| 1 | Surface excavation excavation not exc 30cm deep and getting out in soft/loose soil complete all as specified and directed |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil) complete all as specified and directed |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm In soft to loose soil complete all as specefied and directed. |
| 4 | Removing excavated soil not xxc. 50m and depositing where directed at a level n exc. 1.5 m above ehe starting point complete all as specified and directed |
| 5 | M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and directed |
| 6 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed |
| 7 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed |
| 8 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed |
| 9 | M&L PCC (1:4:8) type D2 using (40mm graded aggregate) in foundation complete all as specified and directed |
| 10 | M&L for formwork to sides of concrete foundations, footings, bases of columns, plinth beam and similar work fair finished surface complete all as specified and directed |
| 11 | M&L for formwork to sides of pillars, posts, columns etc in square, rectangular and similar work fair finished surface complete all as specified and directed |
| 12 | M &L, Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed |
| 13 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed |
| 14 | M & L RCC (design mix) M-25 ( 20mm graded agg) as in foundation, including rafts, plinth beams, footings complete all as specified and directed |
| 15 | M&L for reinforced cement concrete (design Mix) M-25 (20mm graded aggregate) as in Lintels, chajjas & roof beam complete all as specified and directed |
| 16 | M & L RCC (design mix) M-25 ( 20mm graded agg) as .Columns, pillars, piers, posts and struts complete all as specified and directed |
| 17 | M&L for reinforced cement concrete (design Mix) M-25 (20mm graded aggregate) as in slabs complete all as specified and directed |
| 18 | Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed |
| 19 | Supply and fix TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed |
| 20 | M&L for brick work with old sized fly ash bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed |
| 21 | M & L for brickwork with old sized flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed |
| 22 | M&L for rendering in two layer on fair faces of brick work or concrete surfaces of wall 5 mm thick in CM (1:4) mixed with WPC as per manufacturer's instructions of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 complete all as specified and directed. Note - WPC shall be measured and paid seprately. |
| 23 | M&L for 5mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed. |
| 24 | M&L rendering 10mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed |
| 25 | Supply Only water proofing compound complete all as specified and directed |
| 26 | Material & Labour for preparation of new plastered surfaces of walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 27 | M&L three coats of white wash all as specified on ceilings, etc complete all as specified and directed |
| 28 | M&L for two coats of oil bound distemper over one coat of wall primer over avg 2mm thick wall care putty all as specified with approved colour pattern on walls, beams, soffits, columns, etc. complete all as specified and directed |
| 29 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 mm2 and resistance to spread of flame of Class A category with property of being mite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and including fixing in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madeThe work for WPC frames shall include the following and the rates quoted by the bidder shall include the same-(aa) The work pertaining to WPC frames shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like WPC board, SS screws etc after approval by the GE.(ab) The contractor shall upload with the documents under cover-I \\"Memorandum of Understanding\\"(MoU)with at least one of the manufacturers mentionedin the contract, failing which the bid shall be liable to be rejected. |
| 30 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 mm2 and resistance to spread of flame of Class A category with property of being mite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and including fixing in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madeThe work for WPC frames shall include the following and the rates quoted by the bidder shall include the same-(aa) The work pertaining to WPC frames shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like WPC board, SS screws etc after approval by the GE.(ab) The contractor shall upload with the documents under cover-I \\"Memorandum of Understanding\\"(MoU)with at least one of the manufacturers mentionedin the contract, failing which the bid shall be liable to be rejected. |
| 31 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and including supplying and fixing with stainless steel butt hinges of 100mm size with necessary full body threaded star headed counter sunk S.S screws, and 4 no. stainless steel butt hinges complete all as specified and directed.The work for WPC frames shall include the following and the rates quoted by the bidder shall include the same.(aa) The work pertaining to WPC frames shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like WPC board, SS screws etc after approval by the GE.(ab) The contractor shall upload with the documents under cover-I \\"Memorandum of Understanding\\"(MoU)with at least one of the manufacturers mentionedin the contract, failing which the bid shall be liable to be rejected. |
| 32 | Supply and Fixed Providing 30mm thick FACTORY MADE WIRE MESH SOLID WPC PRELAM DOOR SHUTTER with lamination consisting of Density 650 Kg /Cum Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh (G-304) 0.36mm minimum dia of wire and average width of aperture 1.40mm shall be fixed with 15x15 mm square tube inside rails with screwing 8x28mm heat metal zinc coated screws and XPM aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity including supplying and fixing to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws and 2 mm thick edge moulding tape or 90 degree edge bend finish etc. complete as per manufacturer's specification & drawings. complete all as specified and directed. The work for wpc shutter shall include the following and rates quoted by bidder shall include same :- (aa) The work pertaining to wpc shutter shall be executed by the contractor as per MOU from authorised applicator through manufacturer of the materials like WPC shutter, SS screw etc after approval by the GE. (ab) The contractor shall upload with the documents under cover-I \\"Memorandum of understanding\\"(MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be liable to be rejected. |
| 33 | S & F aluminium alloy, anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolt and sliding bolt of extruded section length of bolt of 300mm complete all as specified and directed |
| 34 | S & F aluminium anodized barrel tower bolt of extruded section and fixed of size 150mm complete all as specified and directed |
| 35 | S&F extruded aluminium alloys handles fabricated type anodized of size 150mm long complete all as specified and directed |
| 36 | Supply and fixing curtain rails 25mm of mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 37 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and directed |
| 38 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed |
| 39 | S&F 4.00mm thick sheet glass, selected ordinary quality and glazing with rubber beading or with glazing clips complete all as specified and directed |
| 40 | S & F framed work such as grills, gratings, etc.. with ends of bars, shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed |
| 41 | S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 42 | M & L for 16 to 18 mm thick machine cut green marbel stone as in floor, steps (in single piece), cooking platform, cills of window etc laid over 15 mm thick cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including cement mortar (1:4) complete all as specified and as directed. |
| 43 | M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM (1:6) complete all as specified and directed |
| 44 | S&F Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM (1:6) complete all as specified and directed |
| 45 | M&L cement concrete 25mm thick 1:2:4 type B0 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 46 | M&L for cement concrete 75mm thick 1:4:8 type D2 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 47 | M & L for Glazed ceramic coloured walls tiles in vertical surfaces 300x450x 6mm to 7 mm thick set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles complete all as specified and directed |
| 48 | M & L for 75mm thick PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long complete all as specified and directed |
| 49 | M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 50 | M&L for rendering 5mm thick cement mortar (1:3) on concrete surface even and smooth with & including waterproofing complete all as specified and directed |
| 51 | M & L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying atactic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimum 3.50 Kg/Sqm 3 mm thick (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps complete all as specified and directed |
| 52 | S & F Vitreous China wash down water closet pan (pedestal pattern) white includig fixing bolts, soft closing seat cover and flush pipe 'P' and 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed.(Excluding Flushing Cistern & Flush Pipe) complete all as specified and directed |
| 53 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed |
| 54 | S&F PVC Flush Pipe Of 32mm dia complete all as specified and directed. |
| 55 | S&F Toilet Paper Holder complete all as specified and directed. |
| 56 | S & F Aluminium peg set (03 Nos hook) etc complete all as specified and directed. |
| 57 | S&F CI Nahani Traps 75mm Bore complete all as specified and directed. |
| 58 | S&F CI Floor Traps 75mm Bore complete all as specified and directed. |
| 59 | S & F vitreous china Wash hand basin with pedestal white, flat back type of size 550x400mm including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10X7.5X15cm, 32mm dia PVC waste pipe and 32mm bore chromium plated brass waste coupling with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.(excluding tap, waste chain & plug) complete all as specified and directed. |
| 60 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 61 | S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in wall/trenches or in floors complete all as specified and directed |
| 62 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 63 | S&F PVC Bend Suitable For 110 Mm complete all as specified and directed. |
| 64 | S&F PVC Bend Suitable For 75 Mm complete all as specified and directed. |
| 65 | S & F rotational moulded PVC water storage tank 500ltrs capacity conforming to IS-12701(1989) cylindrical vertical type three-layered white coloured with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I including S&F 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) complete all as specified and directed. |
| 66 | S & F stop/Angle valves 15mm bore pipe cast copper alloy chromium plated with crutch or butterfly handle , screwed both ends for iron pipe complete all as specified and directed |
| 67 | S&F brass chromium plated wall mixer for mixing hot and cold water screwed down for iron pipes and fixed complete all as specified and directed |
| 68 | S& F PVC connection 15mm with PTMT nut of length 450 mm long complete all as specified and directed |
| 69 | S&F PVC valveless syphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets,flush pipe. 10 ltr capacity complete all as specified and directed |
| 70 | S&F 15 mm Fancy type Bib taps long body cast copper alloy chromium plated with crutch or butterfly handle, screwed down complete all as specified and directed |
| 71 | S & F pillar tap cast copper alloy chromium plated, screwed down high pressure with or without lettered \\"Hot\\" or 'cold' with long screwed shanks & flynuts complete all as specified and directed |
| 72 | S & F Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed |
| 73 | S&F Tube 'medium grade' galavanised, with all fitting and fixed complete to walls and ceiling etc 20mm bore complete all as specified and directed |
| 74 | S&F Tube 'medium grade' galavanised, with all fitting and fixed complete to walls and ceiling etc 15mm bore complete all as specified and directed |
| 75 | S&F gun metal gate valve 20mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 76 | S&F gun metal gate valve 15mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 77 | S&F brass chromium tubular towel rail, 20mm dia, D type, 60cm long complete all as specified and directed |
| 78 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed |
| 79 | S&F Soap dish, vitreous China white, approximate size 160x 160x90mm fixed with chromium plated screws complete all as specified and directed |
| 80 | S & F sink with drainage board size 1145x510 mm, bowl size 560x410x200 mm made of stainless steel sheet 1.00mm thick with plugs, washers and wastes pipe & coupling etc incl bedding in cement mortar to draft wall or cantilever brackets and connection union to pipe complete all as specified and directed |
| 81 | Removing excavation material exc. 50m and n exc 250m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 82 | M & L cement concrete 75 mm thick 1:3:6 type C-2 using 40 mm graded stone aggregate complete all as specified and directed |
| 83 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 84 | M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 85 | S&F 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed |
| 86 | M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 for 150 mm bore pipe complete all as specified and directed. |
| 87 | S & F CI Hubless Pipes 100 mm bore single socketed in any length in trenches or in floors complete all as specified and directed |
| 88 | M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 for 100mm bore pipe complete all as specified and directed. |
| 89 | M & L for precast cement concrete type B-1 (1:2:4) (20mm graded stone aggregate) set in CM (1:4) as in landings, covers of manholes etc, shelves and similar articles with plain face including use and waste of formwork complete all as specified and directed. |
| 90 | M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 91 | M & L PCC type C-2, 1:3:6(40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed |
| 92 | M & L for PCC type B-2 , 1:2:4 using 20 mm graded aggregates in surface channels and drains complete all as specified and directed |
| 93 | M & L for 15 mm thick rendering in CM 1:4 on brick or concrete surfaces and finished even and smooth without using extra cement, including providing and making necessary arrengments for scaffolding complete all as specified and directed |
| 94 | On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete for 25 user conventional type complete all as specified and directed |
| 95 | Soakage well 2.4 M dia X 4.5 M effective depth of excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete, Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats around complete all as specified and directed. |
| 96 | M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed. One light/fan point controlled by one switch |
| 97 | One socket outlet point 5 Amp on an independent board complete all as specified and directed |
| 98 | Same as item no 97 but on the same board complete all as specified and directed |
| 99 | Call bell / buzzer point controlled by one bell push complete all as specified and directed |
| 100 | All as item No 96 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board complete all as specified and directed. |
| 101 | S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as specified and directed |
| 102 | Ditto as item 101 but using 15 Amps complete all as specified and directed |
| 103 | S&F socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and directed |
| 104 | S&F socket outlet flush type 5 pin 5 Amps 240 volts complete all as specified and directed |
| 105 | S&F ceiling rose surface bakelite three terminal complete all as specified and directed |
| 106 | S&F bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and directed |
| 107 | S&F angle type holder insulated body with back plate suitable for batten fittings complete all as specified and directed |
| 108 | S&F call bell AC single pole 240 volt Musical Type complete all as specified and directed |
| 109 | Supply & fix fan regulator electronic step type for ceiling fan fixed, in existing board and connecting as directed, after dismantling and removing unserviceable regulator complete all as specified and directed. |
| 110 | S&F sheet metal enclosure (MCB DB) single phase and neutral with 100/125 Amps rated bus bar 8 way double door type , 240 volts complete all as specified and directed |
| 111 | S&F of MCB SP 240 volts, C Curve of 06 to 32 Amps, 10 KA Current carraying capacity complete all as specified and directed |
| 112 | S&F of MCB SPN 240 volts, C Curve of 32 Amps, 10 KA Current carraying capacity complete all as specified and directed |
| 113 | S&F 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and directed Please Enable Macros to View BoQ information |
| 114 | S&F 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and directed Please Enable Macros to View BoQ information |