| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: BLOCK DEVELOPMENT OFFICER (B.P), PAPANASAM BLOCK IN THANJAVUR DISTRICT. Name of Work: THANJAVUR DISTRICT - MPLADP- 2025-2026. Part.1 Construction of OP Ward at Primary Health Center - Sithalakshmi Ammal Ramasamy Moopanar Memorial Building In Kabisthalam Panchayat Papanasam Block. Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. TEXT # Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE exclusive of GST in figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Part.1 Construction of OP Ward at Primary Health Center - Sithalakshmi Ammal Ramasamy Moopanar Memorial Building In Kabisthalam Panchayat |
| 3 | Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth,earth mixed with small sized boulders and hard gravelly soil as per specification etc.,complete for foundation. |
| 4 | Collection and supply of sand and filling in to the basement including cost and conveyance to the siteand all labour charges for filling as per standard speecifications., etc complete |
| 5 | Cement concrete 1:4:8 mix (one cement four sand and eight aggregate) using 40mm gauge hand broken granite stone jelly for foundation including dewatering if found ecessary and laid in layers of not more than 15 cm thick and compacted,etc., complete complying with standard specfication. |
| 6 | Reinforced Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and providing fixtures like fan clamps in the RCC floor or roof slabs wherever necessary and bearing surfaces of walls , sides and bottom of the slabs, beams etc., shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications. |
| 7 | Brick work in cement mortar 1:5 mix using country bricks 83/4\\"x41/4\\"x23/4\\" and conveyance of all materials to site and all labour charges etc complete.(Below Basement) |
| 8 | Brick work in cement mortar 1:5 mix using country bricks 83/4\\"x41/4\\"x23/4\\" and conveyance of all materials to site and all labour charges etc complete.(Abow Basement) |
| 9 | Supplying and erecting centering for sides and soffits of RCC slabs of plane surface like lintels, beams etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm x and B.G 10 stiffened with M.S angles of size 25mm x 25mm x '3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification. (Below Basement) |
| 10 | Supplying and erecting centering for sides and soffits of RCC slabs of plane surface like lintels, beams etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm x and B.G 10 stiffened with M.S angles of size 25mm x 25mm x '3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification. (Above Basement) |
| 11 | Suppling, fabricating and placing in position of MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors as per standard specification. |
| 12 | Plastering surfaces of RCC items such as slabs, beams, sunshades with cement mortar 1:3 mix using 10mm thick including packing, providing cement mortar beading for sunshades staircase ,steps, lands slabs etc.,as directed by departmental officers etc, complete complying with standard specifications. |
| 13 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work. |
| 14 | Plastering with cm 1:5 mix (one cement and five sand) to 12 mm thick including cost and conveyance of all materials in all floors etc.,as directed by departmental officers etc, complete complying with standard specifications. |
| 15 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 16 | Weathering course concrete using best quality broken brick jelly of size 20mm in pure slacked lime over the RCC roof slab in th proportion of brick jelly to lime being32:12.5 by the volume and laid over a single layer and consolidated to the required size |
| 17 | Finishing the top of the roof with one course of Machine PressedTiles of size 23x23x2 cm of approved quality laid in CEMENT MORTAR 1:3(One cement and three sand) 12 mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with the same water proofing compound mixed with cement mortar,red oxide, etc., complete complying with standard specification |
| 18 | Fabrication and supply of steel grill gate using structural steel in all aspects as dirercted |
| 19 | Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distember, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). For INNER WALL and Ceiling. |
| 20 | Painting two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification (including primer).For OUTER WALL Surface. |
| 21 | Painting two coats over new iron works using ready mixed enamel paint inculding cost and conveyance of materials and all labour charges etc.,complete |
| 22 | Wiring with 2 x 1.5 sq.mm. (22/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil) (SD 18) |
| 23 | Wiring with 2 x 1.5 sq.mm. (22/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil) (SD 18) |
| 24 | Supply and fixing of 1200 mm ( 48\\") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. (SD 110) |
| 25 | Wiring with 2 x 1.5 sq.mm. (22/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3pin non interlocking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point (SD 38) |
| 26 | Service Wire |
| 27 | Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD 125) |
| 28 | EB Main board (SD 145) |
| 29 | LED Tube Light |
| 30 | Providing and fixing of PVC rain water down fall pipe 110mm dia with necessary T W Clamps, Plug, Shoes, bend, Screws, nails etc., complete |
| 31 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \\"BB\\" for all works in this package} Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |