| Sl. No. | Item Description |
| 1 | Civil Works2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil |
| 2 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for:4.3.1 Foundations, footings, bases for columns |
| 6 | 4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 7 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 8 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. |
| 9 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 14 | 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 15 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | 5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 17 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 20 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) |
| 23 | 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof andfire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).26.86.7 Frame size 65 x 150 mm |
| 24 | 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheathusk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistanceto spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full bodythreaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)26.87.1 30 mm thick |
| 25 | 9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete:9.92.1 125 mm |
| 26 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.4 150x10 mm |
| 27 | 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :9.96.2 250x16 mm |
| 28 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providingEPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications,drawings and direction of Engineer-in-charge complete. |
| 29 | 9.147E Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powdercoated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,including drilling of holes for fixing hardware's and drainage of water etc.After fixing frame the gap between frame and adjacent finished wallshall be filled with weather proof silicon sealent over backer rod ofrequired size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.9.147E.1 Two track two panels sliding window made of (big series)frame 67 x 50 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension. (Area of windowabove 2.50 sqm upto 4.00 sqm.) |
| 30 | 9.150 Providing and fixing zinc alloyed (white powder coated) touch lock foruPVC sliding window with necessary screws etc. complete. |
| 31 | 9.48 Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 32 | 10.3 Providing and fixing in position collapsible steel shutters with verticalchannels 20x10x2 mm and braced with flat iron diagonals 20x5 mmsize, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm diasteel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer. |
| 33 | 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gentlyand easily. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 34 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 35 | 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).11.20.1 Light shade pigment using white cement |
| 36 | 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.8.2.2 Granite stone slab colour black, Cherry/Ruby red8.2.2.1 Area of slab upto 0.50 sqm |
| 37 | 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.2 110 mm diameter |
| 38 | 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.12.42.1 Coupler12.42.1.2 110 mm |
| 39 | 12.42.5 Bend 87.5°12.42.5.2 110 mm bend |
| 40 | 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.12.43.2 110 mm |
| 41 | 13.4 12 mm cement plaster of mix :13.4.1 1:4 (1 cement: 4 coarse sand) |
| 42 | 13.5 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.1 1:4 (1 cement: 4 coarse sand) |
| 43 | 13.8 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :13.8.2 1:4 (1 cement: 4 fine sand) |
| 44 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 45 | 13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :13.43.1 Water thinnable cement primer |
| 46 | 13.83 Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.13.83.2 Two coats |
| 47 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 48 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 49 | 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side ofwaist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 50 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes |
| 51 | 9.128 Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvaturefor easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced withfibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight (Only plan area of chajjas shall be measured for making payment). |
| 52 | Sanitary Works17.1 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:17.1.1 White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 53 | 17.4 Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushingcistern |
| 54 | 17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern |
| 55 | 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 56 | 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 57 | 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 58 | 17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 59 | 17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 60 | 17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 61 | 17.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 62 | 17.36 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :17.36.2 100 mm dia pipe |
| 63 | 17.37 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :17.37.1 For 100 mm dia pipe |
| 64 | 17.38 Providing and fixing bend of required degree with access door, insertionrubber washer 3 mm thick, bolts and nuts complete.17.38.1 100 mm dia17.38.1.2 Sand cast iron S&S as per IS - 3989 |
| 65 | 17.61 Cutting chases in brick masonry walls for following diameter sandcast iron/centrifugally cast (spun) iron pipes and making good thesame with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6graded stone aggregate 12.5 mm nominal size), including necessaryplaster and pointing in cement mortar 1:4 (1 cement : 4 coarsesand) :17.61.1 100 mm dia |
| 66 | 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mmbreadth weighing not less than 45 gms |
| 67 | 17.73 Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittingsarrangement of approved quality and colour.17.73.2 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 68 | 17.74 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36mm height of approved quality and colour, weighing not less than300 gms. |
| 69 | Plumbing18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.Internal work - Exposed on wall18.7.1 15 mm nominal dia Pipes |
| 70 | 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and makinggood the same including testing of joints complete as per directionof Engineer in Charge.Concealed work, including cutting chases and making good the wallsetc.18.8.1 15 mm nominal dia Pipes |
| 71 | 18.8.2 20 mm nominal dia Pipes |
| 72 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.External work18.9.2 20 mm nominal dia Pipes metre |
| 73 | 18.9.3 25 mm nominal dia Pipes |
| 74 | 18.9.5 40 mm nominal dia Pipes |
| 75 | 18.9.9 100 mm nominal dia Pipes |
| 76 | 18.15 Providing and fixing brass bib cock of approved quality :18.15.1 15 mm nominal bore |
| 77 | 18.15.2 20 mm nominal bore |
| 78 | 18.16 Providing and fixing brass stop cock of approved quality :18.16.1 15 mm nominal bore |
| 79 | 18.16.2 20 mm nominal bore |
| 80 | 18.20 Providing and fixing brass ferrule with C.I. mouth cover includingboring and tapping the main :18.20.1 15 mm nominal bore |
| 81 | 18.51 Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms.18.51.1 15 mm nominal bore |
| 82 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 83 | Septic Tank2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil |
| 84 | 16.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 85 | 4.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 86 | 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 87 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for:4.3.1 Foundations, footings, bases for columns |
| 88 | 5.1 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 89 | 5.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 90 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 91 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 92 | 6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :6.12.1 Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 93 | 13.8 15 mm cement plaster on rough side of single or half brick wallfinished with a floating coat of neat ceme |
| 94 | 5.12 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 95 | 19.18 Supplying and fixing C.I. cover without frame for manholes :19.18.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 96 | 19.30 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :19.30.1.1 With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 97 | 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm drybrick honey comb shaft with bricks and S.W. drain pipe 100 mmdiameter, 1.8 m long complete as per standard design.19.32.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 98 | 17.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 99 | 17.36 Providing and filling the joints with spun yarn, cement slurry andcement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :17.36.2 100 mm dia pipe |
| 100 | Deep Tube Well23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer-in-charge, upto 90 metre depth below ground level.23.1.2 Rocky strata including Boulders23.1.2.1 300 mm dia |
| 101 | 23.3 Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, asper direction of Engineer -in-charge.23.3.2 150 mm nominal size dia |
| 102 | 23.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. |
| 103 | 23.12 Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well is fullydeveloped, measuring yield of well by \\"V\\" notch method or any otherapproved method, measuring static level & draw down etc. by stepdraw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, includinghire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge. |
| 104 | 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to thebottom of pipe assembly of tubewell as per IS:2800 (part I).23.15.2 150 mm dia |
| 105 | 23.4 Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs,conforming to IS: 12818, including hire & labour charges, fittings &accessories etc. all complete, for all depths, as per direction ofEngineer-in-charge.23.4.1 100 mm nominal size dia |
| 106 | 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (Newwork) :18.46.5 40 mm nominal bore |
| 107 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.18.9.5 40 mm nominal dia Pipes |
| 108 | 18.19 Providing and fixing gun metal non- return valve of approved quality(screwed end) :18.19.3 40 mm nominal bore18.19.3.2 Vertical |
| 109 | Site Development2.25(a) Excavating, supplying and filling of local earth (including royalty) bymechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. |
| 110 | Paver Block Approach2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared. |
| 111 | 16.78 Construction of granular sub-base by providing close graded Materialconforming to specifications, mixing in a mechanical mix plant atOMC, carriage of mixed material by tippers to work site, for all leads& lifts, spreading in uniform layers of specified thickness with motorgrader on prepared surface and compacting with vibratory power rollerto achieve the desired density, complete as per specifications anddirections of Engineer-in-Charge16.78.2 With material conforming to Grade-II (size range 53 mmto 0.075 mm ) having CBR Value-25 |
| 112 | 16.3 Supplying and stacking at site.16.3.3 53 mm to 22.4 mm size stone aggregate |
| 113 | 16.4 Laying, spreading and compacting stone aggregate of specified sizesto WBM specifications in uniform thickness, hand picking, rollingwith 3 wheeled road/vibratory roller 8-10 tonne capacity in stages toproper grade and camber, applying and brooming requisite type ofscreening / binding material to fill up interstices of coarse aggregate,watering and compacting to the required density . |
| 114 | 16.91 Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge.16.91.2 80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern. |
| 115 | 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.4.4.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 116 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for:4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 117 | 2.3 Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :2.3.1 All kinds of soil |
| 118 | Site Drain2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 119 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 120 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 121 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 122 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 123 | Horticulture/Landscaping5.16 Providing and Displaying Cyprus Golden 30 to 45 cm ht. well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots as per direction of the officer-in-charge. |
| 124 | 5.32 Providing and Displaying Furcaria Variegated hybrid well developed withfresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge. |
| 125 | 7.52 Providing and stacking of Magnolia grandiflora of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v |
| 126 | 7.72 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of theofficer-in-charge. |
| 127 | 3.16 Providing and displaying of Araucaria cookie having ht. 1.20 m to 1.35 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per directionof the officer-in-charge. |
| 128 | 4.4 Providing and Displaying Antirrhinum Hybrid dwarf variety, specimen (8-10) with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/Challi Pot and as per direction of the officer-in-charge. |
| 129 | 4.10 Providing and Displaying Calceolaria hybrid variety in full bloom well developed with fresh & healthy foliage in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge. |
| 130 | 4.28 Providing and Displaying Dianthus dwarf specimen 6-8 in a pot with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/Nand as per direction of the officer-in-charge. |
| 131 | Electrical Works1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 Group A |
| 132 | 1.10.2 Group B |
| 133 | 1.10.3 Group C |
| 134 | 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required. |
| 135 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required.1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 136 | 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 137 | 1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 138 | 1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 139 | 1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 140 | 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.1 5/6 A switch |
| 141 | 1.24.3 15/16 A switch |
| 142 | 1.24.4 3 pin 5/6 A socket outlet |
| 143 | 1.24.5 6 pin 15/16 A socket outlet |
| 144 | 1.24.8 Bell push |
| 145 | 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 146 | 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. 1.27.2 3 Module (100mmX75mm) |
| 147 | 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 148 | 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 149 | 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 150 | 1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 151 | 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 152 | 1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cableetc. as required. |
| 153 | 1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required. 1.50.1 Upto 450 mm sweep |
| 154 | 1.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.1.55.1 Group A |
| 155 | 1.55.2 Group B |
| 156 | 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.3.1 6 way , Double door |
| 157 | 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.4.1 4 way (4 + 12), Double door |
| 158 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.2.10.1 Single pole |
| 159 | 2.10.3 Double pole |
| 160 | 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.13.2 63 A |
| 161 | 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 162 | 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 163 | 5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 164 | 6.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 165 | 6.4 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by |
| 166 | 6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 167 | 6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 168 | 6.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chucknuts and spring washers etc. complete as required. |
| 169 | 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.7.1.1 Upto 35 sq. mm |
| 170 | 19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 171 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 36kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in an enclosure and necessary connection. 160Amp 4P MCCB |
| 172 | Enclosure for MCCB |
| 173 | Supplying and fixing double door Vertical TPN Distribution board for MCCB incomer with IP-43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing Jattachment. (Havells Make) (Up to 160A) 8 WAY VTPN DB |
| 174 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail ofl existing DBs and necessary connection 63A TP |
| 175 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary conncction.40A TP |
| 176 | Supplying of XLPE Al/Cu. armoured cables as below:4Cx16 sq. mm. XLPE AI Arm. Multistranded Cable |
| 177 | Supplying of XLPE Al/Cu. armoured cables as below:3&1/2 core 35 sq. mm. XLPE AI Arm. Multistranded Cable |
| 178 | Supplying and fixing of 25A AC Motor Starter along with GI Modular Box & Cover Plate |
| 179 | Supplying,Installation, Testing & Commissionng of following watts/type LED fitting with allaccessories and lamps mounting on ceiling surface /false ceiling not less than 100lumens/ watt, Min-50000 burning hours, LM79 report,THD less than 20% including making suitable cutting on false ceiling (where ever required), connection with 1.5 sq. mm. FRLS PVC insulated copper conductor single Core FR type cable as required.20 Watt Tube Light |
| 180 | 18 Watt Surface type Ceiling Light |
| 181 | 12 Watt LED Bulb |
| 182 | 60 Watt LED Street light |
| 183 | Exhaust Fan -250 mm dia |
| 184 | Supplying and fixing Air Conditioner, Voltas 1.5 ton Classic, Voltas SAC 185V CZR (R32) |
| 185 | Supplying and fixing 150-280 Volt, PEARL, MCU4150+ KVA Stabilizers (Microtec orequivalent) |
| 186 | Supplying, fittings and fixings of 2 H.P. Submerssible pump set (Water filled motor) asrequired and directed by the department. (Crompton/ Kirloskar/ Usha or equivalent) |
| 187 | Supplying including erection of 7.00 Mtr. G.I. Octagonal Pole with Single arm bracket oflrequired size along with fitting fixing, excavation work, foundation of bolts and nuts in R.C.C. work in 1:3:6 proportion of 1.00 Mtr. depth, Cement plastering and etc. complete with all necessary materials as required and specified by the Department. |
| 188 | 18KW Power Security deposit, supply Installation Energy Meter, Processing feescharge, etc. payable to APDCL. |
| 189 | Supplying,Installation, Testing & Commissionng of following rating Alluminium wound indoor / out door type transformer completey for supervision charge, labour charge. and making necessary arrangement for charging approval of the sub-necessary station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVAs tar rating up to 5 star, above 200KVA as per CEA guidelines for losses |along with LV enclosure. 25 KVA, BIS Level -1,11/0.433 KV, 3 Star, 3 Phase (Make : Power maker Unit Il /Equivallent) (All required materials for the Sub-Station will be measured & paid separately). |
| 190 | Supplying with erection of PSC pole 9.75 Mtrs.Length with PCC groutioong as required complete etc.as directed by the department. |
| 191 | Supplying with fitting and fixing of 11KV D.0.Fuse set 150 Amp assembly as required and specified by the department. |
| 192 | Supplying with foxong of 11KV Gang Operated AB Switch 150 Amp. As required and specified by the department. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail