|
| 1 | Notes : (i) The work consists of 01 job as under:- JOB (A) : 07/LBW/STN HQ/A'BAD/2023-24/Q3 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A' |
| 2 | M&L for Site Clearance of soft / loose soil, watering and removing surplus soil to a distance n exc 50m and making good surface, leveling the area & cleaning etc complete all as directed |
| 3 | Surface excavation n.exe (not exceeding) 30cm deep & averaging 15cm deep & getting out in hard /dense soil complete all as directed |
| 4 | Removing excavation material exe. 250m but n exc. 500m & deposited where directed at a level n exc. 1.5m above the starting point complete all as directed |
| 5 | M&l for hardcore of guage n. exc63mm, deposited, spread & leveled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as directed |
| 6 | M & L 75mm thick plain cement concrete type D-2 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 7 | M&L Providing precast ce ment concrete type -B-1 1 :2 :4 in win- dow or door cills, lintels,kerb stone bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to matchin CM 1:4. all as specified and directed |
| 8 | Sand filling under floors or in foundations including watering and consolidation all as specified. |
| 9 | M& L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as directed |
| 10 | Excavation in post hole for similar holes each nexc 0.50Cum getting out returning filling in and ramming earth around in layers nexc 25 cm watering and removed surplus soil to a distance nexc 50m and making good surface in soft/loose soil. |
| 11 | S&F MS work as in fencing post, blausters etc, angle iron, flat iron, flat iron round or square bars including all necessary cutting, drilling holes in flat iron, bolting etc for screwing chain link fencing all as directed. |
| 12 | M& L Cement concrete 1:3:6 Type C 2 (using 40 mm graded aggregate ,in foundations, filling and mass concrete complete all as specified and directed. |
| 13 | S&F screw bolts (machine made) with hexagonal or square head at one head and rounded the other or screwed both end each screwed end to be fitted with washers and one hexagonal or square nut exc 10cm nexc 15cm long dia of shank 11 to 15mm. |
| 14 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. complete all as specified and directed. |
| 15 | Supply only chainlink fencing any size any type etc complete all as specified and directed. |
| 16 | Supply only mild steel round bars of 10 mm dia as in line wire cut lengths, Hooking ends etc conforming to Fe- 410 - W (Gde E-250) quality A (For tying chain link fencing complete all as specified and directed |
| 17 | M&L for preparation of new untreated steel and iron surfaces of any description, exc 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide complete all as directed |
| 18 | M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide complete all as directed |
| 19 | Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5m depth for foundation etc and getting out in soft/loose soil. |
| 20 | Returning filling in incl. spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil. |
| 21 | Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point. |
| 22 | M&L for cement concrete 1:4:8 type C2 using 40 mm graded agg. as in foundation of manhole all as specified and directed. |
| 23 | M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with old size bricks. |
| 24 | M&L for PCC 1:3:6 type B 1 using 20 mm graded agg as in copping incl. necessary form work & finishing exposed surface of concrete complete all as specified and shown in drawing |
| 25 | M&L for PCC 1:2:4 type B2 using 40 mm graded stone aggregate as in surface channels, benching for manholes all as specified. |
| 26 | M&L for Precast cement concrte type B1 1:2:4 using 20mm graded stone agg set in CM (1:6) in cover slabs for manhole and similar articles etc. complete all as directed |
| 27 | M&L for MS TMT bars 8 mm dia, cut to length, bend to shape required including cranking, bending and binding with MS wire not less than 0.90 mm dia or securing with clips. |
| 28 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 on walls, finished even & fair w/o using extra cement. |
| 29 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls, finished even & fair w/o using extra cement. |
| 30 | Extra for forming fair finished drains or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds materials/stoppage and complete all as specified |
| 31 | M&L for salt glazed stone ware 150 mm internal dia drain pipes grade `A’ laid in trenches and jointed complete all as directed |
| 32 | M&L for concrete cement 1:3:6 type C-2 to drain pipes including packing under and haunching agaainst the sides of the pipes after they are laid and tested for 150mm internal dia of pipe complete all as directed |
| 33 | Cutting into exisiting manhole for connecting new drains, making good to pipe rendering, cutting out exisitng benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required. |
| 34 | Earth Work In Excavation By Mechanical Means (hydraulic Excavator) Means Over Areas (exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5m, As Directed (all Kinds Of Soil) complete all as directed |
| 35 | Earth Work In Excavation By Mechanical Means (hydraulic Excavator) Means Over Areas (exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5m, As Directed (all Kinds Of Soil) complete all as directed |
| 36 | Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (area Of The Sub Structure In Contact With Backfill To Be Measured) complete all as directed |
| 37 | M & L for Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Complete . |
| 38 | M & L for Treating The Soil Along With External Perimeter Of Building At The Rate Of 2.25 Litre Of Emulsion Per Metre Of The Perimeter Wall complete all as directed |
| 39 | M & L for Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area complete all as directed |
| 40 | M & L for Pcc (1:4:8) Type D2(40 Mm Graded Aggregate) For Footing & plinth beam complete all as directed . |
| 41 | Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm In Soft To Loose Soil. |
| 42 | Removing Excavated Soil Not Exc. 50m And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point complete all as directed |
| 43 | M & L Rcc- M-25 (design Mix) Using 20mm Graded Aggregatefor Foundation ,including Rafts & Plinth Beam As Mass Concrete complete all as directed |
| 44 | M & L for Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Foundation & plinth beam complete all as directed |
| 45 | S & F TMT Bars 10mm Dia & Over Of Grade Fe 500d Incl Cutting, Bending, Binding & Placing In Position With Binding Wire complete all as directed . |
| 46 | Ditto But 5 To 10mm Dia In Stirrups, Spacers & Binders complete all as directed |
| 47 | M & L for Rcc- M-25 (design Mix) Using 20mm Graded Aggregate For Column complete all as directed . |
| 48 | M&L for Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Column complete all as directed |
| 49 | M &L for Brickwork With Fly Ash Bricks, Straight Or Curved On Plan Exc 6m Mean Radius, Built In Cm (1:6) complete all as directed |
| 50 | M&L for Brickwork With Flyash Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls, Built In Cm (1:4) complete all as directed . |
| 51 | M & L for Rcc- M-25(design Mix) Using 20mm Graded Aggregate For Chajja complete all as directed |
| 52 | M& L Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Chajja complete all as directed |
| 53 | M & L for Rcc- M-25(design Mix) Using 20mm Graded Aggregate For Slab Beam &Lintel Band complete all as directed . |
| 54 | M&L for Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Slab Beam complete all as directed . |
| 55 | M & L for Rcc- M-25(design Mix) Using 20mm Graded Aggregate For Slab/Landing Slab complete all as directed |
| 56 | M & L for Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Slab/Landing Slab complete all as directed |
| 57 | M & L Rcc- M-25(design Mix) Using 20mm Graded Aggregate For Parapet complete all as directed |
| 58 | M&L for Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Parapet complete all as directed |
| 59 | M & L for RCC- M-25(design Mix) Using 20mm Graded Aggregate For Staircase Excluding Landing complete all as directed |
| 60 | M&L for Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Staircase Excluding Landing complete all as directed |
| 61 | M & L 5 Mm Thick 1:3 Cm Plaster On Ceiling. Finished Even And Smooth (without Using Extra Lime Or Cement) complete all as specified and as directed |
| 62 | M & L 15 Mm Thick (10 Mm + 5 Mm 1:6 Cm) External Plaster On Fair Faces Of Walls Finished Even And Smooth (without Using Extra Lime Or Cement) complete all as specified and as directed |
| 63 | Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed |
| 64 | M&L Pcc 1:3:6 Type C-0 Filling In P.s. Door Frame complete as specified and as directed. |
| 65 | M&L pressed steel frames of size 105x60 mm for door with one or more rebates incl necessary fittings, lugs, hinges, lock strike plate, flat iron hold fast etc complete as specified & as directed. |
| 66 | S & F For 35mm Thickness Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides complete all as directed |
| 67 | S&F 12 Mm Thk Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as directed |
| 68 | S & F Solid Pvc Door Frame Of Size 50mm X 47mm Made Out Of 5mm Plain Colour Pvc Sheet Reinforced With M.s. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing |
| 69 | S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (style) Consisting Of Frame Made Out Of M.s. Tubes For Top & Bottom Rails. M.s. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘c’ Channel Having A Pvc Sheet Strip Of 20mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.s. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing. |
| 70 | S&F for 200 mm long Aluminium anodised barrel tower bolts complete all as directed |
| 71 | S&F for 125 mm Aluminium anodised Al Handles complete all as directed |
| 72 | S&F for 150 mm long Aluminium anodised Drop Bolt complete all as directed |
| 73 | S&F for 150 mm long Aluminium anodised Floor Door Stoper complete all as directed |
| 74 | S&F for 100 mm long MS Butt Hinges complete all as directed |
| 75 | Ms Work Such As Bands, Straps, Hold Fast, Clamps, Hooks & Similar Fe-410-o Or Fe-310-o complete all as directed |
| 76 | S&F Powder Coated Aluminium (minimum Thickness Of Powder Coating 50 Micron) Work For Doors, Windows, Ventilators And Partitions (fixed Portions) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.e. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.p. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-in-charge. |
| 77 | S&F 4 Mm Thick Plain Sheet Glass N Exc 0.5 Sqm In Each Pane complete all as directed |
| 78 | S&F 4 Mm Thick frosted Sheet Glass N Exc 0.5 Sqm In Each Pane complete all as directed |
| 79 | S&F for Wire netting of size 12mm of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples complete all as directed |
| 80 | M&L Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And/or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.gde-e-165 complete all as directed |
| 81 | M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distamper over a coat of 1 to 2mm (1.5mm average) thick wall care putty and one coat of alkali resistant primer complete all as directed |
| 82 | M&L for preparation of new plastered surface and apply three Coats of white wash over ceiling complete all as directed |
| 83 | M&L for preparation new plastered surfaces of external wall and applying two coats cement base paint over a coat of alkali resistant primer complete all as directed |
| 84 | M&L Preparing new or previously untreated wood & wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of pink primer complete all as directed |
| 85 | M&L machine cut Kota stone slab 20-25 mm thick as in flooring or trades of step incl half round moulding over and including screed bed 20 mm thick in CM (1:3) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as directed |
| 86 | M&L Virified Ceramic Tiles 10 Mm Thick (square/ Rectangular) Polished, Area Of Each Tiles n. Exceeding 0.36 Sqm In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match incl 10mm thick screed bed CM 1:6 all as Specified. |
| 87 | M&L for Cement concrete 25mm thick 1:2:4 type B1(20mm graded aggregate) as in sub base complete all as directed |
| 88 | S&F Non - Skid Ceramic Tiles 7 To 8 Mm Thick (square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match incl and over screed bed or beeding layers of mortar 10mm thick in CM 1:6 in floors, complete all as specified and directed. complete all as specified and directed. |
| 89 | S&F Glazed Ceramic Tiles In Vertical Surface 350x 250x 7 Mm/ 450x 350x 7mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match incl and over screed bed or beeding layers of mortar 10mm thick in CM 1:3 in floors, complete all as specified and directed. complete all as specified and directed. |
| 90 | M & L 75mm Thick Plinth Protection Pcc (1:3:6) Using 20mm Graded Aggregate (0.90m Wide). |
| 91 | M&L APP Based Polymeric Membrane Minimum Weighing 3kg/sqm And Minimum 3mm Thick Reinforced With Polyster Non Wove Fabric (wt. Not Less Than 150 Gms/sqm) Laid On Primed Surface By Torched Application Complete And Finally Finished As Per Manufacturers Instructions incl Screed Bed Or Bedding Layer Of Mortar Cm(1:4) 10mm Thick For Laying Floor Finishes As In Base |
| 92 | S& F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified |
| 93 | S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length complete all as specified and directed. |
| 94 | S&F health faucet with one meter tube and hook complete all as specified and directed |
| 95 | S&F PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumised hanging device complete all as directed. |
| 96 | S&F CP toilet paper holder complete all as specified and directed |
| 97 | S&F C I Nahani Traps 75mm Bore complete all as directed |
| 98 | S&F C I Floor Traps 75mm Bore complete all as directed |
| 99 | S&F vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste , chain & plug & porcelain stopper including brackets incl cutting for pinning in ends of bracketes or erecting stand and fixing and supply and waste pipe complete all as specified and directed |
| 100 | S&F Pillar Tap Fancy Type Chromium Plated Long Shank Aluminium Anodised complete all as directed |
| 101 | S&F Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle Chromium Plated complete all as directed |
| 102 | S&F Tubular Towel Rail, 20mm Dia, D Type, 60cm Long Between Flanges complete all as directed |
| 103 | S&F 600mm x 450 mm bevelled edge mirror of selected quality, mounted on 6 mm thick AC plain building board or commercial plywood and fixed to wall on wooden plugs with chromium plated brass screws and cup washers all complete as specified and as directed. |
| 104 | S&F Pvc Swr Pipe 110 Mm Soil Pipe complete all as directed |
| 105 | S&F Pvc Swr Pipe 75 Mm Waste Pipe complete all as directed |
| 106 | S&F Pvc Bend Suitable For 110 Mm complete all as directed |
| 107 | S&F Pvc Bend Suitable For 75 mm complete all as directed |
| 108 | S&f Sinks With Drainage Board Made Of Stainless Steel Lmm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915mm X 460mm Bowl Size 410mm X 330mm X160mm complete all as directed |
| 109 | S & F 1000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed |
| 110 | S&F 25 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut. |
| 111 | Supplying and laying of 20 mm bore CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches, fixing on walls/ceiling or laying in floors complete all as specified |
| 112 | Supplying and laying of 25 mm bore CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches ,laid concealed in floor or wall including all fittings suitable for fixing of plumbing fixture complete all as specified |
| 113 | M&L for point wiring with 1100 volts grade PVC insulated FR-LS multistranded copper conductor cable 1.5 sqmm (Phase - R Y B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed modular steel terminal boxes of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover for mounting modular switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following |
| 114 | (a) One light point controlled by one switch. |
| 115 | (b) One ceiling/ex fan point controlled by one switch. |
| 116 | (c) One socket outlet 6 amp controlled by one switch on the same board with other switches. |
| 117 | (d) One socket outlet 6 amp controlled by one switch on indepdendent board. |
| 118 | (e) One bell point controlled by one bell push. |
| 119 | (c) One light point controlled by two, two way switches. |
| 120 | M&L for Point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with suitable and required size of modular box for one 16 amp socket outlet controlled by one switch on independent board complete all as directed |
| 121 | S&F modular switch one way 6 amp 1 module all as specified and directed |
| 122 | S&F modular switch one way 16 amp 1 module all as specified and directed |
| 123 | S&F modular socket 6/16 - 2/3 pin combined 2 module all as specified and directed |
| 124 | S&F modular socket 6 amp 2/3 pin combined 2 module all as specified and directed |
| 125 | S&F Ceiling rose 6 amp, 3 plates polycarbonate body complete all as directed |
| 126 | S&F modular switch two way 6 amp 1 module complete all as directed |
| 127 | S&F modular bell push, 6 amp, 1 module complete all as directed |
| 128 | S&F bell multi music type, AC, 240 volts complete all as directed |
| 129 | S&F modular hum free electronic step fan regulator, 100 watt 2 module all as specified and directed |
| 130 | Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed. |
| 131 | S&F LED batten (1.2 m) made of Aluminium housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as directed |
| 132 | S&F MCB distribution board ETPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. |
| 133 | S&F LED fixture 8 watt including connection complete all as directed |
| 134 | S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. |
| 135 | S&F LED 20W streetlight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP65 protection complete with fixing arrangement and connections as directed |
| 136 | S&F air ventilation fan 250 mm in toilet in rectangular in shape, PVC body, white colour 230V including louber shutter complete all as specified and directed. |
| 137 | Supplying and fixing smart single phase four wire energy meter BIS 16444:2015 (Reaffirmed 2020) marked in existing meter board/floor panels having current range 10-60 Amp,415 Volts,accuracy class 1.0 complete all as directed |
| 138 | M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:- |
| 139 | (a) 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20 mm dia conduit.. |
| 140 | (b) 2x4 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit.. |
| 141 | M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-5 of SSR Part-I. all specified |
| 142 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as directed |
| 143 | S&F wall mounted fan with powder coated guards and blades of approved colour, AC single phase, 230 volts, 50Hz, 1440 rpm, 400mm sweep with adjustable verticle angles & three speed controls mounted within reach of hands with necessary connecting cables recommended/ provided by manufacturer complete all as directed |
| 144 | S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- |
| 145 | (a) Single pole 6 to 32 amp. |
| 146 | (b) Double pole 32 amp. |
| 147 | S&F ceiling fans complete with blades, down rods and accessories, 230V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 148 | Supply and laying DWC(Double wall corrugated) HDPE pipe,ISI marked,IS 16205(part 24):2017 part 2 of outer dia 50 mm and inner dia 38 mmwith smooth internal and profiled external surface for non pressure underground cable including all connected acceseries like coupler,o-ring etc complete all as specified and directed Make : Rex Polyextrusion/Gemini/Astral |
| 149 | Supply & Laying ,XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25sq. mmX 4Core complete all as directed |
| 150 | Cutting existing steel tubing for alterations or aditions of pipe size 40/50 mm bore and screwing complete all as directed |
| 151 | Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (3/4”) dia complete all as directed |
| 152 | Supply and fix Valve, globe conforming to IS 9338, 50mm (2”) dia pipe complete all as directed |
| 153 | S&F 25 mm dia , Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated complete all as directed Please Enable Macros to View BoQ information |