| 1 | Earth Work : |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, liftupto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches,plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil |
| 4 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc.complete. |
| 5 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 6 | Supplying chemical emulsion in sealed containers including delivery as specified.a)Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 7 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 8 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion): Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level: a) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size) |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-a) RCC work in suspended floors, roofs having slope upto 15° landings, balconies, shelves and chajjas.1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Centering shuttering including struttings, propping etc.and removal of form work for:-Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 15 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 17 | Suspended floors, roofs, landings, balconies and access platform with shuttering ply |
| 18 | Edges of slabs and breaks in floors and walls under 20 cm. wide |
| 19 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level. Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars |
| 20 | First class brick work in foundation and plinth including cost of all materials as required complete:-a)In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 21 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-a)In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 22 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 23 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required. |
| 24 | Providing and fixing M.S. fan clamp of type 1 or 16 mm MS bar bent to shape with holed ends in RCC slabs beams, during laying of steel excluding painting exposed portion of loop, all as per standard design complete. |
| 25 | Providing and fixing MS Grills of required pattern in frames of windows etc. with MS flats squre all complete. |
| 26 | Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade,including rubbing and polishing complete. 14 mm thick Marble stone |
| 27 | 6 mm cement plaster of mix In cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 28 | 12 mm cement plaster of mix In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 29 | 12 mm cement plaster of mix In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 30 | 15 mm cement plaster on the rough side of single or half brick wall of mix:In cement mortar 1:6 ( 1 cement :6 fine sand ). |
| 31 | Neat cement punning. |
| 32 | Distempering with 1st quality acrylic distemper ( ready mixed) havingVOC content less than 50 grams / Ltr, of approved brand manufacture and of required shade on new work ( two or more coats ), over and including water thinable priming coat to give an even shade (payment shall be made after submission of test certificate issued by manufacturer). -New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 33 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 1.67 kg/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete(payment shall be made after submission of test certificate issued by manufacturer). New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 34 | Applying priming coat:(Payment shall be made after submission of test certificate issued by the manufacturer)With ready mixed pink primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 35 | Painting with synthetic enamel paint ( two or more coats) of required colour of approved brand and manufacture on new work to give an even shade.(Payment shall be made after submission of test certificate issued by the manufacturer)-Two or more coats on new work |
| 36 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of equired grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:- Please Enable Macros to View BoQ information |