| 1 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m .a) In ground floor including roof |
| 2 | Dismantling all types of masonry excepting cementconcrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directedwithin a lead of 75 m. a) In ground floor including roof |
| 3 | Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m. In ground floor including roof.(a) upto 150 mm. Thick |
| 4 | Dismantling R.C. floor, roof, beams etc. includingcutting rods and removing rubbish as directedwithin a lead of 75 m. including stacking of steelbars. (a) In ground floor including roof. |
| 5 | Labour for taking out door and window frame including shutter for repair orreplacement of different parts of the frame & refixing the same including mendinggood all damaes complete. (Concrete and brick work for mending damage will bepaid separately) . (a) Upto area 2.5 Sq.m(i) gr.floor |
| 6 | Labour for taking out steel door and window frame for repairs andre-fixing the same (or replacement by new one) including mendinggood damages (excluding the cost of repair of damages) andapplying a protective coat of paint.Upto one sq.m.area of frame. |
| 7 | Taking out heavy iron grated door or window (jail pattern orexisting) with locking arrangement after cutting out from walls andrefixing the same including mending all damages.[Mending chargesto be paid separately] |
| 8 | Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels,sraightening bent bars and rivetting with new rivets and fitting inposition and painting two coats. |
| 9 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) |
| 10 | Repairs to cracks in terraced roof by cutting V-grooves 75 mm. to 100 mm. deep and 150 mm. to 200 mm. wide and filling the same with beaten lime concrete (2:2:7) with lime putty / paste and finishing complete (2 lime putty / paste : 2 surki : 7 brick khoa ) |
| 11 | Labour for painting roof surface with Bitumen (using 135 kg (avg.) per % Sq.m.)including cleaning roof, heating bitumen as directed and spreading sand and complete including cost of sand @ 0.6 cu.m. per % Sq.m. and cost of carriage of Bitumen from deptt godown but excluding the cost of bitumen. (If heating is not reqd. then deduct Rs.3.45/- per Sq.m) |
| 12 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] |
| 13 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby includingpointing in cement slurry with admixture of pigment matchingthe stone shade, including grinding & polishing as perdirection of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m] |
| 14 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 15 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. |
| 16 | Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor (A) [Pakur Variety] (a) 1:3:6proportionr and foundation. |
| 17 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominalsize excluding shuttering and reinforcement,if any, as per relevant IS codes. Pakur variety .In Ground floor |
| 18 | Extra rate for using water proofing and plasticising admixture @ 0.2% byweight of cement (or at manufacturer's specified rate) for concrete of variousgrades. |
| 19 | Brick work with 1st class bricks in cement mortar (1:6) .In superstructure . a)in foundation &plinth |
| 20 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. a) In ground floor |
| 21 | Welding in M.S. structural work with gas or electric: (a) tack weld |
| 22 | Welding in M.S. structural work with gas or electric:(b) continuous weld |
| 23 | Labour for lowering and stacking after dismantling in parts R.S.joists, channels, angles, tees, plates etc.complete as directed |
| 24 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including, rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including threading nosing and drip course where necessary.i) With 1:6 cement mortar.a) 20 mm thick plaster.In ground floor |
| 25 | 15 mm th.b.1) In ground floor. |
| 26 | b.2) In first floor |
| 27 | ii) With 1:4 cement mortar.c) 10 mm thick plaster. 1) In ground floo |
| 28 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 29 | Applying Interior grade Acrylic Primer of approved quality and brand von plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) .a) One Coat . i) Water based interior grade Acrylic Primer |
| 30 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) ii) i) Standard Quality |
| 31 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C (i) One coat In ground floor |
| 32 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.b) Premium 100% Acrylic Emulsion1)In Ground floor (Two Coat) |
| 33 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 34 | a ) Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 35 | b ) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 36 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) |
| 37 | (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white). |
| 38 | Cleaning glazed tiles with acid |
| 39 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) . (i) 3 mm thick (weighing 7.4 kg/Sq.m) |
| 40 | Easing and oiling, cleaning collapsible gate and repairing to locking arrangements. |
| 41 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.22.5 Kg./m |
| 42 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or bothfaces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 43 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting,fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed Work PVC Pipes15 mm |
| 44 | 20 mm |
| 45 | 25 mm |
| 46 | 32 mm |
| 47 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 48 | (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 49 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 50 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer . (b) 1500 litre capacity |
| 51 | Labour for hoisting plastic water storage tank(i) Upto 1500 litre capacity |
| 52 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 53 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approvedquality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint .(ii) 550 mm X 400 mm size |
| 54 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak |
| 55 | Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will beinserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete |
| 56 | Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage ofall materials, taxes and all other incidental charges complete. |
| 57 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.(ii) 110 mm. Dia |
| 58 | c) Bend 87.5 degree |
| 59 | d) Shoe . ii) 110 mm. Dia |
| 60 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. c) Upto 50 users:- .(ii) Beyond a lead of 150 metre and outside the Municipal limit |
| 61 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 62 | Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbared wire fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples, straining bolt and binding wire as necessary.(Payment to be made on lengh of individual lines of wire.) |
| 63 | Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete.(i) 10 mm dia.(b) 200 mm. |
| 64 | Supplying galvanised staples fitted and fixed complete. Please Enable Macros to View BoQ information |