |
| 176 | Type The Diesel Engine shall be suitable for generating set application developing minimum 156 BHP at 1500 RPM under NTP conditions of BS: 5514 or equivalent in IS, Liquid cooled, Turbo Charged Inter Cooled with powered by four (4) strokes, multi cylinder with Engine performance requirement as specified below. |
| 177 | Nominal Output to match with, alternator 125 KVA i.e. 100KW at 8 PF. |
| 178 | Number of cylinders 4/Inline. |
| 179 | Number of Stroke 4. |
| 180 | Displacement (L) 4.32ltrs (Approx). |
| 181 | Bore X Stroke (mm) 105 X 125 (Approx). |
| 182 | Compression Ratio > 17. |
| 183 | Rated RPM 1500. |
| 184 | Overspeed trip (RPM) 1650. |
| 185 | Governor type/Class Electronic/A2 or better. |
| 186 | Type of cooling Liquid Cooling. |
| 187 | Starting system 24V DC Electrical,130Ah batteries. |
| 188 | Lube oil CK4,12-17Ltrs. |
| 189 | Coolant capacity 18 ltrs (approx). |
| 190 | Fuel tank capacity 230 ltrs. |
| 191 | Salient feature of engine turbo charged, direct injection fuel system, cold starting Kit. |
| 192 | Alternator. |
| 193 | Type/Capacity Self excited /125KVA. |
| 194 | Conformity to Indian Standard (for Alternator) Generally conforming to IS:13364 (Part-2) latest (Above 20KVA). |
| 195 | Type of alternator Brushless. |
| 196 | IP Rating IP 23. |
| 197 | Class of Insulation H. |
| 198 | Voltage Regulator Solid State Electronic type. |
| 199 | Connection Star, with neutral terminal wired upto external bushing. |
| 200 | Cooling Self cooled. |
| 201 | The generator set shall be able to withstand a Single phase short circuit at its terminal for three (3) seconds without any injury to the machines. This shall be suitable for transient load changes and high motor starting current. Cable gland sand lugs, suitable for termination of cable to the generator shall also be supplied. |
| 202 | Control Panel. |
| 203 | Control Panel AMF Control Panel. |
| 204 | Location Outside the canopy. |
| 205 | IP Rating IP 53. |
| 206 | Display meters in the control panel (with appropriate rating and accuracy class ) - inclusive in the scope of supply Multifunctional Digital display meter (displaying Voltage, Current, Frequency, Power Factor). |
| 207 | Displayed parameters/ Features Engine Speed,Lube oil pressure, Coolant/ cylinder head Temperature, Engine running hours,Engine battery voltage, Engine Running status Generator Voltage (PhPh), Generator Voltage (Ph-N), Generator Current (R, Y, B), Generator apparent Power (kVA), Generator active Power (kW), Powerfactor, Frequency, Fuel level, Control supply Voltage. |
| 208 | Indicator Low Lube oil pressure, High water / coolant / cylinder head temperature, Low fuel level, Over speed. |
| 209 | Audio Alarm Low Lube oil pressure,High water / coolant / cylinder head temperature, Low fuel level, Over speed. |
| 210 | Enclosure. |
| 211 | Acoustic Enclosure (inclusive in the scope of supply) Yes, Power Generator supplied with Acoustic Enclosure. |
| 212 | Sheet Thickness (mm) 1.60mm. |
| 213 | Thickness of insulation 40 millimeter. |
| 214 | Density of insulation 28. (kg/cubic m) |
| 215 | Noise level at 1.00 meter (dB) 75. |
| 216 | Salient feature:- Glass window on Accoustic Enclosure in front of the Control Panel, Emergency Stop outside the Accoustic Enclosure. |
| 217 | General Technical Requirements (GTR) / Commissioning |
| 218 | General Technical Requirements (GTR) / Power Generator shall be complete with Diesel Engine, Alternator and AMF/ Manual Control Panel along with Acoustic Enclosure. Diesel engine and alternator shall be closely coupled or provided with flexible coupling and mounted on a base plate / M.S. frame of robust in construction Commissioning (Part-1). |
| 219 | General Technical Requirements (GTR) / Commissioning (Part-2 Anti-Vibration mountings shall be provided for complete Power Generator in case of flexible coupling. In case of direct coupling Anti-Vibration mountings shall be provided for the Engine as well as the alternator. |
| 220 | General Technical Requirements (GTR) / Commissioning (Part-3) Power Generator should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. |
| 221 | General Technical Requirements (GTR) / Commissioning (Part-4) Automatic Mains Failure (AMF) control panel, where applicable, shall be able to start up the Power Generator and transfer the load on to the Power Generator on mains failure without requiring any human intervention. Similarly on restoration of mains supply, it shall be able to transfer the load to mains supply and switch off the Power Generator automatically. |
| 222 | General Technical Requirements (GTR) / Commissioning (Part-5) Control Panel (Manual / AMF), where applicable, shall be equipped with suitable Voltmeter, Ammeter, Frequency meter, power factor meter (these items can be alternatively supplied in one multifunctional digital display meter), battery charger, indicators, various switches and cutout / MCB / MCCB / Contactor / Circuit breaker for the DG output of appropriate rating and accuracy class as per trade practice for better utility. |
| 223 | General Technical Requirements (GTR) / Commissioning (Part-6) Supply of Fuel tank of suitable capacity, sufficient for minimum 8 hours running/990 liters(whichever is lower) the Power Generator, is inclusive in the scope of supply. Fuel Tank shall be complete with fuel piping (between fuel tank and diesel engine), valves, level indications and all standard accessories. MS pipes, heavy class of suitable dia conforming to IS 1239 (Part-1) - latest shall be used for fuel piping. This shall includes fuel charging of the fuel tank. |
| 224 | WARRANTY/SERVICES:- Warranty on Complete power genertor/DG Set 24 month, Warranty in running hours 5000 hour Number of preventive maintenance visits offered in an year during warranty period (Supply of all consumables is the buyer's responsibilty)* 1 Response Time to attend the complaint during Warranty 7day Makes:-Kirloskar /Sudhir /Volvo/ Caterpillar, Ashok leyland or as approved by Engineer-in-charge. Complete job. |
| 225 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1KV grade of following sizes on wall surface as required. |
| 226 | Armoured cable 150 sq. mm (3.5 core). |
| 227 | Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 228 | Providing and fixing 25mm X 5mm copper strip on surface or in recess for connections etc. as required. |
| 229 | Providing CCTV Cameras:- Supply, installation, testing and commissioning of minimum 8MP Network IR Bullet Camera having 1/2.7\\" 8MP PS CMOS Image Sensor (0.9407 centimeter), and with Effective Pixels 3840(H) × 2160(V), Minimum Illumination 0.02 Lux @ (F2.0, AGC ON), B/W: 0 Lux with IR, having Shutter Speed Auto:1/3-1/100000Sec, must have Gain Control (AGC) Support, with 3.60mm Fixed Lens and Max. Aperture F1.6. The S/N Ratio should be min 60dB, having Video Compression of Main Stream: H.264,H.265, Sub Stream: H.264,H.265, MJPEG, Back Light Compensation BLC/ WDR, supported angle of View Horizontal- 80°, Vertical- 56°, Diagonal- 107°, Should have supported frame rates of Main Stream 1: 3840 x 2160@20fp, 2880 x 1620@ 20fp,1920 X 1080@20fps/1280 x 720@ 20fps, and Sub Stream:720 x 480 @20fps, 352 x 288 @20fps should support Motion detection, must support Privacy Mask, ROI Support, Audio Compression G711A,G711U, AAC, Image Config requirements: Saturation, Brightness, Contrast, Sharpness, Mirror, 3D NR, White Balance, Anti Flicker, Video Tampering, HLC, Supported TV System PAL/NTSC, Supported Protocols: TCP/IP,IPv4, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTSP, NTP, SMTP, UDP, Qos,802.1x, ONVIF 19.12(Profile S/T), Should support recording mode via NVR/CMS/ Web, must have Day/Night Color/ B&W (IR-CUT), Ethernet RJ-45 (10/100Base-T), should support Browser types: IE8-11, Google Chrome, Firefox, Mac Safari, IR Power On modes support shuld be Manual & Timed mode, Smart Phone iPhone, iPad, Android Phone, Min IR Range 30 Mtr, should support POE Internal, Support IEEE 802.3af, Operating Temperature should be between-20°C ~ +60°C, Min Operating Humidity ≤95%(RH), Support for Intrusion Detection, Line Cross Detection, Loiter Detection, People Gather Detection, Motion detection based on human detection, Corridor Pattern, Power Source: DC12V±10%, 700mA complete in all respects Make:- Axis, Pelco, Avigilon, Mobotix, Honeywell, or as approved by Engineer-in-charge. |
| 230 | Supply, installation, testing and commissioning of 32Channel 4K AI Network Video Recorder having suuport of Industrial-grade processor, should support min IP Camera Input of 32 Channel, Operating System Embedded LINUX, User Interface support required: Web, Local GUI, Must have Video Output: Min. 2 VGA:1920 × 1080, 1280 × 1024, 1280 × 720, Min. 2 HDMI:3840 × 2160, 1920 × 1080, 1280 × 1024, 1280 × 720, Must support Heterogeneous video source output for HDMI1 and HDMI2, must support Simultaneous video source output for VGA1 and HDMI1 and simultaneous video source output for VGA2 and HDMI2, must support Video Compression Instastream: H.265, H.264+, H.264, MJPEG, Must have AI by NVR Face detection, Face recognition, Perimeter protection, SMD Plus, Must have AI by Camera Face detection, Face recognition, Video metadata (Human, Motor vehicles, Non-motor vehicles), Perimeter protection, SMD Plus, Stereo analysis, Crowd distribution, People counting, ANPR, Vehicle density, Heat map, Supported Resolution: 32 MP, 24 MP, 16 MP, 12 MP, 8 MP, 6 MP, 5 MP, 4 MP, 2 MP, 720p, 960p, D1, CIF, QCIF, Should support Video Display Split Main screen: 1/ 4/ 8/ 9/ 16/ 25/ 36, Sub screen: 1/ 4/ 8/ 9/ 16, should support Face Database Capacity: Up to 20 face databases with 20,000 images, with a total capacity of 2.5 G, Min License Plate Database Capacity: must create up to 20,000 plate numbers, Blocklist and allowlist, must support Abnormality Alarm: Camera offline, Storage error, Disk full, IP conflict, MAC conflict, Login lock, Abnormal behaviour of fan, Cyber security exception, Hard Disk support: 4 SATA ports, Storage Surveillance System 10 TB HDD capacity x 4 Hard Disks, Multi-channel Playback Up to 16 Channels, Record Mode: General, Motion detection, Intelligent, Alarm, POS, must support the Backup Method: USB device and network. Should support Smart Phone iPhone, iPad, Android Phone, SUPPORTED Browsers: Chrome, IE, Safari, Edge, Firefox, Must have Ethernet Ports: 2 (10/100/1000 Mbps Ethernet port, RJ-45), Power Consumption Total output of NVR must be ≤ 13 W (without HDD), Storage Temperature between -20 °C to +60 °C (–4 °F to +140 °F) complete in all respects Make:- Axis, Pelco, Avigilon, Mobotix, Honeywell, or as approved by Engineer-in-charge. |
| 231 | Supply, installation, testing and commissioning of 65\\" 4K UHD Commercial LED TV with minimum Resolution (3,840 x 2,160), Backlight Type: Direct, Required Refresh Rate: 60 Hz Native, Picture Processor: Min. α5 AI Processor 4K Gen7, Reqd. Number of CPUs: Quad, must support 4K AI Up scaling, must have support of Auto Calibration, Should be Bluetooth Surround Ready, Required Audio Output (Woofer / per Channel): 20 W (10 W per Channel), should support Speaker System: 2.0 Channel, Built-In Ethernet LAN Connectivity, HDMI Input (3, Supports eARC, ALLM as Specified in HDMI 2.1), HDMI Audio Return Channel (eARC (HDMI 2), USB Input (2, v 2.0), Wi-Fi 5, Bluetooth Support (v 5.0), Ethernet Input, RF Input (2, Antenna / Cable), SPDIF (Optical Digital Audio Out) complete in all respects as directed by Engineer-in-Charge Make:- LG, Sony, Panasonic, Samsung or as approved by Engineer-in-charge. |
| 232 | Supply, installation, testing and commissioning of 10metre 4K HDMI to HDMI Cable having full shield and gold plated connectors Up to 4K resolution at 30Hz on surface or in PVC Casing Capping as per site requirement complete in all respects Make:‐ Belkin, Key Digital, Revetron or as approved by Engineer in charge. |
| 233 | Supply, installation, testing and commissioning of wireless Mouse having Sensor technology: Smooth optical tracking, DPI (Min/Max): 1000±, Buttons: Number of buttons: 3 (Left/Right-click, Middle click), Scrolling: Line-by-line scrolling, Scroll Wheel: Yes, 2D, optical, Battery: 1X AA, Connectivity: Connection Type: 2.4 GHz wireless connection, Min wireless range: 10 metre, Connect/Power: Yes, with on/off switch as required complete in all respects Make: ‐ Logitech, HP, Microsoft or as approved by Engineer-in-charge. |
| 234 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 235 | 1 run of cable. |
| 236 | 2 run of cable. |
| 237 | Providing and fixing RJ 45 connectors with T568B configuration in clear polycarbonate housing,operating temperature -10 to 60 degree celsius, maximum cable jacket diameter 6.5mm including making necessary connections as approved Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand or as approved by Engineer-in-charge. |
| 238 | Supply and installtion of 6U Networking Rack with following specifications Rack Standard: Conforms to DIN 41494 or equivalent, standard construction : Welded, Front Door : Lockable Toughened Glass, Door Basic Frame : Steel, Equipment Mounting : DIN Standard Slots, Mounting Angle : 19” Mounting angles made of formed steel, Standard Finish : Powder Coated, Top and Bottom Cover : Welded to Frame, Vented and Field Cable entry exit cut outs, Standard Color : Grey, Static load : 40 kgs. complete in all respects Makes:- Comrack, Rittal, Netrack or as approved by Engineer-in-charge. |
| 239 | Supply and installtion of 8 Port POE Switch with following specifications: Interfaces • 8 10/100/1000 BASE-T ports, 2 GE (Gigabit Ethernet) ,Standards • IEEE 802. 3u, Fast Ethernet standards • IEEE802.3af/at, Ethernetpower supply POE standards• IEEE 802.3ab, Gigabit Ethernet standards • IEEE 802.3az, EEE, Energy efficient Ethernet standard • IEEE 802.3x, Full-duplex Ethernet data link layers• IEEE 802.3z, Gigabit Ethernet fiber-optic standard,Media Interface Exchange • Auto MDI/MDI-Xadjustment on all ports, Lighting Protection 6KV, Switching Fabric 20 Gbps •Transmission Method : Adopt Store-and-forward, Packet Filtering / Forwarding Rates 10M port maximum 14800pps 100M port maximum 148800pps 1000M port maximum 1488000pps,PoE Standards IEEE 802.3af IEEE 802.3at,PoE-Capable Ports Port 1 - 8 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled), Power Budget 120W (30 W max. per PoE port, Temperature Operating: 0 to 40 ˚C (32 to 104 ˚F), Humidity Operating: 0% to 95% RH non-condensing complete in all respects Makes:- Rukus, Cisco, Juniper or as directed / approved by Engineer-in-charge. |
| 240 | Supply and installtion of 16 Port POE Switch with following specifications: Interfaces • 16 10/100/1000 BASE-T ports • 2 SFP,Standards • IEEE 802.3u,Fast Ethernet standard • IEEE 802.3af/at, Ethernet power supply POE standard • IEEE 802.3ab, Gigabit Ethernet standards • IEEE 802.3az ,EEE, Energy efficient Ethernet standard • IEEE 802.3x, Full-duplex Ethernet data link layers • IEEE 802.3z ,Gigabit Ethernet fiber-optic standard, Media Interface Exchange • Auto MDI/MDI-X adjustment on all ports,Lighting Protection • 6KV,Switching Fabric • 36 Gbps Transmission Method • Adopt Store-and-forward,Data Transfer Rates Gigabit Ethernet 1000 Mbps, Ethernet 100Mbps,Packet Filtering / Forwarding Rates 10M port maximum 14800pps,100M port maximum 148800pps, 1000M port maximum 1488000pps, PoE Standards IEEE 802.3af IEEE 802.3at,PoE-Capable Ports Port 1 - 16 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled),Power Budget 150W (30 W max. per PoE port), Power 150W, Temperature Operating: 0 to 40 ˚C (32 to 104 ˚F), Humidity Operating: 0% to 95%RH non-condensing complete in all respects Makes:- Rukus, Cisco, Juniper or as directed / approved by Engineer-in-charge. |
| 241 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 242 | 25mm dia. |
| 243 | 32mmdia. |
| 244 | Providing Servo Stablizer:- Supplying, Installation, Testing and Commissioning of Oil cooled 300KVA automatic servo controlled voltage stabilizer Suitable for 3 phase unbalanced load & supply having input range of 300- 480 volts and output range 415 AC+/-1% volts along with High/ Low voltage cut-off protection/ sytem, & bypass arrangements & phase reverse cut off & should have Linear/ Roller type continously voltage regulator technology, double wound copper conductor regulators transformer, control motorised digital micro processor module type, auto & manual, low & high voltage indication, mode of operation: auto, manual mode, metering digital voltmeter on input & output with phase selector switch, amp volt meter on output with CT & selector switch, control circuit protection with MCB on outer side of control panel, Cooling oil cooled including oil complete in all respect as desired by engineer at site. Warranty five Years for transformer & regulators & one year for switchgear, synchronous motor, digital meters, microprocessor controller etc. Make:- Selvon, JBI, Servokon syatem, Jindal electric or its equivalent as approved by Engineer in charge. |
| 245 | Providing & laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.10 KV grade of following sizes on wall surface as required. |
| 246 | Armoured cable 300 sq. mm (3.5 core). |
| 247 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 248 | Providing and fixing 25mm X 5mm G.I. strip on surface or in recess for connections etc. as required. |
| 249 | Providing and installation of 300 KVA voltage stabilizer at the designated location and placement using a chain pulley system. The scope includes deployment of necessary labor and skilled OEM (Original Equipment Manufacturer) technicians for fixing, assembling, and commissioning of the stabilizer. All necessary electrical connections shall be carried out to ensure the equipment is fully operational. The job shall be completed in all respects to the satisfaction of the Engineer-in-Charge. |
| 250 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 251 | 160 mm dia (OD-160 mm & ID-135 mm nominal). |
| 252 | Providing LAN System:- Supplying and drawing of UTP 4 pair CAT 6 or above LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand or as directed by the Engineer-in-Charge. |
| 253 | 1 run of cable. |
| 254 | 2 run of cable. |
| 255 | 3 run of cable. |
| 256 | Providing and fixing CAT 6A RJ45 Information Outlet wall socket with SMB, High impact flame retardant plastic, Polycarbonate UL 94V-0 rated housing, Plug & Jack Contact Force :100 Grams minimumusing FCC-approved plug,Durability : 200 Termination cycles ,Storage Temperature : -40°F to 150°F (-40°C to 68°C) Operating Temperature : -10°C to 60°C including making necessary connections & testing Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand or as directed by the Engineer-in-Charge. |
| 257 | Providing and fixing CAT 6A 24 Port Patch Panel, made of Steel Plate Cold Rolled Commercial material,1.5mm thickness with black color painted, RJ45 Jack: Housing: ABS, UL 94V-0 Contact Brackets: PC, UL 94V-2, transparent color, RJ45 Jack contact: Material- phosphor bronze with nickel plated Finish: 50 micro-inches Gold plated on plug contact area,Support Bar:SPCC, 1.5 mm thickness with black color painted,Cable Manager:19 \\" rack mountable, Metallic high strength with metal jumper rings for routing cable assemblies, mounts to the front of 19” rack & 1 U height,Contact Resistance: 100 Milliohms max. Insulation Resistance: 1000 Megaohms min. g 500 VDC RJ45 Jack Life: 750 Times min IDC Life: 200 Times min Storage: - 40”To + 70 ” Operation: -10 to + 60 ”. Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand or as directed by the Engineer-in-Charge. |
| 258 | Supply and installtion of 9U Networking Rack with following specifications Rack Standard : Conforms to DIN 41494 or equivalent, standard Construction : Welded, Front Door : Lockable Toughened Glass, Door Basic Frame : Steel, Equipment Mounting : DIN Standard Slots, Mounting Angle : 19” Mounting angles made of formed steel,Standard Finish : Powder Coated, Top and Bottom Cover : Welded to Frame, Vented and Field Cable entry exit cut outs,Standard Color : Grey, Static load : 40kgs. complete in all respects Makes:- Comrack, Rittal, Netrack or as approved by Engineer-in-charge. |
| 259 | Providing and fixing 24 Port Rack Mountable 10/100/1000 Managed L2 Gigabit Switch with 2X 10/100/1000 Mbps uplink RJ-45 ports, 4X1/10 GbE uplink/stacking SFP/ SFP + ports Makes:- Rukus, Cisco, Juniper or as directed / approved by Engineer-in-charge. |
| 260 | Providing and fixing patch cord CAT 6A each with RJ45 connectors at both ends complete Make:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. as approved and directed by the Engineer-in-Charge |
| 261 | 1.00 metre. |
| 262 | 2.00 metre. |
| 263 | Supplying, installation, testing and commissioning of single mode Optical fiber cable having following specifications:- |
| 264 | Optical Specifications. |
| 265 | Attenuation. |
| 266 | Attenuation at 1310 nm 0.33 – 0.35 dB/km.Attenuation at 1383 nm 1 dB/km.Attenuation at 1550 nm 0.19 – 0.22 dB/km.Attenuation at 1625 nm 0.21 – 0.24 dB/km. |
| 267 | Attenuation with Bending. |
| 268 | Number of Mandrel Radius Wavelength Induced Attenuation (dB).Turns (mm) (nm) 100 25 1310 < 0.05.100 25 1550 < 0.05.100 30 1625 < 0.05. |
| 269 | Mode Field Diameter. |
| 270 | Wavelength (nm) MFD (µm).1310 9.0 +- 0.4.1550 10.1+- 0.5. |
| 271 | Geometrical Specifications. |
| 272 | Glass Geometry. |
| 273 | Cladding Diameter 125.0 +- 1.0 µm.Core/Cladding Concentricity Error <=0.6 µm.Cladding Non-Circularity <= 1.0 %.Fiber Curl (Radius) >= 4 m. |
| 274 | Mechanical Specifications:- The entire length is subjected to a tensile proof stress >= 0.7GPa (100 kpsi) 1% strain equivalent Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. |
| 275 | Providing and fixing LIU 24 Port, Metal Shelf Cold Steel, 1.20mm Thickness, Cover and Front Panel Alum.,1.20mm Thickness Metal Mounting Ear Cold Steel, 2.0mm Thickness, Splice Tray ABS, Adapter Panel Cold Steel, 1.50mm Thickness, Cable Plug Rubber complete as required Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. |
| 276 | Providing and fixing LIU 12 Port, Metal Shelf Cold Steel, 1.2mm thickness, Cover and Front Panel Alum., 1.2mm Thickness Metal Mounting Ear Cold Steel, 2.0mm Thickness, Splice Tray ABS, Adapter Panel Cold Steel, 1.5mm Thickness, Cable Plug Rubber complete as required Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. |
| 277 | Supplying,installation,testing and commissioning of Pigtail with SC Connector complete as required with all necessary connections Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. |
| 278 | Supplying, installation, testing and commissioning of Fiber Patch Cord with Subscriber Connector (SC) at one end and Lucent Connector (LC) at other complete as required with all necessary connections Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. |
| 279 | Supplying, installation, testing and commissioning of gigabit ethernet single mode 10G SFP Transceiver complete as required with all necessary connections Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand. |
| 280 | Providing termination of fiber cable by splicing of fiber at different locations required at site complete in all respects as required maintaning the optical performance of the fiber, mechanical strength and accuracy with best satisfaction of Engineer-in-charge. |
| 281 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 282 | 25 mm dia. |
| 283 | 32mmdia. |
| 284 | Providing IPPBX System:- Supply, Installation, Testing and Commissioning of SIP IP Phone 5\\" 1280mm X 720mm capacitive touch screen IPS LCD, Dual Gigabit switched auto sebsing ports, Integrated wifi6 (2.4 g and 5ghz) android 14, bluetooth 5ver for synchronising of mobile device,dual mic with NSAAC 2mp XCMOS camera with shutter complete with all necessary conncections as required Make:- Yeaster, Snom, Grand stream, Coral, Matrix or as approved by Engineer-in-charge. |
| 285 | Supply, Installation, Testing and Commissioning of SIP IP Phone Dual switched auto sensing gigabit POE Ethernet port, HD audio, 24Blf keys, 2.5 inch 320 X 240 TFT color LCD, bluetooth complete in all respects as required Make:- Yeaster, Snom, Grand stream, Coral, Matrix or as approved by Engineer-in-charge. |
| 286 | Supply, Installation, testing and commissioning of SIP Phone with LCD display 240 X 64 pixel 16, Memory/ DSS, MWL, 802AF Support, SIP, V,TLS, SRTP for voice Make:- Yeaster, Snom, Grand stream, Coral, Matrix or as approved by Engineer-in-charge. |
| 287 | Supply, Installation, testing and commissioning of 24 port POE ++ gigabit Switch with 350watt power, MDI/MDI-x, IEEE 802.3 Aad POE Protocol, bandwidth 56 gbps, snmp. Makes:- Rukus, Cisco, Juniper or as directed by Engineer-in-charge. |
| 288 | Supply, Installation, testing and commissioning of wall mount 9U rack fully loaded with 24 port patch panel and compartment for LAN switches complete in all respects as required Makes:- Comrack, Rittal, Netrack or as approved by Engineer-in-charge. |
| 289 | Supply, Installation, testing and commissioning of face plate and keystone of RJ45 connector suitable for various telephone sets complete with all necessary connections as required Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand or as approved by Engineer-in-charge. |
| 290 | Providing and fixing patch cord CAT 6A each with RJ 45 connectors at both ends complete Makes:- Molex, Belden, Panduit, Commscope, R&M, Systimax and Legrand or as approved by the Engineer-in-Charge. |
| 291 | Patch cord 1 metre. |
| 292 | Patch cord 3 metre. |
| 293 | Supplying and drawing of UTP 4 pair CAT 6 or above LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 294 | 1 run of cable. |
| 295 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 296 | 25mm dia. |
| 297 | Providing Audio Video System:- Supply, installation, testing and commissioning of Integrated Flush Mount Chairman conference unit with Digital Signal Processing Unit with Priority and Next-in- Line Configuration, Priority button silences all delegate microphones and allows only the chairperson to speak, Next- in-line button gives the floor to the next speaker in a waiting list of speakers who requested to speak, tactile microphone push button with integrated LED, Screw-lock socket for microphone. Construction :Steel/ Metal, Connectivity:› 2 x RJ 45 ethernet port (IN/OUT - interchangeable).› Loop through, daisy-chain cabling (non-proprietary).› Audio quality 16 bit digital›Frequency response 25 Hz-15,000 Hz (± 3 dB) Certification: CE; BIS.The OEM, product and bidder shall not share the common borders with India and adhere to GFR 144 (xi) guidelines of purchase manual Make: Televic, Audio -technica, Heinrich or as approved by Engineer-in-charge. |
| 298 | Supply, installation, testing and commissioning of integrated flush mount delegate conference unit with Digital Signal Processing, tactile microphone ON/ OFF push button with integrated LED, Screw-lock socket for microphone Construction: Steel/ Metal, connectivity:› 2 x RJ 45 ethernet port (IN/OUT - interchangeable).› Loop through, daisy-chain cabling (non-proprietary).› Audio quality 16 bit digital.›Frequency response 25 Hz-15,000 Hz (± 3 dB) Certification: CE; BIS.The OEM, product and bidder shall not share the common borders with India and adhere to GFR 144 (xi) guidelines of purchase manual Make: Televic, Audio -technica, Heinrich or as approved by Engineer-in-charge. |
| 299 | Supply, installation, testing and commissioning of 19\\" rack mountable hibrid ready Central Conference Controller with Recording & Web Server, 4 Bus Connections (4 branches or 2 closed loops) for fail-safe redundancy technology, The controller should support total cable length of a branch / loop are up to 400M or more. The maximum cable length between units or between units and central unit is 80M or more, Control & Configure the controller via the Integrated Web Server, The Controller easily integrated by using USB audio, AES-67 and analogue audio, control up to 250 or higher units by adding network extenders, Hands-free mode upto 16 microphones or better, no need to push/press button, Camera Control integration capability, The conference units are connected in daisy chain with a CAT5e or better shielded cable (non-proprietary) over the 4 bus connections, AES67 and the multi-channel USB connection which allows to link the system with external devices such as a DSP or an external recording solution, The controller can be configurable in DSP Mode, Audio configurator, can choose where the audio is routed to and group microphones and speakers together, Recording capabilities › Internal storage- 3GB or better › External flash drive via USB-C › On a PC via multi-channel USB connectionPower button, Fan-less operation, Extended power, Wake-On- Lan, Auto Power-on, ECO mode, Volume dial- adjusts the system volume, Record button-for starts or stops the recording, Audio & Control feature like Dynamic Mix-Minus, Gain Sharing, API Control, Connectivity: 4x Bus connections (4 branches or 2 loops), LAN connection (Control & AES-67), 2x Lockable USB-C connections for Flash drive interface, Hybrid meeting Interface & Multi-channel audio interface. 2x Balanced XLR inputs, 2x Balanced XLR outputs, 1x Front- facing 3.5mm input & output jack for line or microphone level. 1x Power connection, Link speed 10/100 Mbps - 1 Gbps or better over the Network, Included power supply for central unit: 48 VDC, Certification: CE,. The OEM, product and bidder shall not share the common borders with India and adhere to GFR 144 (xi) guidelines of purchase manual. Make:- Televic, Audiotechnica, Heinrich or as approved by Engineer-in-charge. |
| 300 | Supply, installation, testing and commissioning of 40cm, Cardioid, Back electret-condenser gooseneck microphone with Screw Lock connector, Shielded microphone, immune to mobile phone interference, Microphone with Ring Indicator to light up Red when active and Green when in Request, CE Certification. Having following specifications:- Max SPL @ 1kHz: 110 dB SPL (1% THD+N) S/N Ratio: > 67 dB(A). Sensitivity: (-40.5±2) dBV @ 1Pa, 1KHz. Televic, Audiotechnica, Heinrich or as approved by Engineer-in-charge. |
| 301 | Supply, installation, testing and commissioning of Connection cable, 2m, black as approved by OEM of Conference System complete with best satisfaction of Engineer-in-charge. |
| 302 | Supply, installation, testing and commissioning of Connection cable, 20m, black as approved by OEM of Conference System complete with best satisfaction of Engineer-in-charge. |
| 303 | Supply, installation, testing and commissioning of 98” Diagonal Size, 780 cd/m2 brightness, Dynamic Contrast Ratio: 700,000:1 contrast ratio, Display resolution: 3840 x 2160 pixels, 4K Processor X1, Audio: 10Watt + 10Watt, Android TV Operating system, 32GB On-board storage, Integrated Wireless LAN, Wi-Fi certified, USB Playback codec, Built-in Chromecast, Airplay, Inputs and outputs - HDCP2.3 (for HDMI1 / 2 / 3/4), Composite Video Input (s) - 1, 4 HDMI inputs, Analog Audio Input -1, Digital Audio Output -1, USB ports - 2, Ethernet inputs-1 etc. Make: Sony, Sharp, Samsung or as approved by Engineer-in-charge. |
| 304 | Supply,installation,testing and commissioning of 43” Diagonal Size, 350 cd/m2 brightness, Dynamic Contrast Ratio: 400,000:1 contrast ratio, Display resolution: 3840 x 2160 pixels, 4K Processor X1, Audio: 10Watt + 10Watt, Android TV Operating system, 16GB On-board storage, Integrated Wireless LAN, Wi-Fi certified, USB Playback codec, Built-in Chromecast, Airplay, Inputs and outputs - HDCP2.3 (for HDMI1 / 2 / 3), Composite Video Input (s)-1, 3 HDMI inputs, Analog Audio Input - 1, Digital Audio Output -1, USB ports - 2, Ethernet inputs- 1 etc. Make: Sony, Sharp, Samsung or as approved by Engineer-in-charge. |
| 305 | Supply,installation,testing and commissioning of 65” Diagonal Size, 350 cd/m2 brightness, Dynamic Contrast Ratio: 400,000:1 contrast ratio, Display resolution: 3840 x 2160 pixels, 4K Processor X1, Audio: 10Watt + 10Watt, Android TV Operating system, 16GB On-board storage, Integrated Wireless LAN, Wi-Fi certified, USB Playback codec, Built-in Chromecast, Airplay, Inputs and outputs - HDCP2.3 (for HDMI1 / 2 / 3), Composite Video Input (s) -1, 3 HDMI inputs, Analog Audio Input -1, Digital Audio Output - 1, USB ports - 2, Ethernet inputs- 1 etc. Make: Sony, Sharp, Samsung or as approved by Engineer-in-charge. |
| 306 | Supply,installation,testing and commissioning of 85” Diagonal Size, 440 cd/m2 brightness, Dynamic Contrast Ratio: 400,000:1 contrast ratio, Display resolution: 3840 x 2160 pixels, 4K Processor X1, Audio: 10Watt + 10Watt, Android TV Operating system, 32GB On-board storage, Integrated Wireless LAN, Wi-Fi certified, USB Playback codec, Built-in Chromecast, Airplay, Inputs and outputs - HDCP2.3 (for HDMI1 / 2 / 3/4), Composite Video Input (s) - 1, 4 HDMI inputs, Analog Audio Input- 1, Digital Audio Output-1, USB ports- 2, Ethernet inputs- 1 etc. Make: Sony, Sharp, Samsung or as approved by Engineer-in-charge. |
| 307 | Supply, installation, testing and commissioning of Wall mount system for 98\\" LED Display TV complete in all respects with hanging the TV on wall/celing as required with best satisfaction of Engineer-in-charge. |
| 308 | Supply, installation, testing and commissioning of Wall mount system for 65\\"/43\\" LED Display TV complete in all respects with hanging the TV on wall/celing as required with best satisfaction of Engineer-in-charge. |
| 309 | Supply,installation,testing and commissioning of Ultra HD 4K video conferencing system, Video standards and protocols-H.264 AVC, H.264 High Profile, H.264,SVC, H.265, RTV, H.239, H.264 video error concealment, Video resolution-4K, 30 fps (TX & RX) from 2048 Kbps2, 1080p, 60 fps from 1740 Kbps, 1080p, 30 fps from 1024 Kbps, 720p, 60 fps from 832 Kbps, 720p, 30 fps from 512 Kbps, Video out - 2x HDMI, Touch Display Compatible, Video Input- 1 x HDCI, 1 x HDMI Audio Input- 1 x HDMI, 1 x 3.5 mm stereo line-in Audio output - 1x HDMI, 1 x 3.5 mm stereo line-out Network- IPv4 support, 1 x 10/100/1G Ethernet Camera: Type 1/2.7\\" CMOS, H/V Resolution 1920 x 1080, Zoom 12x optical Make: Cisco, Polycom, Life size or as approved by Engineer-in-charge. |
| 310 | Supply, installation, testing and commissioning of Partner Premier for 3 year for Video conferencing System complete as required. |
| 311 | Supply, installation, testing and commissioning of 8 X 8 HDMI 2.0 , HDCP 2.2 Matrix Switcher, Supports 4K @60Hz, 4:4:4 chroma sampling, and HDR (4K @60Hz, 4:2:0 10-bit), Audio 8X8, Audio Embedding & De-Embedding Control - front panel buttons, IR remote, RS-232, IP control, and WebGUI. Audio support: Dolby TrueHD, Atmos, DTS-HD Master Audio, and DTS:X Advanced EDID management, CEC, and ARC capabilities Make:- Extron, Kramer, Ecler or as approved by Engineer-in-charge. |
| 312 | Supply,installation, testing and commissioning of of 4x4 4K HDR HDMI HDCP 2.2 Matrix Switcher with Audio De-embedding, Resolutions up to 4K@ 60Hz, HDCP-compliant, Input/ Output LED display and IR remote control, 4 HDMI Input, Output: 4 S/PDIF; 4 Balanced Stereo Audio; 4 HDMI, Max. Data Rate: 18Gbps , Ports: PORTS,1 USB,1 RS-232,1 IR IN,1 Ethernet Make:- Bluestream, Kramer, Ecler or as approved by Engineer-in-charge. |
| 313 | Supply, installation, testing and commissioning of HDBaseT receiver, HDCP 2.2 compliant, 1 HDBT Input, HDMI output, Up to 4K UHD @60Hz, Up to 10.2Gbps bandwidth Make:- Extron, Kramer, Ecler or as approved by Engineer-in-charge. |
| 314 | Supply, installation, testing and commissioning of HD BaseT transmitter , HDCP 2.2 compliant, 1 HDMI Input, HDBT output, Up to 4K UHD @60Hz, Up to 10.2Gbps bandwidth Make:- Extron, Kramer, Ecler or as approved by Engineer-in-charge. |
| 315 | Supply, installation, testing and commissioning of of CAT6 Shielded cable that handles all Pro AV signals Make:- Kramer, Extron, Molex or as approved by Engineer-in-charge. |
| 316 | Supply, installation, testing and commissioning of 1 Mtr HDMI 2.0 Patch cable Make:- Kramer, Extron, Molex or as approved by Engineer-in-charge. |
| 317 | Supply, Installation, Testing & Commissioning of table mounted AV Pop up Box , with 1x Power, 1x LAN, 1x HDMI, Plug & play Make:- Kramer, Linetek, bestnet or as approved by Engineer-in-charge. |
| 318 | Supply, installation, testing and commissioning of Wide dynamic range gooseneck condenser (12 inch.) microphone with shock mount for podium and with the following specifications:- (a)Frequency Response :50 to 17,000 Hz (b)Output Impedance:EIA Rated at 150Ω (170Ω actual) (c)Open Circuit Sensitivity@ 1 kHz re: 1 V/microbar @ 1 kHz re: 1 V/Pascal - 35.0 dB (d)Max SPL (1 kHz at 1% THD, 1 kΩ load):124 dB (e) Max Equivalent Output Noise (A-weighted):28 dB (f)Dynamic Range:96 dB (g) Power Requirements:11 to 52 Vdc Phantom Power (h)Common Mode Rejection:45.0 dB minimum Make:- Shure, Ecler, Audio-technica or as approved by Engineer-in-charge. |
| 319 | Supply, installation, testing and commissioning of Handheld Microphone with Transmitter and microprocessor controlled diversity receiver, UHF high band frequency range 524-865 MHz, • Adjustable output level • Removable antennas • LCD display with detailed RFand audio metering • Rugged metal construction rack mount hardware, Auto Frequency Selection Up to 12 compatible systems per frequency band, Auto Transmitter Setup, Audio Reference Companding with the following specification:- System:(a) Frequency response: 50hz- 15 KHz (+/- 2 dB) (b) Dynamic range: 100 dB A-weighted (c) Operating Range: 300 Ft. (d) Audio Output connector : XLR balanced and ¼” unbalanced (e) Max. Output Level : -27 dBV (XLR, mic level), -13 dBV (¼”) (f) System Distortion : 0.5% THD typical (ref. +/- 33 kHz deviation, 1 kHz tone) Transmitter : i) LEDs / Switch : Power, mute and battery status LEDs ; Power and mute switch ( ii) Transmitter RF output Power : 10mw ( iii) Battery Life: >8 hours (continuous use) with 2AA (alkaline) batteries (iv) Audio Input Level : +2dBV max. at -10 dB ; -8dB max at 0dB (v) Gain Adjustment Range: 10dB Make:- Shure, Ecler, Audio-technica or as approved by Engineer-in-charge. |
| 320 | Supply, installation, testing and commissioning of Ceiling Speaker: wo-way ABS speaker, 20 WRMS • 5,25\\" woofer + 0,75\\" tweeter • Built-in audio transformer for 70/100 V • Clip-type input terminals and low impedance / high impedance power tap selector. Frequency response (-6 dB) 96Hz – 20kHz, Nominal high impedance 70/100V Line, Nominal low impedance 8Ω, RMS power 20 W, Sensitivity (dB@1m 1W) 86 dB Make:- Tannoy, Ecler, Tecnare or as approved by Engineer-in-charge. |
| 321 | Supply, installation, testing and commissioning of wall mounted speaker: Column type loudspeaker: 8 x 3”, 80 WRMS, Program Power 160 W, Aluminium enclosure, IP44 rated, Nominal low impedance 8Ω, Built-in audio transformer for 70/100 V, Frequency response (-6 dB) 200Hz -20kHz, Sensitivity 1W/1m 94 dB, Dispersion 130°V x 150°H Make:- Tannoy, Ecler, Tecnare or as approved by Engineer-in-charge. |
| 322 | Supply, installation, testing and commissioning of 4 Channel Amplifier, 4 analogue audio inputs and 4 x150 WRMS @ 70V / 100V powered audio outputs, fanless, 100% silent, Thermal protection, Overload protection, Anti- clip system, Volume control knobs on front panel, Frequency response (-1 dB, -3dB) 20Hz - 30kHz, THD+Noise @ 1kHz Full Power <0.05%, S+N/N 20Hz - 20kHz @ 1W/4Ω >85dB, CMRR >55dB, Damping factor 1kHz @ 8Ω >150, Channel crosstalk @ 1kHz >55dB, Input Sensitivity / Impedance 0dB/>20kΩ, Anticlip @ 2dBV input <1% THD, Efficiency @ Pmax 80%. Make: QSC, Ecler, Lapgruppen or as approved by Engineer-in-charge. |
| 323 | Supply, installation, testing and commissioning of 16-Channel Mixing Console, Max. 10 Mic / 16 Line Inputs (8 mono + 4 stereo), 4 GROUP Buses + 1 Stereo Bus, 4 AUX, 1-Knob compressors, PAD switch on mono inputs, +48V phantom power, XLR balanced outputs Make: Yamaha, Soundcraft, Allenheath or as approved by Engineer-in-charge. |
| 324 | Supply, installation, testing and commissioning of 10-Channel Mixing Console, Max. 8 Mic / 10 Line Inputs (6 mono + 2 stereo), 4 GROUP Buses + 1 Stereo Bus, 4 AUX, 1-Knob compressors, PAD switch on mono inputs, +48V phantom power, XLR balanced outputs Make: Yamaha, Soundcraft, Allenheath or as approved by Engineer-in-charge. |
| 325 | Supply, installation, testing and commissioning of Digital Signal Processor8 AEC Inputs (with 48v Phantom Power per cannel), 2 analog input, Codec input , 4 Analog Outputs, 1 Codec output Make: BSS, Ecler, Biamp or as approved by Engineer-in-charge. |
| 326 | Supply, installation, testing and commissioning of Two core shielded 19AWG Mic Cable complete with all necessary connections as required Make:- Krystal, Falcon, MX or as approved by Engineer-in-charge. |
| 327 | Supply, installation, testing and commissioning of Two core shielded 14 AWG Mic Cable complete with all necessary connections as required Make:- Krystal, Falcon, MX or as approved by Engineer-in-charge. |
| 328 | Supply, installation, testing and commissioning of various audio connectors required for complete audio system including connections of these connectors as required with best satisfaction of Engineer-in-charge. |
| 329 | Supply, installation, testing and commissioning of equipment Rack suitable to accommodate all rack mountable items of the audio/ vedio system complete in all repects as required with fixing the items in the rack with best satisfaction of Engineer-in-charge Make: Comrack, Massrack, Netgear or as approved by Engineer-in-charge. Note: The contractor/agency shall provide three years warranty and comprehensive maintenance for each item described in the schedule of quantity from the date of handing over the system to the client department. |
| 330 | Conditions:- |
| 331 | The work shall be carried out according to CPWD/HPPWD General Specifications. |
| 332 | The work shall be completed to the entire satisfaction of the Engineer-in-charge. |
| 333 | The firm will have to follow fair wage clause. |
| 334 | Sub-standard work will not be accepted. |
| 335 | No claim on account of fluctuation in prices due to any reason shall be considered. |
| 336 | The quantity can be increased or decreased as per actual requirement at site. |
| 337 | The conditional tenders shall not be accepted. |
| 338 | No premium will be allowed on M.R. Items, abatement, if any shall be applicable on all items including market rates. |
| 339 | The contractor has to employ qualified Engineer for the supervision of work at site. |
| 340 | Any error or omission in nomenclature or unit can be corrected at any stage. |
| 341 | The quality of material shall be strictly in accordance with the specification given in DNIT. |
| 342 | All the material shall be inspected by the Engineer-in-charge of work before installation at site. |
| 343 | The boards & M.S. boxes should be painted with 2 coats of superior quality paint after one coat of primer. |
| 344 | Separate colour of wires shall be used for phase and neutral so as to distinguish it for live conductor. |
| 345 | All the cable/ wire connections should be done through lugs / thimbles duly crimped with proper crimping tools & no extra payment shall be made on this account. |
| 346 | The department has reserve the right to issue any amendment to the work order as emergency demands or allow of altogether cancel the contract without assigning any reason. The department reserves the right to delete / add any item. |
| 347 | Discount offered by the firm should also be considered in deviation of items. |
| 348 | The extra/ substitute items will not be allowed against this work without the prior approval of the competent authority. |
| 349 | Security shall be deducted on each running/ Final bill of the firm as per CPWD / HPPWD works manual. |
| 350 | The firm shall ensure, the availability a licensed electrician/ supervisor/ qualified Engineer during the erection, testing and commissioning. |
| 351 | The contractor will have to produce invoice/ gate pass of the manufacturer for major items of material to be installed against S/E of work for genuine of the material. |
| 352 | The firm shall be quote the rates inclusive all the taxes/ GST whatever required and no extra payment shall be made in this respect. |
| 353 | The fittings/ material should be got inspected by the concerned AE with the representative of the firm and necessary certificate should be signed by the representative of the firm for its genuineness. |
| 354 | Any deviations to the clauses in the tender specifications must be clearly and separately indicated otherwise it shall be presumed that the offer is in line with requirements of tender. |
| 355 | Approved Makes. |
| 356 | Steel Conduit :-BEC,AKG,RKG, Precision Pipes. |
| 357 | PVC Conduit:-Anchor, AKG,RKG, Precision Pipes, Diplast. |
| 358 | FRLS Wires:-Havells, Finolex, RR Kabel, KEI, Polycab and Plaza. |
| 359 | Switches/ sockets(Premium):- Havells, Crabtree (Athena), Goldmedal (Air) (GIFa), Legrand (arteor), L&T (Entice). |
| 360 | Armoured / unarmoured Cables:- Univesal Cables, KEI Havells and Polycab. |
| 361 | Standared & Rules for lifts. |
| 362 | IS:17900( Part-I to Part-5.) |
| 363 | Indian Electricity Rules 1956. |
| 364 | Indian Electricity Act 2003. |
| 365 | H.P. Lift Act 2007. |
| 366 | H.P. Lift Rules 2009. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail