| Sl. No. | Item Description |
| 1 | SITE CLEARANCE |
| 2 | 2.33.1Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks andbranches, removing the roots and stacking of serviceable material and disposal of unserviceablematerial.Beyound 30 cm girth up to and including 60 cm girth |
| 3 | 2.32Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the areacleared. |
| 4 | 2.28.1Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cmdeep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 5 | NEW BUILDING WORK |
| 6 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundationtrenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides andramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplusexcavated soil as directed, within a lead of 50 m.All kinds of soil |
| 7 | 15.3Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposalof unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 8 | 15.7.4Demolishing brick work manually / by mechanical means including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.Incement mortar |
| 9 | 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good qualityblasted rubble including packing to compactness to lines and levels cost and conveyance of all materialslabour charges etc. complete as per direction of Departmental officers at site |
| 10 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 mand lift up to 1.5 m. |
| 11 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size) |
| 12 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost ofcentering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarsesand :3 graded stone aggregate 20 mm nominal size |
| 13 | 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinthand string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five levelexcluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 14 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floorfive level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 15 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases ofcolumns, etc for mass concrete |
| 16 | 5.9.16.1Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks infloors and wallsUnder 20 cm wide |
| 17 | 5.9.19Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbelsetc., including edges |
| 18 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platform |
| 19 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,girders bressumers and cantilevers |
| 20 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 21 | 50.6.7.2Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cementmortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labourcharges etc. |
| 22 | 50.6.3.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest availablesize confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in :CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 23 | 9.48.1Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square orround bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows bywelding |
| 24 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built upstandard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up thegaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium(minimum thickness of powder coating 50 micron) |
| 25 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDMrubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0mm thickness |
| 26 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded woodparticle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architecturaldrawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative laminationon both sides |
| 27 | 13.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 28 | 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) |
| 29 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labourcharges etc complete |
| 30 | 5.30Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. |
| 31 | 22.23.2Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to theRCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage& water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystallineslurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with thehelp of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capableof self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guaranteefor 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 32 | 13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as permanufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and includingone coat of special primer applied @ 0.75 ltr /10 sqm |
| 33 | 13.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as permanufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade.Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm ofapproved brand and manufacture |
| 34 | 11.38Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by themanufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, exceptWhite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 35 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specifiedby the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black ofany size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bedof cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm,including pointing in white cement mixed with pigment of matchingshade complete. |
| 36 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours andshades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the jointswith white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 37 | 11.20.2Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cementslurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Medium shade pigment using 50% whitecement 50 % Grey cement |
| 38 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting thesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of thefloor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc.) |
| 39 | 9.117.1Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overalldimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frameto be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. Thehinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer'sspecification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm |
| 40 | 9.118.1Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of stylesand rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S.galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats.The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, havingover all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar attwo places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers,complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. andbathroom door shutter). |
| 41 | 50.6.7.1Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cementmortar 1:6 for foundation and basement including all cost of materials, labour charges etc. |
| 42 | 50.10.1Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 43 | 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete |
| 44 | 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation asapproved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 gramsper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum toavoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm)with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. |
| 45 | 10.30.1Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows allcomplete with :4.0 mm thick glass panes |
| 46 | PLUMBING WORK AND SANITARY FITTINGS |
| 47 | 17.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling ofapproved municipal design complete, including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 48 | 17.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass wasteof standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brasspillar tap |
| 49 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 50 | 50.18.7.4.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall |
| 51 | 50.18.8.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 25 mm pipe 12 kgf/cm2 |
| 52 | 50.18.9.16.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall |
| 53 | 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Elbow |
| 54 | 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVCsolvent cement - 63x63x63 mm dia Tee |
| 55 | 50.18.9.20.6Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -63x63x63 mm dia Door Tee |
| 56 | 50.18.9.20.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia vent cowl |
| 57 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110 mm dia Elbow |
| 58 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVCsolvent cement 110x110x110 mm dia Tee |
| 59 | 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110x110x110 mm dia Door tee |
| 60 | 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -110 mm dia Vent cowl |
| 61 | 50.18.9.7.1Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling& testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 |
| 62 | 50.18.9.9.2Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 63 | 18.15.1Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 64 | 50.17.1.1Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etccomplete as per the direction of site Engineer-in-charge. |
| 65 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials andlabour charges etc complete as per the direction of site Engineer-in-charge. |
| 66 | 50.17.1.4Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc.complete as per the direction of site engineer-in-charge. |
| 67 | PLUMBING WORK AND SANITARY FITTINGS |
| 68 | 90.1.1.1Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part IIIin roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the reinforcement etc. as required.20 mm |
| 69 | 90.2.2.1Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Single Control light point with6A, plate ceiling rose - Short point |
| 70 | 90.2.2.3Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Single control light pointwithout ceiling rose - Short point |
| 71 | 90.2.2.4Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Single control ceiling fan pointwith 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point |
| 72 | 90.2.2.5Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Call bell point with 6 A bellpush at one end and 6 A, 3 plate ceiling rose at other end - Short point |
| 73 | 90.2.2.6Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Combined plug point with 6 A,5 pin plug socket controlled by 6 A switch in the same switch board as that of light points. |
| 74 | 90.2.2.7Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providing switch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SP switches and making goodthe surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shallbe tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (Group B/ RoHS compliant modular accessories).Independent plug - Short point |
| 75 | 90.3.18.2Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut andwelded to shape and fixing the same to wall / parapet using clamps as noted along with each size,painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good thedamages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 76 | 90.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation,testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet completewith all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MSflat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required.1200 mm 1X20W LED Lamp with box type fixture |
| 77 | 90.4.5.2Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes usingstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVCinsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackles and blades working on 230V/240V single phase A/C |
| 78 | 90.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and givingconnections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVCsheathed round copper conductor flex wire conforming to relevant ISS or with the extended originalwiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 79 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 80 | 90.10.3.14Supply and Fixing the following modular switches & accessories in the existing front plates and givingnecessary connections as required (RoHS compliant )25A SP switch with indicator |
| 81 | 90.10.3.32Supply and Fixing the following modular switches & accessories in the existing front plates and givingnecessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 82 | 90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greaterthan 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer) |
| 83 | 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required2.00 mm copper conductor ( 14 SWG) |
| 84 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) |
| 85 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.3.15 mm (10 SWG) |
| 86 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andprovidingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required. |
| 87 | 2.3.1Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6way, Double door |
| 88 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 89 | 2.10.3Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Double pole |
| 90 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 91 | 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.25 amps |
| 92 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door |
| 93 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 94 | 1.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm |
| 95 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 96 | 1.17.13Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm |
| 97 | 1.17.20Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 98 | 1.17.22Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 99 | 1.17.29Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm |
| 100 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch |
| 101 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 102 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modularplate as required. |
| 103 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 104 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required . 3 Module (100mmX75mm) |
| 105 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess,including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modularswitches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 106 | 1.57Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recessincluding providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve includingconnections, painting etc. as required. |
| 107 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 108 | od301360/2023_2024Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in theexisting opening, fixing necessary bolt and nuts, making good the damages etc. as required includinggiving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core roundcopper conductor flex wire conforming to relevant ISS. -200 mm, single phase light duty exhaust fan inPlastic frame ( Light duty exhaust fan) |
| 109 | od301363/2023_2024Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 110 | od301364/2023_2024Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 111 | od301366/2023_2024Providing and fixing of 200mm plastic shade on existing batten/angle/pendant/bracket fittings as required |
| 112 | od301367/2023_2024Supply and fixing 9 w LED Bulb on existing lamp holder B22 |
| 113 | od301368/2023_2024Fabrication, supply and installation of wall mounting powder coated open type GI meter box of followingsize suitable for fixing single phase energy meter, Kit cat fuse, Neutral link etc. hinged door construction,knock out for cable entry etc. as required |
| 114 | od301369/2023_2024Supply and providing suitable iron hook grouted on the ceiling for hooking the ceiling fan. |
| 115 | od301370/2023_2024Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled ellipticalshaped bulk head fittings directly on wall including cutting necessary holes, giving connections with theextended orginal wiring, making good the damgaes, colour washing etc as required. |
| 116 | od74636/2024_2025Supply and installation of ISO / BIS Certified IGBT technology based 5KV Online UPS with minimum 5years on-site warrnty and having the following minimum specifications. 1. Output : 230V+ 1% 50Hz sinewave single phase.2. Input : 170V to 270V 50HzAC freequency 50Hz 3. Rating :5KVA, 4. Backup time :Minimum2Hrs. on full load, 5. Efficiency : 90% or Higher, 6. Battery bank : 150VAH or Higher tubularbattery withminimum 5 years warranty with suitable battery rack 7. Protection : Over load, short circuit,battery reverse polarity, input volage below or above the specified range over discharge or charge ofbattery, Accepted model : Hykon or eqivalent brand with better specification. |
| 117 | od75467/2024_2025Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required4x4 sq mm (16mm) |
| 118 | od75468/2024_2025Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired. 4 X 6 sq. mm (19mm) |
| 119 | 2.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8way, Double door Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail