Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation in all kinds of soil within 50 m linital lead and 1.50m initial lift including rough dressing breaking clods to maxikum 5cm to 7cm and laying in layers not exceeding 0.3M depth and as per OPWD Specification and direction of the Engineer-In-Charge. |
| 2 | Earth work in excavation of foundation in all kinds of soil beyond 1.50 m to 3.0 mtr depth with initial lead and lift including rough dressing breaking clods to maxikum 5cm to 7cm and laying in layers not exceeding 0.3M depth and as per OPWD Specification and direction of the Engineer-In-Charge. |
| 3 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as per OPWD Specification and directed of the Engineer-In-charge. |
| 4 | Disposal of surplus / excavated materials by meachnical means with 5 Km lead away from the site including cost of all labour, T&P etc. completed as per OPWD Specification and directed of the Engineer-In-charge. |
| 5 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per OPWD Specification and direction of Engineer-in-Charge. |
| 6 | Providing Antitermite treatments as per ISI specification including makig hols 3'0\\" C/C both ways injecting cemical with water in properation (1:20) or any approved propertion by the Engineer-in-Charge and treatment to choukath sides and wall juction cost and conveyance of all materials, labours, R&P etc completion as per OPWD Specification and direction of Engineer-in-Charge. |
| 7 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 8 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 20 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.. But excluding cost and conveyance of HYSD bar and binding wires and labour charges for straightening, cutting, bending etc. of HYSD Bar tying the grills and placing in proper position. - Footing |
| 9 | Plinth Beam |
| 10 | Column - upto Plinth |
| 11 | Ground Floor |
| 12 | First floor |
| 13 | Second Floor |
| 14 | Linel - Ground Floor |
| 15 | First floor |
| 16 | Second Floor |
| 17 | Roof Slab - Ground Floor |
| 18 | First floor |
| 19 | Second Floor |
| 20 | Chajja & Fin - Ground Floor |
| 21 | First floor |
| 22 | Second Floor |
| 23 | Staricase - Ground Floor |
| 24 | First floor |
| 25 | Supplying cutting, bending, binding & straightening coiled or bent up HYSD Bar of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of HYSD Bar and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for HYSD Bar only) etc. complete as per OPWD specification & direction of Engineer-in-charge.. Foundation |
| 26 | Groud Floor |
| 27 | First floor |
| 28 | Second Floor |
| 29 | Fly Ash Brick masonry in C.M. (1:6) using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Foundation & Plinth |
| 30 | Ground Floor |
| 31 | First floor |
| 32 | Second Floor |
| 33 | Fly Ash Brick masonry in C.M. (1:4) using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 34 | First floor |
| 35 | 2.5cm thick grading concrete of proportion (1:2:2) over roof slab using 12mm to 6mm size cb chips of approved quality including cost, conveyance, taxes & royalty of all materials and labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.Ground floor |
| 36 | First floor |
| 37 | Providing 12 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 38 | First floor |
| 39 | Second Floor |
| 40 | Providing 16 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 41 | First floor |
| 42 | Second Floor |
| 43 | Providing 6 mm thick C.P. with C.M. (1:4) with screened and washed sharp sand for mortar and finished smooth over RCC surface in all heights including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 44 | First floor |
| 45 | Second Floor |
| 46 | Supplying, fitting, fixing of polished Vitrified floor tiles in Floor of premium grade having thickness (8mm to 10 mm) confirming to IS 15622:2006 (Group-B la) of 600mmx600mm plain (ivory) laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specicication & the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Make:Somany/ Jhonson/ Kajaria) - Ground Floor |
| 47 | First floor |
| 48 | Supplying, fitting, fixing of polished Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 15622:2006 (Group-B la) of 600mmx600mm plain (ivory) in Dados on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of tiles including cost, conveyance of all materials, cost of all labour, T&P etc. complete as OPWD specificaion per the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Make:Somany/ Jhonson/ Kajaria)Ground Floor |
| 49 | First floor |
| 50 | Providing 30cmx30cm / 40cmx40cm special plain / printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 laid on 20mm thick bed of cement mortar (1:4) and filling jointed with cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specicication & the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor |
| 51 | First floor |
| 52 | Supplying, fitting, fixing of Granite tile of size above 0.10 Sqm and upto 0.4 sqm (20mm thick) laid on 20 mm thick Cement mortar (1:4) in floors with jointed with neat cement slury mixed with pigment to match the shades of tiles including rubbing and polishing etc complete including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification and direction of the Engineer-in-charge. (Note : Sample of granite tiles shall be approved before procement and use)Ground Floor |
| 53 | First floor |
| 54 | Supplying, fitting, fixing of Granite tile of size above 0.10 Sqm and upto 0.4 sqm (10mm thick) laid on 12 mm thick Cement mortar (1:3) in Daddo with jointed with neat cement slury mixed with pigment to match the shades of tiles including rubbing and polishing etc complete including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification and direction of the Engineer-in-charge. (Note : Sample of granite tiles shall be approved before procement and use)Ground Floor |
| 55 | First floor |
| 56 | Supplying, fitting, fixing of Chequered tile laid on 20 mm thick Cement mortar (1:4) in floors with jointed with neat cement slury mixed with pigment to match the shades of tiles including rubbing and polishing etc complete including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification and direction of the Engineer-in-charge. (Note : Sample of Chequered tiles shall be approved before procement and use)Ground Floor |
| 57 | Plain cement concrete (1:2:4) nominal mix using 12cm size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete, watering, curing etc, complete to required levels laid in layers not exceeding 0-6 thick in each layer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. |
| 58 | Providing and applying two coat of Finishing inside wall surface with powder wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges including cost, conveyance, royalty, of all materials, cost of all labour, T&P etc. required for the worketc. complete in all respect as per OPWD specification & direction of Engineer-in-charge - Ground Floor |
| 59 | First floor |
| 60 | Second Floor |
| 61 | Finishing to interior wall surface with 2 (two) coats of Plastic Emulsion (P.E) Paint over a coat of primer including cost of all material of all materials and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge.- Ground Floor |
| 62 | First floor |
| 63 | Second Floor |
| 64 | Painting two (2) coats with any approvoed Synthetic Enamel paint over a coat priming to new wood or iron work including sand papering,polishing the surface smooth with cost, conveyance, taxes of all materials and labour with T&P required for the work etc.complete in all respects as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 65 | First floor |
| 66 | Second Floor |
| 67 | Finishing to exterior wall surface with 2 (two) coats of weather seal coat of approved shade and approved make to give an even shade and priming with approved new primer including cost of all material of all materials and labour with T&P etc. completeas per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 68 | First floor |
| 69 | Second Floor |
| 70 | Supplying,fitting and fixing of Stainless Steel of 304 grade in Hand Railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90 mtr. C/C and sainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification,buffing, polishing etc. with cost,conveyance,taxes of all materials,Labour,T&P etc. required for the complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 71 | First floor |
| 72 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, Steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 10mm as per approved drawing and design with cost of all labour, materials & T&P, sundries etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. |
| 73 | Providing & Fixing factory made 100% Solid WPC ( Wood Polymer Composite ) - Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process) material comprising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/cbm & an ISO 9001- 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners/ Hold Fast of required dia and length,, all as per OPWD Specification & direction the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. |
| 74 | Supplying fitting and fixing in position 32mm thick flush door with teak wood beading and 1mm thick laminatet o both side pasted with adhessive including fixing of fixtures like Godrej make Mortice lock ,handle, tower bolt,door stopper,magic eye,hinges as required including cost convency of all materials, cost of all labour,loading & unloading etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. |
| 75 | Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) (FENESTA / casement doors openable shutter - 60 series duly manufactured using UPVC reinforced profiles of 60mmx 56mm x 2.25 mm for outer frames, 102 mm x 60mmx 2.25mm for casement Door Sash Profile and 74mm x 60 mm x 2.5 mm mlullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanized upto 50 microns of minimum thickness of 2.0 mm prefabricated and welded through fusion welding the Door sash shall be fitted with 12mm thick WPC board of greenply make duly fixed with EPDM weathering seal resistance and accessories like closing looking system made of aluminum 1 No per set of sashed and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc.including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per specification and direction of Engineer-in-Charge. |
| 76 | Supply and fitting, fixing of un-plasticised Po+ly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) Three Track - Three Panel sliding window - 60 Series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5 mm for outer frames, 38mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per OPWD specification & direction of Engineer-in-charge. |
| 77 | Supply and fitting, fixing of un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) Ventilator / Top Hung - 60 Series duly manufactured using UPVC reinforced profiles of 60mmx55mmx2.5 mm for outer frames, 75mmx60mmx2.5mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per OPWD specification & direction of Engineer-in-charge. |
| 78 | Desgining, fabricating, supplying and installing in position in solid & metallic color of approved shade made out of 4mm thick aluminum composite panel material consisting of 3mm thick FR grade mineral core sandwich between 2 aluminum coil of alloy-AL3105-H16/H24 OF 0.5mm thickness making overall thickness of 4 mm. The aluminum composite panel cladding sheet shall be coil coated with Kynar 500 based PVDF/lumiflon (FEVE) based Coating (thickness 25 micron) and service coating on the reverse side shall be with PU (Thickness 5-?micron) base and coating shall be confirm to AAMA2605 standard with 10-yrs warranty done on a color coating line located in India Make:- Viva/Alucobond/alpolic as per OPWD specification & direction of Engineer-in-charge. |
| 79 | Excavation for road work in soil with hydraulic excavator of 0.9cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections and transporting to the embankment locations with all lifts & leads up to 1000m.as per approved Drawing & Technical Specifications and as per Clause - 301 of MoSRT&H Specifications for Road & Bridge works (Latest Revision). |
| 80 | E.I. Works : Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A |
| 81 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-B |
| 82 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-C |
| 83 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 84 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 85 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 86 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 87 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 88 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 89 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 90 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 91 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 92 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(Main Panel to PDB) (4X16+2X10) |
| 93 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(Main Panel to LDB) (4X10+2X6) |
| 94 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 95 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 96 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 97 | (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 98 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 99 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery greater than or equal to 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. (With fan Regulator) |
| 100 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 101 | Supplying an fixing of recess/surface mounted 2'x2' 25 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 102 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 103 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 104 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(4+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB) |
| 105 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years (CONFERENCE ROOM) |
| 106 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 107 | MCB AND RCCBSupplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 108 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 109 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 110 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 111 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 112 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 113 | EARTHINGSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 114 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel |
| 115 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. 2 runs from main LT room to electrical shaft upto 5th floor |
| 116 | Cable Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 150 sq mm |
| 117 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 118 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 119 | TERMINATION OF CABLESSupplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x150 sq mm |
| 120 | MAIN PANELS/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.60X10MM Separate Aluminium Earth bus bar should be installed.In commer-1-01 number of 250(180-200) 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaIn commer-2- 01 no of 200A 4P onload changeover switch (Make-C&S/LK(L&T)/Siemens/Schneider/ABB)Busbar-1&2 04 numbers of 500Amps COPPER busbar with busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 10 numbers of 63A 4P MCB,,10Ka ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula/L&T) Out going- 10 numbers of 32A 4P MCB,,10Ka ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula/L&T) Outgoing-02 number of 63(160-200) 4P Icu=100%Ics,10kA LSIG MCCB with TMR Release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200) |
| 121 | CABLE TRAYSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 122 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 123 | GPH works : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20mm dia C-PVC Pipes In ground floor |
| 124 | In first floor |
| 125 | 25mm dia C-PVC Pipes |
| 126 | In first floor |
| 127 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast) In Ground floor25mm dia UPVC ASTM-D Pipes |
| 128 | 32mm dia UPVC ASTM-D Pipes in first floor |
| 129 | 50mm dia UPVC ASTM-D Pipes in first floor |
| 130 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall In Ground floor |
| 131 | 250mm thick wall In First floor |
| 132 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In Ground floor |
| 133 | In First floor |
| 134 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia CP two way bib cock(CON-CHR-041KN) |
| 135 | 15 mm dia CP L.B. Bib cock(CON-CHR-107KN) |
| 136 | 15mm dia CP angle stop cock(CON-CHR-053KN) |
| 137 | 15mm dia CP flange |
| 138 | 15mm Cp extention piece |
| 139 | 25mm brass full way valve |
| 140 | 32mm brass full way valve |
| 141 | 15mm dia C.P Pillar cock(CON-CHR-021KN) |
| 142 | 125mmdia C.P.grating |
| 143 | 15mm dia CP hand shower with reebit cleaning system (ABC chrome plated-Jaquar make-HSH-CHR-85537) |
| 144 | 600mm X 125mm C.P glass shelf (ACN -CHR-1171N) |
| 145 | CP towel rail (25 mm)(ACN-CHR-1111N) |
| 146 | C.P towel ring(ACN-CHR-1121NMI) |
| 147 | CP Soap dish Holder (ACN-CHR-1131N) |
| 148 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 3.18m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.2000litre capacity water storage tanks (Ist Floor) |
| 149 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge.110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 150 | 110mm U-PVC door Tee |
| 151 | 110mm U-PVC door cross Tee |
| 152 | 110mm U-PVC plain Tee |
| 153 | 110mm U-PVC door bend |
| 154 | 110mm U-PVC plain bend |
| 155 | 110mm dia U-PVC plain shoe bend |
| 156 | 110mm dia U-PVC off set |
| 157 | 110mm dia U-PVC 'P' trap |
| 158 | 110mm dia U-PVC cowl |
| 159 | 110mm dia U-PVC clamp |
| 160 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge.250mm to 375mm thick wall |
| 161 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge..Cascade dual flushset (Hindware)No.92099 |
| 162 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge.550mmx400mm size wash hand basin with pedestall Parryware/Hind ware/Cera/Kerovit/Somany) |
| 163 | Supplying all materials, labour, T&P and fixing bowl pattern urinal of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.Half stall urinal (Jaquar)URS-WHT-13261 |
| 164 | 15mm CP spreader |
| 165 | 32mm CP doom waste |
| 166 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge.600mmx450mm size B.E mirror |
| 167 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) |
| 168 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 169 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 170 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 171 | In First floor |
| 172 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.Same as Floor tile area In 1st Floor: |
| 173 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.12mm thick CP (1:4) on bw- In gf |
| 174 | 12mm thick CP (1:4) on bw- In First floor |
| 175 | Fitting and fixing vetrified tiles Kajaria on floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, royalities and taxes etc. all complete as per direction of Engineer in charge. (Ceramic floor tiles of premium grade Somany Geostone Mist make of size 600x600mm to be pre-approved by the Engineer in charge) In Ground Floor |
| 176 | (Ceramic floor tiles of premium grade Somany Geostone Mist make of size 600x600mm to be pre-approved by the Engineer in charge) In First floor |
| 177 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles etc.complete as per direction of the Engineer in charge. (Ceramic wall tiles of premium grade Somany Daino Light(Glossy) make size 300 x 600 special plain / printed series to be pre-approved by the Engineer in charge)In ground floor (inside/outside) |
| 178 | (Ceramic wall tiles of premium grade Somany Daino Light(Glossy) make size 300 x 600 special plain / printed series to be pre-approved by the Engineer in charge)In First floor (inside/outside) |
| 179 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Casement Toilet Door 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding.The Door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant accessories like Bathroom locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges. The materials and product confirming to ASTM D 638-14, EN-477-95 and other applicable codes and standards |
| 180 | Supplying and fitting-fixing of UPVC Louvers fixed window/ventilator made of (small series)frame 47x50mm & mullion 47x68 mm both having wall thickness of 1.9± 0.2mm and single glazing bead of appropriate dimension(Area upto 0.75sqm) etc.all complete as per direction of the Engineer-in-charge. |
| 181 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 182 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 760mmx760mmx460mm |
| 183 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 910mmx910mmx910mm |
| 184 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.20m dia x 2.00m deep |
| 185 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete |
| 186 | 160mm dia u-pvc pipe alround concrete |
| 187 | Construction of 30 users RCC septic tank (I/S size-3.00mx1.20mx2.10m) Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and levelling the bed and as per direction of the Engineer in charge. |
| 188 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 189 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 190 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 191 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs up to 4.30m height |
| 192 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 193 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 194 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 195 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 196 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 197 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 198 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 199 | Sinking of 200mm x 150mm size Tube well through D.T.H or Combination drilling rigs in hard rock areas with GI/PVC casing pipesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of 200 mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/PVC casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tube well).Labour for drilling of 200 mm dia bore 00 mtr to 125 mtrs |
| 200 | 150mm dia |
| 201 | Lowering the following size G.I/ PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above.Labour for lowering of 200mm dia casing pipe in bore 00 mtr to 45 mtrs |
| 202 | Cost of 200 mm dia casing Pipe |
| 203 | Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. |
| 204 | Supplying all materials, labour, tools and plant and withdrawing casing pipes from the unsuccessful bore and depositing in the departmental store in good condition. |
| 205 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge1.00H.P single phase submersible pump set (KP4-03215 pumpset CP)Kirloskar/Crompton/CRRI make |
| 206 | DOL Control panel |
| 207 | 32mm dia steel short piece |
| 208 | Well cap |
| 209 | 50mm size CI bracket |
| 210 | 2.50 sqmm flat cable |
| 211 | Steel rope with cover |
| 212 | 20mm dia rigid UPVC pipes |
| 213 | Labour charges for lowering including transportation |
| 214 | 32mm dia HDPE pipe |
| 215 | Supplying all materials, labour, T&P and cutting metalled road for taking the GI pipe/sewer line through and making good to the damages including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 216 | Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
| 217 | Supplying all materials, labour, T & P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, earthwork in excavation in all kind of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge. |
| 218 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 219 | 10000 litre Construction of RCC UG Sump (I/s:- 2.50x 2.50x 1.65 m) Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and levelling the bed and as per direction of the Engineer in charge. |
| 220 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 221 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 222 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs up to 4.30m height |
| 223 | R.C.C beams, columns, girder and bressmer etc--In G.F |
| 224 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 225 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 226 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 227 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 228 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 229 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 230 | Supplying all materials labour T&P for Removal of sand mud & debrises by mechaanical means including cost of materials with taxes transportation all labour T&P etc all complete as per direction of E-I-C. |
| 231 | Supplying all materials, labour, T&P and providing, fitting and fixing of 5HP Three Phase Drainage Pump motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge5 H.P Open Well Pump Set (Texma Make) |
| 232 | DOL Control panel |
| 233 | 2.50 sqmm flat cable |
| 234 | Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
| 235 | Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D & pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction.40mm dia UPVC ASTM-D Pipes |
| 236 | 50mm dia UPVC ASTM-D Pipes Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail