| 1 | DSR Item No.1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | DSR Item No.1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/Recessed steel/PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 9 | 20 mm |
| 10 | 25 mm |
| 11 | DSR Item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 amps switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | DSR Item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | DSR item no. 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 16 | DSR Item No.1.27Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 17 | 1 or 2 Module (75mmX75mm) |
| 18 | 6 Module (200mmX75mm) |
| 19 | 8 Module (125mmX125mm) |
| 20 | DSR Item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 21 | DSR Item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 22 | DSR item no. 1.33Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 23 | DSR Item no. 2.2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 24 | 63/100 A,30KA, FP MCCB |
| 25 | 200 A,36KA, FP MCCB |
| 26 | DSR Item no. 2.3Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 27 | 6 way, Double door |
| 28 | DSR Item no. 2.4Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 29 | 4 way (4 + 12), Double door |
| 30 | DSR Item no. 2.10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | Single pole |
| 32 | Double Pole |
| 33 | Triple pole and neutral |
| 34 | DSR item no. 15.15Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. |
| 35 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 36 | DSR item no. 15.16Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 37 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 38 | DSR item no. 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 39 | DSR item no. 5.7Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 40 | DSR item no. 8.10LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LEDsurfacemounted Batten light of following body material and constructionas per IS : 10322 with driver (Replaceable) as per therequirement with Driver efficiency >85%, Operating voltageAC 140-270 Volt, freq 50/60 hz, Operating temp range -5 degto 40 deg centigrade, internal surge protection of 2.5 KV withShort & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI >80 , Flicker free (flicker should be below 5 %), life time(LED,Driver & electrical circuitary), of minimum 50000Burning Hours with , 70% of initial Lumen maintained tilllife ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standardand trade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testingfacilities for LED fixtures. complete in all respect i/c externalconnections with 1.5 sq mm FRLS/HFFR, PVC insulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty. System lumen efficacy≥120 <135 lm/Watt output . LM79 & LM80 Test report and alltesting required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm) |
| 41 | 18- 22 watt |
| 42 | DSR item no. 8.15LED Flood Light, powder coated pressure die castaluminium (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of FloodLight, powder coated pressure die cast aluminium body withbuilt in or separate driver as per the requirement with Driverefficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -5 deg to 50 degcentigrade, internal surge protection of 5 KV L,N,E as perIEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltageand over voltage protection,EMI-EMC as per CISPR -15,lenses for beam angle 30 deg-120deg as per the application andthe project requirementdeg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 BurningHours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified ratingand Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy 105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape size and CCTshall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing suchthat LED junction temperature shall not rise above 90°C). |
| 43 | 50 watt |
| 44 | DSR item no. 9.2Brush Less DIrect Current (BLDC) fan without remote Supply, Installation, Testing and Commissioning of ceiling fanwith Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cmlongdown rod, 2 nos. canopies, shackle kit, safety rope,copperwinding, steel/Al bodyPower Factor not less than 0.9, ServiceValue (CM/M/W) minimum as below, 350 RPM (tolerance as perIS : 374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation with regulator for speed control and allremaining accessories including safety pin, nut bolts, washers,temperature rise=75 degree C (max.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phaseAC Ceiling Fan compliant to IS 374:2019 fan Supply, earthingetc. complete as req. |
| 45 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min(Minimum) |
| 46 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole in existing wall suitable size of above fan making in original shape of wall. The size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. The Exhaust fan should be Havells/Orient and Bajaj make only. |
| 47 | Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust Fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make (EXHD380-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha make (Turbo HDEF) make only. |
| 48 | Supply and Erection of B.L Holder (ISI marked) of make Anchor Penta/ Havells (Reo)/ Goldmedal/ Lauritz Knudsen only on the existing junction box/ wooden block including making the connection etc as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work. |
| 49 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA/ PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen at 100 lm/ watt (minimum) and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The fitting should be of Philips/ Bajaj/ Wipro/ Havells/ Jaquar/ Crompton/ Panasonic/ Surya/ LT/ Trilux make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge. |
| 50 | Supplying and Erection of MCB TPN of 63 amp. The MCB TPN shall be installed in existing enclosure with suitable arrangement. The job includes cost of labour, incoming & outgoing connection and other petty material required to complete the job to the entire satisfaction of Engineer –in-charge of the work. The MCB TPN should be of Legrand/ Schneider/ Siemens/ Hager/ Havells/ ABB/ Lauritz Knudsen make only |
| 51 | Supply and erection of Sheet steel TPN MCB enclosure for MCB TPN 63 Amp. The job includes cost of labour, making connection and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work. The MCB TPN should be of Legrand/ Schneider/ Siemens/ Hager/ Havells/ ABB/ Lauritz Knudsen make only |
| 52 | S/E of 7 Meter long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 220 mm x 220 mm x 12 mm along with inbuilt lockable junction box which should be operated with single key with connectors of Elmax / Connectwell / Essen / Wago make for the cable termination and two or three terminals and one no. 6 amps. Single pole MCB for each luminaire. The diameter across from the dimensions of the base and top should be minimum 130mm and 70mm A/F (Across Face). The pole should be provided with metallic sleeve with cutting of Chandigarh ‘open hand’ mark. Sleeve should be backlit using environment proof LED modules. There should be diffused glow of open hand logo during night. Sleeve should be PU painted/ Powder coated in colour. The approx. size of the sleeve should be 1200 mm and shall be of same thickness as pole. The sleeve shall be provided at a distance of 3.5 Meter from bottom. The size of the poles and foundation bolts shall be suitable to withstand the maximum wind speed/ pressure as per IS-875. There should be no any circumferential welding on the pole. The weight of the pole should be 80 KG (Min.). The method and material shall comply with as BSEN-10025 grade S355 or equivalent poles should be hot dipped galvanized in single dip to 65 microns min. confirming to IS 2629-1966. The material and specifications of flange plate/base plate shall be as per IS 2062. The street light poles shall be as per IS 2062. The street light poles shall be erected in the existing RCC foundation with 4 nos. special foundation bolts ‘J’ type minimum M20x700mm long galvanized M.S. rod of duly threaded of minimum 20mm dia in existing RCC foundation of suitable size as per the approved drawing. The material of steel foundation belts shall be confirming to grade EN-8 exposed threaded portion of foundation bolts shall be hot dipped galvanized. The make of pole shall be Bajaj/ Transrail/ Keselec/ Valmont/ Ventura Salasar/ BPP/ Utkarsh as approved by the Engineer in charge of the work. (The cost of 7 Meter long S/L pole is including with 4 nos. ‘J’ type bolts and nuts etc.) |
| 53 | Foundation for 7 Mtr. Octagonal Pole:-Design & casting of foundation with M20 cement Concrete & steel reinforcement suitable for installation of 7 mtr. Octagonal Pole. |
| 54 | DSR ITEM NO. 2.8.1 (CIVIL WORK)Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. |
| 55 | All kinds of soil (Size 0.7m x 0.7m x 1.65 m = 0.81 cum (67 Nos. x 0.81 cum = 54.27) |
| 56 | DSR ITEM NO. 4.1.11 (CIVIL WORK)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 57 | 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size) (0.7mx0.7mx0.10m =0.049 cum.)(67 nos.x0.049 =3.283) |
| 58 | DSR ITEM NO. 5.22.6 (CIVIL WORK)Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 59 | Thermo-Mechanically Treated bars2.Vertical Bar 12mm dia =4 nos.x1.55=6.2 r.mtr. @0.89 kg per mtr. =5.52 kg3.Horizontal Ring 8mm dia =11 nos.x2=22 [email protected] per mtr.=8.58kg Total (5.52+8.58=14.1+5% =14.8 wastage = 67 nos. x14.81=992.27) |
| 60 | DSR ITEM NO. 5.2 (CIVIL WORK)Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 61 | 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) Size 0.5x0.5x1.55 = 0.388 cumTotal (67 nos.x 0.388= 25.996 cum.) |
| 62 | DSR ITEM NO. 5.9.1 (CIVIL WORK)Centering and shuttering including strutting, propping etc. and removal of form for : |
| 63 | Foundations, footings, bases of columns, etc. for mass concrete Size .5x0.5x1.5 = 4 (0.5 x 1.5) = 3 x 67 = 201 Sq. Mtr. |
| 64 | G.I. PIPE BRACKET. |
| 65 | Supply, Fabrication and Erection of G.I. Pipe (Medium Class) bracket with suitable size of nipple for mounting the 50W LED fitting with the following specifications. |
| 66 | The bracket shall be made by Medium Class GI pipe of 50mmdia with an angle of inclination 105o & 2’ feet overhang. |
| 67 | The 50mmdia G.I. pipe shall be connected to a 100mm dia G.I. pipe 45cm long canopy with top end closed with 14 G MS sheet to avoid entry of rain water in the pole. |
| 68 | The 50mm dia pipe shall be welded at a distance of 2” from the close end with 100mm dia GI pipe. |
| 69 | The canopy shall be slipped over the top section of octagonal pole & fixed with 2 Nos. ½ “ dia GI nuts & bolts. |
| 70 | A triangular 14 GMS sheet piece of 2” shall be welded between two pipes. |
| 71 | GI pipe of 32mm dia shall be welded along the arm of bracket for support and the weight of GI pipe. |
| 72 | The bracket should have also the provision of suitable size of nipple for fixing of the fitting. The job includes the cost of all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge. |
| 73 | The GI pipe should B-Class ISI marked make only. |
| 74 | The sample of bracket shall be got approved from the Engineer in Charge, before installation at site. |
| 75 | The make of Medium Class G.I pipe should be Jindal, SAIL & Tata make only. |
| 76 | Single arm bracket made out of 2” dia G.I. pipe 2’ overhang. |
| 77 | Double Arm Bracket made out of 3” dia. G.I Pipe with 2’ overhang. |
| 78 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs of 50 mm X 50 mm X 6 mm each 60 cm long M.S. angle iron each long including painting, bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high form ground level and 45 mm thick. The cubical pedestal shall be 15 cm from the top of cement concrete platform. |
| 79 | Cubical size 900 mm x 600 mm x 350 mm |
| 80 | Supply and Laying of following XLPE insulated and PVC sheathed, armoured, aluminium conductor cable of 1.1KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid on surface as required at site. The job include the cost of making connections with suitable size of Al. Lugs/thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab / Havells / Finolex / RR Kabel / KEI / RPG / Universal/ Grandlay make only. |
| 81 | 10 Sq.mm 4 Core PVC Ar. Aluminum Conductor Cable |
| 82 | 16 Sq.mm 4 Core PVC Ar. Aluminum Conductor Cable |
| 83 | 25 Sq.mm 3.5 Core PVC Ar. Aluminum Conductor Cable |
| 84 | 35 Sq.mm 3.5 Core PVC Ar. Aluminum Conductor Cable |
| 85 | DSR ITEM NO 1.17 |
| 86 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(3x2.5 sq.mm) |
| 87 | Supply and erection of sheet metal bus-bar chamber on existing surface with required No. of bus-bar strips of suitable length and cross-sectional area, made of copper strips of suitable length and cross-sectional area enclosure made of M.S. sheet 1.6mm thick with detachable cover fitted with dust excluding gasket and secured with sufficient No. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/Rag bolts and nuts etc., complete with all accessories including connections with suitable size tin coated copper thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-Charge. |
| 88 | Sheet metal bus-bar chamber suitable for 160/200 Amp. 415 Volts capacity with 4 copper strip Bus-bars each of length 680 mm & cross-sectional area (25.4mmx3.17mm) enclosure having overall dimensions (980mm x 500mm x 200mm) nominal. |
| 89 | Sheet metal bus-bar chamber suitable for 100/125 Amp. 415 Volts capacity with 4 copper strip Bus-bars each of length 680 mm & cross-sectional area (25.4mmx3.17mm) enclosure having overall dimensions (680mm x 400mm x 150mm) nominal. |
| 90 | Labour charges for cutting of road/ floor 1ft. below ground level including cost of refilling complete in all respects up to entire satisfaction of the EIC of the work. Please Enable Macros to View BoQ information |