| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 3 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 4 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 5 | Providing and fixing 0.63mm thick prepained steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 mircons over 5 mircons primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 6 | Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete 0.63 mm thick with zinc coating not less than 275 gm/m² including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 7 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m² Ridges plain (500 - 600mm) metre including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 8 | Providing and fixing 10 liters vitreous china low level flushing cistern with a pair of C.I or mild steel brackets complete with flushing such as lead valve less syphon, 15 mm nominal size brass ball valve with polythene float CP brass handle unions and coupling for connections with inlet outlet and overflow pipes 40 mm dia CP flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 9 | Providing and Fixing facia tounged and grooved 1st class deodar wood. 25 mm thick including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 10 | Providing and fixing ACP sheet 3 mm thick panel in aluminium door, window, ventilator shutters and partition etc with PVC/neoprens gasket etc, complete as per the architectural drawings and the direction of Engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item) partition with 12 mm thick particle board bwp phenol bonded exterior/interior grade both sides including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 11 | P/F Aluminium door and window with all complete etc including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 12 | P/L Wooden Plank 40 mm thick 2nd Class D/Wood including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |