|
| 1 | TOILET BLOCK - ITC NIL |
| 2 | INDIAN WC WITH PVC CISTERN |
| 3 | EXC. IN ALL KINDS OF SOIL |
| 4 | EXC.EXTRA LIFT EVERY 1.5M ALL KIND SOIL |
| 5 | SUPPLY FILLING LOCAL SAND ZONE IV |
| 6 | 1 CEMENT:3 COARSE SAND:6 AGG. 20MM |
| 7 | CENT.& SHUT.FOR PCC-FOUND,FOOTING ETC |
| 8 | RCC 1:1½:3 UP TO PLINTH LEVEL W/O C&S |
| 9 | RCC 1:1½:3 WALLS ..UPTO 5 LVL W/O C&S |
| 10 | CENT.& SHUTT. FOR RCC SLABS, ROOFS |
| 11 | CENT.& SHUTT. FOR RCCLINTELS, BEAMS |
| 12 | TMT BARS FE- 500 GRADE |
| 13 | BRICK WORK IN CM 1:4 IN FOUNDN & PLINTH |
| 14 | MS GRILLS TO WINDOWS |
| 15 | POWDER COATED AL.SECN,FIXED GLAZING |
| 16 | POWDER COATED AL.SECN, SHUTTERS |
| 17 | FLOAT GLASS 6.0MM IN AL.SEC. |
| 18 | FLOAT GLASS 8.0MM IN AL.SEC. |
| 19 | P/FIXING 12MM FRAMELESS TOUGHENED GLASS |
| 20 | ROLLING SHUTTERS |
| 21 | CHEQUERRED PRECAST CC TILES IN FOOTPATH |
| 22 | CERAMIC GLAZED TILES FOR WALLS |
| 23 | CERAMIC GLAZED TILES FOR FLOORING |
| 24 | 60X60 CM VITRIFIED FLOOR TILES |
| 25 | 75MM PVC RAIN WATER PIPE |
| 26 | 12MM CEMENT PLASTER,1:4 WITH FINE SAND |
| 27 | 6MM CEMENT PLASTER WITH FINE SAND |
| 28 | NEAT CEMENT PUNNING |
| 29 | 2MM THK POP PUNNING OVER PLASTER |
| 30 | WASHABLE OIL BOUND DISTEMPER |
| 31 | ONE COAT OF CEMENT PRIMER ON WALL |
| 32 | ACRYLIC SMOOTH EXTERIOR PAINT |
| 33 | SYNTHETIC ENAMEL PAINT |
| 34 | EUROPN WC,VIT.CHINA CISTERN WHITE LID |
| 35 | WASH BASIN 550X400,SINGLE CP BRASS TAPS |
| 36 | 600X450 BEVELLED EDGE MIRROR |
| 37 | 100X100MM SCI S&S TRAPS IS 3989 |
| 38 | CPVC PIPES 15MM CONCEALED |
| 39 | CPVC PIPES 20MM CONCEALED |
| 40 | 15MM BRASS BIB COCK |
| 41 | 15MM BRASS STOP COCK |
| 42 | LIGHT/FAN/5A POINT, WIRING, MOD SWITCH |
| 43 | LIGHT/POWER PLUG, WIRING, MOD SWITCH |
| 44 | SUBMN WIRE-2X2.5SQMM,EARTHWIRE1X2.5SQMM |
| 45 | SUBMN WIRE-2X4SQMM,EARTHWIRE 1X4SQMM |
| 46 | S&F 15AMP MODULAR TYPE 6 PIN SOCKET |
| 47 | S&F SWITCH WITH 4 MODULE FRAME |
| 48 | S&F SWITCH WITH 6 MODULE FRAME |
| 49 | S&F SWITCH WITH 12 MODULE FRAME |
| 50 | S&F FAN REGULATOR OF STEPPED MODULAR |
| 51 | S&F 100AMP TPN SWITCH FUSE UNIT |
| 52 | S&F 6A TO 32A DP MCB |
| 53 | LED TUBE LIGHT: 18W WITH IP65 PROTECTION |
| 54 | LED TUBE LIGHT: 8W WITH IP20 PROTECTION |
| 55 | S&I 1200 MM SWEEP CEILING |
| 56 | CIVIL WORK - ITC NIL |
| 57 | HOARDING LIGHTS:30W WITH IP65 PROTECTION |
| 58 | S&F MCB+ELCB UPTO 32A DP MCB |
| 59 | S&F MCB+ELCB UPTO 32A SP MCB |
| 60 | CABLE TERM,NON FLP DC GLAND 3X2.5SQMM |
| 61 | S&L 3X2.5 SQMM,1.1KV FRLS CU ARMD CABLE |
| 62 | FOUND.BOLT 25MMDIAX1.0M L,100X8MM PLATE |
| 63 | P/F ALUMINIUM 700MM WIDE GUTTER |
| 64 | FACTORY MADE KERB STONES |
| 65 | DRY STONE PITCHING |
| 66 | GRANULAR SUB BASE -53MM TO 0.75MM |
| 67 | SYNTHETIC ENAMEL PAINT |
| 68 | WATER PROOFING CEMENT PAINT |
| 69 | 12MM CEMENT PLASTER1:4 WITH COARSE SAND |
| 70 | 12MM CEMENT PLASTER,1:4 WITH FINE SAND |
| 71 | HOT FINISHED WELDED TYPE TUBULAR TRUSS |
| 72 | BRICK ON EDGE FLOORING IN CM 1:4 |
| 73 | HALFBRICK MAS.IN CM 1:4 FOUND & PLINTH |
| 74 | CENT.& SHUTT. FOR RCC SLABS, ROOFS |
| 75 | RCC 1:1½:3 WALLS ..UPTO 5 LVL W/O C&S |
| 76 | PRE-CAST CC 1:2:4 KERB STONE,..WITH C&S |
| 77 | CENT.& SHUT.FOR PCC-FOUND,FOOTING ETC |
| 78 | 1 CEMENT:4 COARSE SAND:8 AGG. 40MM |
| 79 | 1 CEMENT:3 COARSE SAND:6 AGG. 20MM |
| 80 | 1 CEMENT:2 COARSE SAND:4 AGG. 40MM |
| 81 | 1 CEMENT:2 COARSE SAND:4 AGG. 20MM |
| 82 | 1 CEMENT:1½ COARSE SAND:3 AGG. 20MM |
| 83 | SUPPLY FILLING LOCAL SAND ZONE IV |
| 84 | SUPPLY AND FILLING IMPORTED EARTH |
| 85 | EXC.EXTRA LIFT EVERY 1.5M ALL KIND SOIL |
| 86 | CLEARING JUNGLE,UPROOTING GRASS,TREES |
| 87 | EXC. OVER AREAS IN ALL KINDS OF SOIL |
| 88 | vii) 40MM DIA HDPE PIPE UPTO 65M DEEP |
| 89 | 75X75X75X75MM DBLE EQ. JUNC WITH A.DOOR |
| 90 | 75MM DIA SCI S&S PLAIN BEND IS 3989 |
| 91 | 80 MM M40 PAVER BLOCKS |
| 92 | WET MIX MACADAM |
| 93 | EXTRA FOR COMPACTION-95% OF DRY DENSITY |
| 94 | GRANULAR SUB BASE -75MM TO 0.75MM |
| 95 | 150F/200F FALSE CEILING |
| 96 | 160MM PVC RAIN WATER PIPE |
| 97 | KLIPPON GALVALUME PLAIN SHEET FLASHING |
| 98 | KLIPPON GALVALUME PLAIN SHEET RIDGES |
| 99 | KLIPPON GALVALUME SHEET ROOFING |
| 100 | STR.STEEL IN BUILT UP SECTION |
| 101 | TMT BARS FE- 500 GRADE |
| 102 | CENT.& SHUTT. FOR RCC FOUNDN,FOOTING |
| 103 | RCC 1:1½:3 UP TO PLINTH LEVEL W/O C&S |
| 104 | LINEAR RECESSED MOUNTED LED |
| 105 | NON-CAPEX ITEM - ITC FUL |
| 106 | Arrangement of Electrical Power Connecti Please Enable Macros to View BoQ information |