| 1 | Civil Works |
| 2 | Scraping of cement plaster |
| 3 | 12.5 mm thick cement plaster 1:4 |
| 4 | 20mm thick cement plaster 1:4 in two coat work |
| 5 | Scraping white wash and colour wash |
| 6 | Removing old paint with caustic soda solution and preparing surface |
| 7 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 8 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 9 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 10 | Finishing walls with exterior decorative cement based paint such as snowcem,robbiacem etc. two or more coats to give an even shade |
| 11 | Applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 12 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface togive an even shade including rubbing down old paint. |
| 13 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm 4mm thick or 10.78 Kg/ sqm |
| 14 | Wire gauge Hollock wood door shutter without springs housed in chowkhat. |
| 15 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area up to 0.50 sqm |
| 16 | Terracing consiting of machine made Hollow ClayTiles 80mm thick (Smooth surface) confirming toIS: 3951 (Part-I)-2009 laid over 25 mm mudplaster 7.5 cm mud filling on another layer of25mm mud plaster including two coats of bitumenlaid hot at 1.65 Kg. /Sqm on top of R.C.C. slabincluding grouting with cement sand mortar 1:4having 10mm wide joints spacing on all sides oftiles and top surface to be left clean complete asper specification (laying shall be done as perPWD specifications). |
| 17 | Dismantling brick work tile, masonry or tile lining Dismantling dry brick work |
| 18 | Compaction of earth work & preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in theTable 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 19 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 20 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block makingmachine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. |
| 21 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled Doors of area 3 sqm and below |
| 22 | Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. &staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means) |
| 23 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level |
| 24 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 25 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge |
| 26 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in charge.UPVC 110 mm bend |
| 27 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- chargeUPVC 110 mm Coupling /Sockets |
| 28 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 29 | Providing and laying vitrified floor tiles indifferent sizes in light colour shades made usingFull Body Technology (thickness to be specifiedby the manufacturer) with water absorption’s lessthan 0.08% and conforming to IS : 15622 ofapproved make in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement: 4 finesand), complete. ( Full body vitrified tiles havepigment in entire body / thickness of tile whichmakes chips and scratches less noticeable andmake na ideal choice for high traffic zones.) |
| 30 | Precast Cement Concrete kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&specifications |
| 31 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doorsstair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 32 | Credit of materials |
| 33 | recovery of bricks |
| 34 | Taking tile |
| 35 | Brick bats from well burnt or burnt bricks |
| 36 | PH SERVICES |
| 37 | Providing & Installing 1 No. 160 mm o/d PVC straight TUBEWELL by drilling 200mm dia wtih Hand Boring up to depth of 110 m BGL, in all kinds of soil including the cost of consumable stores, fuel oil and transportation of drilling machine to the site of the proposed bore, complete in all respect |
| 38 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tubewellis lowered & tested, equipment as required such as hand boring machine and its accessory,transportationto site and vice versa etc. complete in all respect. |
| 39 | (b) Boring with 200mm id Housing Pipe |
| 40 | 0 to 150 m |
| 41 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in charge |
| 42 | (b) 150 mm nominal size dia. |
| 43 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 44 | (b) 150 mm nominal size dia. |
| 45 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 46 | Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 47 | Supplying & fixing of end capcomplete in all respects. |
| 48 | Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect |
| 49 | (b) 150 mm internal diameter |
| 50 | Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 51 | (a) Capacity of Air compressor 300 cfm at 250 PSI |
| 52 | Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 53 | Supplying & fixing of M.S. Clamp of size 200mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 54 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 55 | Providing for santary clay seal (as per BIS code IS 2500-2019) including sterlization of T/W |
| 56 | Providing, fixing, testing & commissioning (2 BHP) Submersible machinery with pump, Cable, Column pipe & Starter .etc, reputed make complete in all respects. |
| 57 | providing laying , jointing fixing and testing ISI marked PVC pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. |
| 58 | 20mm i/d |
| 59 | 25mm i/d |
| 60 | 32mm i/d |
| 61 | 40mm i/d |
| 62 | Providing fixing and jointing ISI marked gun-metal peet valves (heavey pattren ) as pewr IS 778 with hand wheels, on G.I. pipe lines laid in the ground of inside building including all carriages complete. |
| 63 | 20mm i/d gun metal peet valve heavy pattren. |
| 64 | 25mm i/d gun metal peet valve heavy pattren. |
| 65 | 32mm i/d gun metal peet valve heavy pattren. |
| 66 | 40mm i/d gun metal peet valve heavy pattren. |
| 67 | Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. |
| 68 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) infoundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 69 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 70 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS-13592 including cutting, jointing, wastage, but excluding cost of lead jointing. |
| 71 | 110mm i/d SWR UPVC pipe lines laid complete |
| 72 | 70mm i/d SWR UPVC pipe lines laid complete |
| 73 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 74 | Providing and fixing jet spray with 2'-6\\" longPVC pipe. |
| 75 | With C.P. Brass nut |
| 76 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. |
| 77 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 78 | Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling |
| 79 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 80 | C.P. brass Bib cock without flange |
| 81 | Providing & fixing in position C.I gully trap cover weighing approximately 7.26 kg and frame for gully trap camber clear opening size 300mm x 300mm and outside size 330mmx330mm including painting the exposed surface with 3 coats of black bit mastic superior paint of approved make (to the approval of Engineer-in charge). |
| 82 | Providing & Fixing H.C.I. floor traps conforming to ISI specification (IS:1729) of approved make (to the approval of Engineer-In-Charge) of the self cleaning design with CP brass hinged grating with fram eith or without vent arm and including cement concrete 1:2:4 under and around the floor level complete in all respects including cutting and making good the walls and floors etc. minimum depth of water should be 150mm with a minimum seal 50mm. |
| 83 | (b) with 75mm i/d outlet deep seal. |
| 84 | Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 85 | Heal Rest Bend (100mm) |
| 86 | Heal Rest Bend (75mm) |
| 87 | Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 88 | Cowls |
| 89 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 90 | Providing & fixing in position on terrace (at allfloor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer -in-charge) complete in all respect. |
| 91 | For 1000 ltr capacity tank and above |
| 92 | ELECTRICAL SERVICES |
| 93 | Internal Electrical Installations |
| 94 | RECESSED PVC CONDUIT PIPE WIRING SYSTEMWITH MODULAR SWITCHES: |
| 95 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:- |
| 96 | Wiring fan point (Without fan box) |
| 97 | Wiring light point |
| 98 | Wiring 6Amp. wall socket point |
| 99 | Wiring 6Amp. Plug control comprising wall socket point |
| 100 | Wiring 16/20Amp. power plug control point |
| 101 | RECESSED AIR CONDITION SUPPLY TERMINAL POINTS: |
| 102 | Wiring air condition supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- |
| 103 | Wiring AC supply terminal points having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 104 | RECESSED COMPUTER SUPPLY TERMINAL POINTS: |
| 105 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- Accessories |
| 106 | Wiring Computer terminal points having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator and 2No. blanking plate (Modular accessories). |
| 107 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 108 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 109 | Overall size 1.5sq.mm (Un-sheathed) |
| 110 | Overall size 2.5sq.mm (Un-sheathed) |
| 111 | Overall size 4sq.mm (Un-sheathed) |
| 112 | Overall size 6sq.mm (Un-sheathed) |
| 113 | Overall size 10sq.mm (Un-sheathed) |
| 114 | COPPER EARTHING: |
| 115 | 8 SWG COPPER EARTHING : |
| 116 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A- Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length).G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:- |
| 117 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 118 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 119 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs. |
| 120 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 121 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 122 | SHEET METAL DOUBLE DOOR DISTRIBUTIONBOARD FOR MCB/ RCBO/ RCCB's: |
| 123 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: |
| 124 | SP&N Double Door Distribution Board 12 way each |
| 125 | XLPE INSULATED UN-ARMOURED CABLES (ONSURFACE): |
| 126 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 127 | Overall size 16sq.mm (2Core) Un-armoured (On- Surface) |
| 128 | SHEET METAL BUS BAR CHAMBERS (COPPERSTRIPS): |
| 129 | Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross- sectional area mounted on DMC/ SMC moulds at sufficient distance enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- |
| 130 | Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal |
| 131 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 132 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 133 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in- charge at site. |
| 134 | SITC of Wall Fan Size 400MM complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 135 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in charges at site. |
| 136 | Providing Flood Lighting |
| 137 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 138 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 139 | Overall size 1sq.mm (Un-sheathed) |
| 140 | Overall size 1.5sq.mm (Un-sheathed) |
| 141 | XLPE INSULATED UN-ARMOURED CABLES (ONSURFACE): |
| 142 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 143 | Overall size 10sq.mm (3Core) Un-armoured (On- Surface) |
| 144 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 145 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs. |
| 146 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 147 | Supply and erection of SMC FRP (Glass Fibre reinforced polyester sheet moulding compound conforming to IS:13410) Junction Box (Recessed/ On surface) conform to IS:14772, robust constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site. |
| 148 | SMC FRP (Glass Fibre reinforced polyester sheet moulding compound confirming to IS:13410) Junction Box conform to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 149 | SHEET METAL IRON CLAD SWITCHES: |
| 150 | Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- |
| 151 | ICDP Switch 32amp., 415volts |
| 152 | Supply and erection of LED Flood Light 50 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty Including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. Please Enable Macros to View BoQ information |