| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating eachdeposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Dumping of stone including cost of stone ( on horizontal ) level. |
| 4 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 9 | Columns, piers, abutments, pillars, posts and struts |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Suspended floors, roofs, landings, balconies and access platform |
| 12 | Providing & fixing upto floor five level compressed stabilized earth blocks (CEB)made an appropriate mix of dry inorganic subsoil, non-expansive clay, sand, andaggregate with 5% cement as stabilizer, in mud mortar, including cost of materialscomplete. |
| 13 | Providing & fixing upto floor five level precast cement concrete solid blocks includinghoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost ofrequired centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominalsize) |
| 14 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class Kail wood |
| 15 | Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured).Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thickPre-laminated particle board with decorative lamination on both sides, Grade I,Type II, IS:12823 marked Coir Veneer Board (conforming to IS 14842) 12 mm thick |
| 16 | Providing and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall bepaid separately)First class kail wood 35 mm thick shutters |
| 17 | Providing and fixing traditionally carved wood work (Shingstak) over doors andwindows including all accessories as per the direction of the Engineer in-charge,complete with; 2nd class kail wood |
| 18 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 19 | Rough cast plaster upto 10 m height above ground level with a mixture of sandand gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over andincluding the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement |
| 20 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 21 | Providing and applying white cement based putty of average thickness 1 mm ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 22 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coatwith cement primer |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to givean even shade : Two or more coats on new work |
| 24 | Applying priming coats with primer of approved brand and manufacture havinglow VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) havingVOC content less than 50 grams/ litre |
| 25 | Cement concrete flooring 1:2:4 1 Cement :2 coarse:4 graded stone aggregate ) finished with a foating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing fo steps etc . Complete 25mm thick with 12.5 nominal size stone aggregate. |
| 26 | wooden planking, tongued and grooved in flooring, including fixing withiron screws complete |
| 27 | Marble stone flooring with 18 mm thick marble stone, as per sample of marbleapproved by Engineer-in-charge, over 20 mm (average) thick base of cementmortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry,including rubbing and polishing complete with :Makrana white second quality |
| 28 | Providing and fixing wooden moulded beading to door and window frames withiron screws, plugs and priming coat on unexposed surface etc. complete :2nd class teak wood |
| 29 | Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete :200x10 mm |
| 30 | Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete :100x10 mm |
| 31 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diaMetre bolts, nuts and wooden plugs and embedding in cement concreteblock 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 32 | Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured).Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 33 | Providing and fixing white vitreous china squatting plate urinal with integral rimlongitudinal flush pipe. |
| 34 | Providing and fixing white vitreous china wash basin including making allconnections but excluding the cost of fittings:Flat back wash basin of size 630x450mm. |
| 35 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern. |
| 36 | Providing and fixing PVC waste pipe of required dia including bends Tee door bend trap joined with addisive material ISI marked like prince, vector or equivalent brand all complete job. 90mm |
| 37 | 110 mm |
| 38 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot& cold water supply including all PP - R plain & brass threaded polypropylenerandom fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includestesting of joints complete as per direction of Engineer in Charge. (Internal workexposedon wall) PN - 16 Pipe, 25mm OD (SDR-7.4) |
| 39 | PN - 16 Pipe, 32mm OD (SDR-7.4) |
| 40 | PN-16 Pipe, 40 mm OD |
| 41 | Providing and fixing brass bib cock of approved quality :15 mm nominal borec |
| 42 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 43 | Providing and fixing C.P. brass long nose bib cock of approved quality conformingto IS standards and weighing not less than 810 gms. 15mm nominal bore. |
| 44 | providing and fixing PTMT grating of approved quality and colour .15mm |
| 45 | Providing and fixings swivelling shower ,15mm nominal bore, weighing not less than 100 grms including all necessery items all complete job. |
| 46 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end): 20mm |
| 47 | Providing and fixing ball valve (brass) of approved quality complete : High or lowpressure with plastic floats: 32mm |
| 48 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and thebase support for tank |
| 49 | Providing and fixing material for the insulation of pipe with nitrile tube, tapping with cello tape , rockwood 6 inch per side, wire mesh, polythene with cello tape aluminum sheet 26 gauge cladding with dia compldet job including carriage. 19mm thick , 50mm dia ( OD ) ( ppr 32 mm ) |
| 50 | 19mm thick , 50mm dia ( OD ) ( ppr 40 mm ) |
| 51 | Providing and fixing of material for the insulation of pipe with nitrule tube tapping with cello tape for inner woall fittings complete job including carraige 19mm thick, 50mm dia ( OD ) ( PPR 25mm) |
| 52 | Providing and fixing of material for the insulation of water storage tank of with nitrile sheet tapping with cello tape, rockwood 6 inch per side, wire mesh, polythene, aluminium sheet 26 guage cladding with dia of complete job 19mm thick, nitrule sheet. |
| 53 | Providing and fixing heat tape 33 watt on PPR pipe made of denforced or chromelox or equivalent make as approved by engineer in charge, complete job. |
| 54 | Providing and laying vitrified floor tiles in different sizes (thickness to be specifiedby the manufacturer) with water absorption less than 0.08% and conforming toIS: 15622, of approved make, in all colours and shades, laid on 20mm thickcement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @3.3 kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete. Size of Tile 600x600 mm |
| 55 | Providing and laying vitrified floor tiles in different sizes (thickness to be specifiedby the manufacturer) with water absorption less than 0.08% and conforming toIS: 15622, of approved make, in all colours and shades, laid on 20mm thickcement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @3.3 kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete. Size of Tile 600x600 mm |
| 56 | Carriage of material from source to site of work by M.T including laoding unloading and stacking complete. Cement / steel …................. 1.0 kms |
| 57 | Sand …................... 20 kms |
| 58 | Stone aggregate ….......................... 20 kms |
| 59 | Soling stone ….....................................20 kms |
| 60 | Earth ….................................... 7.0 kms |
| 61 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) includinggetting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, asdirected by Engineer-in-charge. All kinds of soil |
| 62 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surfacecomplete |
| 63 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 64 | Providing and laying 60mm thick faciory made cement in required colour and pattern over and including 50mm thick compacted bed of block making machine with strong vibratory compaction of approved size design & shape laid joints with line sand etc all complete as per the direction of Engineer-in- charge. |
| 65 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. Group A |
| 66 | Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point (without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed steel conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulatedcopper conductor single core cable etc. as required. Group A |
| 67 | Wiring of following light point with 1.5sq mm FRLS PVC insulated copper conductor cable in PVC conduit recessed including chasing of wall , filling of chasing of wall, filling of chases with cement mortar 1:3 mix and / or fixing conduit on surface of wall/ ceiling including fixing of saddles etc including modular range of plate switches, wiring ( 2x2.5+ 1x2.5 ) 1.5sq mm FRLS PVC insulated copper earth wire etc complete as required. One point conrolleed by ibe bumber 10 Amp MCB ( first point ) |
| 68 | Looping Point above |
| 69 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 70 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 71 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 72 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 73 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 25 mm |
| 74 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providng andfixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. (For light plugs tobe used in non residential buildings). |
| 75 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 76 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 77 | Supply & fixing of Universal Socket with 4.0 sq.mm PVC insulated multistranded copper conductor cable ( FRLS Type ) in surface/ recess 1.8mm thick PVC conduit including cutting the fixing of M.S Switch & outlet box, modular cover plate , earthing with 4.0sq mm PVC insulated copper conductor cable / wire ( FRLS Type ) etc complete as required & as per specifications. |
| 78 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) 8 way (4 + 24), Double door |
| 79 | Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing andcommissioning etc. as required. 63 A |
| 80 | Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. asrequired. 40 A |
| 81 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole |
| 82 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc as requuired. |
| 83 | SITE OF 8 W LED 6500 K Slim, compact, auminum die cast dege lit panel.Recess mounted round fixture with opal diffuser and separate electronic diriver . Make Havells . |
| 84 | Supply installation testing commissioning of TRIM CLOPON LED Panel Square 24 w LED 6500 K Make :- Havells Model: LHEAABP 71N1W024. |
| 85 | SITC of 20 w SFTL Light. |
| 86 | SITC OF 10 W WH LED Bulkhead Lihgt as / Specification , PDC AL Housing system watage-10w, Lumen pack-800 with eficacy 800lm /w CRI-80, IP -65 Surge protection -up 5 kv with IS 10322 ( Part 5/ sec.1 ) 2012 |
| 87 | Supply installation testing commissioning of 1200 mm fan.approved quality . |
| 88 | Supply installation testing commissioning of 1400 mm fan.approved quality |
| 89 | Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarmpanel, central processing unit with the following loopmodules and capable of supporting not less than 240 devices(including detectors) and minimum 120 detectors per loopand loop length up to 2 km, network communication card,minimum 320 character graphics/ LCD display with touchscreen or other keypad and minimum 4000 events history login the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealedmaintenance free batteries with automatic charger. Thepanel shall have facility to connect printer to printout log andfacility to have seamless integration with analog/digital voiceevacuation system (which is part of the schedule of workunder SH: PA System) and shall be complete with allaccessories . The panel shall be compatible for IBMS systemwith open protocol BACnet/ Modbus over IP complete as perspecifications. Two Loop Panel. |
| 90 | Supplying, installation, testing & commissioning ofaddressable manual call point complete as required. |
| 91 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 25 mm |
| 92 | for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 93 | Supplying, installation, testing & commissioning ofaddressable fire control module complete as required. Please Enable Macros to View BoQ information |