| 1 | Civil Works |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm |
| 3 | Dismantling old plaster of skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 4 | 15 mm Cement plaster on the rough side of single or half brick wall of mix:1:4 (1 Cement : 4 fine sand) |
| 5 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-inicharge:1:3:6 or richer mix (i/c equivalent design mix) |
| 6 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc complete 40mm thick with 20mm nominal size stone aggregate |
| 7 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in:Cement mortar 1:6 (1cement : 6 coarse sand) |
| 8 | Extra for brick work with common burnt clay brick / cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | KOTA STONE FLOORINGKota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement with base of cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished and Granite stone slab jet Black, Cheery Red, Elite Brown, Cat Eye or equivalent. |
| 11 | CERAMIC GLAZED TILESProviding and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 12 | Providing and fixing of ACP sheet of external grade 3 mm thickness with all aluminum tube frame, including fillings of gap with silicone complete in all respects including scaffolding etc. 181.60(Ground floor to Terrace). |
| 13 | Steel work welded in built up sections / framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 14 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 15 | C.G.I. SHEETS ROOFINGProviding corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gram/ m2 |
| 16 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1 mm thick. |
| 17 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC(Volatile Organic Compound) content less than 50 grams/liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 18 | Providing edge moulding to 18 mm / 16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in –charge.Granite Work. |
| 19 | Carriage of material by mechanical transport for loading / unloading complete |
| 20 | a) Sand for avg. lead 55 km |
| 21 | b) Aggregate for avg. lead 25 km |
| 22 | c) Bricks for avg. lead 60 km |
| 23 | Carriage of material by mechanical transport for loading / unloading complete Tarakote to site of work |
| 24 | a) Cement |
| 25 | b) Sand |
| 26 | c) Aggregate |
| 27 | d) Bricks |
| 28 | e) Steel |
| 29 | Electrical Work |
| 30 | WIRINGWiring for light point / fan point / exhaust fan point call being point with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. – Group – C |
| 31 | Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. |
| 32 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 33 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 34 | 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 35 | 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 36 | Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required |
| 37 | 20 mm Conduit |
| 38 | 25 mm Conduit |
| 39 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Make: - Legrand (Myrius) / Havell’s (Coral) |
| 40 | Modular Switch 5/6 Amp. |
| 41 | Modular Switch 15/16 Amp. |
| 42 | Modular Socket 3 pin 5/6 Amp. |
| 43 | Modular Socket 6 pin 15/16 Amp. |
| 44 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(Make: - Legrand (Myrius) / Havell’s (Coral) |
| 45 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(Make: - Legrand (Myrius) / Havell’s (Coral) |
| 46 | Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make: - Legrand (Myrius) / Havell’s (Coral) |
| 47 | 3 Module (10 mm x 75 mm) |
| 48 | 6 Module (200 mm x 75 mm) |
| 49 | 8 Module (125 mm x 125) |
| 50 | MCCB, MCB & DB’sSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator).(Make: - Havell’s / ABB / Schinder / Legrand / L&T) |
| 51 | 12-way, Double door |
| 52 | 16-way, Double door |
| 53 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: - Havell’s / ABB / Schinder / Legrand / L&T) |
| 54 | Single pole |
| 55 | Single Pole and neutral 40/63 Amp. |
| 56 | INSTALLATION, TESTING AND COMMISSIONING Supplying, installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc directly on ceiling / wall, including connections with 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required |
| 57 | LED Tube fitting 14-20 Watt 4 feet long. (Batten 4’) |
| 58 | LED recess panel 36 watt 2x2 |
| 59 | Supplying, Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
| 60 | Supplying, installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep (10”) |
| 61 | Supply, installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 510 mm sweep |
| 62 | Supply, Installation, testing and commissioning of wall mounting fan, including connection etc. as required. Please Enable Macros to View BoQ information |