| 1 | Taluk Hospital |
| 2 | 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below |
| 3 | 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 4 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 5 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 7 | 13.98.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work |
| 8 | 50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 9 | 50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood |
| 10 | 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 11 | 13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 12 | OD486973/2025-2026:(Derived from DAR 50.10.2 & 13.52.1) Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and Finishing with Epoxy paint (two or more coats) over a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete as per the direction of the Engineer in charge |
| 13 | OD487187/2025-2026:DSR Roofing with G.I. Hard colour powder coated trafford sheets of 0.35mm thick or nearest size of available thickness , with the overlap of 150mm at end GI hook or crank, C.I bolt and nuts including plain washers and bitume washers etc.. complete as per the direction of the officer in charge |
| 14 | OD486977/2025-2026:supplying and fixing 150 mm pvc gutter including cost of conveyance labor as per direction from departmental officers |
| 15 | OD487044/2025-2026:DSR Sheet Providing and fixing pre coated galvanized iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.30 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desirably Engineer-in-charge. The sheet shall be fixed using self rilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 16 | OD495055/2025-2026:Engaging man coolie for cleaning, removal of waste etc.. complete as per the direction of the Engineer incharge |
| 17 | OD525789/2025-2026:providing and laying 20 mm aggregate in yard 50 mm thick including spreading, dressing etc... complete as per trhe direction of the officer in charge. |
| 18 | OD510375/2025-2026:Engaging carpenter for maintenance work |
| 19 | OD525737/2025-2026:Derived from 10.25.2 & 13.52.1 Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74, Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and finishing with epoxy paint (two or more coats) over a priming coat of approved steel primer using structural steel, hollow tubes etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works etc complete as per the direction of the officer in charge. |
| 20 | 50.9.11.2:Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. Please Enable Macros to View BoQ information |