Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR Name of Work :- DNIT FOR CONSTRUCTION OF WORKING WOMEN HOSTEL AT GANDHI VANITA AASHRAM IN DISTRICT JALANDHAR (BALANCE WORK). Contract No: Civil Works Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | i) CIVIL WORKS:- |
| 3 | A-1) Construction of Ground Floor |
| 4 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with Stone Aggregate 40 mm Gauge and 100mm Fine sand filling using mechanical mixer for mixing of material |
| 5 | Screed of 50mm thick cement concrete 1:8:16 with Stone aggregate to be laid below the topping using mechanical mixer for mixing of material |
| 6 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 7 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry,including rubbing and polishing complete with : (iv) (b) Udaipur Green Marble Tiles of thickness 18mm to 20mm. Slabs sizes above 0.50 sqm |
| 8 | Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately) (iv) (b) Udaipur Green Marble Tiles of thickness 12mm to 15mm . Slabs sizes above 0.50 Sqm |
| 9 | Extra labour for projected nosing of stair case of any shape and design. |
| 10 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) (a)Size 600x600 mm |
| 11 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 12 | Extra Cost for using darker fast shade Vitrified or Rectified Tiles instead of lighter shades. |
| 13 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 14 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.Strip in Term of Rmt 100 mm Wide |
| 15 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 16 | Extra labour for projected nosing of stair case of any shape and design. |
| 17 | Brick jali with 22.86x11.43cm thick alternative layers laid in cement sand mortar 1:4 using 58 number bricks |
| 18 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours,shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 19 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. |
| 20 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge |
| 21 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 22 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 23 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 24 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 25 | Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating (P.T.M.T.) |
| 26 | 12.5 mm thick cement plaster 1:5 |
| 27 | 20mm thick cement plaster 1:5 in two coat work |
| 28 | 12.5 mm thick cement plaster 1:4 |
| 29 | 20mm thick cement plaster 1:4 in two coat work |
| 30 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 |
| 31 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 32 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 33 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 34 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 35 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 36 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 37 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 38 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 39 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 40 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999) a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv) 35mm thick |
| 41 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wallusing 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction ofengineer-in-charge |
| 42 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete -c) I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 43 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 44 | Providing and fixing of 30mm thick factory made Polyvinyl Chloride (PVC) door shutter (without chowkhat) made of styles and rails of a UPVC Plug profile section of size 30mm x 60mm and wall thickness 2mm ±0.2mm with inbuilt decorativemolding edging on one side. The styles and rails with plastic brackets of size75x220mm meter and welded at the corners. The- stiles of the shutterreinforced by inserting galvanized MS tube of size 25x20mm and 1mm ± 0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC Plug profile section ofsize 30mm x 100mm and 2mm±0.2mm wall thickness welded to the shutter stylewith a UPVC Plug profile section single panel of size not less than 620mm, havingoverall thickness of 20 mm and 1 mm±0.1 mm wall thickness with 20 mm panelbeading of suitable size /Glass(4mm thick plain glass)/louver section, louver frame of suitable size, as per manufactures specification and direction of Engineeringcharge. (For WC and bathroom door Shutter) |
| 45 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 46 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to requiredcolour or shade with nuts and screws etc. complete 300mm x 16mm |
| 47 | Providing & Fixing Fixed Beeding of 12 mm x 12 mm for Fixed Glass with ECO fixed gasket (EPDM) |
| 48 | Providing & fixing Glazing in Door, Window,ventilators & Partition etc.complete as per architectural drawings and the entire satisfaction of the Engineer-in-Charge (Cost of Gasket & Beading Shall be Paid as per Respective Item. (i) Float Glass panes of 5.5 mm thickness |
| 49 | Providing and fixing aluminum work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) (a) For fixed portion and chawkhats |
| 50 | Providing and fixing aluminum work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) (b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 51 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, inpaneling fixed in aluminum doors, windows shutters and partition frames withC.P. brass / stainless steel screws etc. complete as per architectural drawingsand directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 52 | Providing and fixing glazing in aluminum door, window, ventilator shutters andpartitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)Float glass panes of 5 mm thickness |
| 53 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors asrequired, embedding in floors and cover plates with brass pivot and single pieceMS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 54 | Supplying, fitting & fixing of Steel Almirahs at Site of Working Women Hostel at Jalandhar Specification:-(i). The Almirah should be made of prime quality deoxidized CRCA steel-panels 0.8 mm thick & front frame shelf 1.0 mm thick all steel body must be epoxy powder coated to the thickness of 60 microns (ii) 8 leaver locking arrangement with nickel finished die cast handle, there must be a glide screw for levelling purpose iii)III. Size: 4-10” (Width) x 7’00” (Height) x 2’00” (Depth) & 2’-5”(width)x 7’-00” (Height) x 2’00” (Depth) Deviation in dimension ±5% is negotiable) (As per Approved Drawing). |
| 55 | A-2) Construction of First Floor (Balance Part) |
| 56 | Screed of 50mm thick cement concrete 1:8:16 with Stone aggregate to be laid below the topping using mechanical mixer for mixing of material |
| 57 | Extra rate for First Floor |
| 58 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 59 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) (a)Size 600x600 mm |
| 60 | Extra rate for First Floor |
| 61 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 62 | Extra Cost for using darker fast shade Vitrified or Rectified Tiles instead of lighter shades. |
| 63 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 64 | Extra rate for First Floor |
