| 1 | Cutting/Excavation in earth work by mechanical means (Hydraulic Excavator/manual means in all heights and depth in all kind of soil including saturated soil comprising of pick wok, jumper, Chiselling/wedging out of in soft and hard rock and their intermideate classification of soils including dewatering wherever required, setting out to required lines, levels as shown shown on the drawing as directed by the Engineer- in -charge at site, according to the HPPWD specification of 1990 vol-1 as sorting out usefull and unuseful material and stacking the same in all lead and lift and leveling of excavated earth on dumping sites (to be arranged by the contractor at his own risk and cost including payment of prescribed dumping charges of municipal committee/local body if any) through all modes of transportation including head load animal load and mechanical transportation to maximum possible extends in all leads means along with levelling fine dressing and all labour, machinery, materials, tools equipments and safty measure and incidentels necessary to complete the work by mechanized means and labour (if any required). All useful materials such as stone, shingles, aggregate and slates shall be sorted along road side and lift through all modes of transportation and used/removed as per direction of the Engineer-in-charge. Any loss to the private and public property during the course execution will be restored by the contractor whatsoever the nature of the same may be. The usable aggregate/ boulder /cutstone shall be taken in MAS Account anf further will be issued to the contractor as per issue rate mentioned under condition No. 46 of NIT Form 6. |
| 2 | Excavation in earth work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains in all depth, all kind of soil including saturated soil comprising of pick wok, jumper work, Chiseling/ Wedging out of soft and hard rock and their intermiate classification of soils including dewatering wherever required, setting out to required lines, levels as shown on the drawing as directed by the Engineer-in-charge at site, according to the HPPWD specification of 1990 vol-1 as sorting out use full and unuseful material and stacking the same in all lead and lift and leveling of excavated earth on dumping sites (to be arranged by the contractor at his own risk and cost including payment of prescribed dumping charges of municipal committee/local body if any) through all modes of transportation including head load animal load and mechanical transportation to maximum possible extends in all leads means along with levelling fine dressing and all labour, machinery, materials, tools equipments and safty measure and incidentels necessary to complete the work by mechanized means and labour (if any required). All useful materials such as stone, shingles, aggregate and slates shall be sorted along road side and lift through all modes of transportation and used/removed as direction of the Engineer- in- charge. Any loss to the private and public property during the course execution will be restored by the contractor whatsoever the nature of the same may be. The usable aggregate/ boulder /cutstone shall be taken in MAS Account anf further will be issued to the contractor as per issue rate mentioned under condition No. 46 of NIT form 6. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)i/c civil work and carriage of material in all leads and lifts. |
| 4 | 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)i/c civil work and carriage of material in all leads and lifts. |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size) i/c civil work and carriage of material in all leads and lifts. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns i/c civil work and carriage of material in all leads and lifts. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for :Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. i/c civil work and carriage of material in all leads and lifts. |
| 8 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. i/c civil work and carriage of material in all leads and lifts. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for all heights. Suspended floors, roofs, landings, balconies and access platform. i/c civil work and carriage of material in all leads and lifts. |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers i/c civil work and carriage of material in all leads and lifts. |
| 11 | Columns, Pillars, Piers, Abutments, Posts and Struts i/c civil work and carriage of material in all leads and lifts. |
| 12 | Edges of slabs and breaks in floors and walls Under 20 cm wide i/c civil work and carriage of material in all leads and lifts. |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding with PVC cross lock all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more i/c civil work and carriage of material in all leads and lifts. |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding PVC cross lock all complete above plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more. i/c civil work and carriage of material in all leads and lifts. |
| 15 | Providing and laying in design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works upto plinth level. i/c civil work and carriage of material in all leads and lifts. |
| 16 | Providing and laying in design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability and including waterproofing treament on slab as per direction of Engineer-in-charge.All works above plinth level. i/c civil work and carriage of material in all leads and lifts. |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor all level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) i/c civil work and carriage of material in all leads and lifts. |
| 18 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) i/c civil work and carriage of material in all leads and lifts. |
| 19 | Stone soling properly hand packed filling interstices with spalls and consolidating with hand ramming including spreading watering and rolling of binding materials moorum or earth etc. complete as per H.P.P.W.D. specifications. 100mm spread thickness (finished work including materials and labour) i/c civil work and carriage of material in all leads and lifts. |
| 20 | Providing and fixing Ist quality ceramic glazed Floor & wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in floor, skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. i/c civil work and carriage of material in all leads and lifts. |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length. 2nd class deodar wood |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick i/c civil work and carriage of material in all leads and lifts. |
| 23 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.2nd class deodar wood. i/c civil work and carriage of material in all leads and lifts. |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws i/c civil work and carriage of material in all leads and lifts. |
| 25 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16mm i/c civil work and carriage of material in all leads and lifts. |
| 26 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250mmx10mm i/c civil work and carriage of material in all leads and lifts. |
| 27 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm i/c civil work and carriage of material in all leads and lifts. |
| 28 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper i/c civil work and carriage of material in all leads and lifts. |
| 29 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.i/c carriage of material in all leads and lifts. |
| 30 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position in grills and applying a priming coat of approved steel primer all complete. i/c carriage of material in all leads and lifts. |
| 31 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces i/c carriage of material in all leads and lifts. |
| 32 | Providing and laying vitrified floor and skirting tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete i/c carriage of material in all leads and lifts. |
| 33 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) i/c carriage of material in all leads and lifts. |
| 34 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) i/c carriage of material in all leads and lifts. |
| 35 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) i/c carriage of material in all leads and lifts. |
| 36 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer i/c carriage of material in all leads and lifts. |
| 37 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture. i/c carriage of material in all leads and lifts. |
| 38 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. i/c carriage of material in all leads and lifts. |
| 39 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. i/c carriage of material in all leads and lifts. |
| 40 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. i/c carriage of material in all leads and lifts. |
| 41 | Wall paintingwith plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work i/c carriage of material in all leads and lifts. |
| 42 | Providing & fixing White vitreous china water closet squatting pan (Indian type) including PVC Cistern 5 ltrs capacity along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. i/c carriage of material in all leads and lifts. |
| 43 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid i/c carriage of material in all leads and lifts. |
| 44 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar taps. i/c carriage of material in all leads and lifts. |
| 45 | Providingandfixing8mmdiaC.P. /S.S.Je twith flexible tube upto 1metre longwithS.S. triangular plate to EureopeantypeW.C.ofqualityandmakeasapproved by Engineer - in - charge. i/c carriage of material in all leads and lifts. |
| 46 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32mm i/c carriage of material in all leads and lifts. |
| 47 | Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge.1216 (16 mm OD) pipe. i/c carriage of material in all leads and lifts. |
| 48 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore i/c carriage of material in all leads and lifts. |
| 49 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length i/c carriage of material in all leads and lifts. |
| 50 | Providing and fixing PTMT grating of approved quality and colour. i/c carriage of material in all leads and lifts. |
| 51 | Providing and fixing square-mouth S.W.gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: i/c carriage of material in all leads and lifts. |
| 52 | Providing and fixing PVC floor trap ISI marked of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. complete. 110 mm X 75 mm i/c carriage of material in all leads and lifts. |
| 53 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete.75 mm dia. i/c carriage of material in all leads and lifts. |
| 54 | 110mm dia . |
| 55 | Providing and fixing Chest Press Technical Specification Size 2500X 800X 2000 Main frame 100mm OD GI pipe Frame & Handle- 40mm & 31mm OD G.I. pipe. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 56 | Providing and fixing Wheel/ Shoulder Twirl Technical Specification:Size 1450X 520X 1750 Main frame 80mm OD GI pipe Frame & Handle-25mm OD G.I. pipe. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 57 | Providing and fixing HandRower Technical Specification: Size 1200X 800X 700 Main frame: 100mm OD GI pipe Structure: 80mm OD G.I. pipe. movement: 31mm OD G.I.pipe Handle: 25mm OD G.I. pipe. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 58 | Providing and fixing Back Extension Technical Specification: Size 1060X 730X 990mm Main frame 100mm OD GI pipe Foundation plate-M.S. Round Plate of 250mm and 8mm Thick or more Seat Rest Pipe / Seat : GI Pipe 42mm OD or more Seat Rest and Foot Rest: Perforated Galvanished Seat Having Wall Thickness of 2mm as per standred. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 59 | Providing and fixing Shoulder Exerciser Technical Specification:Size 1600X 300X1200 Main frame: 80mm OD GI pipe Structure: 31mm& 25mm OD G.I. pipe. Handle: 25mm OD G.I. pipe Revolving Seat : MS Sheet. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 60 | Providing and fixing Aerial Stroller Technical Specification:Size 100X 550X1480 Main frame: 100mm OD GI pipe PipeU: 80mm OD G.I. pipe. Leg movement:40mm OD G.I.pipe Handle: 31mm OD G.I. pipe. Metal Paint:Powder Coated. All open ends of pipe are tobe close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 61 | Providing and fixing Leg Extension Technical Specification:Size 1060 MM X 730 MM X 990 MM or as per manufacturer design Main frame 100 MM or more Foundation plate-M.S. Round Plate of 250mm and 8mm Thick or more Arm handle & Rest Seat frame :32/50 NB GI Pipe With 2.65mm Thickness as per standard design Back & Rest Seat & Foot Rest: Perforated Galvanished Seat Having Wall Thickness of 2mm with Precision Punched Hole of 10mm Dia / Cast Iron 325 x 270 x 8 mm thick and M.S Plate of 250 x 200 x 2mm Thick as per standard design Handle Pipe: 33mm OD GI Pipe or more Leg Support :42mm OD GI Pipe or more Seat Rest Pipe: 42mm OD GI Pipe or more Foot Rest Pipe : 42mm OD G.I. Pipe and 80 x 40 mm MS Rectangular Pipe. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. |
| 62 | Providing and fixing Sky Walker Technical specification: Size 850X800 X 1800 Main frame: 80mm OD GI pipe Leg movement:40mm OD G.I.pipe Handle & Leg: 31mm & 25mm OD G.I. pipe Foor rest : MS Sheet2mm. Metal Paint:Powder Coated. All open ends of pipe are to be close by GI/PVC caps for user safety against entrapment. i/c civil work and carriage of material in all leads and lifts. Please Enable Macros to View BoQ information |