| 1 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 2 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.Third Floor |
| 3 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 4 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 5 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. In Third Floor |
| 6 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade. (i) Pakur Variety. In Third Floor |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m. I. SAIL/ TATA/RINLIn Third Floor |
| 8 | Brick work with 1st class bricks in cement mortar (1:4)(b) In Superstructure, In Third Floor |
| 9 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in third floor. |
| 10 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi/ Udaypur pink / Udaypur Green / Black Bhaslana(iv) Area of each slab/tile exceeding 1.00 sq.m (This item to be executed on specific permission of Superintending Engineer). In Third Floor |
| 11 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour, In Third Floor |
| 12 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety, In third floor |
| 13 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) Pakur Variety, In third floor |
| 14 | (viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. In Third Floor |
| 15 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.r. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] In Third Floor |
| 16 | (iv) Two point nose steel handle including fitting and fixing. |
| 17 | (vi) steel peg stay 300 mm long including fitting and fixing. |
| 18 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above. In Third Floor |
| 19 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(c) Sal : Siliguri. In ground floor |
| 20 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(c) 40mm X 6mm, 125mm Length |
| 21 | (i) Door stopper.(Brass) |
| 22 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(v) 150mm long x 12mm dia. bolt. |
| 23 | ii) Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. |
| 24 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (vi) 125 x 63 x 3.2mm |
| 25 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(iv) 125 mm grip x 10 mm dia rod. |
| 26 | Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittingsIn ground floor(a) 35mm thick shutters (single leaf) |
| 27 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For roof truss worksa) Span up to 20 Mtr In Third Floor |
| 28 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:-a) With 0.5 mm thick sheet. In third Floor |
| 29 | Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (b) 300 mm. wide gutter. In Third Floor |
| 30 | Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each way(b) With 0.91 mm sheet. In Third Floor |
| 31 | Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/m3, 50m mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh for top most ceiling of building. In third Floor |
| 32 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.In Third floor.a) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U 1520). |
| 33 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete)In Third floor. |
| 34 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (b) 15 mm thick plasterExternal Wall. In Third Floor |
| 35 | (ii) With 1:4 cement mortar(c) 10 mm thick plaster. (Internal & External) In Third Floor |
| 36 | (ii) With 1:4 cement mortar(a) 20 mm thick plasterInternal Wall. In Third Floor |
| 37 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 38 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. i) In Third Floor |
| 39 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 40 | Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturer's specification)including cleaning and smoothning of surface.Two Coats. In Third Floor |
| 41 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Third Floor)(b) Two Coatsi) Water based interior grade Acrylic Primer |
| 42 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor (b) Two Coats |
| 43 | ii) In First Floor |
| 44 | iii) In Third Floor |
| 45 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground Floor (b) Premium 100% Acrylic Emulsion |
| 46 | ii) In First Floor |
| 47 | iii) In Third Floor |
| 48 | (b) Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc. |
| 49 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 50 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc.including using of approved putty etc. on the surface,if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (ii) Two coats (white in shade) |
| 51 | (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) |
| 52 | Supplying best Indian figured glass viz. hammered, fluted, ribbed,pinhead etc. type including cutting to required sizes, setting on putty bases and fitted and fixed with nails and putty complete.(In all floors for internal wall & upto 6 m height for external wall) (i) 3 mm thick (White) |
| 53 | C. ADDITIONAL RATE Extra for fixing glass panes in steel window. |
| 54 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. |
| 55 | c) Bend 87.5 degree(ii) 110 mm. Dia. |
| 56 | d) Shoe (ii) 110 mm. Dia. |
| 57 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work) a) 2- track sliding windowi) Bottom frame |
| 58 | ii) Top and side frame. |
| 59 | b) 3- track sliding windowi) Bottom frame |
| 60 | b) 3- track sliding window ii) Top and side frame. |
| 61 | d) Shutter for all track sliding window.i) Bottom & Top member. |
| 62 | ii) Style side member. |
| 63 | iii) Interlock member |
| 64 | Labour charge for fabrication and installation of composite door, window , partitions made from annodized extruded alloy aluminium sections for the following units:-(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers.i ) 2 track sliding window. |
| 65 | ii ) 3 /4 track sliding window. |
| 66 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987;(i) 5mm thick |
| 67 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work 32 mm |
| 68 | (b) For Concealed Work 25mm |
| 69 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (iii) 630 mm X 450 mm size |
| 70 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |
| 71 | (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 72 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(ii) 450 mm long |
| 73 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (ii) 750 mm long |
| 74 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.(ii) 600 mm X 450 mm |
| 75 | Supplying, fitting and fixing liquid soap container.(b) PTMT(Prayag or equivalent) |
| 76 | Supplying, fitting and fixing towel rail with two brackets. (ii) 25 mm dia. and 600 mm long |
| 77 | Supplying and fixing double door 4WAY Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43protection, with 1 No. 160 A FP MCCB as incomer and 4 NOS 63A TP MCB as outgoing complete on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/LK) |
| 78 | Supplying and fixing double door 6 way TPN MCB Distribution board with IP-42/43 protectionwith 1 No. 63 A FP MCB as incomer and 18 nos. 6-32 A SP MCB as outgoing complete , concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with following MCBs. (Make-Legrand/LK) |
| 79 | (a) S & F 2+10 way double door IP-43 SPN MCB distribution board with 1 No. 40 A DP MCB as incomer and 10 no 6-32 A SP MCB as outgoing complete with Din Rail, Earth, Neutral & Phase Bars etc. to be partially recessed in wall with earthing attachment. (Make-Legrand/LK) |
| 80 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make-KEI/Polycab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish a) Avg run 8 mtr. |
| 81 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Make-Legrand/LK)incl. S&F earth continuity wire, fixed on 4 Module GI switchboard with 3/4 Module top cover plate flushed in wall incl.mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board. |
| 82 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket ((Make-Legrand/LK)) with 6A Modular type switch, without plug top on 4 Module GI/PVC Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 83 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make-Legrand/LK) with 16A Modular type switch, without plug top on 4 Module GI /PVC Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 84 | Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991) |
| 85 | Supply & Fixing 240V, Modular Socket (2 Module) type fanregulator (Step type) (Brand approved by EIC) on existingModular GI switch board with top cover plate incl. makingnecy. connections etc. |
| 86 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 87 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. |
| 88 | Fixing only bulk head /ceiling fitting on wall /ceiling by screws etc. |
| 89 | S & F 250 V 1200 mm sweep AC ceiling fan (ISI) complete with blades, canopy, down rod etc. having fixed with 2 nos ball bearing fixing the same, painting of down rod, connection by supplying 3×1.5 sq. mm stranded copper wire. (Make-Usha/Crompton) |
| 90 | Supply of surface mounted 18 watt slim LED panel with aesthetic finish powder coated in white housing luminaire (square/round) to be fixed on ceiling at in corridor, stair etc. with all arrangement and necessary connection. (Make-Philips/Crompton) |
| 91 | Supplying and fixing 19 mm dia and 3 mm thick polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) |
| 92 | Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe by the GI fish wire and making necy. connection as required. as per instruction of EIC.a) 4×10 sq.mm. + 2×6 sq.mm. (Make-KEI/Polycab) |
| 93 | b) 2×10 sq.mm. + 1×6 sq.mm. (Make-KEI/Polycab) |
| 94 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) (Make-KEI/Polycab) |
| 95 | 3 x 22/0.3 (3x1.5 sqmm) (Make-KEI/Polycab) |
| 96 | i) Earthing with 50 mm dia GI pipe (ISI-M) 3.64 mm thick × 3.04 mtr long and 1 × 4 SWG (Hot dip) wire 4 mtr long) 13 mm dia × 80 mm long GI bolts double washers incl. S & F 15 mm dia GI pipe protection (1 mtr long) to be filled with bitumen party under the ground level and partly above ground level driver to an average depth of 3.65 metre below the ground level & restoring the surface duly rammed. |
| 97 | S & F earth bus bar of GI (Hot Dip) MS flat of 50 mm × 6 mm on wall is having clearance of 8 mm from wall including providing drilled holes on the bus bar complete with GI bolts, nuts, washers spacing insulators tc. As required. |
| 98 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe including Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 99 | Supply 1.1 KV grade PVC Armoured XLPE insulated AL conductor cable . (Make-KEI/Polycab) 3.5 core X 70 sq.mm. |
| 100 | Laying of cable ( 3.5 core X 70 sq.mm.) on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 101 | S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture -proof entry of XLPE/PVC armoured cables as bellow. 3.5 core X 70 sq.mm. |
| 102 | Finishing the end of following XLPE/PVC armoured cable by crimping method incl.S & F solderless socket (Dowels make,) tapes,anticorrosive paste & joining materials. 3.5 core X 70 sq.mm. |
| 103 | Supply 1.1 KV grade PVC Armoured XLPE insulated AL conductor cable . (Make-KEI/Polycab) 4 core X 16 sq.mm. |
| 104 | Laying of cable ( 4 core X 16 sq.mm..) on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 105 | S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture -proof entry of XLPE/PVC armoured cables as bellow. 4 core X 16 sq.mm. |
| 106 | Finishing the end of following XLPE/PVC armoured cable by crimping method incl.S & F solderless socket (Dowels make,) tapes,anticorrosive paste & joining materials.4 core X 16 sq.mm.. |
| 107 | Installation of security lighting:After dismantling existing mini pole with accessories and fixing outdoor type fluorescent/SV/MV light fitting on poleincluding S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting |
| 108 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 109 | Supply & laying of 3 X 2.50 sq. mm PVC insulated copper conductor FR wire from loop box to fittings in 15 mm dia polythene pipe including connection as required. (Make-KEI/Polycab) |
| 110 | Supply of 120 W LED Street light luminaire with high power LED .(Make-Philips/Crompton) |
| 111 | lift: - Supply & installation of 10 passengers lift complete with all allied accessories like motor, MS. Supports, lift carriage auto control panel etc.(Make-Kone /OTIS Elevator Ltd. as follows.i)No. & type of lift - passenger lift. Capacity - 10 passenger( 680 Kg). Speed - 1mps. NO. of stop & opening -4 stop & 4 opening(all opening are in the same side),G+3. Travel Height - G+3. Power Supply -415V A.C 3 phase 50 HZ +/ - 10% ii)Motor - BBL / Marathon / Havell's / ABB make. Gear Box - Greaves (premium). iii)Rear Shaft Dimension - 2000 mm X 2000 mm. (approx) Pit Depth - 1400 mm. (approx) Over Travel - 4800 mm. (approx) Indicator -16 segment digital BRAIL push button with up & down arrow indicator. Car Enclosure- 1.2 mm thick SS sheet make with hairline finish. Car dimension - 1300mm wideX 1350mm deepX 2200 mm height . Car Door - Stainless steel hair line finish Telescopic Auto Door. Landing Doors - Stainless steel AISI441 hairline. Landing Entrance - 800mm X 2000mm. clear Door Opening - 800mm X 2000mm. Overload Protection - Audio Indication in Car & Lift with not start when overload actuated and door kept open at that time. iv)Emergency Light & Alarm - Battery operated alarm bell and emergency light of rechargeable type. Main Rope - 13mm dia X 4 nos. (1:1 roping), Usha Martin make. Governor Rope - 8mm dia Usha Martin make. Car Fan - 1no. Cabin Fan. ON/OFF switch at COP. Car light - 4 nos. CFL Please Enable Macros to View BoQ information |