| 65 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 66 | Extra rate for First Floor |
| 67 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 68 | Extra rate for First Floor |
| 69 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps |
| 70 | Extra rate for First Floor |
| 71 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 18mm to 20mmSlabs sizes above 0.50 sqm |
| 72 | Extra rate for First Floor |
| 73 | Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (iv) Udaipur Green Marble Tiles of thickness 12mm to 15mm(b) Slabs sizes above 0.50 Sqm |
| 74 | Extra rate for First Floor |
| 75 | Extra labour for projected nosing of stair case of any shape and design. |
| 76 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing thejoints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 77 | Extra rate for First Floor |
| 78 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours,shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 79 | Extra rate for First Floor |
| 80 | 12.5 mm thick cement plaster 1:5 |
| 81 | 20mm thick cement plaster 1:5 in two coat work |
| 82 | 12.5 mm thick cement plaster 1:4 |
| 83 | 20mm thick cement plaster 1:4 in two coat work |
| 84 | Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with afloating coat of neat cement and thick coat of Lime wash / P.O.P. on top of wallswhen dry for bearing of R.C.C. slabs & beams. |
| 85 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 |
| 86 | Extra rates for white washing, distempering, painting and decorative cement based paints etc for superstructure Where any single storey height exceeding 4 mtr in height for every additional height of 2 mtr or part thereof (External or Internal) |
| 87 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 88 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 89 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 90 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 91 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 92 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet,mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction ofengineer-in-charge. |
| 93 | Providing and fixing of 30mm thick factory made Polyvinyl Chloride (PVC) door shutter (without chowkhat) made of styles and rails of a UPVC Plug profile section of size 30mm x 60mm and wall thickness 2mm ±0.2mm with inbuilt decorative molding edging on one side. The styles and rails with plastic brackets of size 75x220mm meter and welded at the corners. The- stiles of the shutter reinforced by inserting galvanized MS tube of size 25x20mm and 1mm ± 0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC Plug profile section of size 30mm x 100mm and 2mm±0.2mm wall thickness welded to the shutter style with a UPVC Plug profile section single panel of size not less than 620mm, having overall thickness of 20 mm and 1 mm±0.1 mm wall thickness with 20 mm panel beading of suitable size /Glass(4mm thick plain glass)/louver section, louver frame of suitable size, as per manufactures specification and direction of Engineeringcharge. (For WC and bathroom door Shutter) |
| 94 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999)(a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-(iv) 35mm thick |
| 95 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) :(a) For fixed portion and chawkhats |
| 96 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) :(b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 97 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 98 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) |
| 99 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 100 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 101 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)(ii) For shutter area above 0.50 sqm |
| 102 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to requiredcolour or shade with nuts and screws etc. complete :A 300mm x 16mm |
| 103 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 104 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 105 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work |
| 106 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade |
| 107 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 108 | Supplying, fitting & fixing of Steel Almirahs at Site of Working Women Hostel at JalandharSpecification:-(i). The Almirah should be made of prime quality deoxidized CRCA steel-panels 0.8 mm thick & front frame shelf 1.0 mm thick all steel body must be epoxy powder coated to the thickness of 60 microns (ii) 8 leaver locking arrangement with nickel finished die cast handle, there must be a glide screw for levelling purpose iii)III. Size: 4-10” (Width) x 7’00” (Height) x 2’00” (Depth) & 2’-5”(width)x 7’-00” (Height) x 2’00” (Depth) Deviation in dimension ±5% is negotiable) (As per Approved Drawing). |
| 109 | A-3) Construction of Second Floor (Balance Part) |
| 110 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material |
| 111 | Extra rate for Second Floor |
| 112 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 113 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 114 | Extra rate for Second Floor |
| 115 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge.(a )Size 600x600 mm |
| 116 | Extra Cost for using darker fast shade Vitrified or Rectified Tiles instead of lighter shades. |
| 117 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 118 | Extra rate for Second Floor |
| 119 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 120 | Extra rate for Second Floor |
| 121 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 122 | Extra rate for Second Floor |
| 123 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 124 | Extra rate for Second Floor |
| 125 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :(iv) Udaipur Green Marble Tiles of thickness 18mm to 20mm(b) Slabs sizes above 0.50 sqm |
| 126 | Extra rate for Second Floor |
| 127 | Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately).(iv) Udaipur Green Marble Tiles of thickness 12mm to 15mm(b) Slabs sizes above 0.50 Sqm |
| 128 | Extra rate for Second Floor |
| 129 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 130 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 131 | Extra rate for Second Floor |
| 132 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 133 | Extra rate for Second Floor |
| 134 | 12.5 mm thick cement plaster 1:5 |
| 135 | 20mm thick cement plaster 1:5 in two coat work |
| 136 | 12.5 mm thick cement plaster 1:4 |
| 137 | 20mm thick cement plaster 1:4 in two coat work |
| 138 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 |
| 139 | Extra rates for white washing, distempering, painting and decorative cement based paints etc for superstructure Where any single storey height exceeding 4 mtr in height for every additional height of 2 mtr or part thereof (External or Internal) |
| 140 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 141 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 142 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 143 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 144 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 145 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 146 | Providing and fixing of 30mm thick factory made Polyvinyl Chloride (PVC) door shutter (without chowkhat) made of styles and rails of a UPVC Plug profile section of size 30mm x 60mm and wall thickness 2mm ±0.2mm with inbuilt decorative molding edging on one side. The styles and rails with plastic brackets of size 75x220mm meter and welded at the corners. The- stiles of the shutter reinforced by inserting galvanized MS tube of size 25x20mm and 1mm ± 0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC Plug profile section of size 30mm x 100mm and 2mm±0.2mm wall thickness welded to the shutter style with a UPVC Plug profile section single panel of size not less than 620mm, having overall thickness of 20 mm and 1 mm±0.1 mm wall thickness with 20 mm panel beading of suitable size /Glass(4mm thick plain glass)/louver section, louver frame of suitable size, as per manufactures specification and direction of Engineeringcharge. (For WC and bathroom doorShutter) |
| 147 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999) a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv) 35mm thick |
| 148 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) :(a) For fixed portion and chawkhats |
| 149 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) :(b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 150 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 151 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) (i) Float glass panes of 5 mm thickness |
| 152 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc.complete(c) I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 153 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 154 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)(ii) For shutter area above 0.50 sqm |
| 155 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to requiredcolour or shade with nuts and screws etc. complete : A 300mm x 16mm |
| 156 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 157 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 158 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 159 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 160 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 161 | Supplying, fitting & fixing of Steel Almirahs at Site of Working Women Hostel at Jalandhar Specification:-(i). The Almirah should be made of prime quality deoxidized CRCA steel-panels 0.8 mm thick & front frame shelf 1.0 mm thick all steel body must be epoxy powder coated to the thickness of 60 microns (ii) 8 leaver locking arrangement with nickel finished die cast handle, there must be a glide screw for levelling purpose iii)III. Size: 4-10” (Width) x 7’00” (Height) x 2’00” (Depth) & 2’-5”(width)x 7’-00” (Height) x 2’00” (Depth) Deviation in dimension ±5% is negotiable) (As per Approved Drawing). |
| 162 | A-4) Construction of Mumty & Terrace |
| 163 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 164 | Extra rate for Second Floor |
| 165 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 166 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in superstructure. |
| 167 | Extra rate for Second Floor |
| 168 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 169 | Extra rate for Second Floor |
| 170 | Centering and shuttering for sides and soffits of beam,beams, launching girders, bressumers, lintels. |
| 171 | Extra rate for Second Floor |
| 172 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 173 | Extra rate for Second Floor |
| 174 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge |
| 175 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.a) UPVC 110 mm bend |
| 176 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.a) UPVC 110 mm bend |
| 177 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 178 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 179 | Providing and fixing in position gratings 150mm x 150mm for gully trap.b) PVC grating (P.T.M.T.) |
| 180 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required. |
| 181 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 182 | Extra rate for Second Floor |
| 183 | Centring and shuttering for parapet, fascias and other similar items including edges. |
| 184 | Extra rate for Second Floor |
| 185 | A-5) Construction of Plinth Protection of Building |
| 186 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear fromthe edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres |
| 187 | Cement concrete 1:8:16 with stone ballast of size. 40 mm guage mixing by mechanical means using concrete mixer volumetric type |
| 188 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 189 | Earth filling under floors with surplus ordinary soil or soil containing gravel orkankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres |
| 190 | Earth filling under floors with surplus ordinary soil or soil containing gravel orkankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 191 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with Stone Aggregate 40 mm Gauge and 100mm Fine sand filling using mechanical mixer for mixing of material |
| 192 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 193 | 12.5 mm thick cement plaster 1:5 |
| 194 | A-6) Construction of Boundary Wall 10' High |
| 195 | Site clearance Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 196 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections,including all lifts and combined lead upto 30m and Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 197 | Earth filling under floors with surplus ordinary soil or soil containing gravel orkankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 198 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 199 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in foundation and plinth. |
| 200 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 201 | Reinforced cement concrete M-20 mechanically batch mixed using batch typeconcrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in superstructure. |
| 202 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 203 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 204 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 205 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 206 | 20mm thick cement plaster 1:4 in two coat work |
| 207 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 208 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 209 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 210 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 211 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 212 | 20mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at1.65Kg. Per Sqm laid hot and sanded Vertical |
| 213 | 20mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at1.65Kg. Per Sqm laid hot and sanded Horizontal |
| 214 | A-7) Construction of Outer Infrastructure |
| 215 | Clearing Grass and Removal of Rubbish Clearing grass and removal of rubbish up to a distance of 50 meters outside the periphery of the area as per technical clause 201 of MORT&H specifications |
| 216 | Construction of Embankment with Good Quality Earth obtained from Borrow pits Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications |
| 217 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 218 | Plain Cement Concrete Pavement Construction of unreinforced plain cementconcrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 219 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approvedsize and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge |
| 220 | ELECTRICAL WORK |
| 221 | D1- Providing Internal Electrical Installations: |
| 222 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: |
| 223 | Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 224 | Wiring fan point (without fan box ) |
| 225 | Wiring light point |
| 226 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 227 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 228 | Wiring call-bell point |
| 229 | Wiring 6 Amp. wall socket point |
| 230 | Wiring 6 Amp. Plug control comprising wall socket point |
| 231 | Wiring 16/20 amp. power plug control point |
| 232 | Wiring light point with double control switches. |
| 233 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 234 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 235 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 236 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 237 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 238 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 239 | Wiring TV socket point (one module) |
| 240 | Wiring Telephone socket point RJ11 (one module) |
| 241 | Wiring Networking socket point RJ45 (one module) |
| 242 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 243 | Overall size 1sq.mm (Un-sheathed) |
| 244 | Overall size 1.5sq.mm (Un-sheathed) |
| 245 | Overall size 2.5sq.mm (Un-sheathed) |
| 246 | Overall size 4sq.mm (Un-sheathed) |
| 247 | Overall size 6sq.mm (Un-sheathed) |
| 248 | Overall size 10sq.mm (Un-sheathed) |
| 249 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 250 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose) |
| 251 | Overall size 120sq.mm (3½ Core) Un-armoured (Loose) |
| 252 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 253 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 254 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 255 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 256 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 257 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 258 | PVC flexible pipe 40mm dia. |
| 259 | G.I. EARTHING :- Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). |
| 260 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length) |
| 261 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- |
| 262 | Additional length G.I. wire 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 263 | COPPER EARTHING (Upto 14 metre in Length): |
| 264 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 265 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 266 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 267 | Additional Length 20mm x 3mm thick Copper Tape |
| 268 | MCB'S & MCB DISTRIBUTION BOARDS: |
| 269 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 270 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 271 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 272 | MCB Triple Pole 50, 63amp. (10kA, Curve-C) |
| 273 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 274 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 275 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 276 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 277 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 278 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 279 | TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp) |
| 280 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 281 | Cable End Box for TPN 4 Way |
| 282 | Cable End Box for TPN 6 Way |
| 283 | MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 284 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 285 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 286 | Double Walled Corrugated (DWC) HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 287 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 288 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 289 | Supply and erection of BEE 3 star AC Ceiling Fan 1200mm (48\\") with double ball bearing, copper wound, full aluminium body 3Nos of blades. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. The fan should conform to Technical Specifications attached. |
| 290 | Supply and Erection of Wall fan plastic body 400mm 16\\" including flexiible wire and petty material etc. for connection and testing complete in all respects as desired by the Engineer in charge of work at site. |
| 291 | Supply and erection of 12\\" Heavy Duty Exhaust fan (HDEF) (300mm-900RPM) Single Phase of ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections and louver shutter complete in all respects as appd. and desired by the Engineer in-charge at site |
| 292 | D2- Providing Campus Lighting/ Security Lighting |
| 293 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 294 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 295 | Overall size 1.5sq.mm (Un-sheathed) |
| 296 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 297 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 298 | Overall size 10sq.mm (4Core) Un-armoured (Loose) |
| 299 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 300 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 301 | Overall size 10sq.mm (2Core) Armoured (On-Surface) |
| 302 | G.I. EARTHING: |
| 303 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 304 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 305 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 306 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 307 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 308 | MINIATURE CIRCUIT BREAKERS: |
| 309 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 310 | MCB Double Pole 6-32amp. (10kA, Curve-C) |
| 311 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 312 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 313 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 314 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 315 | MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 316 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 317 | MS SHEET ENCLOSURE FOR MCCB's: |
| 318 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 319 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 320 | GI PIPE POLES & BRACKETS:SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE: |
| 321 | Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½\\" x 1½\\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:- |
| 322 | Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m) |
| 323 | 3-STEPPED STEEL TUBULAR POLE: |
| 324 | Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:- |
| 325 | Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia. |
| 326 | CEMENT CONCRETE MUFFS: |
| 327 | Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The SMC Junction Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 328 | Cement Concrete Muff of Overall Size 450mm dia., 80cm Long |
| 329 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 330 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 331 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 332 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 333 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 334 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: CUBICAL PEDESTAL: |
| 335 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 336 | Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm |
| 337 | Supply, Erection of LED Street Light 45w (including LED driver) in aluminium pressure die cast housing with toughned glass cover (IP66 Protection) having efficiency of LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270volt, input frequency 50Hz + 3% complete along with erection of the same with connections, testing etc. fitting should install on existing pole complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and Specification of the LED fitting should be as approved by O/o Advisor(Technical), Govt. of Punjab vide Letter no. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 338 | Supply and erection of LED Flood Light 120watt (including LED driver),Pressure Die cast aluminium with efficacy of LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 339 | Supply and erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 340 | TIMER: |
| 341 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 342 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 343 | D3-Supply, Installation, Testing and Commissioning of 1 Nos. Lift of 13 Passengers Machine Room Less. |
| 344 | Supply, Installation, Testing and Commissioning of 1 Nos. Lift of 13 Passengers Machine Room Less.Type and Capacity: Approximately 884 Kg. 13 Passengers\\"Speed: 1.0 Meter per second\\"Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.\\"Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way*Travel: Approximately 8 meterServing: 3 Floors_3 Stops_3 Openings_3 Levels (All on the same side)\\"Hoist way Required: 2600mm (Wide) x 1900mm (Deep) Clear dimensions\\"Headroom Height (HR): 5000 mm beyond finished floor level of last landing*Pit Depth: 1600mm below the finish floor level of first landing\\"Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meterCar Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof).Car Entrance: Center Opening Automatic Doors with vision panel (40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high)\\"Door operation: Automatic DC Door operation with adjustable door opening and closing timings\\"Control: Simplex full selective collective control with and without attentdent\\"Operation: Automatic*Power Supply: 415 Volts, 3-phase, 50Hz Alternating Current*Flooring: Floor Skid - Resistant as per standard*Fan: Blower Fan in Car for ventilation with Auto cut off\\"Lighting: LED for Car Lighting\\"Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings*Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH, Side RH &Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level\\"Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level\\"All std. Govt. features. |
| 345 | Other Features1. Battery operated emergency light with rechargeable battery2. Battery operated emergency alarm with rechargeable battery3. Adjustable Guide shoes4. Micro movement LED based buttons5. Door Open and Close buttons6. Emergency Intercom provided inside the elevator7. Emergency Intercom usable without the voice communication8. Load weighing device with overload bypass feature and Overload function with Audio Visual indication9. Steel items, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection 11. Call registration12. Audio & Video System installted in the lift indicating arrival at a floor13. Manual break lever 14. Additional car gate lock15. Automatic break testing infrared safety curten16. Braille Buttons (Inside and outside) with Braille instructions for the communication system17. Kick plate/Skirting18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance/exit is either Open or Close19. Car Operating Panel20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel21. Phase two device fire man drive 22. Fire Man switch at main lobby23. Car false ceiling in stainless steel24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.30. The floor of the lift car should be slip resistant and have similar frictional qualities to the floor of the lift landing to decrease the risk of stumbling.31. The use of visually and acaustically reflection wall surface should be minimum with in the lift car as visual reflection can cause discomfort and effect the visula ability of people with impairements. |
| 346 | COPPER EARTHING (Upto 14 metre in Length): |
| 347 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 348 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 349 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 350 | Additional Length 20mm x 3mm thick Copper Tape |
| 351 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 352 | Overall size 6sq.mm (Un-sheathed) |
| 353 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 354 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 355 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 356 | MINIATURE CIRCUIT BREAKERS: |
| 357 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 358 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 359 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 360 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 361 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 362 | SP&N Double Door Distribution Board 8 way each |
| 363 | Supply and erection of 12\\" Heavy Duty Exhaust fan (HDEF) (300mm-900RPM) Single Phase of ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections and louver shutter complete in all respects as appd. and desired by the Engineer in-charge at site |
| 364 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 365 | D4- CCTV |
| 366 | Supply, erection, testing & commissioning of IP Bullet/Dome Vari Focal CAMERA 5MP IP Camera STQC Approved with Audio Input Support and following features Resolution - 5 MP (2592 x 1944), Sensor Type and Size-1/2.8\\" SONY - CMOS 5MP Active Pixel Progressive Scan, Back Illuminated Image sensor, Minimum Illumination Color - 0.01 Lux @F1.2 (AGC ON), Monochrome - 0 Lux, Focal Length 2.8mm – 12mm Focus Range - 0.3m to infinity, Field of View (FOV) HFOV – 106 - 32°,VFOV- 73-23,DFOV 142-39, Focus-Automatic focus Aperture (F#) F 1.6 - F 2.8,Iris Type Motorized varifocal, IR Range Up to 50m, IR Led Wavelength 850nm, IR Switching Auto/ Manual , Audio IN 1,Audio OUT 1,Two-way Audio Supported, Audio Compression G.726 and G.711μ Alarm In Yes, Alarm Out Yes, SD Card Up to 512GB, Camera Adjustment Angle Pan: 0° to 360° Tilt: 0° to 90° Rotate: 0° to 360°,No of Stream Profiles 4, Stream Profiles- Profile 1: Mainstream - 2592*1944@ 30fps (H.265/H.264), Profile 2: Sub stream - D1@30fps (H.265/ H.264), Profile 3: MJPEG - 2048*1536@8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4:1920*1080@30fps (H.265/H.264/MJPEG) Available Resolutions 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, VGA, 2CIF, CIF, Max Resolution 2592 x 1944, Bitrate 128 kbps-16Mbps, Bitrate Type CBR, VBR, Video Compression H.265, H.264, MJPEG, Frame Rate 1-30fps, Shutter Speed 1/15s -1/100000s,Adaptive Streaming Yes, ONVIF Profiles S, G, and T, Edge Recording Yes, Alarm Recording Pre and Post, Motion Recording Yes, Time Triggered Yes, Video Parameters Snapshot, Region of Interest (ROI), BLC, HLC, Day/Night Settings, Privacy Masks 8, WDR True WDR (120dB), SNR >70dB Image Enhancement Saturation/ Contrast/ Sharpness/Brightness/Auto Exposure/HVS- Forensics/ Smart IR DNR 2D &3D Video Analytics, Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Audio Exception, IP Conflict Yes, Network Disconnect Yes, Storage Full Yes, Upload Image SD, NAS, SFTP, Upload Clip SD, NAS, SFTP Notifications E-mail, SMS, TCP, Supported protocols, TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, Dyn DNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour, Web Viewer Supported in IE 8.0-11.0, Firefox 15.0-47.0, Chrome 20.0-54.0, Browser IE, Chrome, Mozilla, CYBER SECURITY as per ISO/IEC 27402-Secure boot Yes, Signed firmware Yes, Data Encryption All data, including sensitive data, is encrypted with AES 256 and RSA 2048, IP Address Filtering Yes, HTTPs Streaming Yes, using TLS 1.2, Edge Data Encryption Yes, Network Authentication Yes,802.1x Network authentication, Secure Firmware Upgrade Yes, Anti-roll back firmware Yes, Web login Password protection Yes, Unused debug interface protection Yes, Power Supply 12V (DC); 802.3af (PoE), Power Consumption Approximately 7W, Operating Humidity Less than 95% RH (non- condensing), Operating Temperature -30°C to 60°C,Storage NAS, SD Card, BIS, CE, IP67, FCC Part- 15 Subpart – B, ONVIF S, G & T, IK10, UL, NEMA 4X* complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 367 | Supply, erection, testing & commissioning of OF 32 Channel IP INPUT 12MP NVR 4K with 4 SATA having following features:- Up to 32 Channel Input, 4 Sata Interfaces, Up To 12TB each, H.265/H.264 Video Formats, 1 HDMI Port , USB2.0*1, USB2.0*2 Support,2×RJ45 Self-adaptive 10/100/1000 Mbps Network Interfaces, Supports live view, storage and playback of the connected camera at up to 12MP resolution, Connectable to the Third Party Network Cameras, Incoming Bandwidth -200M, Outgoing Bandwidth- 200M, Recording Resolution-12 MP/8 MP/5 MP/4 MP/3 MP/1080p/720p, Recording Compression, Audio: G.711a,G.711u, Video : H.264/H.265, H.264+/H.265+, Speed -12MP:30fps 8MP:120fps 4MP:240fps 2MP:480fps, Playback- 1080P:480fps Max 16CH, WEB -IE10/11, SafariV12.1 above, Firefox V.52 above, Google chrome V.57 above, Edge V.79 above, Protocols-TCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, UPnP, HTTP, HTTPS, API -Onvif (profile S/G/T HDMI -1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 2560*1440(2K), 3840*2160(4K)) 0 /EDID) Async out, Ethernet-2 RJ45 100/1000 Base-T USB USB2.0*1(front), USB 2.0 *1 USB 2.0 *1 (rear), Audio-1 in / 1 out, E-sata-1 ,HDD 4, each up to 12TB, OSD Language English, Input Voltage/ Current 12V/5A, Power consumption (excluding hard disk) -8W Operating Temperature/Humidity-Temperature :- 10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 368 | Supply, erection, testing & commissioning of 6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB- Scheme, TUV, UL for NVR recording and playbac complete in all respects as approved and desired by the Engineer in-charge at site. |
| 369 | Supply, erection, testing & commissioning of 08 Port POE 60+ Watts L2 managed 10/100/1000 Mbps Data switch with 2 RJ45/SFP 1G Ports • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASET Gigabit Ethernet• IEEE 802.3az Energy- Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay autonegotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 50 Gbps Data Transfer Rates • Gigabit Ethernet • 2000 Mbps (full- duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af • IEEE 802.3at PoE-capable Ports • Ports 1 to 2 Power 60W • 60+ W (30 W max. per PoE port). CPU RAM 256MB or above Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F) complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 370 | Supply, erection, testing & commissioning of Smart 55” LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) Samsung TV Plus App USB Cloning, 2 No. Of HDMI Port,2 no USB Port .complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 371 | Supply, Installation, Testing & Commissioning of 10 meter long superior quality 4K HDMI Cable having speed upto 10gbps support all types of HDMI Devices complete in all respects as approved and desired by the Engineer in-charge at site. |
| 372 | Supply, erection, testing & commissioning of RJ-45 Male connector . complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 373 | Supply, erection, testing & commissioning of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 374 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 375 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: |
| 376 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 377 | CAT 6 LAN cable |
| 378 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 379 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 380 | D5-PA System |
| 381 | Supply & erection of 23” Gooseneck Microphone with stand having on/off switch, frequency response 20- 18,000Hz, Sensitivity 7.5mV/Pa, Power Source 1.5V- 9VDC, Impedance 1000Ω with 10 meter long Twin core shielded low noise cable with XLR connector & 6.3mm phone jack, heavy duty metal base with anti skid feet, Built in cell housing, 2 no. AA size cell. |
| 382 | Supply & erection of Advanced PA Amplifier with Built-in Digital Player System comprises of following features:- 220V AC & 12V DC operation ,125 watt PA Amplifier, 5 Mic & 2 Aux input MP3 Recorder & player USB & Card Reader Remote control Intelligent sound reinforcement Speaker output @ 4Ω 8 Ω & 70V /100V Active Bass & Treble Control LED Display with Multimedia control 2.5” built-in speaker to programme check 1 Year onsite warranty. |
| 383 | Supply & erection of wall mounting column speaker 15W/100V, frequency response 150-15,000Hz, 23 Watt max, SPL at 1kHz-91.5db/1W/1M, Power Tap 15/10/5/2.5Watt. |
| 384 | Supply & erection superior quality 2 core copperconductor transparent Speaker wire 1 sqmm. |
| 385 | Supply, erection, testing & commissioning of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 386 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 387 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 388 | D6- Providing Manually Operated Fire Alarms System Including Exit Signage : |
| 389 | Supply Installation, Testing & Commissioning of Conventional 2 Zone Fire Alarm Control Panel Fully confirms IS 2189 with 2 Nos. of 12v,7Ah batteries and with built in charger,LCD display and LED indication for zonewise Fire, Open, Short,Zone isolation,Mains on,Battery Low, Fuse blown, AC Fail.The enclosure of shouls be fire proof and constructed by CRCA sheet with powder coated finish. The 20mm knock out are given for cable entry at the top of the cabinet complete in all respects as approved and desired by the Engineer in-charge at site. |
| 390 | Supply,installation, testing & Commissioning of Red Conventional Call Point with LED Resistor 470 OHM Flush Mounting Flexi Element complete in all respects as approved and desired by the Engineer in-charge at site. |
| 391 | Supply, installation, testing & Commissioning of Red Mini Horn Red UL certified India complete in all respects as approved and desired by the Engineer in-charge at site. |
| 392 | Supply, installation, testing & Commissioning of ExiLED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site. |
| 393 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 394 | PVC INSULATED FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 395 | Overall size 1.5sq.mm (Un-sheathed) |
| 396 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 397 | Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed |
| 398 | D7-Providing Advance Lightning Protection System: |
| 399 | Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning ProtectionComplete with Lightning Air Terminal. The System should be corrosion resistant stainless steelchrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As perNF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec)=100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shalloffer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof topand center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as athunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering devicegenerates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4 .Complete in all respects as per satisfcation of the Engineer incharge at site. |
| 400 | Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.Complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 401 | Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable(electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level.Complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 402 | Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor.Complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 403 | Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr.Complete in all respects as per satisfcation of the Engineer incharge at site. |
| 404 | Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge. |
| 405 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 406 | Overall size 70sq.mm (Un-sheathed) (Conductor connected the air terminal to earthing) |
| 407 | D7-Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant |
| 408 | Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant 24KW (i.e connected to utility grid) of +500 watt including required quantities of SPV modules (High power density Perc Bifacial Monocrytalline based) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Required Earthing (i.e. 2 Nos.GI Strip Earthing for GI Structure, 2Nos. GI Strip Earthing for String Inverter, AC & DC Distribution System), ESE Stroke master (As per NFC 17 102 Standard with suitable radius of protection) & 3 Nos. chemical earthing with copper bonded rods along with high rise GPSP structure (Rated Wind Speed 170Kph) including mounting height upto 8 feet Complete with transportaion, fabrication, labour & Civil Work.Features:- 1. Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 I & II, IS/ IEC 61701 & IS/IEC 14286 2. Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure : 25 Years Service Life with AMC & Certified under IS 2062:20114. Complete Plant Insurance for the period of 5 Years5. Annual Maintenance Contarct for the period of 10 Years The Work will got done from approved MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) Contractors/ PWD enlisted contractor, subject to condition that he will get work alone from PEDA/MNRE approved contractor.The rates are inclusive of bi- directional meter testing charge, PSPCL connection charges, unidirectional meter cost and all type of taxes including G.S.T. |
| 409 | PUBLIC HEALTH WORK |
| 410 | Sub Head-1 Internal Sewerage System |
| 411 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 412 | Single Socket Type B |
| 413 | 110mm o/d SWR UPVC pipe lines laid complete |
| 414 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 415 | qty as per Table Atached |
| 416 | For 110mm o/d pipes |
| 417 | Elbow 90 Degree (All side socketed) |
| 418 | Vent Cowls |
| 419 | Coupler |
| 420 | P Trap/Floor Trap 110mm x 110mm |
| 421 | Single Y-Junction with door |
| 422 | Single Tee |
| 423 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 424 | 110mm o/d |
| 425 | Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. |
| 426 | With 100mm x 75mm i/d Floor Trap (weighing 5.8 Kg) |
| 427 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.. |
| 428 | M.S. Holder bats clamps for 100mm i/d H.C.I. pipes |
| 429 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm |
| 430 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 431 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming toI.S.I complete as per standard design. |
| 432 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 433 | Extra for every 0.30 metre depth of inspection chamber. |
| 434 | 600mm x 900mm inside |
| 435 | Cement concrete 1:2:4 |
| 436 | a With stone ballast or shingle |
| 437 | mixing by mechanical means using concrete mixer volumetric type |
| 438 | Sub Head-1 Estate Sewerage System |
| 439 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 440 | 110mm O/D Foe IC to Manhole Connection |
| 441 | 160mm o/d pipe |
| 442 | 200mm i/d pipe |
| 443 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work |
| 444 | For 200mm O/D pipe |
| 445 | For 160mm O/D pipe |
| 446 | Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer- in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. |
| 447 | For depths not exceeding 3.0 metre B.G.L.For all classes of soil except rocky |
| 448 | For Sewer Line 200 mm dia |
| 449 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 450 | Inside size 75x120 cm with depth 120 cm deep |
| 451 | Inside size 90x150 cm with depth 120 cm deep |
| 452 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda |
| 453 | Sewer connections upto 300 mm id |
| 454 | Sub Head-1 Internal Water Supply System |
| 455 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 456 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 457 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 458 | CPVC SDR 11 Pipe & fitting 25mmo/d |
| 459 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 460 | CPVC SDR 11 Pipe & fitting 40mm o/d |
| 461 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75mm x 75mm |
| 462 | qty same as CPVC P 15mm +20mm +25 mm +32 mm |
| 463 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 464 | Through wall 11.43 cm thick |
| 465 | Through wall 22.86 cm thick |
| 466 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 467 | 20mm i/d Brass Ball valves |
| 468 | 25mm i/d Brass Ball valves |
| 469 | 32mm i/d Brass Ball valves |
| 470 | 40mm i/d Brass Ball valves |
| 471 | 50mm i/d Brass Ball valves |
| 472 | Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects. |
| 473 | Providing and fixing in position G.I tank nipple of approved make in pvc water storage tank complete |
| 474 | 25mm i/d |
| 475 | 32mm i/d |
| 476 | 40mm i/d |
| 477 | Providing and fixing jointing G.I Union coupling as per IS 1879 in GI pipe lines complete. |
| 478 | 25mm i/d |
| 479 | 32mm i/d |
| 480 | 40mm i/d |
| 481 | Sub Head-2 Estate Water Supply |
| 482 | Providing & fixing PVC Pipes & Specials 10Kg / cm2 including cost of earth work in excavation & back filing complete as per analysis A-14 A (By Manually) |
| 483 | For 90 mm o/d PVC Pipe |
| 484 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI |
| 485 | 80 mm i/d Sluice Valves Flanged |
| 486 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department each of size 0.6m x 0.6m |
| 487 | Sub Work - 3 Sanitary Installation & Water Cooler |
| 488 | Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 489 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 490 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With C.P. Brass nut |
| 491 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 492 | Size 550 mm x 400 mm x 815 mm |
| 493 | Providing and fixing in position SS Grab BarGrade 304 of approved make (to theapproval of the Engineer-in-charge) fixed into wall with brass screws complete in allrespect. |
| 494 | Foldable U Type 762mm long |
| 495 | 35mm dia 1200mm (48”) long |
| 496 | 35mm dia 600mm (24”) long |
| 497 | Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect. |
| 498 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 499 | Vitreous chinaware standard white pedestal for wash hand basin |
| 500 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.(e) PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut |
| 501 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.. |
| 502 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 503 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 504 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 505 | C.P. brass Bib cock foam flow without flange |
| 506 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 507 | C.P.brass 15mm Concealed stop cock with flange. |
| 508 | C.P.brass 15mm Angle valve without flange |
| 509 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 510 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. i) C.P. Brass extension piece, 25mm long to 50mm long |
| 511 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)(a) Size 600mmx450mm |
| 512 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.(i) Triple Layer Tanks |
| 513 | 2000 ltr Capacity |
| 514 | Providing and fixing in position automatic brass Ball Cock in tanks.25mm i/d B Brass Ball Cock with rod and Plastic Ball |
| 515 | Construction of Plateform for 2000 ltr capacity complete as per specification & as desired by Enginer-in-charge |
| 516 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 517 | Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling |
| 518 | Double bowl Sink without drainboard Overall size 1114 x 490 mmwith bowl size 460x385x200mmincluding waste coupling |
| 519 | Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineer- in-charge) complete in all respect. |
| 520 | Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 521 | Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer- in-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect. |
| 522 | C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm |
| 523 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 524 | C.P. brass towel Rails size 15mm dia 610mm long |
| 525 | C.P brass towel ring |
| 526 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 527 | Providing and fixing in postion storage type automatic electric water heater pressure / non pressure type thermostatically controlled, single phase, vertical wall mounted of approved make (to the approval of Engineer-in charge) with thermostats, inner container of stainless steel complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. |
| 528 | 25 litre capacity water heater |
| 529 | Supply & installation of self contained drinking water cooler with (Non CFC Refrigerant) energy efficient compressor of make USHA, Model No. SRA 40 80 G, cooling capacity Ltrs/hr. 40, storage type capacity 80 Ltrs. Stainless Steel Tank including installation etc. Complete in all respect as approved and desired by the Engineer-in-charge at site.Make...USHA / Blue Star / Bajaj – or its equivalent. |
| 530 | AUTOMATIC VOLTAGE STABLIZER: |
| 531 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 532 | Automatic Voltage Stablizer 2 KVA |
| 533 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge )including carriage and fixing in position complete in all respect. |
| 534 | Sub Work-4 Flooring and Wall Tile |
| 535 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of cement) |
| 536 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 537 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 538 | Area same as screed of all the floors |
| 539 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 540 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 541 | Coloured Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 542 | Roof Top Rain Water harvesting System |
| 543 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. |
| 544 | 200mm o/d pipe of 4 Kgf. / sqcm |
| 545 | For Rain water Line 160mm i/d PVC pipe 6 Kgf. / sqcmFor connection of Road gully and sewer @ 7mtr. Each per road gully |
| 546 | Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer- in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. |
| 547 | For depths not exceeding 3.0 metre but not excluding 4.5 m B.G.L.For all classes of soil except rocky |
| 548 | Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge |
| 549 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49) complete and to the requirement of the |
| 550 | Size 610mm x 457mm x 800mmNo. of Road Gully @ 15mtr. C/c Distance |
| 551 | Construction of Rain water recharge well 3.00mtr dia with working depth 2.50 mtr dia consisting of drilling bore 300mm dia 100mtr, supplying and lowering pvc perforated housing pipe 150 mm dia 55mtr sorrunded with filtermedia , PVC 150mm i/d 4mtr duly plugged from top with bail plug, fixing MS clamp, MS socket, Well size 3.00 mtr internal dia, 6 mtr deep constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 3 Layers, 2Nos RCC Man hole cover conneted with collecting chamber size 1.5mtr x 3mtr x 2.5 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge . (Note :- Payment will be made as per CSR Based Rates Plus/Minus Quoted rates). |
| 552 | Sub Work 3 Fire Fighting Arrangements |
| 553 | Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.4.5kg capacity |
| 554 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity |
| 555 | SITC of MS PipeProviding, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 556 | 80mm internal diameter |
| 557 | Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank). |
| 558 | two Way inlet connection |
| 559 | Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect. |
| 560 | Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 561 | XLPE INSULATED ARMOURED CABLES (UNDERGROUND):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- |
| 562 | Overall size 16sq.mm (3Core) Armoured (Underground) |
| 563 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks |
| 564 | 10000 ltr Capacity |
| 565 | Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball |
| 566 | Brass Ball Cock with rod and Plastic Ball 32mm i/d |
| 567 | Providing and fixing in position cPVC. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 568 | 63mm i/d Cpvc Tank Nipple |
| 569 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge |
| 570 | For 10000 ltr Water Tank |
| 571 | Supply Installation, testing & commissioning of pump having 65mm suction, 50mm delivery, CI casing, bronze impeller and C-40 shaft with gland packed arrangement coupled on common base plate to Make Kirloskar/ABB/CGL (at our option) 7.5 kw/10HP, 2935RPM TEFC sq cage induction motor supply confirming to through suitable flexible coupling The pump set is suitable for following duties the pump is designed following duties total head 35 mtr flow 450 LPM including cost of Electrical control panel complete in all respect as per specifications. Total in Figures 50745124.18 36351823.19 INR Three Crore Sixty Three Lakh Fifty One Thousand Eight Hundred & Twenty Three and Paise Nineteen Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail