| 1 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material. Hard Roack blasting prohibited and their intermediate classification of soils including, dewatering wherever required, setting of to the required lines, levels as shown on the drawing and directed by the Engineer -in-charge at site, according to the HP.PWD. specification of 1990 (one thousand nine hundred ninety) volume-I (one) and sorting out useful and unuseful material and transportation of the unuseful material for disposing at approved dumping site Bharyal. including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools equipments and safety measures and incidentals necessary to complete the work by mechanical means and labour (if required).All useful material such as stones, shingles aggregate and slates shall be properly stacked at site to the maximum possible extent in all leads and lifts through all modes of transportation the usefull stones as per the direction of the Engineer-in-Charge. Any loss to the public and private propriety during the course of execution and disposal of serviceable and unserviceable materials shall be the absolute responsibility of the contractor and shall have to be duly compensated by him in all respects including all incidental charges. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 4 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm Approved quality ncluding carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 6 | Providing and laying vitrified wall tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Approved quality ncluding carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 7 | 15 mm cement plaster in single coat on Rough side of brick/Concrete /stone walls for interior plastering up to all floor level including arises internal rounded angles chamfers and or rounded angles not exceeding 80 mm in grith and finished even and smooth in cement motar 1:6 (1 cement : 6 Sand) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 8 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 40 mm thick 2nd Class D/Wood including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 9 | Providing and fixing PVC pipes 100 mm dia (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 10 | P/F G.I / M.I union 100 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 11 | P/F PVC Tee 75 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 12 | Providing and fixing PVC pipes 75 mm dia (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 13 | P/F PVC Collar 75 mm nominal bore (Heavy duty)including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 14 | P/L G.I Pipe 15 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 15 | P/F G.I / M.I union 15 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 16 | P/F G.I Nipple 15 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 17 | Providing and fixing G.I Tee 15 mm dia (Heavy duty )including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 18 | Providing and fixing water closet squatting pan (European type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 19 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 20 | P/F CP Brass Bib Cock 15 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 21 | P/F CP Brass Stop Cock 15 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 22 | P/F C.P. Brass angle cock 15mm dia (heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 23 | P/F Gate Valve 15 mm nominal bore (Heavy duty) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 24 | Providing and fixing C.P stainless grating with hole (100 mm dia) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 25 | Providing and fixing plactic seat (Solid and hollow type) and cover for wash down water closet with CP brass hinges and rubber buffers white plastic seat and cover including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 26 | P/F PVC Connection pipe 15 mm dia 45 cm long with Brass Union for wash basin & Sink including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 27 | Renewing of glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 28 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 29 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 30 | Providing and fixing aluminium Handle, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 125 mm including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 31 | Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete. |
| 32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 33 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 34 | Providing and fixing PVC water storage tank syntax or equivalent three layer cost of connecting / tank nipples , making connection etc. 1000 litres capacity including all assecories including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. |
| 35 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including carriage of materials within all leads lifts and other incidentals as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |