| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | 15.57Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and falseceiling including disposal of unserviceable material and stacking of serviceablematerial with in 50 metres lead as directed by Engineer - in-Charge |
| 3 | 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 4 | 15.7.3Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In lime mortar |
| 5 | 15.2.1Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 6 | 15.60Disposal of building rubbish/ malba/ similar unserviceable, dismantled or wastematerials by mechanical means, including loading, transporting, unloading toapproved municipal dumping ground or as approved by Engineer-in-charge, beyond50 m initial lead, for all leads including all lifts involved |
| 7 | 15.52Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) includingstacking of useful materials near the site and disposal of unserviceable materialswithin 50 metres lead |
| 8 | 14.82Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/cmalba all complete as per directions of Engineer-in-Charge |
| 9 | 15.19Dismantling steel work manually / by mechanical means in built up sections withoutdismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. |
| 10 | 50.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 11 | 15.56Dismantling old plaster or skirting raking out joints and cleaning the surface forplaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 12 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 13 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost ofmaterials, labour charges etc complete |
| 14 | 50.4.1.1Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 12.5 mm nominal size) up to floor five level excluding thecost of centering, shuttering, finishing for leveling coarse of floor and roof etc. |
| 15 | 22.5Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry. |
| 16 | 11.41.3Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 800x 800 mm |
| 17 | 11.48.3Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 800x800mm |
| 18 | 11.49.3Providing and laying Vitrified tiles in floor with different sizes (thickness to bespecified by the manufacturer), with water absorption less than 0.08% andconforming to IS : 15622, of approved brand & manufacturer, in all colours andshade, laid with cement based high polymer modified quick set tile adhesive (waterbased) conforming to IS : 15477, in average 6 mm thickness, including grouting ofjoints (Payment for grouting of joints to be made separately).Size of Tile 800x800mm |
| 19 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 20 | 8.2.2.2Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm |
| 21 | 8.4Extra for fixing marble/ granite stone, over and above corresponding basic item, infacia and drops of width upto 150 mm with epoxy resin based adhesive, includingcleaning etc. complete. |
| 22 | 8.5Extra for providing opening or required size & shape for wash basin/kitchen sinkin kitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete. |
| 23 | 12.53Providing and Fixing 15 mm thick densified tegular edged eco friendly lightweight calcium silicate false ceiling tiles of approved texture of size 595 x 595mm in true horizontal level, suspended on inter locking metal grid of hot dippedgalvanised steel sections (galvanising @ 120 grams per sqm including bothside) consisting of main ‘T’ runner suitably spaced at joints to get requiredlength and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm(Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre tocentre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mmand size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked atmiddle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting onperiphery walls /partitions on a Perimeter wall angle pre-coated steel ofsize(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help ofrawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230mm interval and laying 15 mm thick densified edges calicum silicate ceilingtiles of approved texture in the grid, including, cutting/ making opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc.,wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mmlong dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clipsof size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’,bottom exposed with 24 mm of all Tsections shall be pre-painted with polysterbaked paint, for all heights, as per specifications, drawings and as directed byEngineer-in-Charge. |
| 24 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 25 | 21.1.2.2For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 26 | 21.16.2Providing and fixing aluminium round shape handle of outer dia 100 mm with SSscrews etc. complete as per direction of Engineer-in-Charge.Powder coated minimumthickness 50 micron aluminium |
| 27 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 28 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 29 | 21.13Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 30 | 9.84Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete. |
| 31 | 9.97.3Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm |
| 32 | 50.9.12.1Providing and fixing Thomson Multi wood board or equivalent make, in shelves withscrews and fittings wherever required, edges to be painted with polyurethane primer(fittings to be paid separately) as per the direction of site Engineer-in-charge. |
| 33 | 13.99.1Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 34 | 13.114Melamine polishing on wood work (one or more coat). |
| 35 | OD357025/2025-2026Providing and fixing SS hydraulic soft close auto hinges for shelf with necessaryfittings including cost and conveyance of all materials and labour charges etc.complete |
| 36 | 9.81.3Providing and fixing bright finished brass handles with screws etc. complete:75 mm |
| 37 | 9.79.1Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm |
| 38 | OD357042/2025-2026Providing and fixing 12 mm thick frameless toughened glass of approved brand andmanufacture, including providing and fixing over frame work etc. complete as per thedirection of Engineer-in-charge. |
| 39 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 40 | 13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 41 | 50.18.7.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall |
| 42 | 50.18.9.16.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall |
| 43 | 50.18.9.17.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 mspacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 63 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 44 | 50.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 45 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 |
| 46 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 47 | 18.7.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall20 mm nominal dia pipes |
| 48 | 18.9.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings. This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching , refilling & testing of joints complete as per directionof Engineer- in-Charge. External work50 mm nominal dia pipes |
| 49 | 17.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 50 | 17.3.1Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials of standard make and mosquito proof coupling of approvedmunicipal design complete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :W.C. pan with ISI marked whitesolid plastic seat and lid |
| 51 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 52 | 9.118.1Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles andrails mitred and joint at the corners by means of M.S. galvanised/plastic brackets ofsize 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The stylesof the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1mm (± 0.1 mm) wall thickness. The lock rail made up of 'H'section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm)wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S.'U' cleats. The shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm(± 0.1 mm) wall thickness. The panels filled vertically and tie bar at twoplaces by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturer's specification and direction ofEngineer-in-charge( For W.C. and bathroom door shutter). |
| 53 | 9.119Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wallthickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. squaretube of 19 gauge, EPDM rubber gasket weather seal to be provided through out theframe. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer's specification and direction of Engineer-inCharge. |
| 54 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge. |
| 55 | 17.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. |
| 56 | 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 57 | 18.21.2.1Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 58 | 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 59 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 60 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 61 | OD357050/2025-2026Providing and fixing ACP name board (24"x8" ) including cost andconveyance of all materials and labour charges etc complete. |
| 62 | OD357051/2025-2026 Providing and fixing roller blinds made of polyester fabric, featuring a heavy-duty 12-gear universal control head, metal brackets for secure installation, a 38 mm diameteraluminum roller tube, and an aluminum heavy bottom rail for stability. |
| 63 | OD357085/2025-2026Additional labour and materials for Red oxide flooring repair work in ramp. etccomplete. |
| 64 | OD357099/2025-2026Supply of WPC door of size 140x 210 mm with seal strip, hinges etc. |
| 65 | OD357100/2025-2026Providing and fixing WPC wall Groove, Rectangular shape, thickness 23mm. |
| 66 | 10.5.1Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces |
| 67 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 68 | Electrification Works |
| 69 | 2.2.1Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.100 A, 16KA |
| 70 | 90.12.7.27Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 25 sq mm with factory madeclamp |
| 71 | OD358087/2025-2026Supplying and fixing of following ways surface/ recess mounting, vertical type, 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powderpainted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door |
| 72 | OD358115/2025-2026Supplying and fixing 100 amps rating, 240/415 volts, \\"\\"C\\"\\" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.Triple pole |
| 73 | 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 74 | 9.1.20Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X25 sq.mm (28mm) |
| 75 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 76 | 9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) |
| 77 | OD358118/2025-2026Supplying and fixing following way, horizontal type three pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface / recess, complete with tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 78 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 79 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 80 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 81 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 82 | 1.3.3Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with modular switch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc asrequired.Group C |
| 83 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 84 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 85 | 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 86 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 87 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 88 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet |
| 89 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 90 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 91 | 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.8 Module(125mmX125mm) |
| 92 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. |
| 93 | 1.38Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete asrequired. |
| 94 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable |
| 95 | 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C |
| 96 | OD358122/2025-2026Cable management System for secure and safe routing of power cables and wires |
| 97 | OD358123/2025-2026Supply, Conveyance, installation, testing and commissioning of 400 mm sweep WallMounting fan using mounting brackets supplied along with the fan. |
| 98 | OD358124/2025-2026Supply and installation of 1200mm, 20W LED tubelight with all accessories asrequired. (Make: Crompton/Philips/Wipro) |
| 99 | 4.1.4Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 100 | 90.16.1.4Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 101 | 5.15Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connectionsetc. as required. |
| 102 | 5.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required |
| 103 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 104 | OD358137/2025-2026Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and givingconnections with 16/0.20 mm 3 core PVC insulated and sheathed round copperconductor flex wire or extending the original wiring and giving connections asrequired.12/15W LED Downlight(Round) |
| 105 | OD358138/2025-2026Supply and Installation of 15W Working Table lamp with white light with aminimum lumen level of 400 Lumen for comfortable shade free stress free vision |
| 106 | OD358670/2025-2026Supply, conveyance, installation, testing and commissioning of 2 ton 5 Star ratedInverter Split Air conditioner unit. Suitable for working on 240V single phase ACsupply, including providing copper piping from indoor to outdoor units, suppliedalong with the unit , providing necessary electrical connection form indoor to outdoorunits etc. as required. (Make: Bluestar, LG, Carrier or equivalent approved make) |
| 107 | OD358681/2025-2026Supply and Installation of extra copper pipe line for the installation of air conditionerunits extended with required insulation and protection as required with completeaccessories as required |
| 108 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator |
| 109 | 1.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 110 | OD358694/2025-2026Refurbishment of 1.5 TR Air Conditioning Unit with dismantling, Detailed Servicing, Coolant Refilling and Installation, Testing and Commissioning. |
| 111 | Biomedical |
| 112 | OD358884/2025-2026Supply, Installation, Testing and Commissioning of Programmable Dental Chair. Unitfitted with. With MM LED (EDI,FARO italy)Operating light having On/Off &intensity control by non- touch sensor Blue Round glass spitoon detachable andautoclavableHigh and low vacum motorised CRS Suction SystemBeecool II light cure.Modular Trolley System With Hanging Cord.Two airotor points.Supreme micromotor with speed disply 3 way syringe - 2 No.Supreme optic scaler five scaling Tip x ray viewer, SS instrument tray multi functionfoot control |
| 113 | OD358885/2025-2026Supplying of EURO Dental operator's Stool |
| 114 | OD358886/2025-2026Supply, Installation, Testing and Commissioning of Confident 1HP compressor withdrier and filterClean air-150 monobloc oilfree, Medical grade airotor air compressor 1HP minimumnoise,with drier and filter fitted on MS tank |
| 115 | OD358887/2025-2026Supply, installation, testing and commissioning of Confident Sterline B-classAutoclave 23 liter with thermal printer,including water distler plant. |
| 116 | OD358888/2025-2026Supply of Handpiece:-NSK Airototor SUB2 Airotor Handpiece |
| 117 | OD358889/2025-2026Supply, conveyance and installation of SS HAND WASH SINK WITH ELBOWOPERATED TAPMake:captMaterial: SS3043 Side covering |
| 118 | EXCLUSIVE OF GST |
| 119 | Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL |
| 120 | 2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items |
| 121 | 3.Rate should be Exclusive of GST. |
| 122 | 4.Work should be executed as per DSR/PWD specification and direction of Engineer at site. |
| 123 | 5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 124 | 10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS. |
| 125 | 11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately. |
| 126 | Make of Electrical equipments/materials |
| 127 | All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification |
| 128 | Panel Boards: CPRI certified reputed manufacturers make |
| 129 | MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent |
| 130 | Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD |
| 131 | Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent |
| 132 | Cable Glands & Sockets - REPUTED MAKE , Cosmos |
| 133 | Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent |
| 134 | Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj |
| 135 | 12. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference. |
| 136 | 14.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client |
| 137 | 15.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client |
| 138 | 16.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO |
| 139 | 18. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail