| 1 | Electrification |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | 1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 5 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 6 | OD346543/2025-2026:Supply, conveyance, installation, testing and commissioning of LED Bulk head light fittings 9W or nearest wattage directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS making good the damages, colour washing etc as required. |
| 7 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 8 | 90.3.21.4:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 2x20W LED Lamp with box type fixture |
| 9 | OD345198/2025-2026:Supply, conveyance and fixing LED foot light fittings (2/3module) complete with all accessories in existing modular box giving connections with the existing wire etc., as required |
| 10 | OD345199/2025-2026:Supply, conveyance, installation, testing and commissioning of Philips single fancy light fitting Philips Vase or black and glass synthetic or metal grey and synthetic or equivalent make of all types with 9W LED bulb directly on wall/ ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. |
| 11 | OD345200/2025-2026:Supply, conveyance, installation, testing commissioning of 5 watts, LED mirror lamp, Operating Voltage: 160-360 volts Philips, Crompton or equivalent make |
| 12 | OD345071/2025-2026:Supply,Conveyance, installation, testing and commissioning of 800 lumen round/square surface/recess fitting made of die cast aluminum, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10% directly on ceiling and giving connections with 16/0.20mm 3 core PVC insulated and sheathed round copper conductor flexible wire or extending the original wiring and giving connections as required.(Chip make Cree/Osram/lumilled/Nichea) or equivalent make |
| 13 | OD346561/2025-2026:Supply, conveyance, installation, testing and commissioning of 2Meter LED profile with Strip light and aluminum profile , drive for 2Mtr fixing on exiting Ceiling including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. |
| 14 | OD345061/2025-2026:Supply, conveyance, installation, testing and commissioning of 6W LED out door Wall up down light water proof lamp (warm White) directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required. |
| 15 | OD345064/2025-2026:Supply, conveyance, installation, testing and commissioning of 15W LED Hanging ceiling light fittings of all types directly on Ceiling including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. |
| 16 | OD345063/2025-2026:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light with IP 65 protection and Aluminum pressure die-cast Powder coated housing, acrylic cover complete power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply and giving connection using required length of 16/0.20mm 3core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring etc as required |
| 17 | OD345226/2025-2026:Supply and providing 30W LED post top lantern made in die-cast aluminum with innovative glare free indirect lighting distribution and IP 54 protection suitable for the lighting of open place and giving connections etc : as required including painted base plate with suitable size pipe and 4Nos anchor blot for fixing the fitting on existing bridge concrete pillar. (BRIL 45W LED NW Bajaj/Havells/Philips make or equivalent) |
| 18 | 90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe |
| 19 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 20 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 21 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 22 | 1.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 23 | OD345057/2025-2026:Supply, conveyance, installation, testing and commissioning of 400/450mm sweep wall mounting fans with metallic blades, blade covers, body using mounting brackets supplied along with the fan and giving connection as required. |
| 24 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 25 | OD346574/2025-2026:Supply, conveyance, installation , testing and commissioning of 225/250 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 26 | OD345067/2025-2026:Supply, conveyance, installation , testing and commissioning of 250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C , fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 27 | OD345225/2025-2026:Supply and fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required(RoHS Compliant). 20A Energy key tag |
| 28 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 29 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 30 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 31 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 32 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 33 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 34 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 35 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 36 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 37 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 38 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 39 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 40 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 41 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 42 | OD345232/2025-2026:Supplying and fixing following rating, Double pole, Centre off MCB Change over in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 43 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 44 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 45 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 46 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 47 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 48 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 49 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 50 | 90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm |
| 51 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 52 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 53 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 54 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 55 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 56 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 57 | OD345062/2025-2026:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 58 | OD345070/2025-2026:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 59 | OD345066/2025-2026:Supply and providing 25x6mm brass bolt |
| 60 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 61 | OD345069/2025-2026:Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board( GS-MB- 3525) and to fix KSEB meters, fuse units, etc as required including fixing it on wall, making good the damages colour washing etc. as required. |
| 62 | OD345072/2025-2026:Supply and fixing 32A Cutout Fuse with 16/20/25A HRC Link connection in existing meter board |
| 63 | OD345058/2025-2026:Supply and fixing 32A 2Way neutral link with connection in existing meter board |
| 64 | OD345059/2025-2026:Supply and providing suitable Iron Hook Grouted on wall for binding the service wire |
| 65 | OD345223/2025-2026:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming io IS fitted with rotary compressor operating on 230V single phase AC supply,R32/equilent refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remotecontrol etc 1.5 Tr 3 star single phase Inverter type split AC unit having cooling capacity greater than or eaqual to 5000W including Cu pipe connection & electric cabling fromindoor to outdoor unit upto 3m with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete (Mistubushi/Bluestar/Daikin) |
| 66 | OD345224/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V Guard/Sinzon/Everset) |
| 67 | OD345231/2025-2026:Supply and providing 5 star rated 10Ltr water heater with nylon hose and giving connections (V-Guard / Racold ) |
| 68 | OD346578/2025-2026:KSEB charge for 2Nos New service connection etc including preparing necessary doucuments for submitting to KSEB, online/ofline submition and arranging inspection of KSEB if required (Actual amount will be reimbursed on production of receipts) the item is non competition item and the approved amount Rs 18400/- Please Enable Macros to View BoQ information |