| 1 | Dismantling and removing mangalore roofing tiles from roofs including ridges, hips, valleys, sheets wind ties etc. but excluding battens, roof timber etc. and stacking materials within a distance of 50 mt. |
| 2 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas ( exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m. on plan) including disposal of excavated earth, lead upto 50 m. and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : |
| 3 | All kinds of soil |
| 4 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting outthe excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. |
| 5 | All kinds of soil |
| 6 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 7 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 8 | All works upto plinth level |
| 9 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 10 | Wood Finish Foam Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness asper options below by using tray system, with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) along with printed matt havingwoodentextures,usedalongwith UVResistantresinto givethe clear wooden texture on the door. The core of shutter will be filled as specified(ExpandedPolystyreneFoam/Polyurethane Foam(EPS/PU) Foam) The shutter to be water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) Technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory. |
| 11 | Accessories: 1. S. S. Hinges 4” - 3 No 2. S. S. Latch - 1 No 3.0 Tower Bolt 5” - 2 Nos 4. Handle 5” - 2 Nos Shutter Thickness: c) 40mm |
| 12 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws. |
| 13 | Plain grill |
| 14 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section. |
| 15 | Figured glass |
| 16 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows. |
| 17 | Figured glass |
| 18 | Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size. |
| 19 | 40 x 3 mm flat iron hold fast, 15 cm long |
| 20 | Providing and fixing 150 mm. bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete. |
| 21 | Precast plain cement chequered tiles 22 mm thick of required shades laid in floors, treads of steps and landing on 20 mm thick bed of Cementmortar 1:4 (1cement:4 coarsesand)jointedwith neatcement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete. |
| 22 | Dark shades using ordinary cement |
| 23 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 24 | Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete |
| 25 | Dark Shades |
| 26 | Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-incharge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | Wall Ceramic Glazed Tiles : 200 x 300 |
| 28 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 29 | Providing and fixing Colouron Plus galvulium roofing Sheets of 0.5mm thick double ribbed trapezoidal profile coated 1080mm with cover width of 1020mm including all the accessories (JSW or equivalent make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 30 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 31 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 32 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 33 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 34 | Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 35 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 36 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. |
| 37 | Proving and fixing white vitreous china water closet squatting pan (Indian type w.c.pan)size580 mmwith 100mm sandcast ironP. orS trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mmdiameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required. |
| 38 | Orissa pattern W.C. pan |
| 39 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. |
| 40 | Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps. |
| 41 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design : |
| 42 | 150 x 100 mm size –P or S type |
| 43 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. |
| 44 | I. SCH-80(blue)/(white) : 25mm outer dia. |
| 45 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work Exposed on wall. |
| 46 | SCH-80(blue)/(white) : 20mm outer dia. |
| 47 | Providing and fixing brass bib cock (heavy) of approved quality : |
| 48 | 20 mm nominal bore |
| 49 | Providing and fixing brass stop cock (heavy) of approved quality : |
| 50 | 20 mm nominal bore |
| 51 | Providing and fixing ball valve (brass) of approved quality : |
| 52 | High pressure with P.V.C. floats : 20 mm nominal bore |
| 53 | Providing and fixing non-return valve of approved quality : |
| 54 | 32 mm nominal bore |
| 55 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : |
| 56 | 110 mm dia |
| 57 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. |
| 58 | 110 mm dia |
| 59 | Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door: |
| 60 | 110 mm dia. |
| 61 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: |
| 62 | 110 mm dia |
| 63 | Providing and placing on terrace roof offloor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996. |
| 64 | 500 lit. capacity |
| 65 | Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years fromthe date of completion including eradicating any infestation of termite freeof costduringtheguaranty periodcomplete. (Thepaymentwillbe made on plinth of the building. |
| 66 | Post construction |
| 67 | Providing and fixing Prince or equivalent make PVC SWR half round eaves gutter with bolts, nuts and flat iron brackets 40 x 3 mm size complete. |
| 68 | 250 mm nominal size |
| 69 | PVC false ceiling grid type : Providing and fixing PVC False Ceiling consisting of 600mm x 600mm, 5mm(±0.25) thick Plain PVC sheet of 600 kg/Cbm Density Manufactured by anISO-9000 certified Company, used aspanel insertina frame workmade usinganodized aluminumTsection of sizes 1” x1” (25x25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2’x2’(600x600mm). The aluminum frame work is supported from the ceiling with the help of 'J' hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level etc. The aluminum framework is supported on side wall with the use of aluminum L-section of size 1”x1” (25x25mm) angles etc. Complete as per direction of Engineer-In-charge, manufacturer’s specification & drawing. |
| 70 | Cuddappah stone slab machine cut flooring over 20mm (average) thickness of cement mortar 1:4 (1 cement : 4 coarse sand laid over andjointed with grey cementslurry mixed with pigmentto match the shade of the slab including rubbing and polishing complete - 25 mm thick. |
| 71 | Providing and fixing Granite stone slabs (mirror polished) 18mmthick in risers of steps, skirting, dado and pillars laid on cement paste and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 72 | Elite Brown |
| 73 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 including cutting of stone and making good the walls wherever required. Kitchen sink without drain board. with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete. |
| 74 | Overall size 535mmx460mm (21\\"x18\\") bowl size 460mmx380mmx200mm (18\\"x 15\\"x 8\\") depth 200 mm. Glossy. 1.0mm thk |
| 75 | Providing and fixing prefabricated compound gate of G.I. pipes 40 –50 mm dia (medium) with 12mm M.S. square bars of G.I. pipes grill work as per drawing including providing & fixing locking arrangements, pintals, hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggreate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction complete. |
| 76 | Providing & fixing 20 mm caves barge boards 2nd class matti wood |
| 77 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers. |
| 78 | Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws |
| 79 | 600 x 20 mm size |
| 80 | Providing & fixing liquid soap container with C. P. brass lid and brackets fixed to wooden cleats with C. P. brass screws |
| 81 | Plastic container |
| 82 | Lettering with black japan paint of approved brand and manufacture. *1 letter of 1 cm. ht. |
| 83 | Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x2.5”x10gauge) fixedwith angleironpostsandstrutsby G.I.or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) including providing barbed wire stiffeners (shall weigh 9.33 kg. per 100 meters minimum) at top and bottom with barbed wire stiffers by binding wires at 50cms centre to centre complete as per the direction of the Engineer – in – charge (angle iron posts struts, earthwork and concrete for fencing posts and struts to be paid separately) |
| 84 | Painting one or more coats with superior quality ready mixed paintof wood work of approved brand & manufacture in all shades on old work to give an even shade |
| 85 | Utility connections ( water & electricity ) as directed by Engineer in charge Please Enable Macros to View BoQ information |