Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel-300mm dia 8mtr length |
| 3 | Earth work in excavation by manual / mechanical means in foundation trenches or drains, including dressing of sides and ramming of bottoms and dewatering wherever required, including all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km including cost of all labours/ equipments , taxes, sundries and T&P etc all complete as per the direction of Engineer-in-charge.All kinds of soil |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering etc. including all lead and lift, cost of labour ,material, conveyance and taxes ,sundries ,T & P, complete as per the directions of Engineer-in-charge. |
| 5 | Disposal of building rubbish/ malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping site or as approved /directed by Engineer-in-charge, including all lead and lifts involved, labour, etc. including all taxes as per the direction of Engineer-in-charge. |
| 6 | SAND FILLING :- Filling in foundation, trenches and plinth with river sand, well watered and compacted in layers of with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all and royalties, loading and unloading, including cost of all labour, sundries ,T & P etc. complete as per directions of the Engineer -in-charge. |
| 7 | P.C.C (1:3:6) :- Providing and laying of Cement Concrete of grade 1: 3 :6 (1 cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal ), mixing in concrete mixer ,lowering and compacting in proper thickness, watering & curing for the required period. including all cost of labour ,material, conveyance, royalties and , sundries ,T & P etc. complete as per the directions of Engineer-in-charge. |
| 8 | Providing and laying of Cement Concrete of grade 1: 4 :8 (1 cement : 4 sand : 8 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal ), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc. complete as per the directions of Engineer-in-charge. |
| 9 | Antitermite treatment Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as pre-constructional anti- termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313 /1981(Part-II) complete including cost, conveyance , loading, unloading of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. complete in all respect as directed by the Engineer-in-charge. |
| 10 | Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all type of Concrete works as per IS Specification, including cost of required steel centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but excluding cost of Reinforcement and Binding wires etc. Pile cap/footing |
| 11 | plinth Beam |
| 12 | Ground floor-column |
| 13 | first floor column |
| 14 | RCC Wall |
| 15 | Ground floor Roof beam |
| 16 | First floor Roof beam |
| 17 | FLAT SLAB |
| 18 | Slope roof |
| 19 | Double stage centering and shuttering of slab |
| 20 | STAIRCASE |
| 21 | Lintel-Ground floor |
| 22 | REINFORCEMENT :- Providing & fixing Thermo mechanically treated bars (Fe-500 D) Reinforcement bars of approved make for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyance of reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour, loading, unloading, labour cess, T&P, etc. required for the work complete for the work in all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement) GRound floor |
| 23 | First floor |
| 24 | Flyash Brick Masonry in cement mortar of mix (1:6) using Flyash bricks of size 25 c.m x 12 c.m x 8 c.m having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the Flyash bricks for 6 (Six) hours in water before use in works such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, stacking, loading, unloading, royalties and of all materials,cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.FOUNDATION & PLINTH |
| 25 | Super structure Upto height4.2 mtr |
| 26 | Above 4.2 mtr |
| 27 | Flyash Brick Masonry for 125 mm width brick masonry wall in cement mortar of mix (1:4) using Flyash bricks of size 25 c.m x 12 c.m x 8 c.m having crushing strength not less than 75 kg per square c.m with provision of 2 ( Two nos ) of 8 m.m dia M.S. Round Reinforcement Bars at each 4th layers) with cement and screened & washed sharp river sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, stacking, royalties and of all materials ,cost of all labour, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 28 | Providing 12mm thick cement plaster in cement mortar (1:4) with mixing of water proofing compound to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finisjing the plaster surface smooth using wooden floats ,bars, etc only to proper plumbs and level making grooves, beads and drip courses to give required ornamental finish as per the drawings including cost of all materials, conveyance, loading and unloading ,royalties, cost of all labours ,materials, scaffolding ,watering & curing, sundries, T&P etc. complete as per the direction of Engineer-in-charge . |
| 29 | 12MM THICK CEMENT PLASTER (1:6) :- Providing 12mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) with mixing of water proofing compound etc. including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge.Super structure Upto height4.2 mtr |
| 30 | Above 4.2 mtr |
| 31 | 16MM THICK CEMENT PLASTER (1:6) :- Providing 16mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) with mixing of water proofing compound etc. including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge.Super structure Upto height4.2 mtr |
| 32 | Above 4.2 mtr |
| 33 | 6MM THICK CEMENT PLASTER (1:4) :- Providing 6mm thick cement plaster with cement mortar of (1:4) with mixing of water proofing compound to RCC surface of roof slabs ceilings , stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc all complete as per direction of the Engineer -in-charge.Super structure Upto height4.2 mtr |
| 34 | Above 4.2 mtr |
| 35 | Providing average 40mm thick grading Concrete with (1:2:4) using 12mm & down graded size black hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. |
| 36 | Providing and laying Kota Stone Flooring using Kota tiles of area above 0.10 sqm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.Ground Floor |
| 37 | Providing and laying Kota Stone in Dado/Skirting using kota tiles of area above 0.10 sqm of approved make, quality and colour without any warpage laid over an under layer of 12 mm thick base of cement mortar (1:3) (1 cement: 3 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.Ground Floor |
| 38 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. ( Area of slab over 0.50 sqm) Granite SlabGROUND FLOOR |
| 39 | Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge |
| 40 | Providing & laying machine cut, mirror polished, Italian Marble stone in dado/skirting using 20mm thick granite stone slab of approved quality, colour and size to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) |
| 41 | TOILET WATER PROOFING :- Hs latex shield 2k Waterproofing application: - Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 60% Crack Bridging ability: Up to 1 mmAdhesive strength: 1.0 N/mm² @ 28dTensile elongation: 30% @ 20°CShore A Hardness >85 (between 3 - 7 days)etc. as per direction of E.I.CThe item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation etc. complete as per design, drawing & instructions of EIC.Ground Floor |
| 42 | Providing and fixing Vitrified tile of specified size in floors on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 sand) with neat cement slurry . finishing the joint with epoxy based water proof grout to match the shades of the tiles etc.including cost of all materials,labours & royalties, conveyance ,loading and unloading ,sundries ,T & P etc .complete as per the specification & direction of Engineer-in-charge. Size of tile 600x 600 mm (Full Body Double charge Vitrified tiles) |
| 43 | Providing & laying vitrified tile of specified size in skirting cut from approved make confirming to IS-15622 specifications over 12mm thick cement mortar (1: 3) to proper line and level to a height as per design including cutting to required size and shape, fixing at corners and splays etc. including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles and complete as per the design & drawing with cost of all materials, labour, conveyance T&P etc. All complete as per the direction of Engineer -in-charge. Size of tile 600x 600 mm (Full Body Double charge Vitrified tiles) |
| 44 | Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Ground Floor |
| 45 | Providing & laying granite stone tiles in dado/skirting using 20mm thick granite stone slab of approved quality, colour and size Above 0.10 Sqm & up to 0.4 sqm to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) Ground Floor |
| 46 | Providing and fixing Vitrified tile of specified size in floors on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 sand) with neat cement slurry . finishing the joint with epoxy based water proof grout to match the shades of the tiles etc.including cost of all materials,labours & royalties, conveyance ,loading and unloading ,sundries ,T & P etc .complete as per the specification & direction of Engineer-in-charge. Vitrified tile rustic finish (600x600mm) Ground Floor |
| 47 | Providing and fixing ceramic glazed wall tiles of specified size of thickness 6-10mm conforming to IS: 15622 specifications of approved make and shade, in skirting and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and finishing the joint with epoxy based water proofing grout to match the shade. All complete as per the direction of Engineer-in-chargeSize of Tile 300x600mm Ground Floor |
| 48 | DOUBLE LEAF ALUMINUM OPENABLE GLASS DOOR :- Providing and fixing Anodized System Aluminum double leaf openable glass door made of TOSTEM / NCL ALLURO / ALUMIL make suitable for 1.6 KPA wind load with 50mm visible aluminium section width in the centre interlock. The system offered must be ride-in system with two glass panels moving inside the channel without any external overhung along with a provision for mesh panel on the third track. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Tex guard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacturer. All Slider doors & windows will be centre locking with integrated Anti-lift in slider panel. Only EPDM gaskets should be used in all meeting points instead of Brush Pile. The outer frame Depth will be 72 mm +/- 3 mm The bottom frame must use a subframe and no direct grouting will be permitted on bottom frame directly. All glasses will be 5 mm clear toughened.The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 1600 Pa.GROUND FLOOR |
| 49 | \\"Providing and fixing factory made 46 mm thick Plain steel door RAL Finish of approved size and make made of 0.8/1.0/1.2mm thick GI Sheet for shutter and 1.2/1.6 mm thick GI sheet for frame conforming to IS 277 with minimum 120 gsm of Zn Coatingto provide rust resistance.The Gap between the sheets shall befilled with Honeycomb paper of minimum 150 gsm and providedwith stiffeners for tower bolts and Lock (1 No.) etc. as perapproved drawing. The outer surfaces shall be finished with PurePolyster powder coating (Jotun or Equivalent) of thickness not less than 60 Micron complete as per the directions of Engineer-in-charge. Mortise Latch Lever Lock with handle - SS304 finish(Dorset/Hettich/Kich), Ball Bearing Hinges SS304 4X3X3, Tower Bolt-300mm , Door Stopper D handle and Door Closer as per requirement ( Geze, Dorma, Hettich or Dorset)Ground Floor |
| 50 | Supplying and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with farme ,shutters, and all fitting and fixtures.Ground Floor |
| 51 | WPC DOOR FRAMES :- Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. frame size 50 x 100 mm including carriage of frame Ground Floor |
| 52 | WPC DOOR :- Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water /moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge..30mm thick WPC Door Ground Floor |
| 53 | M.S GRILLS FOR WINDOW :- Supplying, Fitting and Fixing M.S Grills of approved designs made out of M S Flat, Square bars/Round bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading, stacking, of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.Ground Floor |
| 54 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with layering technique Power Spray methodology have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color . The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least, 50% void space. The screens casting shall take place with layering methodology using- Direct Power Spray machines. The screens shall be casted from ‘53 grade’ White Portland Cement , Fine graded, sieved Quartz & Silica Sand, reinforced with Alkali Resistant Glass Fiber manufactured between 4-5% having Zirconia content at least 16%, Super Plasticizers Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation . The material casting should take place in FRP Molds. The GRC Panels flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.P should be above or equivalent to 15 N/mm2 for tests done on 28 days cured samples. The fixing of panels should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners & Self Tapping screws or as per approved shop drawings approved by site engineer in charge. |
| 55 | Supplying, fitting and fixing of stainless steel of 304 grade in hand rail using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mt c/c and stainless square pipe bacing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance,of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- charge. |
| 56 | SYNTHETIC ENAMEL PAINT :- Painting with synthetic enamel paint of approved brand and manufacturer of required colour to give an even finish with two or more coats on new work of wood /steel over a coat of suitable shade with primer of approved brand and manufacturer's instructions including cost of all materials with taxes and transportation, all labour, scaffolding, sundries, T&P etc. All complete as per the direction of the Engineer -in-charge Ground Floor. |
| 57 | PUTTY WORK :- Finishing surface of walls with cement based wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of scaffoding staging charges with cost of all materials,taxes,labour T&P etc complete as per the direction of the Engineer -in-charge.Super structure Upto height4.2 mtr |
| 58 | Above 4.2 mtr |
| 59 | ACRYLIC EMULSION PAINT :- Wall painting with two or more coats of premium acrylic emulsion paint (Two or more coats ) of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour including cost, coveyance, loading and unloading, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge.Super structure Upto height4.2 mtr |
| 60 | Above 4.2 mtr |
| 61 | WEATHER COAT PAINT :- Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat (Two or more coats ) of exterior primer applied @ 0.90 litre/10 sqm Super structure Upto height 4.2 mtr |
| 62 | Above 4.2 mtr |
| 63 | TEXTURED PAINT :- Providing Two coat of Textured paint of approved make, quality and shade over the wall surface of the building over (Two or more coats ) of primer of approved make including cost of material, brushes, all labour, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Super structure Upto height4.2 mtr |
| 64 | Above 4.2 mtr |
| 65 | Providing and fixing of Asphalt based laminated roofing shingles of Technonicol Lousiana or equivalent complying with EN-544 SINGLELAYER, base per layer fiber glass 100 of Flow resistance at elevated temperature 150 degree C, Thickness per layer 2.7 +- 0.2, mm and weigh per sqm12.5 Kg /M square), Over the App membrane shall be laid using nailing and sealing all joints etc . and preparing the Surface complete as per direction of Engineer-in-charge. Providing and fixing of Asphalt based Double gauge high end factory made HIP & RIGDE of Technonicol Lousiana or equivalent complying with EN- 544 SINGLE- LAYER, base per layer fiber glass 110 of Flow resistance at elevated temperature 100 degree , Thickness per 3.4 +- 0.2, mm and weight per sqm 5.5 Kg /M square), Over the App membrane shall be laid using nailing and sealing all joints etc . and preparing the Surface complete as per direction of Engineer-in-charge.Technonicol Lousiana Roofing Shingles |
| 66 | HIP & RIGDE |
| 67 | Providing and fixing Ornamental plaster as per approve design etc. including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 68 | Supply of MCM Modified Clay Material - MCM R Series Brick - 222 x 63 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.Ground Floor |
| 69 | Filling in site with river sand, well watered and compacted in layers of with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all and royalties, loading and unloading, including cost of all labour, sundries ,T & P etc. complete as per directions of the Engineer -in-charge. |
| 70 | Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit.(i) Girth from 300 mm to 600 mm |
| 71 | (ii) Girth from 600 mm to 900 mm |
| 72 | (iii) Girth from 900 mm to 1800 mm |
| 73 | Providing and laying cement concrete 1:2:4 (any thickness), including the cost of centering,shuttering and finishing :including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer -in-charge |
| 74 | Manufacturing, Providing & Installation of GFRC (Glass Fiber Reinforced Concrete), Make Samudyam, with Pattern, design, and colour of approved make to be fixed on/between RCC /Block work Column or structural work with Dry Fixing method with appropriate SS Pipe & Cleats frame work, using fasteners, and necessary hardware etc. The element shall be made from '53 grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre make 'Owens Corning' or equivalent, Super plasticizers / Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROX (Germany)' or equivalent. The material casting shall take place in Synthetic Rubber / FRP Mould manufactured by Mould / Tool / MouldGrade Resin of Revex/ 'Reckli' or equivalent.GFRC JALI (thickness of 25-30 mm & Border thickness of 50) |
| 75 | GFRC BALUSTER (SIZE OF 170*1300) |
| 76 | GFRC RAILING (SIZE OF 80*1000) |
| 77 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with layering technique Power Spray methodology have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color . The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least, 50% void space. The screens casting shall take place with layering methodology using- Direct Power Spray machines. The screens shall be casted from ‘53 grade’ White Portland Cement , Fine graded, sieved Quartz & Silica Sand, reinforced with Alkali Resistant Glass Fiber manufactured between 4-5% having Zirconia content at least 16%, Super Plasticizers Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation . The material casting should take place in FRP Molds. The GRC Panels flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.P should be above or equivalent to 15 N/mm2 for tests done on 28 days cured samples. The fixing of panels should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners & Self Tapping screws or as per approved shop drawings approved by site engineer in charge. |
| 78 | Supplying, Fitting and Fixing MS Gate/similar work of approved designs made out of M S Flat, Square bars/Round bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Massonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Massonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.( Weight to be taken properly prior to fixing the grills in the works and payment to be made accordingly ) |
| 79 | Supplying and fixing of MS structural members of approve designa nd drawing for cow catcher etc. .d .including all cost of labour ,material, conveyance,royalties and ,sundries ,T & P etc. complete as per the directions of Engineer-in-charge. |
| 80 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction construction & Clause 305 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 81 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 82 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 83 | Filling in with river sand, well watered and compacted in layers of with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all and royalties, loading and unloading, including cost of all labour, sundries ,T & P etc. complete as per directions of the Engineer -in-charge. |
| 84 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRC SP63:2018 |
| 85 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRCSP63:2018 |
| 86 | Supplying and fixing of precast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 |
| 87 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 |
| 88 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Covers on drains of footpath of various sizes, of M-25 grade cement concrete, including cost of centering, shuttering, reinforcement of specified dia TMT bars of Fe 500 grade, neat cement punning on finished surface, properly encased on all edges and providing 2 Nos. 12 mm dia bar for hooks, including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 89 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water |
| 90 | Supplying and stacking of good earth at site including royalty and carriage(earth measured in stacks will be reduced by 20% for payment). |
| 91 | Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 92 | Rough dressing the trenched ground including breaking clods. |
| 93 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 94 | Fine dressing of the ground. |
| 95 | Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment).(i)Screened through sieve of I.S designation 20mm |
| 96 | (ii)Screened through sieve of I.S designation 16mm |
| 97 | Spreading of sludge, dump manure and/ or good earth in required thickness as per the direction of the officer-in-charge (cost of sludge, dump manure and /or good earth to be paid separately) |
| 98 | Grassing with selection no.1 grass including watering and maintainance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for moving including supplying good earth,if needed (the grass & good earth shall be paid separately) |
| 99 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge. |
| 100 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep |
| 101 | Holes 45 cm dia, and 45 cm deep |
| 102 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)Trees Plant |
| 103 | Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting.Neem of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 104 | Karanja of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 105 | Akashmalli of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 106 | Amla of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 107 | Mango of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 108 | Kochila of height 4m -5m (2 to 3 years old) well developed with thick stem |
| 109 | Champa (white,red, pink) of height 3m-4m (2 to 3 years old) well developed with thick stem |
| 110 | Baul of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 111 | Ashoka of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 112 | Arjun of height 3m-4m (2 to 3 years old) well developed with thick stem |
| 113 | Coconut Trees |
| 114 | Royal poinciana Gulmohar Delonix regia Krushnachuda Tree |
| 115 | Supplying and planting below mentioned best quality container- grown healthy shrubs/plants of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting.Aparajita (black & height) of height up to 1 mtr (1 to 2 yrs) old |
| 116 | aswagandha of height up to 2 mtr (1 to 2 yrs) old |
| 117 | dhannantari of height up to 2 mtr (1 to 2 yrs old) |
| 118 | Providing and fixing khandolite Stone work, in flooring, of required thickness and size including dressing, packing and grouting with an admixture of pigment matching the stone shade. Including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, T & P etc. All complete as per drawing and direction of the Engineer -in-charge. |
| 119 | Providing and fixing Premoulded joint filler board 12 mm thick in expansion joints all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) |
| 120 | Forming cavity 150 mm wide in RCC walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated as per the approved design and specification .including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 121 | Providing and fixing stainless steel acrylic LED letter (Logo) As per the architectural design and drawing etc all complete as per the direction of Engineer-in-charge. |
| 122 | Removing old cement plaster from walls , including raking out joints 12mm deep and removing the debris away from the site with all lead and lift including cost of the direction of Engineer-in-charge.Ground Floor |
| 123 | Dismantling and removing R.C.C columns, beams, slab, staircase, landing, lintels, corbels. Including stacking the useful materials for reuse and removing the debris away from the site all lead and lift including cost of all labour etc. complete in all respect as per direction of Engineer-in-charge.Ground Floor |
| 124 | Removing white wash or colour wash by scrapping with wire brush and sand paper and preparing the surface smooth including necessary repairs to Cracks and joints etc., include all cost of labour etc. including all lead and lift all complete as per the direction of Engineer-in-Charge.Ground Floor |
| 125 | Dismantling cement concrete (1.00 Cum) including stacking the useful materials for reuse and removing the debries within 50mtr |
| 126 | Providing 25mm thick Artificial Stone flooring on floors of cement concrete(1:2:4) using 12mm size hard broken granite chips including punning mixed with red oxide pigment with 4mm glass strips etc. incuding all cost of labour, material, conveyance, royalities, loading, unloading, T&P etc. complete in all respects as per direction of the Engineer -in-charge. |
| 127 | Providing neat cement punning to wall surface inside and outside etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, .including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties,watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 128 | Providing and Fixing Unistone or equivalent premium Da Vinci Cultured Stone in Khondalite natural stone pattern & shade & approved size in 15 mm thickness, ± 2mm accepted tolerance along with corner pieces at all corners of building in sizes, as available with manufacturer. The pattern should replicate natural stone appearance using differential textured mould technique and pigmentation should be done by infusion methodology to infuse surface with authentic natural tones. Dual or triple tone shading cultured stone should be casted using homogenous base pigmentation with top layer differential shade penetration technique to simulate ultra‐ realistic natural stones. The pattern should have variation in shade and have hints of rust, rust browns, copper, umbers and deep yellows to simulate actual stone. The material should be casted in controlled production environment concrete mix design with high pressure vibratory methodology, 43 – grade OPC white Cement, reinforced with Alkali Resistant Glass fibre1.5 %, The glass fibre shall be alkali resistant (AR) with minimum Zirconium Dioxide (ZrO2) content of 16% and shall be manufactured by approved manufacturer as per specification of approved make i.e., by M/s N.E.G Japan or Owens Corning. The stone cladding cultured stone should be pigmented with synthetic mineral iron oxide non fading weatherproof, UV resistant pigments of M/s Phenochem, Lanxess or equivalent and it. The product should be applied on rough plastered substrate (1:3) Cement and Coarse Sand and should be applied with Unistone ‘Ultimate’ or equivalent Exterior Grade high strength cementitious polymer modified tile adhesive having tensile adhesion strength ≥ 2.5 N / mm2 as per EN ‐1348. The product should be applied with adequate grooves and all horizontal and vertical grooves to be filled and pointed with a mix of fine sand and cement in ratio (3 Fine sand: 1 Cement). All work should be carried out as per manufacturer’s and as per direction of Engineer in charge |
| 129 | Supply , stacking and levelling of stone aggregate of size 25mm to 40 mm etc as per the direction of Engineer-in-charge. |
| 130 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom as per Clause 503 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 131 | Providing and laying bituminous macadam grade II with hot mix plant using crushed aggregates of specified grading premixed with bituminous binder of 60/70 penetration grade of bitumen, transported to site, laid over a previously prepared surface with a hydrostatic paver finisher with sensor control to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per Clause 504 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 132 | Providing and laying semi dense bituminous concrete grade II with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder of 60/70 penetration grade of bitumen, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheelede, vibratory and tandem rollers to achieve the desired compaction as per Clause 508 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 133 | Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means as per Clause 502 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 134 | Providing and fixing Dewatering Discel pump having discharge 40cum/hour including cost of operator, helper , maintenace of pump, shifting location, fuel cost etc as per direction of engineer in charge.(Pump with 20HP diesel engine for pumping of water. ( Measurement to be taken on actual hour basis based on the record in Lob book issued by the concerned department and signed by both parties) |
| 135 | Earth work in excavation of slushy soil in water upto 0.60m in water by Manually means in over areas excluding dewatering of wherever required, including all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed within all lead and lift including cost of all labours/ equipments , taxes, sundries and T&P etc all complete as per the direction of Engineer-in-charge. (Measurement be taken in level section only ). |
| 136 | Supplying, stacking and spreading of black cotton soil etc at site including royalty and carriage upto 5 km complete |
| 137 | Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site by mechanical means within a lead of 5kms, spreading, grading to required slope and compacting to meet requirement of table 300-2 & Clause 305 of MoSRT&H Specifications for Road & Bridge works(4th Revision) |
| 138 | GRAFIX GYPSUM CEILING:- Supply and installation of AnutoneSerge Astral Clip-in Bild Grafix , Sj having 1.8mm perforations /Non Perforated - In Perforated TOA 20%, Non Prof TOA -0% Aluminium core(3105 Grade) ceiling panels, backlined with Soundtex black acoustical fleece, 600x600/1200x0.6mm having weight 2kg/m2, square edge, bulkheads made up of aluminium / multi layer coil coated sheets /rolls installed in ceiling using Anutone Spring-T system.\\"Anutone Spring-T system of 600x600mm module includes Anutone Skelet WA15W30,sectional thickness 0.4mm, with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers.Then Anutone Hold-on ceiling clamp hung from the soffit at 600mm centers bothways with Hanger rod and soffit cleat .Any Type Of Grafix Will BeCustomies & High Quality Resolution Share By Clint (soffit cleat not by Anutone). Anutone Strut Spring-T is then held in position by hold-on clamp @ every 600mm centers. Anutone Astral Plus Clip-in ceiling tiles 600x600x0.6mm are then clipped into Spring-T.The system is backlined with acoustic infill of Anutone Synth PF 10x50,adhered on wall with dab spots of Anutone Stick S7/held in position with wire emsh (wire mesh not by Anutone).\\"Technical Parameters• Fire (Class) – A• Acoustics – NRC 0.75 Mensa Aulia-nil (For E300 Mounting) • Thermal conductivity (W/mk)– na• Climate (°C, RH) – 50, 99• Light reflectance (%) – 75• Green (VOC, RC %) – Low, 25 |
| 139 | PLAIN GYPSUM CEILING :- Providing fitting and fixing of false ceiling with Gypsum board with NRC value not less than 0.60 suspended false ceiling (single/double layers) in different levels, recesses, flat areas as per design with G.I. Framework (of perimeter channels, intermediate channels and ceiling sections) and 12.5 mm taped edge gypboard screw fixed to ceiling section as per design, complete with fixing and finishing of tapered and square edges of board with jointing compound paper tape including all cost of materials, labour, overheads T & P etc., complete. The Contractor has to take care in providing and painting the Gypsum Board ceiling area with one coat of primer & two coat of plastic emulsion paint as per the detail design and specification |
| 140 | ACCOUSTIC GRID CEILING :- Providing & Fixing of Fibre Glass Acoustical Suspended Ceiling System with 600X600X15mm thick Optra Microlook 90 Edge Tiles with Knauf Silhouette 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 20/25mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%. The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect . |
| 141 | OPEN CELL ALUMINIUM FALSE CEILING :- Providing & Fixing horizontal level Open cell Aluminium false ceiling system and shade, comprising of main and secondary blades of width 10 mm and height 40 mm made of 0.50mm thick Aluminium coil coated sheet grade 3003/3105, cross connected to form 150x150mm square cells laid on the 15 T grid system & accessories as per manufacturer's specifications and approved by engineer in charge and shall have sufficient loaded carrying capacity including any additional support members wherever required for light fixtures, AC diffusers, etc. |
| 142 | LAMINATED FALSE CEILING :- Providing and fixing of wooden false ceilling with 19mm bwp PLY frame work and then fixing 6 mm th bwp ply to it over which is finished with 1mm th SUEDE /TEXTURE laminate & fixed by means of MS frame work & polished with mellamine including all the cost of material & labour , t& p etc complete and as per the direction of EIC / ARCHITECT . |
| 143 | TRUE CEILING :- Providing and fixing Heradesign Superfine, 1 layer magnesite bonded wood wool acoustic panel, 1mm thick fibre, exquisite surface structure, building biology recommended, size 1200 x 600 x 25mm, having edge detail SK-04 weight 11.30Kg/Sqm, fire protection class B-s1,d0 as per EN 13501-1 & Humidity Resistance of 95%. Thickness Tolerance T2 (±1 mm/± 2 mm for 600/1200mm lengths respectively) according to EN 13168. Wood wool panels to be PEFC certified & should bear the Forest Stewardship Council Seal confirming that the wood used originates from responsibly managed forests. Directly fixing on roof with Screw. or wood/ ms frame work to de doen for uneven surface wherever if required. The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect . |
| 144 | CARPET FLOORING :- Supplying & fixing of 100% commercial grade Nylon Carpet Tile of 500x500mm of solution dyed nylon 6.6 ( Invista AntronLumena) quality or equivalent, manufactured in Japan, Machine Gauge 1/10” or more, backing of glass fiber+ PVC and made of basic fabric of Nonwoven Polyester and having properties of Super Soil Guard ( SSG) or more, total height upto 7 mm, smoke density( ASTM E 662) less than 450, anti static less than 1.0kv (JIS-L4406 STROLL 23 C. degree 25%R.H.), electrostatic propensity – maximum average 0.5kv (AATCC 134) Color fastness to light- rating 5.0= No change (AATCC 16) critical radiant flux –( ASTM E 648) Class 1 average CRF 0.48 / cm2 or higher certified It is absolutely mandatory that the manufacturer has valid certifications of CRI PLUS certified, GLP 8200, certified from Green Building Council. The cost inclusive of all cost of labour,material,sundires t&p all complete as per the direction of Engineer-in-charge. |
| 145 | VINYL FLOORING :- Providing and fixing PVC sheet flooring of thickness of 2mm with the size of 2m x 20m . The product should be homogeneous and single layered with PUR range. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC with ‘ Diamond 10 & TRUESHIELD’ technology, Plasticizers without DOP, Urethane, color pigments and filler calendared to form a sheet. Color and pattern details shall be dispersed throughout the thickness of the wear layer. It should conform to group \\"T\\" wear resistance as per EN 649, Clean Room certified with class 'A' as per ASTMF5100, Flammability resistance of class Bfl-s1 as per GB8624-2006, Dynamic coefficient of friction of class DS as per EN 13893, Thermal Resistance of 0.072m2K/W as per EN 12667, Thermal conductivity of 0.071W/mK as per EN12524, impact sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9 as per DIN 51130, Residual indentation of 0.03mm as per GB/T 4085-2005, Color fastness rating of ≥6 as per ISO 105-B02, total weight being 2.8 kg/m2 as per EN430. The product shall be suitable for applications in class 23/34/43 areas as per EN685. Product shall exhibit antistatic behavior, resistance to bacteria, resistance to chemical, resistance to staining, suitability to castor chair. The product shall be Floor Score certified with no SVHC content published by European Chemicals Agency (REACH). Product shall contribute to LEED points under Indoor environmental quality category. The cost inclusive of all cost of labour, material sundires t&p all complete as per the direction of Engineer-in-charge. |
| 146 | WOODEN PANELING WITH LAMINATE :- Providing and fixing wooden panelling suitably fixed to the walls with 19 mm thick WPC finished with 1 mm thick texture / suede laminate complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish enamel paints / polish with mellamine to match with the shade of the Laminates. The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect . |
| 147 | WOODEN PANELING WITHOUT LAMINATE :- Providing and fixing wooden panelling suitably fixed to the walls with 19 mm thick WPC finished with smooth surface complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish enamel paints / polish with mellamine to match the shade. The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect . |
| 148 | ACCOUSTIC PANELLING :- Providing and Fixing of Optra Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. ( Acoustic wall for Conference hall). The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect . |
| 149 | MCM CLADDING :- MCM OASIS SERIES :- Providing and Fixing of MCM Modified Clay Material - MCM OASIS SERIES 1200 x 600 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139)manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15.The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 150 | MCM TRAVENTINE STONE :- Providing and Fixing of MCM Modified Clay Material - MCM TRAVENTINE STONE 1200 x 600 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC,Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 151 | MCM ITTIMI CLAY :- Supply and fixing of MCM Modified Clay Material - Ittimi 1800mm x 500mm, 1200mm x 600mm & 1350mm x 600mm of PHOMI make, as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15.The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer /Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer incharge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 152 | MCM BRICK CLADDING :- Supply of MCM Modified Clay Material ‐ MCM K Series Bricks of PHOMI or VANJOIN make, sizes of 225x60mm, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation ‐ Class A— ASTM E84‐ 15.The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 153 | DOUBLE SKINNED FULL HEIGHT SOLID PARTITION FINISHED WITH BOTH SIDE LAMINATE:- Providing , fitting and fixing up partition walling with aluminium anodized section no 9210 and 9207 as single groove and double respectively as horizontal and vertical member and section 4660 as tapered clip and joining angle no 1855 etc. including 12 mm th bwp ply , 1mm th suede/ texture laminate both side on it. as per the design and specification with necessary teak wood plain / moulded beading including the cost of all materials , labour , nails, screw adhesives, overhead T & P etc. complete. The exposed frame work shall be finished with mat finish automotive paint or polish with mellamine as per the directions of the EIC/Architect. |
| 154 | DOUBLE SKINED SOLID PARTITION WITH 8MM THICK GLASS GLAZED FINISHED WITH LAMINATE :- Providing , fitting and fixing 95mm thick double skinned full height partition suitably fixed to the wall and floor and storage unit with19 mm th bwp ply frame work / almunium frame work of size 37mm x 63x1.6 mm with angle section 40x 25x1.5 mm at 600 mm C/C with 12mm thick bwp ply on both side and finished with1mm thick laminate , 8 mm th glass & 50 micron etched glass as per the design and specification with necessary teak wood plain / moulded beading including the cost of all materials , labour , nails, screw adhesives, overhead T & P etc. complete. The exposed frame work shall be finished with mat finish automotive paint or polish with mellamine as per the directions of the EIC/Architect. |
| 155 | BOTH SIDE LAMINATE PARTIALY GLAZED DOOR :- Providing and fixing ISI marked flush door with both side laminated & partialy glazed (8mm th Acoustic clear / frosted glass) shutters confirming to IS 2202 (Part1) of 32mm thickness including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as SS Concaled Hinges (5\\"), door magnet , Handle with lock , floor spring etc. The cost inclusive of edge bidding with 6mm thick lipping, including cost of all labours, materials, conveyance, hardware fixing, loading and unloading, sundries and T&P etc all complete as per direction of the Engineer -in-charge. excluding gst . |
| 156 | TOUGHENED GLASS DOOR WITH ALLUMINIUM FRAME :- Supply & Fixing of Glass Door of 8mm toughened glass with Alexa System-100 frames all around the door. Alexa DP100-DG-GD Glass Door Profile frame of size 100x50mm with seals with DORMA Junior Office Hinges (3nos) & Studio Gala Locks (1no) in aluminium silver (EV1) finish and DORMA TS 89 Slide Channel Door closer with (as per EN 1154) and saddle plate for fixing on the Glass door and necessary seals to be provided all around the door frames. In case of Glass overpanel Alexa OHP-DP100-DG Over Panel Door profile to be used. The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles Frames: DORMA, Glass : Saint Giobain. etc including cost of all labours, materials, conveyance, hardware fixing, loading and unloading, sundries and T&P etc all complete as per direction of the Engineer -in-charge. excluding gst . |
| 157 | LOW HEIGHT STORAGE :- Providing & fixing of LOW HEIGHT STORAGE made out of 19 mm thick bwp ply , 8 mm th WPC ply at BACK side & laminated with 1 .0 mm th sued/ TEXTURE laminate on out side & 0.8 mm th laminate at in side , the exposed wooden surface edge binding to match the laminate with central locking, shutters with autoclosing hinges and handles. Including all cost of labour , taxes T & P etc as per the detail design & specificatio approved by EIC . |
| 158 | FULL HEIGHT STORAGE :- Providin & fixing of FULL HEIGHT STORAGE made out of 19 mm thick bwp ply ,8 mm th wpc ply at back side & laminated with 1 .0 mm th sued/ TEXTURE laminate on out side & 0.8 mm th laminate at in side , the exposed wooden surface polished with mellamine or painted with automotive paint with central locking, shutters with autoclosing hinges and handles. Including all cost of labour , taxes T & P etc as per the detail design & specificatio approved by EIC . |
| 159 | BOOK SHELF :- Providing and fixing of book self made out of 19 mm th bwp ply ,12 mm th edge polish glass & finshed with 1 mm th laminate , surface at out side . All beading to be finished with mellamine polish to match the laminate as per the detail design and specifications and inclusive of all cost of labour, hardwares T&P etc complete as per the directions of the EIC/Architect. |
| 160 | CONSOLE/DISPLAY UNIT WITH CORIAN TOP:- Providing, fitting and fixing the console /display unit made of 19mm bwp ply and finished with 1mm thick texture / suede laminate, 12 mm th glass shelf wherever necessary and 12mm thick corian on top and the exposed edges & wooden surface are to be finished with wooden lipping and finshed with automative paints/polish with melamine finish as per approved design and specifications including cost of all materials, labour, hardware if any etc. complete as per the detail design & directions of the EIC. |
| 161 | WOODEN PLANTER BOX UPTO HEIGHT 450 MM WITH LAMINATE FINISH :- Providing and fixing of planter box made out 19 mm th bwp ply \ wpc , & finshed with 1 mm th LAMINATE at ouert side and inside . and polycarbonate sheet inside the box for water resistance. All beading & outer surface to be finished with mellamine /pu polish to match the laminate as per the detail design and specifications and inclusive of all cost of labour, hardwares T&P etc complete as per the directions of the EIC/Architect. |
| 162 | Supplying and fixing of painting & art work made out of acrylic painting on canvas with pvc framing , 5mm th glass on top & 6mm ply on back side of the painting as per design approved by eic . |
| 163 | Providing and Fixing of Following types of signage to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the WPC board with fixing of the same along with Rates, Taxes, T&P all inclusive.3D signage with graphic design on 4”/6” ACP base with 6mm raised letters (with out lighting) |
| 164 | 3D signage with graphic design on 4”/6” ACP base with 6mm raised letters (with lighting) |
| 165 | 3D signage with graphic design on 4”/6” ACP base with 3M vinyl sticker letters |
| 166 | 3D graphics in laser cut/engraved veneer finished with PU |
| 167 | Providing & supplying both side Sandwich glass signage of size 900mm x600 mm for fire map display as per the approved shade and design Including all cost of labour , T & P etc as per the detail design & specifications approved by EIC (Size should be change as per the design and drawing and as per the direction by Architect. |
| 168 | Providing & supplying ss signage of different size as per the approved shade and design Including all cost of labour , T & P etc as per the detail design & specifications approved by EIC 150 x 150 mm |
| 169 | 150 x 450 mm |
| 170 | 150 x 300 mm |
| 171 | Providing & fitting fixture of 3M Premium Wall paper for Wall & Partition with Water Resistant Coating as per the approved shade and design Including all cost of labour, taxes T & P etc as per the detail design & specifications approved by EIC . 3M Premium Texture |
| 172 | 3M Premium Premium calssic Texture |
| 173 | 3M Premium canvas Texture |
| 174 | Providing & supplying of HOME DUSTBIN PADDLE 12L as per the detail design & specification including all cost of labour , material hardware ,etc excluding gst approved by eic. |
| 175 | Providing & supplying of TWIN DUSTBIN 10 LTR as per the detail design & specification including all cost of labour , material hardware ,etc excluding gst approved by eic. |
| 176 | Providing and supplying stainless steel dustbin of size 10 inch diameter and height 14 inch will be for work station area etc. including cost of all material ,labour ,t&p etc all complete. |
| 177 | Providing and supplying White Lacquered Glass Writing Board using the ANS Glass dry erase whiteboard, a sophisticated writing surface. Special finish provides a smooth writing surface that will not ghost or stain. Strong MDF base provides strength to glass and secures it. Glass enhances the looks of your premises and uplift the dullness of spaces. |
| 178 | Providing and supplying Nilkamal 60 L Green Plastic Garbage Waste Bin of environment friendly etc. complete as per the direction of Engineer-in-charge. |
| 179 | Providing & supplying of Foldable Wheelchair for Elderly & Patients | Self-Propelled | MS Frame with Hammered Finish | Travel-Friendly, Indoor Use | Adjustable Seat Belt & Comfortable Footrests (EC700_BR_LOCK)etc. complete as per the direction of Engineer-in-charge. |
| 180 | Providing & supplying of Airmax Novo scent diffuser for theofficial , with a beautiful finish. Small in size and coverage, this scent diffuser is best for areas up to 90 Cubic Meter. The battery-operated fragrance delivery system can also be used with the power cable. This diffuser takes 100ml aroma oil as a refill. etc as per the direction of Engineer-in-charge. |
| 181 | Providing & supplying and planting different type of indoor plants of height not less than 450mm and etc including of plastic pot with tray etc as per the direction of Engineer-in-charge. The cost inclusive of all lebour, material, good earth , sludge transportation , loading and unloading and lifting etc all complete |
| 182 | Godrej Make 2 SEATER SOFA MODEL- PISA 2 SEATER(SIZE - 1460H x 905D x 855H,450SH) IN MM |
| 183 | Godrej Make 1 SEATER SOFA MODEL- PISA 2 SEATER(SIZE - 860H x 905D x 855H,450SH) IN MM |
| 184 | Godrej Make CENTER TABLE MODEL - PISA CENTER TABLE |
| 185 | Godrej Make RECEPTION CHAIR MODEL - BRAVO MID BACK CHAIR |
| 186 | GODREJ MAKE RECEPTION TABLE MODEL - REFLECTION 5FT WIDTH LEANER DESK |
| 187 | Godrej Make Table - TABLE CIGNUS 2100 + ERU+ PEDESTAL + BACK UNIT 1800 (TABLE MAIN DESK SIZE - 2100W X1050D x 750H, ERU-1200Wx450Dx750H),BACK UNIT SIZE - 1800Wx500Dx1800H) IN MM |
| 188 | Godrej Make Chair - BEAT HIGH BACK W/O SLIDING |
| 189 | GODREJ MAKE VISITOR CHAIR MODEL-BEAT VISITOR |
| 190 | Godrej Make Almirah - Storwel Plain (1981H x 916W x 486D) |
| 191 | Godrej Make SLOTTED ANGLE RACK MODEL - EASY RACK 8818 (SIZE - 2400Hx900Wx450D) IN MM |
| 192 | Godrej Make Elbe Motorised 1-Seater Fabric Recliner Sofa |
| 193 | RECEPTIOPN TABLE :- Providing & supplying of Reception table of width 900 , height 1050 WITH storage OF SIZE 450 Xx450x750 made out of 19 mm th bwp ply & finished with 4 mm th veener on out side , glass , ss pipe, 6mm TH solid surface where ever necessary . & inner surface finished with 0.8 mm th laminate & beading & outer surface to be finished with mellamine polish including all types of material, labour , hardware etc. as per the detail design & specifications approved by EIC . excluding gst . |
| 194 | RECEPTION BACK DROP :-Providing and fixing of 75-150 thick parttition finished with 4mm th veener / vinyl sheet / 6 mm th solid surface / sand stone /19 MM TH Onyx as a backdrop for the Reception. The structure shall be made of 19 mm th bwp ply members and then over it 6mm bwp ply shall be fixed and the solid surface shall be fixed to the partitions. The joints shall be finished with silicon adhesive to match with the shade of the solid surface , the veener surface polished with mellamine as per the detail design and specifications and inclusive of all cost of labour, materials, T&P etc complete as per the directions of the EIC/Architect. excluding gst . |
| 195 | OFFICERS' TABLE :- Providing and fixing of table of 1800X750(w)x750 ht made out of 19 mm th bwp ply finshed with 1 mm th texture & suede laminate on top , 1mm th laminate on vertical side , 0.8 mm th lamnate inside the storage .All edges are finished with pvc edge binding to match the laminate as per the detail design and specifications and inclusive of all cost of labour, hardwares T&P etc complete as per the directions of the EIC/Architect. ) excluding gst . |
| 196 | DINING TABLE :- Providing & supplying of Dining table made out of teak wood frame . The top of the table is 12 mm th bevelled glass .All the exposed wooden surface to be polished with mellamine including cost of all materials, labour, hardware as per the detail design approved by the EIC.4seater rectangle table of size 1500x900x750 |
| 197 | 8seater rectangle table of size 2400x1050x750 |
| 198 | DINING CHAIR :- Providing & supplying of Dining chair of size 46cm x 56cm x 100cm made out of teak wood as per the detail design approved by the EIC.Dining chair of size 48cm x 44cm x 1m with cusion seat |
| 199 | Dining chair of size 45cm x 59cm x 90.5cm with seat & back cusion |
| 200 | RECEPTION CHAIR :- Providing & supplying of MB ADJ ARMS CHAIR ( GRY/BLACK )* Fabric Uphoistered Cushion Seat* Self Calibrate Multilock Mecanism* Adjustable lumber support* One Way Adjustable Arms ( Height )* Nylon Base including all cost of labour, material hardware ,etc excluding gst approved by eic . |
| 201 | OFFCIE CHAIR :- Providing & supplying of MBGS ADJ ARMS CHAIR * Revolving Chair with Mess Backrest* Synchro single locking Mecanism* Adjustable lumber support* Adjustable Arms ( Height )* 5 prong Nylon Base with Castor * Gaslift for Height Adjustment including all cost of labour, material hardware ,etc excluding gst approved by eic . |
| 202 | Supply and installation of Stainless steel chair of silver colour etc as per the direction of E-I-C. |
| 203 | Supply and installation of Reception Table r (SIZE - 1500W x 750D x 740H) IN MM as per the direction E--I-C |
| 204 | Supply and installation of Push mid back chair etc as per the direction of E-I-C |
| 205 | Supply and installation of Aquaguard Pro Pure Chill 80 SS RO+UV+CUZN Water Cooler with Water Purifier |
| 206 | P.H. Work |
| 207 | P.H Work Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Ashirbad/Supreme/Oripalst/Shaakya)GF Floor -20mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 208 | 25mm dia C-PVC pipe |
| 209 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Ashirbad/Supreme/Oripalst/Shaakya)Ground Floor 25mm UPVC ASTM Pipe |
| 210 | 32mm UPVC ASTM Pipe |
| 211 | 40mm UPVC ASTM Pipe |
| 212 | 50mm UPVC ASTM Pipe |
| 213 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.G. Floor |
| 214 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in chargeG. Floor |
| 215 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall G. Floor |
| 216 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 217 | 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN |
| 218 | 15mm dia CP S.B Bib cock (CON-CHR-037KN) |
| 219 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN |
| 220 | 15mm dia CP angle stop cock (FLR-ACR-5053N) |
| 221 | 15mm dia CP SINK cock (Jaquar)FLR-CHR-5347N |
| 222 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 223 | HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565 |
| 224 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN |
| 225 | Shower Arm (SHA-CHR-477) |
| 226 | Over head shower 100mm dia round (OHS-CHR-1999) |
| 227 | 25mm dia brass or gun metal full way valve(shakti make) |
| 228 | 32mm dia brass or gun metal full way valve(shakti make) |
| 229 | 40mm dia brass or gun metal full way valve(shakti make) |
| 230 | 50mm dia brass or gun metal full way valve(shakti make) |
| 231 | 15mm dia CP Flange |
| 232 | 15mm dia CP Extention Nipple |
| 233 | 125mm CP grating |
| 234 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Ground floor |
| 235 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In (Ashirbad/Supreme/Oripalst/Shaakya)Ground floor |
| 236 | 110mm dia U-PVC SWR pipe |
| 237 | 75 mm dia UPVC SWR Pipe |
| 238 | 110mm U-PVC door tee |
| 239 | 110mm U-PVC Plain tee |
| 240 | 110mm U-PVC door bend |
| 241 | 110mm U-PVC plain bend |
| 242 | 110mm dia U-PVC 'P' trap |
| 243 | 110mm dia U-PVC Plain Shoe Bend |
| 244 | 110mm dia U-PVC offset with out ear |
| 245 | 110mm dia U-PVC cowl |
| 246 | 75 mm dia UPVC plain bend (supreme/ashirvad) |
| 247 | 76 mm dia UPVC plain Tee (supreme/ashirvad) |
| 248 | PVC clamp suitable for 75 mm to 110mm dia pipe |
| 249 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware/Hendware/Cera/Somany/Kerovit) |
| 250 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 251 | Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan ((Parryware/Hendware/Cera/Somany/Kerovit) |
| 252 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) (head)70002 |
| 253 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hendware/Cera/Somany/Kerovit) |
| 254 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 255 | 15mm dia urinal spreader |
| 256 | 32mm dia C.P. dome waste |
| 257 | Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. Squatting URINAL pan (Parryware/Hinware/Sanituf) |
| 258 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks (Plaza make)and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge 550mmx400mm W.H.basin with porcelain pedestal & Jaquar make fittings(Parryware/Hindware/Neycer/Rak) |
| 259 | Under Counter Basin (560x455) (H)10095 white |
| 260 | Half pedestal Basin(Hindware)No.91049+91115 |
| 261 | Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge |
| 262 | 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make) |
| 263 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 264 | CP Towel ring |
| 265 | Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge. CP soap holder |
| 266 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm glass shelf with CP/NP guard rails |
| 267 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 268 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 269 | SS Stand for Aquaguard |
| 270 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 271 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 272 | R.C.P.C Cover |
| 273 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 274 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 275 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 276 | 110mm dia U-PVC Alround Concrete |
| 277 | 160mm dia U-PVC Alround Concrete |
| 278 | Construction of 50 users RCC septic tank-1 No |
| 279 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 280 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 1x6.10x2.70x0.30 |
| 281 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 282 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 283 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 284 | In ground floor |
| 285 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 286 | In ground floor (inside/outside) |
| 287 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 288 | In ground floor (inside/outside) |
| 289 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 290 | R.C.C floor and roof slabs up to 4.30m height |
| 291 | R.C.C beams,columns,girder and bressmer etc. |
| 292 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 293 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 294 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 295 | In ground floor |
| 296 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 297 | In ground floor |
| 298 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 299 | In F&P |
| 300 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 301 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 302 | Supplying all materials, labour,T&P and providing 25mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips on new work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 303 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 304 | Dewatering with 5 H.P diesel engine pump during excavation |
| 305 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 150mx150mx150m as per P.H.D.specification and direction of the E.I.C. |
| 306 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 307 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 308 | 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 309 | 110mm U-PVC cowl |
| 310 | Construction 1 nos 100 users RCC Septic tank |
| 311 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 312 | - do - with addl. Depth of 1.5 m |
| 313 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 314 | Supplying all materials, labour, T&P and providing shoring and shuttering for foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per specification and direction of the Engineer in charge |
| 315 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 316 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 317 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 318 | For Roof slab |
| 319 | For RCC wall |
| 320 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 321 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 322 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge |
| 323 | 110mm dia UPVC Plain Tee |
| 324 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 325 | Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 326 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 327 | 110mm diameter U-PVC SWR pipe |
| 328 | 110mm dia U-PVC Plain shoe bend |
| 329 | 110mm dia U-PVC Cowl |
| 330 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 331 | Sinking of 150mm size tube well through hand boring( water jet) method) |
| 332 | Suplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 333 | Supplying all labour, T&P and transporting the boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement, bentinite and gravels etc to the worksite including loading and unloading etc all complete as per direction of the Engineer in charge. |
| 334 | Supplying all labours, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kind of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets ( whenever required) etc and withdrawing the boring pipes, washing and keeping the bore logging if required all complete as per direction of Engineer in chargeDrilling pilot bore from 0 to 360 metres |
| 335 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depth without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction off Engineer in charge.Reaming 100mm to 150mm dia from 0-360 mtr |
| 336 | Reaming 150mm to 200mm dia from 0-360 mtr |
| 337 | Reaming 200mm to 300mm dia from 0-360 mtr |
| 338 | Supplyimg all labour, T&P and jointing materials & lowering the 300mm dia top casing pipes into the position and removing the same after all complete as per direction of Engineer in chargeFrom 0-360 mtr |
| 339 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge150mm dia PVC casing pipe from 0 to 360 metres |
| 340 | Cost of 150 mm dia PVC ASTM pipe(sch-80) |
| 341 | Cost of 150mm dia Slott Cutting |
| 342 | 150 mm dia C.I.end/top cutter plug |
| 343 | Cost & Conveyance of bentonite powder |
| 344 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction off the Engineer in charge.Labour charges |
| 345 | Cost and Conveyance of gravel |
| 346 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack all complete as per the direction of the Engineer in charge.Labour charges |
| 347 | Cost and Conveyance of sand |
| 348 | Supplying all labour, T&P including developing the tube well with compressor ( supplied by contractor ) continuiously worked till clear & adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour as per direction of the Engineer in charge.Labour charges |
| 349 | Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to HDPE pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction.32mm dia HDPE Pipe |
| 350 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge1.50 single phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.P.M with outlet dia of 32mm |
| 351 | DOL Control panel |
| 352 | 32mm dia steel short piece |
| 353 | Well cap |
| 354 | 50mm size CI bracket |
| 355 | 2.50 sqmm flat cable |
| 356 | Steel rope with cover |
| 357 | 20mm dia rigid UPVC pipes |
| 358 | Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
| 359 | Supplying all materials, labour, T & P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, earthwork in excavation in all kind of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge. |
| 360 | Electrical Works |
| 361 | Sub-Head I (modular Wiring Items) |
| 362 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 363 | GROUP-A |
| 364 | GROUP-B |
| 365 | GROUP-C |
| 366 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 367 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 368 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 369 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 370 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 371 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 372 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 373 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 374 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 375 | Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 376 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 377 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 378 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 379 | Sub-Head II (Light fitting Fixture & Fan) |
| 380 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 381 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow1500 CFM @ 15mm MMWG static pressure |
| 382 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 383 | 24 gauge (0.63 mm thickness) |
| 384 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 385 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 386 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 387 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 388 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 389 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 390 | SITC of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 391 | SITC of indoor rated IP20 5mtr LED Strip, operating in an ambient temperature of 0⁰C to 45⁰C. Operating at 50Hz frequency, housing of Polymide double sided PCB. LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. Luminaire should have 70lm/mtr and total 350lumen in maximum 25Watt for 5mtr role. The LED shall comply with L70 life of 35000 burning hours tested at maximum current. The LEDs used should be with CCT of 3000/4000/5700 K. LED Driver shall be external type, suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 3KV internal surge protection, Power factor of minimum 0.9, driver efficacy of minimum 85% and total harmonic distortion (THD) of less than or equal to 20% should be integral to the luminaire. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 392 | SITC of 20 watt LED focus track light with 1mtr track as per the direction of Engineer-in-charge. (Make:K-LITE Model No- 23678 Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 393 | SITC of 12 watt LED COB light made up of die cast aluminium body & Clear polycarbonate diffuser with 100Lm/Watt, Citizen COB, IP-54, SDCM<3, CRI 90, CCT - 3000K, as per the direction of Engineer-in-charge. (Make: K-Lite Model No - 28178 / Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 394 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 395 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 396 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator).Warranty on DB is 3 years |
| 397 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB) |
| 398 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years |
| 399 | 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 400 | Supplying and fixing 6- 32 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years . |
| 401 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 402 | Supplying and fixing 40Amps 4P 415 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 403 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 404 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 405 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 406 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 407 | CABLING AND END TERMINATION MAIN AREA |
| 408 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 409 | 4core x 16 sq mm |
| 410 | 3.5core x 150 sq mm 2 RUNS MAIN |
| 411 | 3.5core x 95 sq mm |
| 412 | 3.5core x 50 sq mm |
| 413 | LAYING OF CABLE |
| 414 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 415 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 416 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 417 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 418 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 419 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 420 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 421 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 422 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 423 | Supplying and making end termination with 3.5 core x95 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 424 | Supplying and making end termination with 3.5 core x150 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 425 | Supplying and making end termination with 3.5 core x50 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 426 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 427 | 50 mm dia |
| 428 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 429 | Supplying,laying of 3cx2.5 sq.mm AL armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 430 | Supplying,laying of 3cx6 sq.mm AL. armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 431 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 432 | 50 mm dia |
| 433 | PANELS |
| 434 | MAIN CONTROL PANEL NEAR HALL AREA |
| 435 | S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 50X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory. All the feeders shall have ON/OFF/TRIP indication. |
| 436 | In commer-1-01 number of 400A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 437 | In commer-2- 01 number of 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 438 | Changeover- 01 no of 160A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB) |
| 439 | Busbar-1&2 04 numbers of 500Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 440 | Out going- 03 numbers of 125Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 441 | Out going- 6 numbers of 100-63Amps 4P MCCB.Icu=100%Ics,16Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 442 | Out going- 03 numbers of 160Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 443 | Outgoing- 4 nos. 32A 4P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 |
| 444 | Outgoing- 8 nos. 32A 2P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 |
| 445 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 446 | (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) All the MCCB outgoing feeders shall have digital ammeter with CT of suitable class 1 rating.(Make-Legrand/Siemens/Schneider/ABB) |
| 447 | MAIN CONTROL PANEL INTERAPETION CENTER |
| 448 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 449 | In commer-1-01 number of 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 450 | Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 451 | Out going- 4 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 452 | Out going- 4 numbers of 6-32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 453 | Out going- 4 numbers of 63A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 454 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 455 | (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 456 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 457 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 458 | Supply ,installation ,testing & commissioning of 10 KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for INDOOR HALL building |
| 459 | LIGHT SYSTEM EXTERNAL |
| 460 | S/F of Street light- 120W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66, IK 08 roadway luminaire with high power LED as light source with acrylic cover (Make-Panasonic/LT/Havells /Philips/Wipro/Crompton/Bajaj) (5Years Warranty) |
| 461 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 462 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 463 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 464 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.The price inclussive of 3 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-300 + KL-5444 Luminaries / LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj). |
| 465 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/K-Lite.The price inclussive of of 4 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-400 + KL-5444 Luminaries/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj). |
| 466 | Supplying, Erection, Fixing, connection & testing of 50W LED Heritage GATE Light, Dimension of light must be Ø400mm dia and 800mm height, IP 66, IK07, amb. temp -10 to 45 degree celcious, CT 3000-5700K,,50000 HRS, CRI 70, 120 Lm/W system efficacy,driver efficiency >/ 85%,dia case aliminium housing,Clear Acrylic diffuser of Make-K-LITE Model No - 25444/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 467 | Supply, Installation, Testing & Commissioning of of IP65 (16)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-K -lite Bollard KL-25582/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 468 | FOCUS LIGHT |
| 469 | Supply, Installation, Testing and Commissioning of 18W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. Make: K -lite Nebula KL-22782/LT/Havells/panasonic/Philips/Wipro /Crompton/Bajaj). |
| 470 | Supply, Installation, Testing and Commissioning of 50W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Navi KL-26805/LT/Havells/panasonic /Philips/Wipro /Crompton/Bajaj). |
| 471 | CABLING |
| 472 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 473 | 4core x 16 sq mm (OFP TO IND. TIMER PANEL) |
| 474 | 4 core x 4 sq mm (for small power/LIGHT TO POLE) |
| 475 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 476 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 477 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 478 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 479 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make-POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster |
| 480 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 481 | 50 mm dia |
| 482 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 483 | Highmast lighting |
| 484 | Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT/Valmont |
| 485 | SITC of 250W Outdoor Flood LED lights with silicon potted driver, IP66, , bottom opening maintanance , LPW not less than 130.Input Voltage: 85-265V AC ,Body : Die cast Aluminium, IP66 as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired. |
| 486 | LED type single dome aviation obstruction light. (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT |
| 487 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 488 | Solar light |
| 489 | Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 490 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 491 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 492 | Installation of 60W AIO LED solar street light on 8 mtr octagonal pole. |
| 493 | ELV-CCTV ,PA SYSTEM |
| 494 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 495 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 496 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS). Make-Honeywell value series/ Pelco/ Axis/ Bosch |
| 497 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 498 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 499 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 500 | SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 501 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 502 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 503 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax/ Legrand/ Panduit |
| 504 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit(1 mtr length) |
| 505 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit (2 mtr length) |
| 506 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/ Digisol/ Netgear |
| 507 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax/ Legrand/ Panduit |
| 508 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax/ Legrand/ Panduit |
| 509 | SITC of 9U/500D outdoor type IP 55 Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make: Valrack/ Rittal/ Legrand |
| 510 | PA SYSTEM |
| 511 | Supply of 20 Watt outdoor Horn Speaker, IP65, Frequency Response : 150 Hz – 15 kHz, 4 INCH DRIVER, peak power handling capacity 80W, Should have Passive 350 Hz high-pass filter built-in, SPL : 133 dB peak @ 1.4 kHz, IP-65 rating per IEC529, Coverage Pattern: 60° horizontal by 80° vertical , Maximum SPL (1m): 109dB peak, 8 ohm Impedence, Transformer Taps: 70V/100V: 20W, 100V: 30 w.MAKE:Bose/EV/Audac(HS121)/Sonodyne |
| 512 | Supplying, installing, testing and commissioning of quad channel Power amplifier of continous power 4x 240 W @8 ohm and 100V, frequency response- 50Hz-20 kHz , class D amplifier.The amplifier should be clean reliable audio for public address amplification and music.Line input less than 1 volt, unbalanced& line output less than 1 volt unbalanced.Make-Bose/Audac(PMQ240)/EV/Sonodyne |
| 513 | Supply of 30 W weather proof rock speaker with LMT, IP65 , Transformer Taps: 70V/100V: 20W, 100V: 30 w Make-Sonodyne (RS 650)/Bose/EV/Audac |
| 514 | Supply of 10-Channel Mixing Console: Max. 4 Mic / 10 Line Inputs (2 mono + 1 stereo) / 4 GROUP Buses + 1 Stereo Bus / 4 AUX (incl. FX),16-Channel Mixing Console mic preamps with an inverted Darlington circuit,1-Knob compressors,High-grade effects: SPX with 24 programs,24-bit/192kHz 2in/2out USB Audio functions,Works with the iPad (2 or later) through the Apple iPad Camera Connection Kit / Lightning to USB Camera Adapter,Includes Cubase AI DAW software download version,PAD switch on mono inputs,+48V phantom power,XLR balanced outputs with provision for bluetooth.Make-Yamaha/Soundcraft/Studiomaster |
| 515 | SITC of 17U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make: Valrack/ Rittal/ Legrand |
| 516 | Speaker Cable Armoured 2 core 2.5 sqmm PVC Sheathed etc complete as required. |
| 517 | Laying of cable (Digging , laying and refilling with sand and Bricks) |
| 518 | Installation of all equipment, testing and commissioning of the system |
| 519 | EV CHARGE STATION |
| 520 | EV CHARGER |
| 521 | SITC of 60 KW, 415 V AC,50 Hz, DC charger (Dual Gun) with DC O/P 200-1000 VDC, 200 A DC A as per IS17017 with 5 years of comperhensive warranty, guarantee, AMC and ARAI certificate.charging mode4:CCS2,Auto charge, IP54 or above, forced air cooled, outdoor type in complete as per the direction of Engineer-in-charge. The price is inclusive of 2 nos.GI earth plate 600mmx600mmx6mm thick ISI marked with G.I.nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required, 25x5 mm GI strip and 50x6 mm GI strip for each plate earthing as per site requirement.Make-TATA Power/Statiq/Verde-mobility/ElectriVa/Panasonic/Siemens/ABB/Schneider |
| 522 | SITC CMS (A cloud- based charging management service with Android/IOS application and CMS portal)For 5 year.Make-TATA Power/Statiq/Verde-mobility/ElectriVa/Panasonic/Siemens/ABB/Schneider |
| 523 | SITC of 160(125-160) A outdoor Sub panel with 2mm CRCA having 200A Cu. busbar 1nos 160 A ,4p mccb 25 ka adjustable thermal based release with Ics=100%Icu as Incomer & 200 A Cu. Bus bar as outgoing feeder as required as per direction of Engg.-in -charge. Type 2 40kA 3P+N SPD with 63A 4P MCB,C series,10kA shall be provided in the incomer.Make of MCCB-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB FormulaMake of MCB-LEGRAND-DX3 / Siemens-Betaguard Model/ Schneider-Acti 9/ ABB SB200Make of SPD-Legrand/Siemens/Schneider/ABB/OBO/Dehn |
| 524 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade POLYCAB/HAVELLS/Finolex/kei/RR Kabel/Gloster ISI marked as approved of size 3.5core x 95 sq mm . |
| 525 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 526 | Supervision and Commissioning of DC Charging Station. |
| 527 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. (For bike charging) |
| 528 | TWO WHEELER CHARGING PANEL |
| 529 | S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 530 | In commer-1-01 number of 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 531 | Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 532 | Out going- 10 numbers of 40A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 533 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 534 | (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 535 | CASSETTE TYPE SPLIT UNITS |
| 536 | SITC of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU),Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50Hz, 1/3 phase AC supply. the system shall be capable of performing cooling, dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/ rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity asper relevant IS Code. The lab testing reports as per IS: 1391shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards/ Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per IS: 1391 as required. 5 Star Inverter Type- Cooling only (Category I Make :- LG/ O General/ Daikin/ Mitsubishi) |
| 537 | 4.0 TR with 5 Star BEE Rating (LG/ O General-AUGG48CRAA-B/ Daikin/ Mitsubishi) |
| 538 | AIR CONDITIONER SPLIT |
| 539 | Supply of A,C with indoor and outdoor unit |
| 540 | SITC of 1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor.The rate is inclusive of 3 mtr copper refrigerant pipe. In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item. (Make:O-General/Diakin/Mitsubishi/Hitachi) |
| 541 | SITC of 1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor.The rate is inclusive of 3 mtr copper refrigerant pipe. In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item. (Make:O-General/Diakin/Mitsubishi/Hitachi) |
| 542 | REFRIGRANT PIPING |
| 543 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 544 | 1 TR to 3 TR high wall split A.C |
| 545 | FRAME WORK |
| 546 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 547 | 1 TR to 3 TR high wall split A.C |
| 548 | DRAIN PIPING |
| 549 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. |
| 550 | 25mm nom. Dia pipe |
| 551 | Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 552 | Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 553 | FIRE SAFETY EQUIPEMENT |
| 554 | Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 555 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 556 | SIGNAGES: SITC of flexyl Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 557 | SITC of Illumination Glow light for Exit Indication with Battery Back-up.Make-Prolite/Bajaj |
| 558 | Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 58.5KVA ( Make -Kirloskar / Jakson/TMTL/Mahindra/Captiva/Sterling) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 58.5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 12 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 58.5 KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channel and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. , control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 559 | LIGHTENING PROTECTION SYSTEM--- Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 560 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 561 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 562 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 563 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 564 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 565 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB |
| 566 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 567 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 568 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 569 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 570 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 571 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 572 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 573 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 574 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 575 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 576 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 577 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 578 | AV SYSTEM |
| 579 | SITC of 5200 ANSI Lumens, 3 LCD system Laser Projector with 16:10 Aspect Ratio, WUXGA (1920X1200 Pixels) Resolution. Contrast Ratio 3,000,00:1, Lens 1.6x manual zoom. With mounting bracket.Make: Panasonic model-PT-VMZ51S , Veiwsonic, Barco |
| 580 | SITC of imported allmost seamless join, screen size 18' X 32', microperforated fabric, completed aluminium frame screen with a velvet covered.Make: Suvira, Elite, Lumina |
| 581 | SITC of loudspeaker which provides a high quality high performance speaker system for behind the screen home theatre systems.The loudspeaker incorporates true point source technology and is a 2-Way passive loudspeaker containing a 1” exit compression driver assembled in a coaxial configuration along with a 12” LF driver providing a conical 90° opening. 12″ (308 mm) Low Frequency Driver and 1.5″ (38 mm) High Frequency Driver. High performance coaxial driver. 90° conical dispersion. High SPL. Smooth frequency response on and off axis. Frequency Response 65Hz to 20kHz. Power Rating 400W AES, 1600W peak. Sensitivity 98dB 1W/1m. Maximum SPL 124dB continuous, 130dB peak @1m. Finish: Black impact resistant structured coating. Make: Pulz,model-CX12SMP, Martin Audio, L-Acoustic |
| 582 | SITC of High power and high sensitivity 2 x 10” (250 mm) woofer. 100° vertical control Only 12” (300 mm) depth for in wall installation.It is designed to be an inwall or onwall subwoofer system where powerful low frequency extension and ease of integration is the prime criteria. Frequency Response 38Hz to 500Hz. Power Rating 500W AES, 2000W peak. Sensitivity 95.5dB @ 1W/1m. Maximum SPL 122dB continuous, 128dB peak @ 1m. Nominal Impedance 4Ω. Dispersion 180° horizontal, 100° vertical @ 400Hz. Transducers 2 x 10” (250 mm) long throw weather resistant woofer. Make: Pulz model- IW210, Martin Audio, L-Acoustic |
| 583 | SITC of 2-Way Cinema Surround Speaker System, designed to reproduce faithfully the wide dynamic range and extended frequency response to meet today’s immersive audio formats. Frequency Response 65Hz to 20kHz. Power Rating 100W AES, 400W peak. Sensitivity 93.5dB @ 1W/1m. Maximum SPL 113.5dB continuous, 119.5dB peak @ 1m. Nominal Impedance 8Ω. Low Frequency Driver 8″ (200 mm) Mid-Bass drive. High Frequency Driver 1” (25 mm) Dome tweeter. Crossover 2.5kHz Passive, low loss air core inductors and MKP capacitors. Finish Black impact resistant structured coating. Connector Push type binding post, cable upto 4 mm diameter.Make: Pulz model-ES8, Martin Audio, L-Acoustic |
| 584 | SITC of a 4 channel power amplifier specially designed for today’s competitive multiplex environments. The robust bipolar outputcircuit combines clean power with superb dynamics and can accurately drive a variety of speaker systems.Frequency response 30Hz - 20kHz, +0.2dB. Total Harmonic Distortion + Noise <0.01% 20Hz - 20kHz @ 8Ω. Inter modulation Distortion <0.03% SMPTE @ 8Ω. Signal to Noise Ratio -94 dBDamping factor >100 @ 8Ω. Cross-talk -90dB. Slew Rate >10V/µs. Input Sensitivity 1.4V (+4dB). Input Impedance 20kΩ, balanced. Voltage Gain 32dB. Bandwidth 100 kHz. Make: Pulz model-UL4500 , Martin Audio, L-Acoustic |
| 585 | SITC of Premium 7.2 Channel AV Receiver Powered by HEOS™ with Dolby Atmos, 100W, 8K and 6 HDMI Inputs,100 Watts per Channel,HEOS Built-in.Make: Dolby,model-Cinema60, Denon, Marantz |
| 586 | SITC of 2 core 4 sqmm speaker Cables. |
| 587 | SITC of 2 core 6 sqmm speaker Cables. |
| 588 | SITC of 20mtr HDMI cable |
| 589 | SITC of required connectors |
| 590 | SITC of 9U AV rack |
| 591 | Lobby Area |
| 592 | SITC of Sorround Speakers along with Ceiling Mounting Brackets: The Speaker should be Coaxial and provide a Dispersion Angle of 90 Degrees Conical and be capable of delivering a combined SPL of 105dB continous pink noise at the RLP at 2/3rd distance with maximum throw distance of 25ft with a frequency response of 65HZ to 20KHZ. The speaker should be composed of Minimum 8\\" Driver, each having power handling of 120 Watts AES, Sensitivity of 93dB @ 1 Watt 1 Metre or higher. The speakers should be course texture. All metal parts should be power coated or stainless steel.Make: Pulz model-CMX8 With bracket, Martin Audio, L-Acoustic |
| 593 | SITC of 6 Channel Power Amplifier Each amplifier should deliver a minimum power of 200 watts per channel @ 8 ohms, and 300 watts per channel @ 4 ohms. The frequency response should be 30Hz to 20kHz. The damping factor is greater than or equal to 100 @ 8 ohms, and the minimum signal-to-noise ratio is -95dB.Make: Pulz model-PZ6300, L-Acoustic, Martin Audio |
| 594 | SITC of Pre-amplifier with Frequency response ,Left & right out - filter @ 40Hz 40Hz to 30KH ,Left & right out - filter @100Hz 100Hz to 30KHz ,SW out 20Hz to 100Hz,Input sensitivity for rated output 2V (+8.6dB) ,Balanced in 270mV ( -9dB). Unbalanced in 150mV ( -14dB),Tone controls Bass ± 10dB @ 100Hz Midrange ± 10dB @ 1KHz ,Treble ± 10dB @ 10KH.Signal to Noise Ratio ref to rated output 2V (+8.6dB) -80dB, Make: Pulz model-XO23, L-Acoustic, Martin Audio |
| 595 | SITC of mixer amplifier with Frequency Response 20~20KHz (+1dB ~ -3dB) at 4ohms, SNR >89dB (with A-Weight) , Speaker output 100V / 70V (USA version) / 4Ω,With built-in Mp3 supports many audio format like Mp3,WMA, WAV, APE, FLAC etc.Make: Byford model-MA80USB Audio, Yamaha, Behringer |
| 596 | SITC 2 core 4 sqmm speaker Cables |
| 597 | SITC of required connectors |
| 598 | SITC of 6U AV rack Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail