| 1 | CIVILWORK |
| 2 | 2.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil |
| 3 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 4 | 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 5 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 6 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 8 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 9 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 10 | 5.9.16.1Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 11 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 12 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 13 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 14 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 15 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 16 | 50.6.7.2Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc. |
| 17 | 50.6.1.8Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etccomplete |
| 18 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 19 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost ofmaterials, labour charges etc complete |
| 20 | 13.44.1Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm) |
| 21 | 22.23.2Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 22 | 9.48.1Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to steel windows by welding |
| 23 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 24 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 25 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 26 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 27 | 11.19.2Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Medium shade pigment 50% white cement, 50 %ordinary cement |
| 28 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | OD293037/2025-2026Supplying and fixing steel pressed single panelled door of size 120*205cm with steelframes using superior quality GI sections made of tata steel |
| 30 | 5.30Add for plaster drip course / groove in plastered surface or moulding to R.C.C.projections. |
| 31 | 50.6.7.1Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc. |
| 32 | 51.19.ST2Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately)<br> 2. 15 to below 25 flush capacity |
| 33 | 13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 34 | 13.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture |
| 35 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 36 | 11.46.2Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mmthick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting thejoint with white cement & matching pigments etc. complete.Size of Tile600x600 mm |
| 37 | 11.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 38 | 16.68Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour andpattern over and including 50 mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 39 | 9.117.1Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wallthickness 2.0mm (±0.2 mm), corners of the door frame to be jointed withgalvanized brackets and stainless steel screws, joints mitred and plastic welded. Thehinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hingesfixed to the frame complete as per manufacturer's specification and direction ofEngineer-in-chargeExtruded section profile size 48x40 mm |
| 40 | 9.118.1Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles andrails mitred and joint at the corners by means of M.S. galvanised/plastic brackets ofsize 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The stylesof the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1mm (± 0.1 mm) wall thickness. The lock rail made up of 'H'section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm)wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S.'U' cleats. The shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm(± 0.1 mm) wall thickness. The panels filled vertically and tie bar at twoplaces by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturer's specification and direction ofEngineer-in-charge( For W.C. and bathroom door shutter). |
| 41 | OD320845/2025-2026Providing and fixing of acrylic name board with printed acrylic board .all work as perthe direction of engineer in charge |
| 42 | OD320863/2025-2026Supply and fixing of name board made of ACP panels supported over GI frame work |
| 43 | OD320865/2025-2026Providing and fixing granite engraved inauguration stone |
| 44 | PLUMBING AND SANITARY FITTINGS |
| 45 | 17.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling ofapproved municipal design complete, including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 46 | 17.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass wasteof standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brasspillar tap |
| 47 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 48 | 50.18.7.4.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall |
| 49 | 50.18.8.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 25 mm pipe 12 kgf/cm2 |
| 50 | 50.18.9.16.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall |
| 51 | 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Elbow |
| 52 | 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVCsolvent cement - 63x63x63 mm dia Tee |
| 53 | 50.18.9.20.6Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -63x63x63 mm dia Door Tee |
| 54 | 50.18.9.20.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia vent cowl |
| 55 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110 mm dia Elbow |
| 56 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVCsolvent cement 110x110x110 mm dia Tee |
| 57 | 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110x110x110 mm dia Door tee |
| 58 | 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -110 mm dia Vent cowl |
| 59 | 50.18.9.7.1Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling& testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 |
| 60 | 50.18.9.9.2Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 61 | 50.17.1.1Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etccomplete as per the direction of site Engineer-in-charge. |
| 62 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials andlabour charges etc complete as per the direction of site Engineer-in-charge. |
| 63 | 50.17.1.4Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc.complete as per the direction of site engineer-in-charge. |
| 64 | 17.7.9Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China SurgeonType wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps withelbow operated levers ISI marked |
| 65 | 17.60.2.2Providing and fixing trap of self cleansing design with screwed down or hingedgrating without vent arm complete, including cost of cutting and making good thewalls and floors:100 mm inlet and 75 mm outletSand Cast Iron S & S as per IS - 1729 |
| 66 | ELECTRICALWORKS |
| 67 | 90.2.2.1Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Single Control light point with6A, plate ceiling rose - Short point |
| 68 | 90.2.2.3Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Single control light pointwithout ceiling rose - Short point |
| 69 | 90.2.2.4Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Single control ceiling fan pointwith 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point |
| 70 | 90.1.1.1Supply and laying medium gauge PVC conduit of the following sizes conforming toIS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying& fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 71 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required20 mm |
| 72 | 90.2.2.6Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shallbe drawn and fixed along the periphery of the box using suitable ties, tie mounts etcas required. (Group B/ RoHS compliant modular accessories).Combined plug pointwith 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as thatof light points. |
| 73 | 90.3.18.2Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bentto shape / cut and welded to shape and fixing the same to wall / parapet using clampsas noted along with each size, painting with 2 coats of synthetic enamel paint over acoat of zinc chromate primer, making good the damages, colour washing etc asrequired.32 mm dia with HG company fabricated clamps |
| 74 | 90.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS orextending the original wiring and giving connection etc. as required.1200 mm1X20W LED Lamp with box type fixture |
| 75 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 76 | 90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED streetlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coatedhousing,acrylic cover complete with THD less than 10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Drivercompartment should be seperatly accessible for maintenance (LM 79&80certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer) |
| 77 | 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG) |
| 78 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 79 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 80 | 2.4.2Supplying and fixing following way, horizontal type three pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface / recess, complete with tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18),Double door |
| 81 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 82 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 83 | OD296285/2025-2026Supplying and fixing 40 A to 63 A, TPN MCB (C curve), 10 kA breaking capacity inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired. TPN |
| 84 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 85 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 86 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 87 | 9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) |
| 88 | 90.12.7.14Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3 core 10 sq mm with factory made clamp |
| 89 | 9.1.2Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 10 sq. mm (19mm) |
| 90 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x1.5 sq. mm |
| 91 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x2.5 sq. mm |
| 92 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet |
| 93 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 94 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For lightplugs to be used in non residential buildings). |
| 95 | OD294792/2025-2026Providing and fixing of service pipe (32 mm) |
| 96 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 97 | OD295310/2025-2026Supply and fixing 200mm plastic shade on existing batten/angle/pendant/bracketfittings as required |
| 98 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired. |
| 99 | OD311097/2025-2026Supply and fixing 9 w LED Bulb on existing lamp holder B22 |
| 100 | OD296188/2025-2026Supplying and fixing following way, PVC/Plastic MCB Enclosure on surface/ recess.(But without MCB/RCCB/Isolator) 4P enclosure 415 V |
| 101 | OD296189/2025-2026Supply & installation of dust and vermin proof, wall mounting, Sintax meter boxof following size suitable for fixing KSEB meter, fuse units etc. hinged doorconstruction for the front side with compartments if necessary, providing vision panelfor the meter compartment, knock out for cable entry. (GSMB-7450) (700*480*215) |
| 102 | OD296190/2025-2026Providing and fixing of 200mm plastic shade on existing batten/angle/pendant/bracketfittings as required |
| 103 | OD296235/2025-2026Supply ,installation of 63A Bakelite neutral links |
| 104 | OD311237/2025-2026Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to theearth plate |
| 105 | OD311238/2025-2026Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 106 | OD311262/2025-2026Supply ,installation of 63A Kit cat fuse unit made by porcelain/ ceramic Please Enable Macros to View BoQ information |