| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and lift upto 1.5 m. |
| 4 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)2in Foundation |
| 8 | Reinforced cement concrete work in beams;suspended floors;roofs having slope upto15 landing s;balconies;shelves;chajjas;lintel s;bands;plain window sills staircases and spiral staircases up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)In Lintel & Projection |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 7.5 in foundation and plinth in: cement mortar 1:6 (1 cement : 6 coarse sand) :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Centring and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and accessplatform |
| 11 | Lintels,plinth beam& Beams |
| 12 | Foundation, Footing base of column etc. |
| 13 | In Column's |
| 14 | Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) |
| 15 | Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apieceof cloth lightly soaked in kerosene oil. |
| 16 | Brick work with Class-150 class bricks instead of Class-75 informing to IS: 2222 -1991 in superstructure above plinth level upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 17 | Half brick masonry with F.P.S. bricks of class designation 150 in superstructure above plinth level upto floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 18 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommendedproportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommendedproportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 20 | Extra for cutting rebate in flush door shutters (Total area of the shutterto be measured). |
| 21 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer |
| 22 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as requiredn gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works |
| 23 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolledsteel sections, joints mitred and flash butt welded and sash bars tenonedand riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 24 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 25 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra paymenton this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 26 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 27 | 12 mm cement plaster on the fair side of single or half brick wall of mix :1:6 (1 cement : 6 coarse sand) |
| 28 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 30 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigmentsetc. complete.Size of Tile 600x600 mm |
| 31 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm |
| 32 | Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 33 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete. |
| 34 | Providing and laying rectified Glazed Ceramic Wall tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, exceptWhite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 35 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thicknessto be specified by the manufacturer), of 1st quality conforming to IS : 15622,of approved make, in all colours, shades, except White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4(1 Cement : 4 Coarse sand), including pointing the joints with whitecement and matching pigments etc., complete. |
| 36 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 37 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeNew work (Two or more coats applied @ 1.43 ltr/ 10 sum. over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sum). |
| 38 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two or more coats) over and including waterthinnable priming coat with cement primer |
| 39 | Providing and applying white cement based putty of average thickness 1mm,ofapprovedbrandandmanufacturer,overtheplasteredwall surfacetopreparethesurfaceevenandsmoothcomplete |
| 40 | Construction of drain of size of size 150 x 150 mm along with apron including excavation,base concrete 1:4:8 in thickness of 7.5cm of and brick work in foundation 1:4( 1 cement : 4 coarse sand) and brickwork in half brick thick in foundation 25mm thick cement concrete (1:2:4 mix) flooring base and 20mm thick plaster (1:2) finished with neat cement. (Analysis) |
| 41 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. |
| 42 | Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screwsetc. complete :300x16 mm |
| 43 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :250x10 mm |
| 44 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :200x10 mm |
| 45 | Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : |
| 46 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 47 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :Providing filling cinder in sunken portion |
| 48 | Wiring for light point/fan point/ exhaust fan/call bell point with 1.5 sqmm. FR PVC insulated copper conductor single core cable in Surface/ recessed medium class PVC conduit, , with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable etc as required. |
| 49 | Wiring for twin control light point with 1.5 sqmm. FR PVC insulated copper cunductor single core cable in Surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable size G.I.box and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable etc. as required. |
| 50 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connection, painting etc. as required. |
| 51 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps. modular socket outlet and 15/16 amps. modular switch, connection, painting etc. as required. |
| 52 | Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metal enclosed plug top along wth 25/32 amp. `C` series SP,MCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 53 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 54 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 55 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 56 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 57 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 58 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X10.0 sqmm + 1x 6.0 sqmm earth wire |
| 59 | Supplying and fixing following way, prewired SP&N MCB distribution board of sheet steel for 240 volts on surface /recess complete with loose wire box, terminal connection for all incoming and outgoing circuit,duly prewired with suitable size FR PVC insulated copper conductor up to terminal block, tinned copper busbar, neutral link, earth bar, din bar,detachable gland plate, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 6 way , Double door |
| 60 | Supplying and fixing following way, prewired three pole and neutral MCB distribution board of sheet steel for 415 volts on surface /recess complete with loose wire box, terminal connection for all incoming and outgoing circuit,duly prewired with suitable size FR PVC insulated copper conductor up to terminal block, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 6 way (4 + 18), Double door |
| 61 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.6/32 ampsSingle Pole |
| 62 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 63 | Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 miliampere in the existing MCB DB complete with connections,testing and commissioning etc. as required :63 Amps |
| 64 | Earthing with GI earth pipe, 4.5mtr long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement etc, (with charcoal and salt ) as required. |
| 65 | Supplying and Laying of 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 66 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 67 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 68 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 69 | Installation of exhaust fan p in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm swee |
| 70 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 71 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including the trench etc as required. Upto 35 sq.mm |
| 72 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Upto 35 sq.mm |
| 73 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 74 | Supply and laying of aluminium conductor PVC. insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make- Havels / Pasaka16 sqmm 4 core |
| 75 | Supply and laying of aluminium conductor PVC. insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make- Havels / Pasaka120 sqmm 3.5 core |
| 76 | Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX300mm sweep. |
| 77 | SUPPLY OF 6 to 10 Watt , LED Down Lighter Make- Havells INTEGRANXTRDDLRSURD9WLED865S |
| 78 | SUPPLY OF 40W TUBE LIGHT STOUTPLUS1200BS40WLED857SPCWHa) 1x40 Watt. |
| 79 | S/F OF 10W Mirror Light Make: ENDURALINEARNEOBS10WLED865SPCWH |
| 80 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.300 mm dia |
| 81 | Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer -in-charge, beyond 90 metre & upto 150 metre depthbelow ground level.300 mm dia |
| 82 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia |
| 83 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 84 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.(0.785*0.4*0.4*90)-(0.785*0.2*0.2*90)=8.478 CUM |
| 85 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 86 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of : 100 mm dia |
| 87 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp. |
| 88 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia. |
| 89 | Supply of submersible pump of make KSB 2.0 HP with control panel, support wire etc. complete. |
| 90 | Providing 2 core PVC insulated submersibble cable from pump panel to submersible pump |
| 91 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore |
| 92 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 32 mm nominal bore. |
| 93 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 94 | Providing and fixing white viterous china pedestal type water closet (europen type) with seat and lid, 10 litre low level flusing cistem with fittings &C.I/M.S Brakets ,40mm fluse bend , overflow arrangment with special of standard make and mosqiito proof coupling of approved muncipal design complete including painting of fitting and brackets , cutting and making good the walls and floors where ever required .Confirming to IS : 7231, Parryware, /Hindware/ Seabird/Orient(Coral) W.C. pan with ISI marked white solid plastic seat |
| 95 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 96 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :one urinal basins with white P.V.C. automatic flushing cistern |
| 97 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink asper IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making goodthe walls wherever required :Kitchen sink with drain board |
| 98 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.510x1040 mm bowl depth 250 mm (Semi rigid pipe) 32 mm dia (for wash basin) |
| 99 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.510x1040 mm bowl depth 250 mm (Semi rigid pipe) 40 mm dia (for sink and urinal) |
| 100 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 101 | Providing and fixing unplasticised PVC connection pipe with brass unions (45 cm length)15 mm nominal bore |
| 102 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 103 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.a) 15 mm nominal bore |
| 104 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 105 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet150 mm diameter |
| 106 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15mm nominal bore |
| 107 | Providingandfixing8mmdia C.P. /S.S.Jetwithflexibletube upto 1 metre long with S.S. triangular plate to Eureopeantype W.C. of quality and make as approved by Engineer - in - charge |
| 108 | Providing and fixing CP Brass 32mm size Bottle Trap ofapproved quality & make and as per the direction of Engineer-in-charge. |
| 109 | Providing and fixing toilet paper holder |
| 110 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass bracketsandguardrailcompletefixedwith40mmlongscrews,rawl plugs etc.,complete |
| 111 | Providing and fixing white vitreous china extended wallmountingwater closet of size 780x370x690 mm of approved shape includingproviding & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etccomplete. |
| 112 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes |
| 113 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes |
| 114 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).15mm dia nominal bore |
| 115 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).20mm dia nominal bore |
| 116 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).25mm dia nominal bore |
| 117 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).32mm dia nominal bore |
| 118 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).40mm dia nominal bore |
| 119 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).15mm dia nominal bore |
| 120 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).20mm dia nominal bore |
| 121 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 25mm dia nominal bore |
| 122 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 32mm dia nominal bore |
| 123 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).40mm dia nominal bore |
| 124 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore |
| 125 | Providing and fixing gun metal gate valve with wheel of approved quality.32mm dia nominal bore |
| 126 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore |
| 127 | Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore |
| 128 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm |
| 129 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. b) 75mm dia P.V.C. pipe |
| 130 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door10x110x110 mm |
| 131 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door10x110x110 mm |
| 132 | Bend 87.5°110 mm diameter |
| 133 | Providing and fixing unplasticised -PVC pipe clips of approved designto unplasticised - PVC rain water pipes by means of 50x50x50 mmhard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm |
| 134 | Providing and fixing of upvc SWR pipe type-B confirming to is -13592 including jointing the pipes with rubber ring ,lbricant, and upvc SWR cupler confirming to IS- 14735. also including excavation of trucnchescutting of walls ,floors and refilling the trunchesas before but excluding supply and cost of other fitting such as elbow, bend, tee and y tee including supply of all material labour and T& P Required for proper complition of work110 mm dia |
| 135 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree110 mm Bend |
| 136 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain)110 mm Shoe |
| 137 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 138 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 139 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes forinlet,outlet and overflow pipes but with outfittings and the base support for tank |
| 140 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.All kinds of soilPipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 141 | Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm diameter |
| 142 | Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter |
| 143 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design100mm dia SW pipe |
| 144 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design150mm dia SW pipe |
| 145 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design150 x 100 mm size P typeWit Sewer bricks conforming to IS : 4885 |
| 146 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 150(i) For Sewer Line |
| 147 | Extra for depth for manholes: Size 90x80cm with FPS bricks(class I)RM75.90/100=0.67 |
| 148 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 149 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 150 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 7.5 in foundation and plinth in: cement mortar 1:6 (1 cement : 6 coarse sand) :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 151 | Reinforced cement concrete work in beams;suspended floors;roofs having slope upto15 landing s;balconies;shelves;chajjas;lintel s;bands;plain window sills staircases and spiral staircases up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)In Lintel & Projection |
| 152 | Centring and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and accessplatform |
| 153 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 154 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floatingcoat of neat cement 20 mm cement plaster |
| 155 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 156 | Providing and fixing in position pre-cast R.C.C. manhole cover andframe of required shape and approved quality |
| 157 | Circular shape 560 mm internal dia EHD - 35Making soak pit 2.5 m diameter 3.0 m deep ith 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter 1.8 m long complete as per standerd design |
| 158 | Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work |
| 159 | Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. |
| 160 | Supply and fixing of fire bucket 9-11 litres capacity with river sand fill supply of all materials and labour for proper completion of work. |
| 161 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 162 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and lift upto 1.5 m. |
| 163 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 164 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 165 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 166 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) in Foundation |
| 167 | Reinforced cement concrete work in beams;suspended floors;roofs having slope upto15 landing s;balconies;shelves;chajjas;lintel s;bands;plain window sills staircases and spiral staircases up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)In Lintel & Projection |
| 168 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 7.5 in foundation and plinth in: cement mortar 1:6 (1 cement : 6 coarse sand) :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 169 | Centring and shuttering including strutting, propping etc. and removal of form for :Lintels,plinth beam& Beams |
| 170 | Centring and shuttering including strutting, propping etc. and removal of form for :Foundation, Footing base of column etc. |
| 171 | Centring and shuttering including strutting, propping etc. and removal of form for :In Column's |
| 172 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 173 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 174 | 12 mm cement plaster on the fair side of single or half brick wall of mix :1:6 (1 cement : 6 coarse sand) |
| 175 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two or more coats) over and including waterthinnable priming coat with cement primer |
| 176 | Providing and applying white cement based putty of average thickness 1mm,ofapprovedbrandandmanufacturer,overtheplasteredwall surfacetopreparethesurfaceevenandsmoothcomplete |
| 177 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(As Per DSR No 2.8) |
| 178 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.(As Per DSR 4.1.8) |
| 179 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.(AS Per DSR No 6.1.2) |
| 180 | 40mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.(As Per DSR No 4.10) |
| 181 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge (As Per DSR 16.91.2) |
| 182 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy